981 resultados para UPPER EXTREMITY FUNCTION


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Although superficial thrombophlebitis of the upper extremity represents a frequent complication of intravenous catheters inserted into the peripheral veins of the forearm or hand, no consensus exists on the optimal management of this condition in clinical practice. OBJECTIVES To summarise the evidence from randomised clinical trials (RCTs) concerning the efficacy and safety of (topical, oral or parenteral) medical therapy of superficial thrombophlebitis of the upper extremity. SEARCH METHODS The Cochrane Vascular Group Trials Search Co-ordinator searched the Specialised Register (last searched April 2015) and the Cochrane Register of Studies (2015, Issue 3). Clinical trials registries were searched up to April 2015. SELECTION CRITERIA RCTs comparing any (topical, oral or parenteral) medical treatment to no intervention or placebo, or comparing two different medical interventions (e.g. a different variant scheme or regimen of the same intervention or a different pharmacological type of treatment). DATA COLLECTION AND ANALYSIS We extracted data on methodological quality, patient characteristics, interventions and outcomes, including improvement of signs and symptoms as the primary effectiveness outcome, and number of participants experiencing side effects of the study treatments as the primary safety outcome. MAIN RESULTS We identified 13 studies (917 participants). The evaluated treatment modalities consisted of a topical treatment (11 studies), an oral treatment (2 studies) and a parenteral treatment (2 studies). Seven studies used a placebo or no intervention control group, whereas all others also or solely compared active treatment groups. No study evaluated the effects of ice or the application of cold or hot bandages. Overall, the risk of bias in individual trials was moderate to high, although poor reporting hampered a full appreciation of the risk in most studies. The overall quality of the evidence for each of the outcomes varied from low to moderate mainly due to risk of bias and imprecision, with only single trials contributing to most comparisons. Data on primary outcomes improvement of signs and symptoms and side effects attributed to the study treatment could not be statistically pooled because of the between-study differences in comparisons, outcomes and type of instruments to measure outcomes.An array of topical treatments, such as heparinoid or diclofenac gels, improved pain compared to placebo or no intervention. Compared to placebo, oral non-steroidal anti-inflammatory drugs reduced signs and symptoms intensity. Safety issues were reported sparsely and were not available for some interventions, such as notoginseny creams, parenteral low-molecular-weight heparin or defibrotide. Although several trials reported on adverse events with topical heparinoid creams, Essaven gel or phlebolan versus control, the trials were underpowered to adequately measure any differences between treatment modalities. Where reported, adverse events with topical treatments consisted mainly of local allergic reactions. Only one study of 15 participants assessed thrombus extension and symptomatic venous thromboembolism with either oral non-steroidal anti-inflammatory drugs or low-molecular-weight heparin, and it reported no cases of either. No study reported on the development of suppurative phlebitis, catheter-related bloodstream infections or quality of life. AUTHORS' CONCLUSIONS The evidence about the treatment of acute infusion superficial thrombophlebitis is limited and of low quality. Data appear too preliminary to assess the effectiveness and safety of topical treatments, systemic anticoagulation or oral non-steroidal anti-inflammatory drugs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Quantitative measures of human movement quality are important for discriminating healthy and pathological conditions and for expressing the outcomes and clinically important changes in subjects' functional state. However the most frequently used instruments for the upper extremity functional assessment are clinical scales, that previously have been standardized and validated, but have a high subjective component depending on the observer who scores the test. But they are not enough to assess motor strategies used during movements, and their use in combination with other more objective measures is necessary. The objective of the present review is to provide an overview on objective metrics found in literature with the aim of quantifying the upper extremity performance during functional tasks, regardless of the equipment or system used for registering kinematic data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Forearm support during keyboard use has been reported to reduce neck and shoulder muscle activity and discomfort. However, the effect of forearm support on wrist posture has not been examined. The aim of this study was to examine the effect of 3 different postures during keyboard use: forearm support, wrist support and floating. The floating posture (no support) was used as the reference condition. A wrist rest was present in all test conditions. Thirteen participants completed 20 min wordprocessing tasks in each of the test conditions. Electromyography was used to monitor neck, shoulder and forearm muscle activity. Bilateral and overhead video cameras recorded left and right wrist extension, shoulder and elbow flexion and radial and ulnar deviation. The forearm support condition resulted in significantly less ulnar deviation (

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background General anaesthesia and regional anaesthesia have been used successfully for upper extremity orthopaedic procedures. Despite the advantages of regional anaesthesia, there is low utilisation in Nigeria. In this study, we assessed the types of anaesthesia employed for upper extremity surgeries in our centre. Methods After obtaining approval from the institutional ethics committee, all the patients who had upper extremity surgeries from 1 January 2011 to 31 December 2012 were included in this review. Both prospective and retrospective data were gathered. The choice of anaesthesia was at the discretion of the attending anaesthetist. Results A total of 226 patients with a male-to-female ratio of 1.6:1 and median age of 35.0 (range 2 – 89) years, had orthopaedic upper extremity procedures during the study period. Sixty-three cases (27.9%) had general anaesthesia, 5 (2.2%) combined regional and general anaesthesia while 158 (69.9%) had regional blocks. The regional blocks comprised 145 (89%) different approaches to the brachial plexus and 18 (11%) local anaesthetic infiltrations. The arm was the site mostly operated upon; while supraclavicular and axillary brachial plexus blocks were performed in equal amounts. In 14 (6.2%) patients, brachial plexus blocks were performed with spinal anaesthesia because of concomitant iliac crest bone grafts. While the duration of surgery did not differ significantly, regional anaesthesia provided a significantly longer duration of anaesthesia than general anaesthesia (251 ± 70.8 min versus 141.3 ± 65.5 min; p = 0.0000001). Conclusion There is a high use of regional anaesthesia for upper extremity orthopaedic surgeries in our centre, which is a positive development in a resource limited setting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Manual dexterity, a prerogative of primates, is under the control of the corticospinal (CS) tract. Because 90-95% of CS axons decussate, it is assumed that this control is exerted essentially on the contralateral hand. Consistently, unilateral lesion of the hand representation in the motor cortex is followed by a complete loss of dexterity of the contralesional hand. During the months following lesion, spontaneous recovery of manual dexterity takes place to a highly variable extent across subjects, although largely incomplete. In the present study, we tested the hypothesis that after a significant postlesion period, manual performance in the ipsilesional hand is correlated with the extent of functional recovery in the contralesional hand. To this aim, ten adult macaque monkeys were subjected to permanent unilateral motor cortex lesion. Monkeys' manual performance was assessed for each hand during several months postlesion, using our standard behavioral test (modified Brinkman board task) that provides a quantitative measure of reach and grasp ability. The ipsilesional hand's performance was found to be significantly enhanced over the long term (100-300 days postlesion) in six of ten monkeys, with the six exhibiting the best, though incomplete, recovery of the contralesional hand. There was a statistically significant correlation (r = 0.932; P < 0.001) between performance in the ipsilesional hand after significant postlesion period and the extent of recovery of the contralesional hand. This observation is interpreted in terms of different possible mechanisms of recovery, dependent on the recruitment of motor areas in the lesioned and/or intact hemispheres.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Researchers in the rehabilitation engineering community have been designing and developing a variety of passive/active devices to help persons with limited upper extremity function to perform essential daily manipulations. Devices range from low-end tools such as head/mouth sticks to sophisticated robots using vision and speech input. While almost all of the high-end equipment developed to date relies on visual feedback alone to guide the user providing no tactile or proprioceptive cues, the “low-tech” head/mouth sticks deliver better “feel” because of the inherent force feedback through physical contact with the user's body. However, the disadvantage of a conventional head/mouth stick is that it can only function in a limited workspace and the performance is limited by the user's strength. It therefore seems reasonable to attempt to develop a system that exploits the advantages of the two approaches: the power and flexibility of robotic systems with the sensory feedback of a headstick. The system presented in this paper reflects the design philosophy stated above. This system contains a pair of master-slave robots with the master being operated by the user's head and the slave acting as a telestick. Described in this paper are the design, control strategies, implementation and performance evaluation of the head-controlled force-reflecting telestick system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a virtual headstick system as an alternative to the conventional passive headstick for persons with limited upper extremity function. The system is composed of a pair of kinematically dissimilar master-slave robots with the master robot being operated by the user's head. At the remote site, the end-effector of the slave robot moves as if it were at the tip of an imaginary headstick attached to the user's head. A unique feature of this system is that through force-reflection, the virtual headstick provides the user with proprioceptive information as in a conventional headstick, but with an augmentation of workspace volume and additional mechanical power. This paper describes the test-bed development, system identification, bilateral control implementation, and system performance evaluation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: The Constraint-induced Movement Therapy (CIMT) is a therapeutic program which main goal is the functional recuperation of paretic upper extremity of stroke patients with motor deficits by an intensive treatment, practice of functional repetition and wear of restriction in non-paretic during 90% of the daily hours. Objective: The aim of this study was evaluate the CIMT influence on upper extremity function of hemiparetic individuals. Method: The CIMT was provided for 3 daily hours for 10 consecutive days. Besides, patients were asked to wear a restraint dispositive on the unaffected hand during 90% of their activities daily living hours. Before and after the intervention period, 2 tests were administered to evaluate motor function, the Motor Activity Log (MAL) and the Wolf Motor Function Test (WMFT). Results: The results of MAL showed significant difference in quantity (p=0,011) and quality (p=0,016) of paretic upper extremity movements. Analysis of WMFT indicated a significant reduction of time that patients performed the tasks (p= 0,042) and a difference for quality of movement (p<0,0001). Conclusion: The present results showed that CIMT improves upper extremity function in hemiparetic individuals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To validate the unidimensionality of the Action Research Arm Test (ARAT) using Mokken analysis and to examine whether scores of the ARAT can be transformed into interval scores using Rasch analysis. Subjects and methods: A total of 351 patients with stroke were recruited from 5 rehabilitation departments located in 4 regions of Taiwan. The 19-item ARAT was administered to all the subjects by a physical therapist. The data were analysed using item response theory by non-parametric Mokken analysis followed by Rasch analysis. Results: The results supported a unidimensional scale of the 19-item ARAT by Mokken analysis, with the scalability coefficient H = 0.95. Except for the item pinch ball bearing 3rd finger and thumb'', the remaining 18 items have a consistently hierarchical order along the upper extremity function's continuum. In contrast, the Rasch analysis, with a stepwise deletion of misfit items, showed that only 4 items (grasp ball'', grasp block 5 cm(3)'', grasp block 2.5 cm(3)'', and grip tube 1 cm(3)'') fit the Rasch rating scale model's expectations. Conclusion: Our findings indicated that the 19-item ARAT constituted a unidimensional construct measuring upper extremity function in stroke patients. However, the results did not support the premise that the raw sum scores of the ARAT can be transformed into interval Rasch scores. Thus, the raw sum scores of the ARAT can provide information only about order of patients on their upper extremity functional abilities, but not represent each patient's exact functioning.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To describe the preoperative upper limb lymphoscintigraphic pattern in women with breast cancer. Thirty-seven patients undergoing lymphoscintigraphy within 30 days of surgery were investigated. Lymphoscintigraphic studies of 37 upper limbs ipsilateral to surgery and 32 contralateral upper limbs were performed. The examination protocol consisted in obtaining static images of the upper limb in semi-flexion after 10 minutes, and 1 and 2 hours after subcutaneous injection of 1 mCi (37 MBq) of Tc-99m-dextran in the dorsum of the hand. The velocity of axillary lymph node visualization (I, visible at 10 minutes; II, 1 hour; III, 2 hours; and IV, invisible) and degree (intensity) of nodal uptake (a, marked; b, moderate; c,mild; and d, absent) were analyzed. Optimal lymphatic functional pattern (Ia) was observed in four (11%) patients, in the ipsilateral upper limb, and six (19%), in the contralateral upper limb. Worse condition was observed in three (8%) patients (IVd) in the ipsilateral upper limb and two (6%) patients in the contralateral upper limb. The remaining patients showed intermediate states of velocity and uptake intensity. This study found relevant changes in preoperative lymphoscintigraphy, demonstrating preexisting functional differences in the lymphatic system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Study design: Cross-sectional. Objective: To analyze the relationships between functional tests, arm strength and root mean square of surface electromyography (EMG). Setting: Sao Paulo, Brazil. Methods: Twenty-four individuals with chronic tetraplegia participated. Upper extremity motor score (UEMS), functional independence measure (FIM) motor score, spinal cord independence measure III and capabilities of upper extremity (CUE) were performed. Muscle strength of the right elbow flexors-extensors was assessed using dynamometry and manual muscle test (MMT) and EMG of right biceps and triceps brachii were performed. Spearman's rank correlation coefficients and Mann-Whitney's U-test were used. Results: Functional tests and UEMS correlated strongly among them. UEMS highly correlated with triceps dynamometry and EMG. The dynamometry showed a very high correlation with MMT on the extensor group and a moderate correlation with flexor group. Triceps EMG showed moderate correlation with FIM and CUE. High correlations between triceps EMG and elbow extensors dynamometry and MMT were observed. A significant better performance on functional tests was observed on lower ASIA motor levels. The low-tetraplegia group showed a significant higher score on triceps EMG and dynamometry. Conclusion: Arm strength and EMG seem to be related to functional capabilities and independence in chronic tetraplegia. Spinal Cord (2012) 50, 28-32; doi:10.1038/sc.2011.95; published online 30 August 2011

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Generally, quadriplegic individuals have difficulties performing object manipulation. Toward satisfactory manipulation, reach and grasp movements must be performed with voluntary control, and for that, grasp force feedback is essential. A hybrid system aiming at partial upper limb sensory-motor restoration for quadriplegics was built. Such device is composed of an elbow dynamic orthosis that provides elbow flexion/extension (range was approximately from 20 degrees to 120 degrees, and average angular speed was approximately 15 degrees/s) with forearm support, a wrist static orthosis and neuromuscular electrical stimulation for grasping generation, and a glove with force sensors that allows grasping force feedback. The glove presents two user interface modes: visual by light emitting diodes or audio emitted by buzzer. Voice control of the entire system (elbow dynamic orthosis and electrical stimulator) is performed by the patient. The movements provided by the hybrid system, combined with the scapular and shoulder movements performed by the patient, can aid quadriplegic individuals in tasks that involve reach and grasp movements.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The purpose of the present study was to evaluate the intra and interday reliability of surface electromyographic amplitude values of the scapular girdle muscles and upper limbs during 3 isometric closed kinetic chain exercises, involving upper limbs with the fixed distal segment extremity on stable base of support and on a Swiss ball (relatively unstable). Twenty healthy adults performed the exercises push-up, bench-press and wall-press with different effort levels (80% and 100% maximal load). Subjects performed three maximal voluntary contractions (MVC) in muscular testing position of each muscle to obtain a reference value for root mean square (RMS) normalization. Individuals were instructed to randomly perform three isometric contraction series, in which each exercise lasted 6 s with a 2-min resting-period between series and exercises. Intra and interday reliabilities were calculated through the intraclass correlation coefficient (ICC 2.1), standard error of the measurement (SEM). Results indicated an excellent intraday reliability of electromyographic amplitude values (ICC >= 0.75). The interday reliability of normalized RMS values ranged between good and excellent (ICC 0.52-0.98). Finally, it is suggested that the reliability of normalized electromyographic amplitude values of the analyzed muscles present better values during exercises on a stable surface. However, load levels used during the exercises do not seem to have any influence on variability levels, possibly because the loads were quite similar. (C) 2007 Elsevier Ltd. All rights reserved.