980 resultados para Tooth apex, anatomy
Resumo:
The aim of this study was to investigate the apical leakage of roots filled by three different gutta-percha techniques: lateral condensation, Tagger's hybrid and E&Q Master. Forty-two extracted single-rooted teeth were used. The coronal part of each tooth was removed and the root received biomechanical preparation using a 60-K file. The roots were randomly divided into three groups according to the technique of filling the root canal: Group I, lateral condensation; Group II, Tagger's hybrid; Group III, E&Q Master. The roots were submitted to dye leakage test with Rhodamine B for 7 days, using vacuum during the initial 30 min. The teeth were sectioned longitudinally and the leakage was measured in a linear fashion from apex to crown. Statistical analysis indicated that lateral condensation and E&Q Master techniques showed lower leakage than Tagger's technique (P = 0.0016). However, statistically no difference was found between lateral condensation and E&Q Master system techniques.
Resumo:
The purpose of this in vitro study was to evaluate the effect of neodymium:yttrium-aluminum-garnet (Nd:YAG) laser irradiation on intracanal dentin surface by SEM analysis and its interference in the apical seal of filled canals. After endodontic treatment procedures, 34 maxillary human incisors were randomly assigned to 2 groups. In the negative control group (n=17), no additional treatment was performed and teeth were filled with vertically condensed gutta-percha; in the laser-treated group (n=17), the root canals were irradiated with Nd:YAG laser (1.5 W, 100 mJ, 15 Hz) before filling as described for the control group. Two specimens of each group were prepared for SEM analysis to evaluate the presence and extent of morphological changes and removal of debris; the other specimens were immersed in 0.5% methylene blue dye (pH 7.2) for 24 h for evaluation of the linear dye leakage at the apical third. SEM analysis of the laser-treated group showed dentin fusion and resolidification without smear layer or debris. The Student's t-test showed that the laser-treated group had significantly less leakage in apical third than the control group. Within the limitations of this study, it may be concluded that the morphological changes on the apical intraradicular dentin surface caused by Nd:YAG laser resulted in less linear dye apical leakage.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective: This study has two aims: 1) to evaluate the apical transportation of the Wizard CD Plus and ProTaper Universal after preparation of simulated root canals; 2) to compare, with Adobe Photoshop, the ability of a new software (Regeemy) in superposing and subtracting images. Material and Methods: Twenty five simulated root canals in acrylic-resin blocks (with 20 degrees curvature) underwent cone beam computed tomography before and after preparation with the rotary systems (70 kVp, 4 mA, 10 s and with the 8x8 cm FoV selection). Canals were prepared up to F2 (ProTaper) and 24.04 (Wizard CD Plus) instruments and the working length was established to 15 mm. The tomographic images were imported into iCAT Vision software and CorelDraw for standardization. The superposition of pre- and post-instrumentation images from both systems was performed using Regeemy and Adobe Photoshop. The apical transportation was measured in millimetres using Image J. Five acrylic resin blocks were used to validate the superposition achieved by the software. Student's t-test for independent samples was used to evaluate the apical transportation achieved by the rotary systems using each software individually. Student's t-test for paired samples was used to compare the ability of each software in superposing and subtracting images from one rotary system per time. Results: The values obtained with Regeemy and Adobe Photoshop were similar to rotary systems (P>0.05). ProTaper Universal and Wizard CD Plus promoted similar apical transportation regardless of the software used for image's superposition and subtraction (P>0.05). Conclusion: Wizard CD Plus and ProTaper Universal promoted little apical transportation. Regeemy consists in a feasible software to superpose and subtract images and appears to be an alternative to Adobe Photoshop.
Resumo:
Eighty root canals of the premolars of 4 dogs, with vital pulp, were instrumented and filled during the same session with the Sealapex, CRCS, Sealer 26, and Apexit sealers, the animals were sacrificed 180 days after root canal filling and their maxillae and mandibles were removed and fixed in 10% formalin, After routine histologic processing, the sections were stained with hematoxylin-eosin and Mallory trichrome, Histopathologic analysis showed that Sealapex was the sealer that best permitted the deposition of mineralized tissue at the apical level and was the only sealer that provided complete sealing (37.5% of cases), With the use of Sealapex, no inflammatory infiltrate occurred and there was no reabsorption of mineralized tissues, In contrast, partial sealing and a moderate inflammatory infiltrate occurred with the use of CRCS, When Apexit and Sealer 26 were used the absence of sealing was frequent and active reabsorption of mineralized tissues occurred in most cases, the inflammatory infiltrate predominating with the use of Apexit was of the severe type, whereas with the use of Sealer 26 the inflammatory infiltrate was mild or absent.
Resumo:
The aim of this study was to assess, in vivo, the accuracy of the NovApex (R) electronic foramen locator in determining working length (WL) in vital and necrotic posterior teeth. The NovApex (R) was used in 144 canals: 35 teeth with vital pulps (68 canals) and 42 teeth with necrotic pulps (76 canals). WL was measured with the NovApex (R) locator and confirmed using the radiographic method. Differences between electronic and radiographic measurements ranging between 0.0 and 0.4 millimeters were classified as acceptable; differences equal to or greater than 0.5 millimeter were considered unacceptable. Pearson's chi-square test was used to assess the influence of pulp condition on the accuracy of NovApex (R) (alpha = 0.05). Regardless of pulp condition, differences between electronic and radiographic WL measurements were acceptable in 73.61% of the canals. No statistically significant differences in accuracy were observed when comparing vital and necrotic canals (p > 0.05). There were 38 unacceptable measurements. In none of these cases was the file tip located beyond the radiographic apex; in 32, it was located short of the NovApex (R) measurement. Pulp condition had no significant effect on the accuracy of NovApex (R).
Resumo:
Introduction: This study aimed to evaluate the close proximity established between the maxillary sinus floor and posterior teeth roots apices by using cone-beam computed tomographic scanning. Methods: The relationship of maxillary sinuses and posterior teeth roots, which were divided into 2 groups, was analyzed using i-CAT Vision software (Imaging Sciences, Hatfield, PA). Group 1 included all root apices found in close contact with the maxillary sinus floor without sinus floor elevation, whereas group 2 included all root apices that were protruded within the sinus producing an elevation of the bony cortical. Results: A total of 100 maxillary sinuses and 601 roots apices were evaluated. Group 1 presented 130 of 601 (21.6%) roots and group 2 presented 86 of 601 (14.3%) roots. Conclusions: The second molar mesiobuccal root apex is frequently found in close proximity with the sinus floor, and the relation between these anatomic structures should be considered in order to prevent an iatrogenic procedure and minimize the risks from an infectious disease within the sinus
Resumo:
Mode of access: Internet.
Resumo:
Besides the risk of filling material extrusion throughout the apex, a satisfactory apical seal can be difficult to achieve in canals with open apices or iatrogenic enlargements of the apical constriction. These situations pose a challenge to root canal filling. This paper describes the root canal filling of a maxillary right canine with an overinstrumented apex, complete loss of the apical stop, extensive canal transportation and apical periodontitis. A 5 mm calcium hydroxide apical plug was placed before root canal filling. The plug was made by soaking paper points with saline, dipping the points in calcium hydroxide powder and then applying it to the apex several times, until a consistent apical plug was obtained. The canal was then irrigated with saline in order to remove any residual calcium hydroxide from the root canal walls, dried with paper points and obturated with an inverted #80 gutta-percha cone and zinc oxide-eugenol based sealer by the lateral condensation technique. An 8-year radiographic follow-up showed formation of mineralized tissue sealing the apical foramen, apical remodeling and no signs of apical periodontitis.
Resumo:
The microstructure of parrotfish pharyngeal teeth was examined using scanning electron microscopy to infer possible mechanical properties of the dentition with respect to their function. Parrotfish tooth enameloid is formed from fluorapatite crystals grouped into bundles. In the upper and lower pharyngeal jaw, the majority of the crystal bundles are orientated either perpendicularly or vertically to the enameloid surface. The only exception is in the trailing apical enameloid in which the majority of bundles are orientated perpendicularly or horizontally to the trailing surface. A distinct transition occurs through the middle of the apex between the leading and trailing enameloid in teeth of the lower pharyngeal jaw. This transition appears less distinct in the teeth of the upper pharyngeal jaw. Enameloid microstructure indicates that shear forces predominate at the apex of the teeth. In the remainder of the enameloid, the microstructure indicates that wear is predominant, and the shear forces are of less importance.
Resumo:
Introduction. The dimensions of the thoracic intervertebral foramen in adolescent idiopathic scoliosis (AIS) have not previously been quantified. During posterior approach scoliosis correction surgery pedicle screws may occasionally breach into the foramen. Better understanding of the dimensions of the foramen may be useful in surgical planning. This study describes a reproducible method for measurement of the thoracic foramen in AIS using computerized tomography (CT). Methods. In 23 pre-operative female patients with Lenke 1 type AIS with right side convexity major curves confined to the thoracic spine the foraminal height (FH), foraminal width (FW), pedicle to superior articular process distance (P-SAP) and cross sectional foraminal area (FA) were measured using multiplanar reconstructed CT. Measurements were made at entrance, midpoint and exit of the thoracic foramina from T1/T2 to T11/T12. Results were correlated with potential dependent variables of major curve Cobb Angle measured on X-ray and CT, Age, Weight, Lenke classification subtype, Risser Grade and number of spinal levels in the major curve. Results. The FH, FW, P-SAP and FA dimensions and ratios are all significantly larger on the convexity of the major curve and maximal at or close to the apex. Mean thoracic foraminal dimensions change in a predictable manner relative to position on the major thoracic curve. There was no significant correlation with the measured foraminal dimensions or ratios and the potential dependent variables. The average ratio of convexity to concavity dimensions at the apex foramina for entrance, midpoint and exit respectively are FH (1.50, 1.38, 1.25), FW (1.28, 1.30, 0.98), FA (2.06, 1.84, 1.32), P-SAP (1.61, 1.47, 1.30). Conclusion. Foraminal dimensions of the thoracic spine are significantly affected by AIS. Foraminal dimensions have a predictable convexity to concavity ratio relative to the proximity to the major curve apex. Surgeons should be aware of these anatomical differences during scoliosis correction surgery.
Resumo:
INTRODUCTION The dimensions of the thoracic intervertebral foramen in adolescent idiopathic scoliosis (AIS) have not previously been quantified. During posterior approach scoliosis correction surgery pedicle screws may occasionally breach into the foramen. Better understanding of the dimensions of the foramen may be useful in surgical planning. This study describes a reproducible method for measurement of the thoracic foramen in AIS using computerized tomography (CT). METHODS In 23 pre-operative female patients with Lenke 1 type AIS with right side convexity major curves confined to the thoracic spine the foraminal height (FH), foraminal width (FW), pedicle to superior articular process distance (P-SAP) and cross sectional foraminal area (FA) were measured using multiplanar reconstructed CT. Measurements were made at entrance, midpoint and exit of the thoracic foramina from T1/T2 to T11/T12. Results were correlated with potential dependent variables of major curve Cobb Angle measured on X-ray and CT, Age, Weight, Lenke classification subtype, Risser Grade and number of spinal levels in the major curve. RESULTS The FH, FW, P-SAP and FA dimensions and ratios are all significantly larger on the convexity of the major curve and maximal at or close to the apex. Mean thoracic foraminal dimensions change in a predictable manner relative to position on the major thoracic curve. There was no significant correlation with the measured foraminal dimensions or ratios and the potential dependent variables. The average ratio of convexity to concavity dimensions at the apex foramina for entrance, midpoint and exit respectively are FH (1.50, 1.38, 1.25), FW (1.28, 1.30, 0.98), FA (2.06, 1.84, 1.32), P-SAP (1.61, 1.47, 1.30). CONCLUSION Foraminal dimensions of the thoracic spine are significantly affected by AIS. Foraminal dimensions have a predictable convexity to concavity ratio relative to the proximity to the major curve apex. Surgeons should be aware of these anatomical differences during scoliosis correction surgery.
Resumo:
Many plantation eucalypts are difficult to propagate from cuttings, and their rooted cuttings often possess very few adventitious roots. We microscopically examined the stem anatomy of cuttings from 12 species of eucalypts and we determined whether adventitious root formation in auxin-treated cuttings of four species was limited to particular positions around the vascular tissue. Most species contained a central pith that was arranged in a four-pointed stellate pattern. The surrounding vascular tissue was also arranged in a stellate pattern near the shoot apex but it developed a more rectangular shape at the outer phloem as the stems enlarged radially. Adventitious roots formed at, or slightly peripheral to, the vascular cambium, and they formed at both the corners and the sides of the rectangular-shaped vascular tissue. The study highlighted that auxin-treated eucalypt cuttings can produce roots at multiple positions around the vascular tissue and so propagation methods can aim to produce more than four adventitious roots per rooted cutting. Higher numbers of adventitious roots could improve the root system symmetry, stability, survival and growth rate of clonal eucalypt trees. © 2015 by the authors; licensee MDPI, Basel, Switzerland.
Resumo:
O objetivo deste estudo foi avaliar a dissolução do tecido pulpar pelo NaOCl contendo em sua composição agentes redutores da tensão superfical (Chlor-Xtra) quando comparados ao NaOCl convencional. Com esta finalidade 44 dentes unirradiculares humanos com tecido pulpar preservado em solução de formol a 10% foram agrupados em 22 pares de acordo com a semelhança de sua anatomia interna previamente avaliada por radiografias. Os canais foram instrumentados com sistema Protaper Universal e todo o processo de irrigação teve, além do tempo, seu volume e fluxo controlado por meio automatizado por meio do sistema Vatea Endodontic Iirrigation Device. Após cada canal que compunha um par ter sido instrumentado empregando-se uma das diferentes soluções testadas, as quais foram previamente avaliadas quanto a sua tensão superficial, ambos foram devidamente preparados e enviados para processamento e análise histológica. Cortes a 0,5, 1,2,3 e 4mm do ápice foram realizados, corados e fotografados. As imagens foram analisadas por meio do programa AxioVision a fim de estabelecer o percentual de tecido remanescente em relação à área total do canal nos segmentos estudados. As análises referentes a tensão superficial revelaram que o Chlor-Xtra demonstrou possuir significativamente menor tensão superficial quando comparado ao NaOCL convencional (p>0,05). A análise estatÃstica por meio do test T student das áreas dos canais, demonstrou que o pareamento das amostras foi eficiente entre os grupo NaOCl e Chlor-Xtra (p>0,05). Em relação ao Percentual de Tecido Remanescente (PTR), os resultados revelaram por meio de análise feita pelo teste Kruskal-Wallis e o teste de correlação de Spearman que o nÃvel de corte influencia significantemente o PTR (P<0,05).Por fim, o teste de Mann-Whitney indicou que o PTR não é influenciado pela solução irrigadora utilizada (P>0,05). A partir da análise dos resultados foi possÃvel concluir que quanto mais apicalmente foi o nÃvel de corte histológico dos canais estudados, maior foi o percentual de tecido pulpar remanescente independentemente da solução utilizada, portanto.não houve diferença significativa na qualidade do debridamento produzido pelas duas soluções testadas, desta forma indicando que a presença de agentes modificadores da tensão adicionados ao NaOCl não foi capaz de superar os resultados obtidos por soluções de NaOCl convencionais.