902 resultados para Ultimate Load


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Recent reports have indicated that 23.5% of the nation's highway bridges are structurally deficient and 17.7% are functionally obsolete. A significant number of these bridges are on the Iowa secondary road system where over 86% of the rural bridge management responsibilities are assigned to the counties. Some of the bridges can be strengthened or otherwise rehabilitated, but many more are in need of immediate replacement. In a recent investigation (HR-365 "Evaluation of Bridge Replacement Alternatives for the County Bridge System") several types of replacement bridges that are currently being used on low volume roads were identified. It was also determined that a large number of counties (69%) have the ability and are interested in utilizing their own forces to design and construct short span bridges. After reviewing the results from HR-365, the research team developed one "new" bridge replacement concept and a modification of a replacement system currently being used. Both of these bridge replacement alternatives were investigated in this study, the results of which are presented in two volumes. This volume (Volume 2) presents the results of Concept 2 - Modification of the Beam-in-Slab Bridge. Concept 1 - Steel Beam Precast Units is presented in Volume 1. Concept 2 involves various laboratory tests of the Beam-in-Slab bridge (BISB) currently being used by Benton County and several other Iowa counties. In this investigation, the behavior and strength of the BISB were determined; a new method of obtaining composite action between the steel beams and concrete was also tested. Since the Concept 2 bridge is primarily intended for use on low-volume roads, the system can be constructed with new or used beams. In the experimental part of the investigation, there were three types of laboratory tests: push-out tests, service and ultimate load tests of models of the BISB, and composite beam tests utilizing the newly developed shear connection. In addition to the laboratory tests, there was a field test in which an existing BISB was service load tested. An equation was developed for predicting the strength of the shear connection investigated; in addition, a finite element model for analyzing the BISB was also developed. Push-out tests were completed to determine the strength of the recently developed shear connector. A total of 36 specimens were tested, with variables such as hole diameter, hole spacing, presence of reinforcement, etc. being investigated. In the model tests of the BISB, two and four beam specimens [L=9,140 mm (30 ft)] were service load tested for behavior and load distribution data. Upon completion of these tests, both specimens were loaded to failure. In the composite beam tests, four beams, one with standard shear studs and three using the shear connection developed, were tested. Upon completion of the service load tests, all four beams were loaded to failure. The strength and behavior of the beams with the new shear connection were found to be essentially the same as that of the specimen with standard shear studs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

More and more, integral abutment bridges are being used in place of the more traditional bridge designs with expansion releases. In this study, states which use integral abutment bridges were surveyed to determine their current practice in the design of these structures. To study piles in integral abutment bridges, a finite element program for the soil-pile system was developed (1) with materially and geometrically nonlinear, two and three dimensional beam elements and (2) with a nonlinear, Winkler soil model with vertical, horizontal, and pile tip springs. The model was verified by comparison to several analytical and experimental examples. A simplified design model for analyzing piles in integral abutment bridges is also presented. This model grew from previous analytical models and observations of pile behavior. The design model correctly describes the essential behavioral characteristics of the pile and conservatively predicts the vertical load-carrying capacity. Analytical examples are presented to illustrate the effects of lateral displacements on the ultimate load capacity of a pile. These examples include friction and end-bearing piles; steel, concrete, and timber piles; and bending about the weak, strong, and 45° axes for H piles. The effects of cyclic loading are shown for skewed and nonskewed bridges. The results show that the capacity of friction piles is not significantly affected by lateral displacements, but the capacity of end-bearing piles is reduced. Further results show that the longitudinal expansion of the bridge can introduce a vertical preload on the pile.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

During the harvest season in Iowa, it is common to have single axle loads on secondary roads and bridges that are excessive (typical examples are grain carts) and well beyond normal load limits. Even though these excessive loads occur only during a short time of the year, they may do significant damage to pavements and bridges. In addition, the safety of some bridges may be compromised because of the excessive loads, and sometimes there may be little indication to the users that damage may be imminent. At this time there are no Iowa laws regulating axle loads allowed for agricultural equipment. This study looks at the potential problems this may cause on secondary roads and timber stringer bridges. Both highway pavement and timber bridges are evaluated in this report. A section (panel) of Iowa PCC paved county road was chosen to study the effects of heavy agricultural loads on pavements. Instrumentation was applied to the panel and a heavily loaded grain cart was rolled across. The collected data were analyzed for any indication of excessive stresses of the concrete. The second study, concerning excessive loads on timber stringer bridges, was conducted in the laboratory. Four bridge sections were constructed and tested. Two of the sections contained five stringers and two sections had three stringers. Timber for the bridges came from a dismantled bridge, and deck panels were cut from new stock. All timber was treated with creosote. A hydraulic load was applied at the deck mid-span using a foot print representing a tire from a typical grain cart. Force was applied until failure of the system resulted. The collected data were evaluated to provide indications of load distribution and for comparison with expected wheel loads for a typical heavily loaded single axle grain cart. Results of the pavement tests showed that the potential of over-stressing the pavement is a possibility. Even though most of the tension stress levels recorded were below the rupture strength of the concrete, there were a few instances where the indicated tension stress level exceeded the concrete rupture strength. Results of the bridge tests showed that when the static ultimate load capacity of the timber stringer bridge sections was reached, there was sudden loss of capacity. Prior to reaching this ultimate capacity, the load sharing between the stringers was very uniform. The failure was characterized by loss of flexural capacity of the stringers. In all tests, the ultimate test load exceeded the wheel load that would be applied by an 875 bushel single axle grain cart.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tässä työssä tutkittiin Ruukin valmistamista lujista Optim 700 MC Plus sekä Optim 700 QL teräksistä tehtyjen hitsattujen palkkirakenteiden vikasietoisuutta sekä murtumiskäyttäytymistä laboratoriossa suoritettujen täyden mittakaavan kokeiden avulla. Koerakenteet suunniteltiin siten, että rakenteen kylmämuovauksen sekä hitsauksen vaikutukset yhdessä rakenteen geometrian vaikutuksen kanssa heikentävät rakenteen murtumissitkeyttä rakenteeseen tehdyn teräväkärkisen alkusärön tasossa. Suunnitellussa koesarjassa varioidaan testauslämpötilan lisäksi hitsauksen lämmöntuontia sekä koerakenteeseen tehtävän alkusärön kokoa. Tässä työssä tavoitteena oli yleisesti esittää menettely hitsatun säröllisen teräsrakenteen kestävyyden arviointia varten. Optim 700 MC Plus teräksestä tehdyn koerakenteen käyttäytymistä tutkittiin laskennallisesti murtumismekaniikan avulla. Laadittujen FEM - mallien avulla laskettiin rakenteen murtumisparametrien arvot kummallekin tutkittavalle teräkselle. Optim 700 MC Plus materiaalista valmistetuille koerakenteen säröalueen rakennedetaljia vastaavalle koekappaleille suoritettiin murtumissitkeyskokeita. Murtumissitkeyskokeista saatujen tulosten avulla pystyttiin kuvaamaan täyden mittakaavan koerakenteessa olevan särön murtumiskäyttäytymistä mitoitusmenetelmissä. Koerakenteelle laskettiin tässä työssä kriittisen särökoon ja sitä vastaavan kuorman arvot perustuen rakenteen oletettuun hauraaseen, epästabiiliin sitkeään sekä plastiseen murtumiskäyttäytymiseen. Tässä työssä testattiin molemmista tutkittavista materiaaleista valmistetut täyden mittakaavan koerakenteet -40 °C lämpötilassa. Molemmat testatut rakenteet käyttäytyvät mitattujen siirtymätulosten perusteella melko hauraasti. Optim 700 MC Plus materiaalille saatujen laskentatulosten voidaan todeta testatun koekappaleen perusteella soveltuvan hauraasti käyttäytyvän rakenteen mitoitukseen.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We microscopically and mechanically evaluated the femurs of rats subjected to hindlimb unloading (tail suspension) followed by treadmill training. Female Wistar rats were randomly divided into five groups containing 12-14 rats: control I (118 days old), control II (139 days old), suspended (tail suspension for 28 days), suspended-released (released for 21 days after 28 days of suspension), and suspended-trained (trained for 21 days after 28 days of suspension). We measured bone resistance by bending-compression mechanical tests of the entire proximal half of the femur and three-point bending tests of diaphyseal cortical bone. We determined bone microstructure by tetracycline labeling of trabecular and cortical bone. We found that tail suspension weakened bone (ultimate load = 86.3 ± 13.5 N, tenacity modulus = 0.027 ± 0.011 MPa·m vs ultimate load = 101.5 ± 10.5 N, tenacity modulus = 0.019 ± 0.006 MPa·m in control I animals). The tenacity modulus for suspended and released animals was 0.023 ± 0.010 MPa·m vs 0.046 ± 0.018 MPa·m for trained animals and 0.035 ± 0.010 MPa·m for control animals. These data indicate that normal activity and training resulted in recovered bone resistance, but suspended-released rats presented femoral head flattening and earlier closure of the growth plate. Microscopically, we found that suspension inhibited new bone subperiosteal and endosteal formation. The bone disuse atrophy secondary to hypoactivity in rats can be reversed by an early regime of exercising, which is more advantageous than ordinary cage activities alone.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Warships are generally sleek, slender with V shaped sections and block coefficient below 0.5, compared to fuller forms and higher values for commercial ships. They normally operate in the higher Froude number regime, and the hydrodynamic design is primarily aimed at achieving higher speeds with the minimum power. Therefore the structural design and analysis methods are different from those for commercial ships. Certain design guidelines have been given in documents like Naval Engineering Standards and one of the new developments in this regard is the introduction of classification society rules for the design of warships.The marine environment imposes subjective and objective uncertainties on ship structure. The uncertainties in loads, material properties etc.,. make reliable predictions of ship structural response a difficult task. Strength, stiffness and durability criteria for warship structures can be established by investigations on elastic analysis, ultimate strength analysis and reliability analysis. For analysis of complicated warship structures, special means and valid approximations are required.Preliminary structural design of a frigate size ship has been carried out . A finite element model of the hold model, representative of the complexities in the geometric configuration has been created using the finite element software NISA. Two other models representing the geometry to a limited extent also have been created —- one with two transverse frames and the attached plating alongwith the longitudinal members and the other representing the plating and longitudinal stiffeners between two transverse frames. Linear static analysis of the three models have been carried out and each one with three different boundary conditions. The structural responses have been checked for deflections and stresses against the permissible values. The structure has been found adequate in all the cases. The stresses and deflections predicted by the frame model are comparable with those of the hold model. But no such comparison has been realized for the interstiffener plating model with the other two models.Progressive collapse analyses of the models have been conducted for the three boundary conditions, considering geometric nonlinearity and then combined geometric and material nonlinearity for the hold and the frame models. von Mises — lllyushin yield criteria with elastic-perfectly plastic stress-strain curve has been chosen. ln each case, P-Delta curves have been generated and the ultimate load causing failure (ultimate load factor) has been identified as a multiple of the design load specified by NES.Reliability analysis of the hull module under combined geometric and material nonlinearities have been conducted. The Young's Modulus and the shell thickness have been chosen as the variables. Randomly generated values have been used in the analysis. First Order Second Moment has been used to predict the reliability index and thereafter, the probability of failure. The values have been compared against standard values published in literature.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

At the Institute of Structural Engineering of the Faculty of Civil Engineering, Kassel University, series tests of slab-column connection were carried out, subjected to concentrated punching load. The effects of steel fiber content, concrete compressive strength, tension reinforcement ratio, size effect, and yield stress of tension reinforcement were studied by testing a total of six UHPC slabs and one normal strength concrete slab. Based on experimental results; all the tested slabs failed in punching shear as a type of failure, except the UHPC slab without steel fiber which failed due to splitting of concrete cover. The post ultimate load-deformation behavior of UHPC slabs subjected to punching load shows harmonic behavior of three stages; first, drop of load-deflection curve after reaching maximum load, second, resistance of both steel fibers and tension reinforcement, and third, pure tension reinforcement resistance. The first shear crack of UHPC slabs starts to open at a load higher than that of normal strength concrete slabs. Typically, the diameter of the punching cone for UHPC slabs on the tension surface is larger than that of NSC slabs and the location of critical shear crack is far away from the face of the column. The angle of punching cone for NSC slabs is larger than that of UHPC slabs. For UHPC slabs, the critical perimeter is proposed and located at 2.5d from the face of the column. The final shape of the punching cone is completed after the tension reinforcement starts to yield and the column stub starts to penetrate through the slab. A numerical model using Finite Element Analysis (FEA) for UHPC slabs is presented. Also some variables effect on punching shear is demonstrated by a parametric study. A design equation for UHPC slabs under punching load is presented and shown to be applicable for a wide range of parametric variations; in the ranges between 40 mm to 300 mm in slab thickness, 0.1 % to 2.9 % in tension reinforcement ratio, 150 MPa to 250 MPa in compressive strength of concrete and 0.1 % to 2 % steel fiber content. The proposed design equation of UHPC slabs is modified to include HSC and NSC slabs without steel fiber, and it is checked with the test results from earlier researches.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

El uso de materiales compuestos de matriz polimérica (FRP) emerge como alternativa al hormigón convencionalmente armado con acero debido a la mayor resistencia a la corrosión de dichos materiales. El presente estudio investiga el comportamiento en servicio de vigas de hormigón armadas con barras de FRP mediante un análisis teórico y experimental. Se presentan los resultados experimentales de veintiséis vigas de hormigón armadas con barras de material compuesto de fibra de vidrio (GFRP) y una armada con acero, todas ellas ensayadas a flexión de cuatro puntos. Los resultados experimentales son analizados y comparados con algunos de los modelos de predicción más significativos de flechas y fisuración, observándose, en general, una predicción adecuada del comportamiento experimental hasta cargas de servicio. El análisis de sección fisurada (CSA) estima la carga última con precisión, aunque se registra un incremento de la flecha experimental para cargas superiores a las de servicio. Esta diferencia se atribuye a la influencia de las deformaciones por esfuerzo cortante y se calcula experimentalmente. Se presentan los aspectos principales que influyen en los estados límites de servicio: tensiones de los materiales, ancho máximo de fisura y flecha máxima permitida. Se presenta una metodología para el diseño de dichos elementos bajo las condiciones de servicio. El procedimiento presentado permite optimizar las dimensiones de la sección respecto a metodologías más generales.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O objetivo da presente investigação experimental foi avaliar o perfil mecânico de três tipos de técnicas de sutura entre tendões de dimensões diferentes. Foram utilizados 21 cães sem raça definida (11machos/10 fêmeas), dos quais foram obtidos os tendões flexor comum dos dedos - t.c. (maior dimensão) e tibial cranial - t.cr. (menor dimensão), de ambos os membros pélvicos. Logo após a obtenção das peças foi realizada sutura, segundo cada tipo de técnica, porém sempre com o mesmo número de pontos. Os tendões utilizados para sutura foram sempre do lado direito e o controle do lado esquerdo (t.cr.). Após a sutura, os corpos de prova foram fixados em garras especialmente desenvolvidas e submetidos a ensaio de tração axial à velocidade de 30mm/minuto. Após o ensaio o programa da máquina forneceu os valores da carga máxima ( na ruptura) e deformação absoluta (mm) e relativa (%), além do diagrama carga-deformação. Os resultados foram submetidos a estudo estatístico pela análise de medidas repetidas no nível de 5% de significância. Não foi constatada diferença estatisticamente significativa nos parâmetros mecânicos avaliados nos três grupos de técnicas de suturas. em relação ao controle (tendão de menos diâmetro contra-lateral), observou-se que a sutura apresenta resistência máxima a tração significativamente menor que o controle e maior deformação.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Com a finalidade de se comparar as propriedades mecânicas do ligamento da patela e do tendão calcâneo foram realizados ensaios de tração em material obtido de 25 cadáveres humanos. A idade dos doadores foi 58 ± 14 anos (33-85), sendo 19 (76%) masculinos e 6 (24%) femininos, 23 brancos (92%) e dois negros (8%). Os materiais foram testados em seus 10 mm centrais, com velocidade de aplicação de carga de 30 mm/min. Foi obtida a área de secção dos corpos de prova para que fossem estudadas as propriedades estruturais e materiais. Foram estudadas as seguintes variáveis: carga máxima (N), tensão(MPa), módulo de elasticidade (MPa), energia (Nm), alongamento absoluto (mm) e específico (%), limite de proporcionalidade (N), além da tensão (MPa) e alongamentos neste ponto. A análise estatística revelou que ambos possuem carga máxima, limite de proporcionalidade e tensão semelhantes (p>0,05). Nas outras variáveis ocorreu diferença significativa (p<0,05) com o tendão calcâneo apresentando valores maiores para energia e alongamento. O módulo de elasticidade, significativamente maior no ligamento da patela (p<0,05), foi a variável que melhor caracterizou a diferença do comportamento mecânico dos dois materiais.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The folded plate girder, a newly proposed bridge girder, is investigated through this thesis. The folded plate girder is cold bent out of a single sheet of steel. The cold bending eliminates the costly and inconsistent shop welds found in traditional girders. The folded plate girder is meant for application in short span bridges. The girder was subjected to an equivalent 75 year lifetime loading to investigate the fatigue performance. The rebar detail used in the closure region between adjacent slabs has been investigated in the past by the NCHRP 12-68 project. This thesis will proposes a hooked rebar detail as a cost effective alternative to the previously recommended headed rebar detail. The proposed hooked rebar detail looks to improve upon the headed bar detail by increasing the clear cover, and reducing the cost of fabrication and shipment of the rebar. Six specimens containing closure regions are subjected to both positive and negative moment loading in order to investigate their behavior and failure modes under ultimate load.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Masonry spandrels together with shear walls are structural components of a masonry building subjected to lateral loads. Shear walls are the main components of this structural system, even if masonry spandrels are the elements that ensure the connection of shear wall panels and the distribution of stresses through the masonry piers. The use of prefabricated truss type bars in the transversal and longitudinal directions is usually considered a challenge, even if the simplicity of the applications suggested here alleviate some of the possible difficulties. This paper focus on the experimental behavior of masonry spandrels reinforced with prefabricated trusses, considering different possibilities for the arrangement of reinforcement and blocks. Reinforced spandrels with three and two hollow cell concrete blocks and with different reinforcement ratios have been built and tested using a four and three point loading test configuration. Horizontal bed joint reinforcement increased the capacity of deformation as well as the ultimate load, leading to ductile responses. Vertical reinforcement increased the shear strength of the masonry spandrels and its distribution play a central role on the shear behavior. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study wants to analyze the effectiveness of different reinforcement typologies for masonry columns, in particular Fiber-Reinforced Polymer (FRP) and FRCM. The behavior of 10 solid – brick columns that are externally wrapped by FRP sheets and 2 unreinforced columns are presented in this study. The specimens are subjected to axial load until failure occurs. Three different confinement schemes were experimentally analyzed in order to evaluate and compare the effectiveness of the proposed strengthening techniques: 1) Grid carbon FRP (CFRP_G); 2) Grid glass FRP (GFRP_G); 3) Uniaxial carbon FRP (CFRP_U). Two different configurations of the reinforcing system were investigated: FRP sheets are applied as external reinforcement along the perimeter of the masonry columns in the form of continuous and discontinuous wrap, respectively. The results, compared with those for un-reinforced columns, indicate an increases in ultimate load, stiffness and ductility.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In dentistry the restoration of decayed teeth is challenging and makes great demands on both the dentist and the materials. Hence, fiber-reinforced posts have been introduced. The effects of different variables on the ultimate load on teeth restored using fiber-reinforced posts is controversial, maybe because the results are mostly based on non-standardized in vitro tests and, therefore, give inhomogeneous results. This study combines the advantages of in vitro tests and finite element analysis (FEA) to clarify the effects of ferrule height, post length and cementation technique used for restoration. Sixty-four single rooted premolars were decoronated (ferrule height 1 or 2 mm), endodontically treated and restored using fiber posts (length 2 or 7 mm), composite fillings and metal crowns (resin bonded or cemented). After thermocycling and chewing simulation the samples were loaded until fracture, recording first damage events. Using UNIANOVA to analyze recorded fracture loads, ferrule height and cementation technique were found to be significant, i.e. increased ferrule height and resin bonding of the crown resulted in higher fracture loads. Post length had no significant effect. All conventionally cemented crowns with a 1-mm ferrule height failed during artificial ageing, in contrast to resin-bonded crowns (75% survival rate). FEA confirmed these results and provided information about stress and force distribution within the restoration. Based on the findings of in vitro tests and computations we concluded that crowns, especially those with a small ferrule height, should be resin bonded. Finally, centrally positioned fiber-reinforced posts did not contribute to load transfer as long as the bond between the tooth and composite core was intact.