942 resultados para Under-the-curve
Resumo:
The present study was made to check if the Trad-MCN bioassay, developed with inflorescences of Tradescantia pallida cv. Purpurea, might discriminate genotoxic risks in areas of the city of Santo Andre (SE Brazil) contaminated by different air pollutants, and periods of the year when risks are higher, and to determine if the variations in the frequency of micronuclei (MCN) can be explained by environmental factors that characterize the stressful situation in each site. Potted plants were exposed in sites highly contaminated by ozone (Capuava and School) and in sites reached by high vehicular emissions (downtown and Celso Daniel Park). Pedroso Park, far from the polluted areas, was taken as reference. From September 2003 to September 2004, 20 young inflorescences were collected twice a week from each place and the frequencies of MCN were estimated. The environmental conditions observed in the polluted sites were stressful enough to promote an increase of MCN, mainly in sites reached by high vehicular emissions. But MCN rates in Capuava and at Celso Daniel Park could not be predicted only by pollutants which characterized the air contamination in these sites. More severe weather conditions, mainly low temperature, relative humidity and rainfall, caused an increase of MCN. Improvement of the biomonitoring system is recommended to minimize this negative influence of weather factors. (C) 2008 Elsevier Inc. All rights reserved.
Resumo:
Diagnosis of autoimmune hepatitis (AIH) may be challenging. However, early diagnosis is important because immunosuppression is life-saving. Diagnostic criteria of the International Autoimmune Hepatitis Group (IAIHG) were complex and purely meant for scientific purposes. This study of the IAIHG aims to define simplified diagnostic criteria for routine clinical practice. Candidate criteria included sex, age, autoantibodies, immunoglobutins, absence of viral hepatitis, and histology. The training set included 250 AIH patients and 193 controls from 11 centers worldwide. Scores were built from variables showing predictive ability in univariate analysis. Diagnostic value of each score was assessed by the area under the receiver operating characteristic (ROC) curve. The best score was validated using data of an additional 109 AIH patients and 284 controls. This score included autoantibodies, immunoglobulin G, histology, and exclusion of viral hepatitis. The area under the curve for prediction of AIH was 0.946 in the training set and 0.91 in the validation set. Based on the ROC curves, two cutoff points were chosen. The score was found to have 88% sensitivity and 97% specificity (cutoff >= 6) and 81% sensitivity and 99% specificity (cutoff 2:7) in the validation set. Conclusion: A reliable diagnosis of AIH can be made using a very simple diagnostic score. We propose the diagnosis of probable AIH at a cutoff point greater than 6 points and definite AIH 7 points or higher.
Resumo:
The paraventricular nucleus of the hypothalamus (PVN) has been implicated in several aspects of cardiovascular control. Stimulation of the PVN evokes changes in blood pressure and heart rate. Additionally, this brain area is connected to several limbic structures implicated in behavioral control, as well as to forebrain and brainstem structures involved in cardiovascular control. This evidence indicates that the PVN may modulate cardiovascular correlates of behavioral responses to stressful stimuli. Acute restraint is an unavoidable stressor that evokes marked and sustained cardiovascular changes, which are characterized by elevated mean arterial pressure (MAP) and an intense heart rate (HR) increase. We report on the effect of inhibition of PVN synapses on MAP and HR responses evoked by acute restraint in rats. Bilateral microinjection of the nonspecific synaptic blocker cobalt (CoCl2, 1mM/100nl) into the PVN did not change the HR response or the initial peak of the MAP response to restraint stress, but reduced the area under the curve of the MAP response. Moreover, bilateral microinjection of cobalt in areas surrounding the PVN did not change the cardiovascular response to restraint. These results indicate that synapses in the PVN are involved in the neural pathway that controls blood pressure changes evoked by restraint.
Resumo:
Purpose: To correlate ovarian reserve (OR) markers with response in assisted reproduction techniques (ART) and determine their ability to predict poor response among patients with endometriosis (EDT). Methods: We evaluated ART cycles of 27 women with EDT and 50 with exclusive male factor. Basal follicle stimulating hormone (FSH) and anti-mullerian hormone (AMH) levels were determined. Ovarian response to gonadotropin stimulation was assessed and correlation coefficients calculated between the variables and reserve markers. Areas under the curve (AUC) determined ability of tests to predict poor response. Results: AMH was significantly correlated with response in both groups and it was the only marker with significant discriminative capacity to predict poor response among EDT (AUC = 0.842; 95% CI: 0.651-0.952) and control group (AUC = 0.869; 95% CI: 0.743-0.947). Conclusion: Infertile patients with endometriosis can benefit from the pre-therapeutic assessment of OR markers. However, regardless of disease presence, only AMH predicts poor response to stimulus.
Resumo:
Depressed patients have reduced glucocorticoid receptor (GR) function, as demonstrated by resistance to the suppressive effects of the synthetic glucocorticoid hormone, and GR agonist, dexamethasone. We have developed a suppressive test with prednisolone, a synthetic glucocorticoid that is similar to cortisol in its pharmacodynamics and pharmacokinetics, and binds to both the GR and the mineralocorticoid receptor (MR). We have found that depressed patients suppress normally to prednisolone, unless they are particularly non-responsive to treatment. In the present study, we evaluated 28 inpatients with treatment-resistant depression (TRD), and compared salivary cortisol secretion (at 0900 h, 1200 h and 1700 h) after placebo or after prednisolone (5 mg), before and after an inpatient treatment admission. Half of the patients (n = 14) reached treatment response. When comparing the assessment between admission and discharge, cortisol output after placebo fell (-26% of area under the curve; p = 0.024) while the output after prednisolone did not change. Moreover, there was no change in the response to prednisolone (percentage suppression) between admission at discharge, and this was not influenced by treatment response. Finally, we could confirm and extend our previously published data with prednisolone (5 mg), showing that depressed patients (n = 12) and controls (n = 12) suppressed equally to both 5 and 10 mg doses of prednisolone. This study suggests that the response to prednisolone is similar in depressed patients and controls at different doses of prednisolone, and does not change with symptomatic improvement. This is in contrast with findings, from us and others, using other measures of hypothalamic-pituitary-adrenal axis function, such as basal cortisol levels or the response to dexamethasone. Thus, we propose that the prednisolone suppression test may offer specific biological and clinical information, related to its action at both the GR and the MR. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
Background: This study was aimed at assessing the psychometric qualities of the abbreviated versions of the Alcohol Use Disorders Identification Test (AUDIT-3, AUDIT-4, AUDIT-C, AUDIT-PC, AUDIT-QF, FAST, and Five-Shot) and at comparing them to the 10-item AUDIT and the CAGE in 2 samples of Brazilian adults. Methods: The validity and internal consistency of the scales were assessed in a sample of 530 subjects attended at an emergency department and at a Psychosocial Care Center for Alcohol and Drugs. The Structured Clinical Interview for DSM-IV was used as the diagnostic comparative measure for the predictive validity assessment. The concurrent validity between the scales was analyzed by means of Pearson`s correlation coefficient. Results: The assessment of the predictive validity of the abbreviated versions showed high sensitivity (of 0.78 to 0.96) and specificity (of 0.74 to 0.94) indices, with areas under the curve as elevated as those of the AUDIT (0.89 and 0.92 to screen for abuse and 0.93 and 0.95 in the screening of dependence). The CAGE presented lower indices: 0.81 for abuse and 0.87 for dependence. The analysis of the internal consistency of the AUDIT and its versions exhibited Cronbach`s alpha coefficients between 0.83 and 0.94, while the coefficient for the CAGE was 0.78. Significant correlations were found between the 10-item AUDIT and its versions, ranging from 0.91 to 0.99. Again, the results for the CAGE were satisfactory (0.77), although inferior to the other instruments. Conclusions: The results obtained in this study confirm the validity of the abbreviated versions of the AUDIT for the screening of alcohol use disorders and show that their psychometric properties are as satisfactory as those of the 10-item AUDIT and the CAGE.
Resumo:
Objective: To investigate the accuracy of the Brazilian version of the Addenbrooke Cognitive Examination-revised (ACE-R) in the diagnosis of mild Alzheimer disease (AD). Background: The ACE-R is an accurate and brief cognitive battery for the detection of mild dementia, especially for the discrimination between AD and frontotemporal dementia. Methods: The battery was administered to 31 patients with mild AD and 62 age-matched and education-matched cognitively healthy controls. Both groups were selected using the Dementia Rating Scale and were submitted to the ACE-R. Depression was ruled out in both groups by the Cornell Scale for Depression in Dementia. The performance of patients and controls in the ACE-R was compared and receiver operator characteristic curve analysis was undertaken to ascertain the accuracy of the instrument for the diagnosis of mild AD. Results: The mean scores at the ACE-R were 63.10 +/- 10.22 points for patients with AD and 83.63 +/- 7.90 points for controls. The cut-off score < 78 yielded high diagnostic accuracy (receiver operator characteristic area under the curve = 0.947), with 100% sensitivity, 82.26% specificity, 73.8% positive predictive value, and 100% negative predictive value. Conclusions: The Brazilian version of the ACE-R displayed high diagnostic accuracy for the identification of mild AD in the studied sample.
Resumo:
The K5 Plan for the defence of the Cambodian-Thai border was the response of the People's Republic of Kampuchea and its Vietnamese mentors to the threat posed by the resistance forces, particularly the Khmer Rouge, to its efforts to rebuild the nation and consolidate its administration. The very real defence gains, however, were made at the cost of bitter popular resentment over the way those gains were made.
Resumo:
In a prospective study 105 patients with symptoms of stress incontinence underwent video-urodynamic testing, including resting urethral pressure profilometry and translabial ultrasound. The urethral pressure profile (UPP) included maximum urethral closure pressure (MUCP), functional length (FL) and area under the curve (AUC). Ultrasound parameters included urethral thickness, urethral rotation and bladder neck descent, as well as funneling/opening of the internal urethral meatus on Valsalva maneuver. Levator contraction strength was assessed measuring the cranioventral displacement of the internal meatus. Negative correlations between UPP data and age, parity and previous surgery were observed which were consistent with literature data. There was a positive correlation :between the urethral AP diameter on ultrasound and the MUCP, which agrees with reports showing reduced sphincter thickness or volume in stress-incontinent women. Hypermobility on ultrasound did not correlate with UPP data. However, a lower MUCP correlated with extensive opening of the bladder neck. Finally, there was a trend towards poorer pelvic floor function with lower MUCP measurements.
Resumo:
A data warehouse is a data repository which collects and maintains a large amount of data from multiple distributed, autonomous and possibly heterogeneous data sources. Often the data is stored in the form of materialized views in order to provide fast access to the integrated data. One of the most important decisions in designing a data warehouse is the selection of views for materialization. The objective is to select an appropriate set of views that minimizes the total query response time with the constraint that the total maintenance time for these materialized views is within a given bound. This view selection problem is totally different from the view selection problem under the disk space constraint. In this paper the view selection problem under the maintenance time constraint is investigated. Two efficient, heuristic algorithms for the problem are proposed. The key to devising the proposed algorithms is to define good heuristic functions and to reduce the problem to some well-solved optimization problems. As a result, an approximate solution of the known optimization problem will give a feasible solution of the original problem. (C) 2001 Elsevier Science B.V. All rights reserved.