31 resultados para VCA
Resumo:
Relatório do Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia de Electrónica e Telecomunicações
Resumo:
This paper proposes an FPGA-based architecture for onboard hyperspectral unmixing. This method based on the Vertex Component Analysis (VCA) has several advantages, namely it is unsupervised, fully automatic, and it works without dimensionality reduction (DR) pre-processing step. The architecture has been designed for a low cost Xilinx Zynq board with a Zynq-7020 SoC FPGA based on the Artix-7 FPGA programmable logic and tested using real hyperspectral datasets. Experimental results indicate that the proposed implementation can achieve real-time processing, while maintaining the methods accuracy, which indicate the potential of the proposed platform to implement high-performance, low cost embedded systems.
Resumo:
Hyperspectral instruments have been incorporated in satellite missions, providing large amounts of data of high spectral resolution of the Earth surface. This data can be used in remote sensing applications that often require a real-time or near-real-time response. To avoid delays between hyperspectral image acquisition and its interpretation, the last usually done on a ground station, onboard systems have emerged to process data, reducing the volume of information to transfer from the satellite to the ground station. For this purpose, compact reconfigurable hardware modules, such as field-programmable gate arrays (FPGAs), are widely used. This paper proposes an FPGA-based architecture for hyperspectral unmixing. This method based on the vertex component analysis (VCA) and it works without a dimensionality reduction preprocessing step. The architecture has been designed for a low-cost Xilinx Zynq board with a Zynq-7020 system-on-chip FPGA-based on the Artix-7 FPGA programmable logic and tested using real hyperspectral data. Experimental results indicate that the proposed implementation can achieve real-time processing, while maintaining the methods accuracy, which indicate the potential of the proposed platform to implement high-performance, low-cost embedded systems, opening perspectives for onboard hyperspectral image processing.
Resumo:
Introduction. In utero, l’infection des membranes maternelles et fœtales, la chorioamniotite, passe souvent inaperçue et, en particulier lorsque associée à une acidémie, due à l’occlusion du cordon ombilical (OCO), comme il se produirait au cours du travail, peut entrainer des lésions cérébrales et avoir des répercussions neurologiques péri - et postnatales à long terme chez le fœtus. Il n'existe actuellement aucun moyen de détecter précocement ces conditions pathologiques in utéro afin de prévenir ou de limiter ces atteintes. Hypothèses. 1)l’électroencéphalogramme (EEG) fœtal obtenu du scalp fœtal pourrait servir d’outil auxiliaire à la surveillance électronique fœtale du rythme cardiaque fœtal (RCF) pour la détection précoce d'acidémie fœtale et d'agression neurologique; 2) la fréquence d’échantillonnage de l’ECG fœtal (ECGf) a un impact important sur le monitoring continu de la Variabilité du Rythme Cardiaque (VRCf) dans la prédiction de l’acidémie fœtale ; 3) les patrons de la corrélation de la VRCf aux cytokines pro-inflammatoires refléteront les états de réponses spontanées versus inflammatoires de la Voie Cholinergique Anti-inflammatoire (VCA); 4) grâce au développement d’un modèle de prédictions mathématiques, la prédiction du pH et de l’excès de base (EB) à la naissance sera possible avec seulement une heure de monitoring d’ECGf. Méthodes. Dans une série d’études fondamentales et cliniques, en utilisant respectivement le mouton et une cohorte de femmes en travail comme modèle expérimental et clinique , nous avons modélisé 1) une situation d’hypoxie cérébrale résultant de séquences d’occlusion du cordon ombilical de sévérité croissante jusqu’à atteindre un pH critique limite de 7.00 comme méthode expérimentale analogue au travail humain pour tester les première et deuxième hypothèses 2) un inflammation fœtale modérée en administrant le LPS à une autre cohorte animale pour vérifier la troisième hypothèse et 3) un modèle mathématique de prédictions à partir de paramètres et mesures validés cliniquement qui permettraient de déterminer les facteurs de prédiction d’une détresse fœtale pour tester la dernière hypothèse. Résultats. Les séries d’OCO répétitives se sont soldés par une acidose marquée (pH artériel 7.35±0.01 à 7.00±0.01), une diminution des amplitudes à l'électroencéphalogramme( EEG) synchronisé avec les décélérations du RCF induites par les OCO accompagnées d'une baisse pathologique de la pression artérielle (PA) et une augmentation marquée de VRCf avec hypoxie-acidémie aggravante à 1000 Hz, mais pas à 4 Hz, fréquence d’échantillonnage utilisée en clinique. L’administration du LPS entraîne une inflammation systémique chez le fœtus avec les IL-6 atteignant un pic 3 h après et des modifications de la VRCf retraçant précisément ce profil temporel des cytokines. En clinique, avec nos cohortes originale et de validation, un modèle statistique basée sur une matrice de 103 mesures de VRCf (R2 = 0,90, P < 0,001) permettent de prédire le pH mais pas l’EB, avec une heure d’enregistrement du RCF avant la poussée. Conclusions. La diminution de l'amplitude à l'EEG suggère un mécanisme d'arrêt adaptatif neuroprotecteur du cerveau et suggère que l'EEG fœtal puisse être un complément utile à la surveillance du RCF pendant le travail à haut risque chez la femme. La VRCf étant capable de détecter une hypoxie-acidémie aggravante tôt chez le fœtus à 1000Hz vs 4 Hz évoque qu’un mode d'acquisition d’ECG fœtal plus sensible pourrait constituer une solution. Des profils distinctifs de mesures de la VRCf, identifiés en corrélation avec les niveaux de l'inflammation, ouvre une nouvelle voie pour caractériser le profil inflammatoire de la réponse fœtale à l’infection. En clinique, un monitoring de chevet de prédiction du pH et EB à la naissance, à partir de mesures de VRCf permettrait des interprétations visuelles plus explicites pour des prises de décision plus exactes en obstétrique au cours du travail.
Resumo:
Estudio exploratorio en el campo de la eficacia, basado en la teoría sistémica de calidad de Arturo de la Orden, para determinar las variables más adecuadas que pudieran ser incluidas en algún modelo de futuras investigaciones. Se trata de la detección de indicadores predictores en función de la alta correlación entre productos y ciertos elementos influyentes, que representan a las entradas procesos y contexto del sistema. Los predictores fueron seleccionados entre aquellas variables identificadas en investigaciones anteriores, como condicionantes del tipo de producto logrado. Se utilizó un sistema de indicadores especialmente generado para ello. Los procedimientos evaluativos para activar los indicadores se concretaron en seis instrumentos para: alumnos, profesores, directivos, egresados, empleadores y padres de familia. Se analiza la incidencia tanto global como individual de los predictores en la obtención del producto educativo, para conocer la proporción de varianza en el producto explicada por dichos elementos. En el sistema desarrollado se parte de cuatro Dimensiones: Satisfacción, Rendimiento Académico, Prestigio Institucional y Desempeño Laboral. Las dos primeras se tomaron como variables dependientes (criterio): nivel general de satisfacción (NGS) y nivel general de rendimiento académico (NGR). Las otras dos dimensiones se incluyeron en el conjunto de variables independientes que son: valoración de la acción docente (VAD), del liderazgo académico (VLA), de recursos materiales (VRM), de la organización académica (VOA), de condiciones académicas previas de alumnos (VCA), de condiciones socioeconómicas de alumnos (VCS), del prestigio institucional (VPI) y del rendimiento laboral de egresados (VDL). Los resultados confirman que las variables que condicionan y predicen la eficacia y por tanto permiten valorar la calidad educativa en dicha perspectiva fueron: VRM, VLA, VAD, VOA y VPI, mientras que VDL requiere modificaciones y VCS y VCA parecen no predecir el producto de la forma aquí planteadas.
Resumo:
Dissertação apresentada ao Programa de Mestrado em Comunicação da Universidade Municipal de São Caetano do Sul - USCS
Resumo:
The present article describes the preparation and characterization A anionic Collagen gels obtained from porcine intestinal submucosa after 72 h of alkaline treatment and in the form of rhamsan composites to develop injectable biomaterials for plastic for construction. All materials were characterized by SDS/polyacrylamide gel electrophoresis, infrared spectroscopy, thermal stability, potentiometric titration, rheological properties, and fluidity tests. Biocompatibility was appraised after the injection of anionic collagen:rhamsan composites at 2.5% in 60 North Folk rabbits. Independently of processing, the Collagen's secondary structure was preserved in all cases, and after 72 h of hydrolysis the Collagen was characterized by a carboxyl group content of 346 :L 9, which, at physiological pH, corresponds to an increase of 106 17 negative charges, in comparison to native Collagen, due to the selective hydrolysis of asparagine and glutamine carboxyamide side chain. Rheological studies of composites at pH 7.4 in concentrations of 2, 4, and 6% (in proportions of 75:1 and 50:1) showed a viscoelastic behavior dependent on the frequency, which is independent of concentration and proportion. In both, the concentration of the storage modulus always predominated over the loss modulus (G' > G and delta < 45 degrees). The results from creep experiments confirmed this behavior and showed that anionic collagen:rhamsan composites at pH 7.4 in the proportion of 50:1 are less elastic and more susceptible to deformation in comparison to gels in the proportion of 75:1, independent of concentration. This was further confirmed by flow experiments, indicating that the necessary force for the extrusion of anionic collagen:rhamsan composites, in comparison to anionic Collagen, was significantly smaller and with a smooth flow. Biocompatibility studies showed that the tissue reaction of anionic collagen:rhamsan composites at 2.5% in the proportion of 75:1 was compatible with the application of these gels in plastic reconstruction. These results suggest that the association of Collagen with rhamsan may be a good alternative in the replacement of glutaraidehyde to stabilize the microfibril assembly of commercial Collagen gel preparations. (c) 2005 Wiley Periodicals, Inc.
Resumo:
Major problems with the treatment of osteomyelitis are associated with poor antibiotic distribution at the site of infection due to limited blood circulation to the skeletal tissue. Improved treatment procedures have been used in drug delivery systems that include bioceramics and natural and synthetic polymers. This work reports the development of anionic collagen:hydroxyapatite composite paste for sustained antibiotic release. Antibiotic release by the composite was characterized by two steps. In the first, 15.0 +/- 4.9% was released in the first 5 h (n = 53) by a normal Fick diffusion mechanism. In the second step, only 16.8 +/- 2.2% was released after 7 days. In conclusion, hydroxyapatite:anionic collagen composite can be an efficient support for sustained antibiotic release in the treatment of osteomyelitis because most of the antibiotic release may be associated with composite bioresorption, thus permitting antibiotic release throughout the healing process. Hydroxyapatite:anionic collagen paste showed good biocompatibility associated with bone tissue growth with material still being observed after 60 days from the time of implants.
Resumo:
A principal aplicação dos métodos eletromagnéticos é a prospecção de sulfetos maciços que pela própria natureza geológica são corpos longos e delgados, encrustados em rocha encaixante resistiva, permitindo a interpretação através de curvas de modelos reduzidos usando semi-planos em meio resistivo (ar-livre). No entanto, com a extensão do uso dos métodos eletromagnéticos em regiões que tem um manto de intemperismo de parcialmente condutivo a condutivo, como na região Amazônica e nas regiões semi-áridas ou de climas tropicais , esta técnica de interpretação tem levado a resultados bem diferentes da situação real. O objetivo deste trabalho é estudar a influência do manto de intemperismo em contato ôhmico com o corpo-alvo, utilizando os arranjos de bobinas horizontal coplanar (HCP), vertical coplanar (VCP), vertical coaxial (VCA) e mínimo (PERP), através do modelagem analógico. Para simular o corpo foram utilizadas placas de grafite, cujas dimensões satisfazem a condição de semi-plano. Para simular o manto foi usada uma solução de cloreto de amônia. De forma geral, os resultados obtidos com os diversos arranjos apresentaram as mesmas características, ressalvada as diferenças peculiares de cada arranjo. De forma resumida tem-se as seguintes alterações na anomalia atribuídas à um manto condutivo em contato ôhmico com o corpo-alvo: i) Há rotação de fase, que inicialmente é em sentido anti-horário, mas mais adiante, com o aumento do número de indução do manto , torna-se horária; ii) Alteração na forma padrão do perfil de quadratura devido ao surgimento do pico extra no lado a favor do mergulho; iii) Só há uniformidade de comportamento para o pico-a-pico contra da quadratura, que cresce com o aumento número de indução do manto. Maiores anomalias são obtidas com o sistema horizontal coplanar e as menores com o vertical coplanar. Neste estudo não foi observado formação de pico extra nas anomalias do arranjo vertical coplanar. Ainda, os efeitos de cobertura são mais acentuados no sistema horizontal coplanar comparados aos sistemas de bobina vertical e em anomalias de semi-planos menos inclinados e em menor profundidade.
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Currently, systemic immunosuppression is used in vascularized composite allotransplantation (VCA). This treatment has considerable side effects and reduces the quality of life of VCA recipients. We loaded the immunosuppressive drug tacrolimus into a self-assembled hydrogel, which releases the drug in response to proteolytic enzymes that are overexpressed during inflammation. A one-time local injection of the tacrolimus-laden hydrogel significantly prolonged graft survival in a Brown Norway-to-Lewis rat hindlimb transplantation model, leading to a median graft survival of >100 days compared to 33.5 days in tacrolimus only-treated recipients. Control groups with no treatment or hydrogel only showed a graft survival of 11 days. Histopathological evaluation, including anti-graft antibodies and complement C3, revealed significantly reduced immune responses in the tacrolimus-hydrogel group compared with tacrolimus only. In conclusion, a single-dose local injection of an enzyme-responsive tacrolimus-hydrogel is capable of preventing VCA rejection for >100 days in a rat model and may offer a new approach for immunosuppression in VCA.
Resumo:
The aim of the research is to develop an e-business selection framework for small and medium enterprises (SMEs) by integrating established techniques in planning. The research is case based, comprising four case studies carried out in the printing industry for the purpose of evaluating the framework. Two of the companies are from Singapore, while the other two are from Guangzhou, China and Jinan, China respectively. To determine the need of an e-business selection framework for SMEs, extensive literature reviews were carried out in the area of e-business, business planning frameworks, SMEs and the printing industry. An e-business selection framework is then proposed by integrating the three established techniques of the Balanced Scorecard (BSC), Value Chain Analysis (VCA) and Quality Function Deployment (QFD). The newly developed selection framework is pilot tested using a published case study before actual evaluation is carried out in four case study companies. The case study methodology was chosen because of its ability to integrate diverse data collection techniques required to generate the BSC, VCA and QFD for the selection framework. The findings of the case studies revealed that the three techniques of BSC, VCA and QFD can be integrated seamlessly to complement on each other’s strengths in e-business planning. The eight-step methodology of the selection framework can provide SMEs with a step-by-step approach to e-business through structured planning. Also, the project has also provided better understanding and deeper insights into SMEs in the printing industry.
Resumo:
This chapter reports on a framework that has been successfully used to analyze the e-business capabilities of an organization with a view to developing their e-capability maturity levels. This should be the first stage of any systems development project. The framework has been used widely within start-up companies and well-established companies both large and small; it has been deployed in the service and manufacturing sectors. It has been applied by practitioners and consultants to help improve e-business capability levels, and by academics for teaching and research purposes at graduate and undergraduate levels. This chapter will provide an account of the unique e-business planning and analysis framework (E-PAF) and demonstrate how it works via an abridged version of a case study (selected from hundreds that have been produced). This will include a brief account of the three techniques that are integrated to form the analysis framework: quality function deployment (QFD) (Akao, 1972), the balanced scorecard (BSC) (Kaplan & Norton, 1992), and value chain analysis (VCA) (Porter, 1985). The case study extract is based on an online community and dating agency service identified as VirtualCom which has been produced through a consulting assignment with the founding directors of that company and has not been published previously. It has been chosen because it gives a concise, comprehensive example from an industry that is relatively easy to relate to.