992 resultados para Vacuum system


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Half of the world’s urban population will live in informal settlements or “slums” by 2030. Affordable urban sanitation presents a unique set of challenges as the lack of space and resources to construct new latrines makes the de-sludging of existing pits necessary and is something that is currently done manually with significant associated health risks. Therefore various mechanised technologies have been developed to facilitate pit emptying, with the majority using a vacuum system to remove material from the top of the pit. However, this results in the gradual accumulation of unpumpable sludge in the pit, which eventually fills the latrine and forces it to be abandoned. This study has developed a method for fluidising unpumpable pit latrine sludge, based on laboratory experiments using a harmless synthetic sludge. Such a sludge consisting of clay and compost was developed to replicate the physical characteristics of pit latrine sludges characterised in Botswana during the 1980s. Undrained shear strength and density are identified as the critical parameters in controlling pumpability and a method of sludge characterisation based on these parameters is reported. In a series of fluidisation tests using a one fifth scale pit emptying device the reduction in sludge shear strength was found to be caused by i) dilution, which increases water content, and ii) remoulding, which involves mechanical agitation to break down the structure of the material. The tests demonstrated that even the strongest of sludges could be rendered “pumpable” by sufficient dilution. Additionally, air injection alone produced a three-fold decrease in strength of consolidated samples as a result of remoulding at constant water content. The implications for sludge treatment and disposal are discussed, and the classification of sludges according to the equipment required to remove them from the latrine is proposed. Possible field tests to estimate sludge density and shear strength are suggested. The feasibility of using low cost vacuum cleaners to replace expensive vane pumps is demonstrated. This offers great potential for the development of affordable pit emptying technologies that can remove significantly stronger sludges than current devices through fluidising the wastes at the bottom of the pit before emptying

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Half of the world's urban population will live in informal settlements or ‘slums’ by 2030. Affordable urban sanitation presents a unique set of challenges as the lack of space and resources to construct new latrines makes the de-sludging of existing pits necessary and is something that is currently done manually with significant associated health risks. Various mechanised technologies have therefore been developed to facilitate pit emptying, with the majority using a vacuum system to remove material from the top of the pit. However, this results in the gradual accumulation of unpumpable sludge at the bottom of the pit, which eventually fills the latrine and forces it to be abandoned. This study has developed a method for fluidising unpumpable pit latrine sludge, based on laboratory experiments using a harmless synthetic sludge. The implications for sludge treatment and disposal are discussed, and the classification of sludges according to the equipment required to remove them from the latrine is proposed. Finally, further work is suggested, including the ongoing development of a device to physically characterise latrine sludge in-situ within the pit.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fe-N films containing the Fe16N2 phase were prepared in a high-vacuum system of ion-beam-assisted deposition (IBAD). The composition and structure of the films were analysed by Auger electron spectroscopy (AES) and X-ray diffraction (XRD), respectively. Magnetic properties of the films were measured by a vibrating sample magnetometer (VSM). The phase composition of Fe-N films depend sensitively on the N/Fe atomic arrival ratio and the deposition temperature. An Fe16N2 film was deposited successfully on a GaAs (1 0 0) substrate by IBAD at a N/Fe atomic arrival ratio of 0.12. The gram-saturation magnetic moment of the Fe16N2 film obtained is 237 emu/g at room temperature, the possible cause has been analysed and discussed. Hysteresis loops of Fe16N2 have been measured, the coercive force H-c is about 120 Oe, which is much larger than the value for Fe, this means the Fe16N2 sample exhibits a large uniaxial magnetocrystalline anisotropy. (C) 1998 Elsevier Science B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The effect of changing Be doping concentration in GaAs layer on the integrated photosensitivity for nega- tive-electron-affinity GaAs photocathodes is investigated. Two GaAs samples with the monolayer structure and the muhilayer structure are grown by molecular beam epitaxy. The former has a constant Be concentration of 1 × 10^19 cm^-3, while the latter includes four layers with Be doping concentrations of 1 × 10^19, 7 × 10^18, 4 × 10^18, and 1 × 10^18 cm^-3 from the bottom to the surface. Negative-electron-affinity GaAs photocathodes are fabricated by exciting the sample surfaces with alternating input of Cs and O in the high vacuum system. The spectral response results measured by the on-line spectral response measurement system show that the integrated photosensitivity of the photocathode with the muhilayer structure enhanced by at least 50% as compared to that of the monolayer structure. This attributes to the improvement in the crystal quality and the increase in the surface escape probability. Different stress situations are observed on GaAs samples with monolayer structure and muhilayer structure, respectively.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fe-N films containing the Fe16N2 phase were prepared in a high-vacuum system of ion-beam-assisted deposition (IBAD). The composition and structure of the films were analysed by Auger electron spectroscopy (AES) and X-ray diffraction (XRD), respectively. Magnetic properties of the films were measured by a vibrating sample magnetometer (VSM). The phase composition of Fe-N films depend sensitively on the N/Fe atomic arrival ratio and the deposition temperature. An Fe16N2 film was deposited successfully on a GaAs (1 0 0) substrate by IBAD at a N/Fe atomic arrival ratio of 0.12. The gram-saturation magnetic moment of the Fe16N2 film obtained is 237 emu/g at room temperature, the possible cause has been analysed and discussed. Hysteresis loops of Fe16N2 have been measured, the coercive force H-c is about 120 Oe, which is much larger than the value for Fe, this means the Fe16N2 sample exhibits a large uniaxial magnetocrystalline anisotropy. (C) 1998 Elsevier Science B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Argon gas with simple atomic structure and favorite arcing stability at low input power was used as the propellant. The thruster with a regeneratively cooled nozzle were tested in a vacuum system capable of keeping the chamber pressure at about 10 Pa at a propellant feeding rate of 5 slm. Arc current, arc voltage, thrust, nozzle temperature and propellant feeding rate were measured in situ simultaneously. Effects of the working parameters such as the propellant feeding rate and arc current on the thruster performances, mainly the produced thrust, specific impulse and thrust efficiency, were examined. The variation of arc volt-ampere characteristics with running time and the effect of nozzle temperature on thruster property are discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Recent vacuum system development with an XHV condition for the particle accelerators is briefly described. The progress of selecting and treatment of the materials used in XHV systems is introduced, and the choice of the main pump for an XHV system and some new pumping method are presented. Some leak detection experiences both for the superconducting and warm vacuum systems are recommended and the status of XHV measurement and the gauge calibration are introduced.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

兰州重离子加速器(HIRFL)后束运线TR2实验终端,是一个用于开展超重核研究的实验终端,实验系统工作时要求充入氦气,压强为100Pa左右,而后束运线上真空度要求为10E-6Pa,所以如何实现从实验终端充气压强为100Pa到后束运线上压强为10E-6Pa真空度的顺利过渡便成了一个重要课题。 本文从差分真空系统的原理着手,通过对差分系统材料、测量元件以及排气系统的选择,排气性能测试等,设计了TR2实验终端差分真空系统——四级差分真空系统。通过安装测试,将理论计算值与静态测试结果做了比较,引出了差分系统中充气气流效应的概念,并对该系统中充气气流效应进行定量和定性的分析,改进了差分真空系统的设计。 本文用真空系统中气体的流动与电子学电路中电子的流动相等效的思路,把四级差分真空系统等效成电子学电路,并用PSpice软件仿真计算四级差分真空系统中各级差分真空室的压力分布,并与实验结果作比较。 理论计算和静态测试结果均表明,TR2实验终端利用四级差分真空系统,可以实现从100Pa到后束运线上10E-6Pa真空度的顺利过渡

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Recent years have seen a significant growth in surface modifications in titanium implants, resulting in shorter healing times in regions with low bone density. Among the different techniques, subtraction by chemical agents to increase oxidation has been applied for surface treatment of dental implants. However, this technique is generally unable to remove undesirable oxides, formed spontaneously during machining of titanium parts, raising costs due to additional decontamination stages. In order to solve this problem, the present study used plasma as an energy source to both remove these oxides and oxidize the titanium surface. In this respect, Ti disks were treated by hollow cathode discharge, using a variable DC power supply and vacuum system. Samples were previously submitted to a cleaning process using an atmosphere of Ar, H2 and a mixture of both, for 20 and 60 min. The most efficient cleaning condition was used for oxidation in a mixture of argon (60%) and oxygen (40%) until reaching a pressure of 2.2 mbar for 60 min at 500°C. Surfaces were characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), atomic force microscopy (AFM), adhesion and cell proliferation. SEM showed less cell spreading and a larger number of projections orfilopodia in the treated samples compared to the control sample. AFM revealed surface defects in the treated samples, with varied geometry between peaks and valleys. Biological assays showed no significant difference in cell adhesion between treated surfaces and the control. With respect to cell proliferation, the treated surface exhibited improved performance when compared to the control sample. We concluded that the process was efficient in removing primary oxides as well as in oxidizing titanium surfaces

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Enterocutaneous fistulas are associated with prolonged hospital stay, high morbidity/mortality, and increase in hospital costs. This study aims to describe the use of a vacuum system and normal oral diet in dealing with this problem. Methods: Seventy-four consecutive patients with recent and defined external postoperative fistulas were analyzed. Abdominal imaging was used to exclude abscess and distal obstruction. The fistula tract was sealed with Foley catheter, connected to a negative pressure flask, changed daily for 5, 10 or 15 days, as necessary. Normal oral diet was permitted. Results: No patient died. Serum albumin and transferrin showed significantly higher levels at the end of treatment than at the beginning. The moderate and low-output fistulas had the best results (97% closed). Forty-eight (65%) fistulas closed after five days, 16(22%) after 10 days and 4(5%) after 15 days. Treatment failed in 6(8%) patients, who subsequently underwent surgery. Only one patient with low-output did not close her fistula. The cost of the treatment was US$ 41.75/day and it was considered cost effective. Conclusions: The vacuum system demonstrated good results in the treatment of fistulas. It included simplicity, low cost, short hospital stay, absence of skin breakdown, normal eating, good nutrition and activity patterns

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Colheram-se amostras de sangue do cordão umbilical (SCU) e do sangue circulante de cinco eqüinos neonatos, imediatamente após o nascimento, e o sangue da própria mãe, utilizando-se um sistema a vácuo. O material foi submetido à contagem global de hemácias e leucócitos e à determinação do volume globular e da concentração de hemoglobina; à contagem diferencial de leucócitos em esfregaços sangüíneos; e ao cálculo dos índices eritrocitométricos. Foram realizadas a dosagem de proteínas séricas totais e a eletroforese das proteínas séricas em gel de agarose. Não houve diferenças significativas entre os parâmetros do SCU e do sangue da jugular dos potros. No SCU dos potros observaram-se valores mais elevados para contagem global de hemácias (9,75x10(6)/µl), dosagem de hemoglobina (14,65g/dl) e concentração de hemoglobina corpuscular média (37,23g/dl); e valores menores para volume corpuscular médio (40,50fl), proteína total (4,37g/dl), alfa-globulinas (0,65g/dl), beta-globulinas (1,10g/dl), gama-globulinas (0g/dl) e contagens global (5,40 x 10³/µl) e diferencial de leucócitos, exceto contagem de neutrófilos bastonetes e monócitos, quando comparados com os valores obtidos no sangue de suas mães.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Research for better performance materials in biomedical applications are constants. Thus recent studies aimed at the development of new techniques for modification of surfaces. The low pressure plasma has been highlighted for its versatility and for being environmentally friendly, achieving good results in the modification of physic chemical properties of materials. However, it is requires an expensive vacuum system and cannot able to generate superficial changes in specific regions. Furthermore, it is limits their use in polymeric materials and sensitive terms due to high process temperatures. Therefore, new techniques capable of generating cold plasma at atmospheric pressure (APPJ) were created. In order to perform surface treatments on biomaterials in specific regions was built a prototype capable of generating a cold plasma jet. The prototype plasma generator consists of a high voltage source, a support arm, sample port and a nozzle through which the ionized argon. The device was formed to a dielectric tube and two electrodes. This work was varied some parameters such as position between electrodes, voltage and electrical frequency to verify the behavior of glow discharges. The disc of titanium was polished and there was a surface modification. The power consumed, length, intensity and surface modifications of titanium were analyzed. The energy consumed during the discharges was observed by the Lissajous figure method. To check the length of the jets was realized with Image Pro Plus software. The modifications of the titanium surfaces were observed by optical microscopy (OM ) and atomic force microscopy (AFM ). The study showed that variations of the parameters such as voltage, frequency and geometric position between the electrodes influence the formation of the plasma jet. It was concluded that the plasma jet near room temperature and atmospheric pressure was able to cause modifications in titanium surface

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this study is to describe the implementation of the Low Energy Electron Diffaction (LEED) technique in the Laboratory of Magnetic Nanostructures and Semiconductors of the Department of Theoretical and Experimental Physics of the Universidade Federal do Rio Grande do Norte (UFRN), Natal, Brazil. During this work experimental apparatus were implemented for a complete LEED set-up. A new vacuum system was also set up. This was composed of a mechanical pump, turbomolecular pump and ionic pump for ultra-high vacuum and their respective pressure measurement sensors (Pirani gauge for low vacuum measures and the wide range gauge -WRG); ion cannon maintenance, which is basically mini-sputtering, whose function is sample cleaning; and set-up, maintenance and handling of the quadrupole mass spectrometer, whose main purpose is to investigate gas contamination inside the ultra-high vacuum chamber. It should be pointed out that the main contribution of this Master's thesis was the set-up of the sample heating system; that is, a new sample holder. In addition to the function of sample holder and heater, it was necessary to implement the function of sustaining the ultra-high vacuum environment. This set of actions is essential for the complete functioning of the LEED technique

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A microactuator made from poly(vinylidene fluoride) (PVDF), a piezoelectric polymer, was fabricated to control the gas flow rate through a glass micronozzle. The actuator was formed by gluing together two PVDF sheets with opposite polarization directions. The sheets were covered with thin conducting films on one side, that were then used as electrodes to apply an electric field to move the valve. The actuator has a rectangular shape, 3 mm x 6 mm. The device was incorporated with a micronozzle fabricated by a powder blasting technique. Upon applying a DC voltage across the actuator electrodes, one sheet expands while the other contracts, generating an opening motion. A voltage of +300 V DC was used to open the device by moving the actuator 30 mu m, and a voltage of -200 V DC was used to close the device by moving the actuator 20 mu m lower than the relaxed position. Flow measurements were performed in a low-pressure vacuum system, maintaining the microvalve inlet pressure constant at 266 Pa. Tests carried out with the actuator in the open position and with a pressure ratio (inlet pressure divided by outlet pressure) of 0.5, indicated a flow rate of 0.36 sccm. In the closed position, and with a pressure ratio of 0.2, a flow rate of 0.32 sccm was measured.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Rare earth (RE) ions have spectroscopic characteristics to emit light in narrow lines, which makes RE complexes with organic ligands candidates for full color OLED (Organic Light Emitting Diode) applications. In particular, beta-diketone rare earth (RE(3+)) complexes show high fluorescence emission efficiency due to the high absorption coefficient of the beta-diketone and energy transfer to the central ion. In this work, the fabrication and the electroluminescent properties of devices containing a double and triple-layer OLED using a new beta-diketone complex, [Eu(bmdm)(3)(tppo)(2)], as transporting and emitting layers are compared and discussed. The double and triple-layer devices based on this complex present the following configurations respectively: device 1: ITO/TPD (40 nm)/[Eu(bmdm)(3)(tppo)(2)] (40 nm)/Al (150 nm); device 2: ITO/TPD (40 nm)/[Eu(bmdm)(3) (tppo)(2)] (40 nm)/Alq(3) (20 nm)/Al (150 nm) and device 3: ITO/TPD (40 nm)/bmdm-ligand (40 nm)/Al (150 nm), were TPD is (N,N'-diphenyl-N,N'-bis(3-methylphenyl)-1,1-biphenil-4,4-diamine) and bmdm is butyl methoxy-dibenzoyl-methane. All the films were deposited by thermal evaporation carried out in a high vacuum system. These devices exhibit high intensity photo- (PL) and electro-luminescent (EL) emission. Electroluminescence spectra show emission from Eu(3+) ions attributed to the (5)D(0) to (7)F(J) (J = 0, 1, 2, 3 and 4) transitions with the hypersensitive (5)D(o) -> (7)F(2) transition (around 612 nm) as the most prominent one. Moreover, a transition from (5)D(1) to (7)F(1) is also observed around 538 nm. The OLED light emission was almost linear with the current density. The EL CIE chromaticity coordinates (X = 0.66 and Y = 0.33) show the dominant wavelength, lambda(d) = 609 nm, and the color gamut achieved by this device is 0.99 in the CIE color space. (c) 2006 Elsevier B.V. All rights reserved.