865 resultados para Validation of analytical methods


Relevância:

100.00% 100.00%

Publicador:

Resumo:

"A.E.C. Contract AT(05-1)-636."

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"Covers the period from 1842 through 1950 as represented by the Chemical abstracts and the Abstracts of the Chemical Society."

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pancuronium bromide is used with general anesthesia in surgery for muscle relaxation and as an aid to intubation. A high performance liquid chromatographic method was fully validated for the quantitative determination of pancuronium bromide in pharmaceutical injectable solutions. The analytical method was performed on an amino column (Luna 150mm4.6mm, 5m). The mobile phase was composed of acetonitrile:water containing 50mmol L-1 of 1-octane sulfonic acid sodium salt (20:80v/v) with a flow rate of 1.0mL min-1 and ultraviolet (UV) detection at 210nm. The proposed analytical method was compared with that described in the British Pharmacopoeia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Gene expression data from microarrays are being applied to predict preclinical and clinical endpoints, but the reliability of these predictions has not been established. In the MAQC-II project, 36 independent teams analyzed six microarray data sets to generate predictive models for classifying a sample with respect to one of 13 endpoints indicative of lung or liver toxicity in rodents, or of breast cancer, multiple myeloma or neuroblastoma in humans. In total, >30,000 models were built using many combinations of analytical methods. The teams generated predictive models without knowing the biological meaning of some of the endpoints and, to mimic clinical reality, tested the models on data that had not been used for training. We found that model performance depended largely on the endpoint and team proficiency and that different approaches generated models of similar performance. The conclusions and recommendations from MAQC-II should be useful for regulatory agencies, study committees and independent investigators that evaluate methods for global gene expression analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Analytical results harmonisation is investigated in this study to provide an alternative to the restrictive approach of analytical methods harmonisation which is recommended nowadays for making possible the exchange of information and then for supporting the fight against illicit drugs trafficking. Indeed, the main goal of this study is to demonstrate that a common database can be fed by a range of different analytical methods, whatever the differences in levels of analytical parameters between these latter ones. For this purpose, a methodology making possible the estimation and even the optimisation of results similarity coming from different analytical methods was then developed. In particular, the possibility to introduce chemical profiles obtained with Fast GC-FID in a GC-MS database is studied in this paper. By the use of the methodology, the similarity of results coming from different analytical methods can be objectively assessed and the utility in practice of database sharing by these methods can be evaluated, depending on profiling purposes (evidential vs. operational perspective tool). This methodology can be regarded as a relevant approach for database feeding by different analytical methods and puts in doubt the necessity to analyse all illicit drugs seizures in one single laboratory or to implement analytical methods harmonisation in each participating laboratory.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The consumer demand for natural, minimally processed, fresh like and functional food has lead to an increasing interest in emerging technologies. The aim of this PhD project was to study three innovative food processing technologies currently used in the food sector. Ultrasound-assisted freezing, vacuum impregnation and pulsed electric field have been investigated through laboratory scale systems and semi-industrial pilot plants. Furthermore, analytical and sensory techniques have been developed to evaluate the quality of food and vegetable matrix obtained by traditional and emerging processes. Ultrasound was found to be a valuable technique to improve the freezing process of potatoes, anticipating the beginning of the nucleation process, mainly when applied during the supercooling phase. A study of the effects of pulsed electric fields on phenol and enzymatic profile of melon juice has been realized and the statistical treatment of data was carried out through a response surface method. Next, flavour enrichment of apple sticks has been realized applying different techniques, as atmospheric, vacuum, ultrasound technologies and their combinations. The second section of the thesis deals with the development of analytical methods for the discrimination and quantification of phenol compounds in vegetable matrix, as chestnut bark extracts and olive mill waste water. The management of waste disposal in mill sector has been approached with the aim of reducing the amount of waste, and at the same time recovering valuable by-products, to be used in different industrial sectors. Finally, the sensory analysis of boiled potatoes has been carried out through the development of a quantitative descriptive procedure for the study of Italian and Mexican potato varieties. An update on flavour development in fresh and cooked potatoes has been realized and a sensory glossary, including general and specific definitions related to organic products, used in the European project Ecropolis, has been drafted.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

High performance liquid chromatography (HPLC) is the reference method for measuring concentrations of antimicrobials in blood. This technique requires careful sample preparation. Protocols using organic solvents and/or solid extraction phases are time consuming and entail several manipulations, which can lead to partial loss of the determined compound and increased analytical variability. Moreover, to obtain sufficient material for analysis, at least 1 ml of plasma is required. This constraint makes it difficult to determine drug levels when blood sample volumes are limited. However, drugs with low plasma-protein binding can be reliably extracted from plasma by ultra-filtration with a minimal loss due to the protein-bound fraction. This study validated a single-step ultra-filtration method for extracting fluconazole (FLC), a first-line antifungal agent with a weak plasma-protein binding, from plasma to determine its concentration by HPLC. Spiked FLC standards and unknowns were prepared in human and rat plasma. Samples (240 microl) were transferred into disposable microtube filtration units containing cellulose or polysulfone filters with a 5 kDa cut-off. After centrifugation for 60 min at 15000g, FLC concentrations were measured by direct injection of the filtrate into the HPLC. Using cellulose filters, low molecular weight proteins were eluted early in the chromatogram and well separated from FLC that eluted at 8.40 min as a sharp single peak. In contrast, with polysulfone filters several additional peaks interfering with the FLC peak were observed. Moreover, the FLC recovery using cellulose filters compared to polysulfone filters was higher and had a better reproducibility. Cellulose filters were therefore used for the subsequent validation procedure. The quantification limit was 0.195 mgl(-1). Standard curves with a quadratic regression coefficient > or = 0.9999 were obtained in the concentration range of 0.195-100 mgl(-1). The inter and intra-run accuracies and precisions over the clinically relevant concentration range, 1.875-60 mgl(-1), fell well within the +/-15% variation recommended by the current guidelines for the validation of analytical methods. Furthermore, no analytical interference was observed with commonly used antibiotics, antifungals, antivirals and immunosuppressive agents. Ultra-filtration of plasma with cellulose filters permits the extraction of FLC from small volumes (240 microl). The determination of FLC concentrations by HPLC after this single-step procedure is selective, precise and accurate.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

During recent years a consistent number of central nervous system (CNS) drugs have been approved and introduced on the market for the treatment of many psychiatric and neurological disorders, including psychosis, depression, Parkinson disease and epilepsy. Despite the great advancements obtained in the treatment of CNS diseases/disorders, partial response to therapy or treatment failure are frequent, at least in part due to poor compliance, but also genetic variability in the metabolism of psychotropic agents or polypharmacy, which may lead to sub-therapeutic or toxic plasma levels of the drugs, and finally inefficacy of the treatment or adverse/toxic effects. With the aim of improving the treatment, reducing toxic/side effects and patient hospitalisation, Therapeutic Drug Monitoring (TDM) is certainly useful, allowing for a personalisation of the therapy. Reliable analytical methods are required to determine the plasma levels of psychotropic drugs, which are often present at low concentrations (tens or hundreds of nanograms per millilitre). The present PhD Thesis has focused on the development of analytical methods for the determination of CNS drugs in biological fluids, including antidepressants (sertraline and duloxetine), antipsychotics (aripiprazole), antiepileptics (vigabatrin and topiramate) and antiparkinsons (pramipexole). Innovative methods based on liquid chromatography or capillary electrophoresis coupled to diode-array or laser-induced fluorescence detectors have been developed, together with the suitable sample pre-treatment for interference removal and fluorescent labelling in case of LIF detection. All methods have been validated according to official guidelines and applied to the analysis of real samples obtained from patients, resulting suitable for the TDM of psychotropic drugs.