955 resultados para Uasb reactors


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Pós-graduação em Microbiologia Agropecuária - FCAV

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Pós-graduação em Microbiologia Agropecuária - FCAV

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The present work evaluated the performance of two treatment systems in reducing indicators of biological contamination in swine production wastewater. System I consisted of two upflow anaerobic sludge blanket (UASB) reactors, with 510 and 209 L in volume, being serially arranged. System II consisted of a UASB reactor, anaerobic filter, trickling filter, and decanter, being also organized in series, with volumes of 300, 190, 250, and 150 L, respectively. Hydraulic retention times (HRT) applied in the first UASB reactors were 40, 30, 20, and 11 h in systems I and II. The average removal efficiencies of total and thermotolerant coliforms in system I were 92.92% to 99.50% and 94.29% to 99.56%, respectively, and increased in system II to 99.45% to 99.91% and 99.52% to 99.93%, respectively. Average removal rates of helminth eggs in system I were 96.44% to 99.11%, reaching 100% as in system II. In reactor sludge, the counts of total and thermotolerant coliforms ranged between 10(5) and 10(9) MPN (100 mL)(-1), while helminth eggs ranged from 0.86 to 9.27 eggs g(-1) TS.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The stabilization of swine wastewaters from swine confined housing by the combination of a upflow anaerobic sludge blanket (UASB) reactor and waste stabilization ponds is a viable alternative to minimize the environmental impact caused by inadequate disposal of swine wastewaters. In the present study, the polluting load of pre-decanted swine wastewater treated with a series of two 0.705 m(3) UASB reactors and then in parallel in aerated and non-aerated stabilization tanks was investigated from January to July, 2000. Physicochemical and microbiological analyses were made adopting standard methods (Standard Methods for Examination of Water and Wastewater, 19th ed., American Public Health Association, Washington, DC, 1995). COD values decreased as the wastewater ran through the integrated biodigestion system dropping from about 3492 +/- 511-4094 mg l(-1) +/- 481 to 124 +/- 52-490 mg l(-1) +/- 230, while nitrate and nitrite levels increased in stabilization tanks, ranging respectively from 4 +/- 0 to 20 mg l(-1) +/- 3 and 3 +/- 1 to 11 mg l(-1) +/- 24. Although the removal of Escherichia coli was more than 97% +/- 6, the effluents of the treatment system still contained unacceptable levels of E. coli (1.6 x 10(3)-1.2 x 10(6) 100 ml(-1)) according to WHO guidelines for use of wastewater in agriculture and aquaculture. These results indicate the necessity of changes on operational characteristics of the treatment system such as an increase of the hydraulic retention time in UASB reactors or in stabilization tanks. (C) 2003 Published by Elsevier Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Microbiologia Agropecuária - FCAV

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study aimed to develop, implement and evaluate the performance of a new type of bioreactor for anaerobic treatment of wastewater using different filling materials like trickling filters post-reactor. This bioreactor has mixed characteristics of the UASB reactors and horizontal flow from the point of view of removal of BOD (Biochemical Oxygen Demand) ssed (settled solids), TS (Total Solids), SS (Suspended Solid), SD (Dissolved Solids) and turbidity. The experimental model consists of a bioreactor with a volume of 12 m³, 2/3 filled by fluidized bed and 1/3 for fixed. The fluidized bed is made of polystyrene plates used as a system percolation and compartmentalized trickling filters, where each compartment was filled with a support medium with different characteristics (gravel number 4, plastic rings of polystyrene, PET and HDPE) . In addition, the output of a filter system was installed three entries filled with activated carbon. The bioreactor was installed in private residence in the city of Igarapava-SP (20° 02'40.18"S and 47° 45'01.36" W). The system was highly efficient as the removal of organic contaminant load 92% on average reducing the BOD, a significant result when compared to other anaerobic systems. For the other parameters, the mean reduction was 96% for turbidity, 99% ssed, 67.5% ST, 57% SD and 88% of SS. As for its operation the system was capable of operating in continuous flow without the need for maintenance during the entire period of evaluation and without energy, as it operates taking advantage of the natural slope of the terrain where it is installed. The environmental impacts were minimized due to the preservation of local vegetation allowing the ecosystem to remain unchanged beyond the prototype was completely sealed preventing exhalation of odors and therefore not causing inconvenience to neighboring populations. Given these facts it was concluded that the prototype is shown to be highly feasible deployed as a new alternative for treatment of sewage in rural and urban settings (individual homes, condos, farms, ranches, etc.) Due to ease of design and operability, and sustainability at all stages of execution.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Microbiologia Agropecuária - FCAV

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study evaluated linear alkylbenzene sulfonate removal in an expanded granular sludge bed reactor with hydraulic retention times of 26 h and 32 h. Sludge bed and separator phase biomass were phylogenetically characterized (sequencing 16S rRNA) and quantified (most probable number) to determine the total anaerobic bacteria and methanogenic Archaea. The reactor was fed with a mineral medium supplemented with 14 mg l(-1) LAS, ethanol and methanol. The stage I-32 h consisted of biomass adaptation (without LAS influent) until reactor stability was achieved (COD removal >97%). In stage II-32 h, LAS removal was 74% due to factors such as dilution, degradation and adsorption. Higher HRT values increased the LAS removal (stage III: 26 h - 48% and stage IV: 32 h - 64%), probably due to increased contact time between the biomass and LAS. The clone libraries were different between samples from the sludge bed (Synergitetes and Proteobacteria) and the separator phase (Firmicutes and Proteobacteria) biomass. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Debido al aumento de los estándares de calidad exigidos internacionalmente, así como por una mayor presión sobre la industria mediante legislaciones ambientales más rigurosas, el sector cafetalero está obligado a buscar, a través de la investigación, un sistema adecuado de tratamiento para las aguas residuales generadas en el beneficiado húmedo del café. En este trabajo se evaluó el funcionamiento de la digestión anaerobia para el tratamiento de las aguas residuales de despulpe. Para ello, se utilizaron dos sistemas anaerobios, uno en una etapa (UASB), y otro con separación de fases (2PUASB). Se investigó el efecto en la digestión anaerobia de tres cargas orgánicas volumétricas (OLR) y de las dos configuraciones de reactor usadas. Los valores de OLR de operación en el sistema UASB variaron en un intervalo de 3.6-4.1 kgCOD m-3 d-1, con una tasa de recirculación del efluente de 1.0. El sistema 2PUASB fue alimentado con OLR similares a las que se emplearon en el sistema en una etapa. El reactor de acidificación fue cargado a 11.0 kgCOD m-3 d-1, mientras que en el reactor metanogénico varió en el intervalo de 2.6-4.67 kgCOD m-3 d-1. El uso de reactores UASB en una etapa y en dos fases, bajo las mismas condiciones de operación ya descritas, propiciaron el logro de una eficiencia de degradación de COD total superior al 75% y al 85% para la COD soluble, respectivamente. Sin embargo, el sistema en dos fases mostró mejores resultados en el tratamiento de este tipo de agua residual, no solo en cuanto a eficiencia de eliminación de la carga orgánica contaminante así como una menor concentración de ácidos grasos volátiles (VFA) en el efluente. Obtenidas las mejores condiciones de trabajo, fue evaluada la separación de fases bajo el efecto de la recirculación. Los grupos de fermentaciones producidos fueron similares a los obtenidos en el experimento sin recirculación, indicando que está última no afectó la composición relativa de los VFA del reactor anaerobio, por lo que no cambió el patrón de degradación del residuo. Una tasa de recirculación de 1.0 del efluente del reactor metanogénico al reactor acidogénico mejoró significativamente el proceso, ya que se incrementó la conversión de los VFA (31%), la eliminación de la fracción total y soluble del residuo tratado (6.5%) y la reducción del consumo de alcalinizante (39%); manteniendo similares producciones de metano. El uso de la digestión anaerobia en dos fases demostró una mejora en la estabilidad del proceso y un incremento de la eficiencia de operación y de la producción de metano, respectivamente.Tesis Doctoral Yans Guardia Puebla Abstract ix ABSTRACT Due to the increase of quality standards internationally demanded, as well as for a greater pressure on the industry by means of more rigorous environmental legislations, the coffee sector is forced to search, through the research, an appropriated treatment system for coffee wet wastewaters generated. In this work the performance of the anaerobic digestion for the coffee wet wastewater treatment was evaluated. For it, two anaerobic systems, one in single-stage (UASB), and another with two-phase (2PUASB) were used. The effect in the anaerobic digestion of three organic loading rates (OLR) and of two reactor configurations used was investigated. OLR operation values in UASB system varied in an interval of 3.6-4.1 kgCOD m-3 d-1, with a recycle rate of the effluent of 1.0. 2PUASB system was fed with OLR similar to those that were used in the reactor in a stage. The acidification reactor was loaded to 11.0 kgCOD m-3 d-1, whereas in the methanogenic reactor varied in the interval of 2.6-4.67 kgCOD m-3 d-1. The use of single-stage and two-phase UASB reactors, under the same operation conditions already before described, a total COD removal efficiency of 75% and 85% for the soluble COD removal efficiency, respectively, was achieved. However, two-phase system showed better results in the treatment of this wastewater type, not only as for removal efficiency of loading organic polluting as well as a smaller volatile fatty acid (VFA) concentration in the effluent. Obtained the best work conditions, the two-phase system under the effect of the recycle was evaluated. Fermentations groups produced were similar to those obtained in the experiment without recycle, indicating that it last one do not affect the relative composition of VFA of the anaerobic reactor, for that reason the degradation pattern of the residue does not change. A recycle rate of 1.0 of the effluent of the methanogenic reactor to the acidogenic reactor improved the process significantly, since it was increased the VFA conversion (31%), the removal of total and soluble fraction of the residue treated (6.5%) and the decrease of the alkalinity consumption (39%); maintaining similar methane productions. The use of the two-phase anaerobic digestion demonstrated to an improvement in the stability of the process and an increase of the operation efficiency and methane production, respectively.