918 resultados para Tip Radiofrequency
Resumo:
Guinea pigs were exposed to pure tones of 10 kHz at intensities between 98 and 115 dB SPL for 5-30 min, to produce varying degrees of acoustic trauma. Changes in auditory thresholds were measured electrophysiologically, and the animals were immediately fixed for scanning electron microscopy. Correlation between morphological changes to the hair bundle and losses in threshold, showed that with the smallest degrees of trauma (98 dB SPL for 15 min, mean maximum threshold loss of 22 dB), damage was confined to a small stretch of inner hair cells (IHC), with only subtle changes to the stereocilia of the outer hair cells (OHC). At exposure intensities greater than 102 dB SPL (duration: 15 min) the IHC stereocilia in the centre of the lesion were always substantially disarrayed. Substantial damage to the OHC bundles was seen only with exposures above 110 dB SPL(duration: greater than or equal to 5 min), producing threshold losses of 50 dB or more. Tip links were lost only where the stereocilia were disarrayed. It is concluded that the tip links are not the most vulnerable components of the cochlear hair cell, but that relatively low levels of acoustic stimulation can cause significant damage to the stereociliary bundle of the IHCs.
Resumo:
Background-Epicardial coronary injury is by far the most feared complication of epicardial ablation. Little information is available regarding the chronic effects of delivering radiofrequency in the vicinity of large coronary vessels, and the long-term impact of this approach for mapping and ablation on epicardial vessel integrity is poorly understood. Therefore, the aim of this study was to characterize the acute and chronic histopathologic changes produced by in vivo epicardial pulses of radiofrequency ablation on coronary artery of porcine hearts. Methods and Results-Seven pigs underwent a left thoracotomy. The catheter was sutured adjacent to the left anterior descending artery and left circumflex artery, and 20 pulses of radiofrequency energy were applied. Radiofrequency lesions located no more than 1 mm of the vessel were used for this analysis. Three animals were euthanized 20 days (acute phase) after the procedure and 4 animals after 70 days (chronic phase). The following parameters were obtained in each vessel analyzed: (1) internal and external perimeter; (2) vessel wall thickness; (3) tunica media thickness, and (4) tunica intima thickness. The presence of adipose tissue around the coronary arteries, the distance between the artery and the epicardium, and the anatomic relationship of the artery with the coronary vein was also documented for each section. Sixteen of 20 (80%) sections analyzed, showed intimal thickening with a mean of 0.18 +/- 0.14 mm compared with 0.13 +/- 0.16 mm in the acute phase (P=0.331). The mean tunica media thickness was 0.25 +/- 0.10 mm in the chronic phase animals compared with 0.18 +/- 0.03 mm in the acute phase animals (P=0.021). A clear protective effect of pericardial fat and coronary veins was also present. A positive correlation between depth of radiofrequency lesion and the degree of vessel injury expressed as intimal and media thickening (P=0.001) was present. A negative correlation was identified (r = -0.83; P=0.002) between intimal thickening and distance between epicardium and coronary artery. Conclusions-In this porcine model of in vivo epicardial radiofrequency ablation in proximity to coronary arteries leads to acute and chronic histopathologic changes characterized by tunica intima and media thickening, with replacement of smooth muscle cells with extracellular matrix, but no significant stenosis was observed up to 70 days after the ablation. The absence of acute coronary occlusion or injury does not preclude subsequent significant arterial damage, which frequently occurs when epicardial radiofrequency applications are delivered in close vicinity to the vessels. (Circ Arrhythm Electrophysiol. 2011;4:526-531.)
Resumo:
The authors present the first clinical implementation of an endoscopic-assisted percutaneous anterolateral radiofrequency cordotomy. The aim of this article is to demonstrate the intradural endoscopic visualization of the cervical spinal cord via a percutaneous approach to refine the spinal target for anterolateral cordotomy, avoiding undesired trauma to the spinal tissue or injury to blood vessels. Initially, a lateral puncture of the spinal canal in the C1-2 interspace is performed, guided by fluoroscopy. As soon as CSF is reached by the guide cannula (17-gauge needle), the endoscope can be inserted for visualization of the spinal cord and its surrounding structures. The endoscopic visualization provided clear identification of the pial surface of the spinal cord, arachnoid membrane, dentate ligament, dorsal and ventral root entry zone, and blood vessels. The target for electrode insertion into the spinal cord was determined to be the midpoint from the dentate ligament and the ventral root entry zone. The endoscopic guidance shortened the fluoroscopy usage time and no intrathecal contrast administration was needed. Cordotomy was performed by a standard radiofrequency method after refining of the neurophysiological target. Satisfactory analgesia was provided by the procedure with no additional complications or CSF leak. The initial use of this technique suggests that a percutaneous endoscopic procedure may be useful for particular manipulation of the spinal cord, possibly adding a degree of safety to the procedure and improving its effectiveness. (DOI: 10.3171/2010.4.JNS091779)
Resumo:
OBJECTIVE: A giant fusiform aneurysm in the posterior cerebral artery (PCA) is rare, as is fenestration of the PCA and basilar apex variation. We describe the angiographic and surgical findings of a giant fusiform aneurysm in the P1-P2 PCA segment associated with PCA bilateral fenestration and superior cerebellar artery double origin. CLINICAL PRESENTATION: A 26-year-old woman presented with a 2-month history of visual blurring. Digital subtraction angiography showed a giant (2.5 cm) fusiform PCA aneurysm in the right P1-P2 segment. The 3-dimensional view showed a caudal fusion pattern from the upper portion of the basilar artery associated with a bilateral long fenestration of the P1 and P2 segments and superior cerebellar artery double origin. INTERVENTION: Surgical trapping of the right P1 -P2 segment, including the posterior communicating artery, was performed by a pretemporal approach. Angiograms performed 3 and 13 months after surgery showed complete aneurysm exclusion, and the PCA was permeated and filled the PCA territory. Clinical follow-up at 14 months showed the patient with no deficits and a return to normal life. CONCLUSION: To our knowledge, this is the first report of a giant fusiform aneurysm of the PCA associated with P1-P2 segment fenestration and other variations of the basilar apex (bilateral superior cerebellar artery duplication and caudal fusion). Comprehension of the embryology and anatomy of the PCA and its related vessels and branches is fundamental to the decision-making process for a PCA aneurysm, especially when parent vessel occlusion is planned.
Resumo:
This study compared ultrasonic chemical vapor deposition (CVD)-coated tip (CVDentus #8.1117-1; Clorovale Diamantes Ind. e Com. Ltda Epp, Sao Jose dos Campos, SP, Brazil) versus high-speed (#FG700L) and low-speed (#699) carbide burs for apicoectomy, evaluating the time required for resection and analyzing the root-end surfaces by scanning electron microscopy. Thirty extracted human premolars had the canals instrumented and obturated and were randomly assigned to 3 groups (n = 10), according to the instrument used for root-end resection. The time required for resection of the apical 2 mm of each root was recorded. The resected apical segments were dried, sputter coated with gold, and examined with a scanning electron microscope at X 350 magnification. A four-point (0-3) scoring system was used to evaluate the apical surface smoothness. The results were analyzed statistically by the Kruskal-Wallis test and two-by-two comparisons analyses were performed using the Miller test. The significance level was set at 5%. Root-end resection with the high-speed bur was significantly faster (p < 0.05) compared with the low-speed bur and CVD tip. The carbide burs produced significantly smoother root-end surfaces than the CVD tip (p < 0.05). The low-speed bur produced the smoothest root-end surfaces, whereas the roughest and most irregular root ends (p < 0.05) were obtained with the CVD tip. However, no statistically significant difference (p > 0.05) was found between the high- and low-speed burs regarding the surface roughness of the resected root ends (p > 0.05). In conclusion, under the tested conditions, ultrasonic root-end resection took a longer time and resulted in rougher surfaces compared with the use of carbide burs at both high and low speed. (J Endod 2009;35:265-268)
Resumo:
This study evaluates the effect on post space debridement in oval-shaped canals of an experimental ultrasonic tip with oval section (Satelec) compared with a circular ultrasonic tip (KaVo). Thirty teeth with an oval-shaped canal were endodontically treated and obturated and then randomly divided into 3 groups (n = 10) according to the procedure used for post space debridement: Satelec tip, Largo #2 drill + KaVo file, and Largo #2 drill + water. Debris and dentin tubules were evaluated by assigning scores to scanning electron microscope post spaces images; lower scores corresponded to fewer debris and higher number of open tubules. The Satelec group showed significantly lower debris and open tubules scores than KaVo group (p < .05) and control group (p < .05), which differed significantly between each other (p < .05). Also the debris and open tubules scores in different post space regions differed significantly among the experimental groups (p < .001). The oval ultrasonic tip resulted in a better post space debridement than a circular ultrasonic tip in oval-shaped canals.
Resumo:
Many solid tumors have a poor response to systemic chemotherapy, local radiotherapy or surgical recession. They are responsible for premature morbidity and decreased patient survival. The radiofrequency ablation is an emerging technique, and is now becoming more widespread throughout the world because it is minimally invasive, image guided, which offers the possibility of an effective and less costly approach. The procedure can be performed percutaneously, guided by several imaging modalities as Ultrasound, Computed Tomography and Magnetic Resonance. This article pretends to demonstrate the state-of-the-art of this technique focusing in the technical aspects and application of radiofrequency ablation.
Resumo:
Companies and researchers involved in developing miniaturized electronic devices face the basic problem of the needed batteries size, finite life of time and environmental pollution caused by their final deposition. The current trends to overcome this situation point towards Energy Harvesting technology. These harvesters (or scavengers) store the energy from sources present in the ambient (as wind, solar, electromagnetic, etc) and are costless for us. Piezoelectric devices are the ones that show a higher power density, and materials as ceramic PZT or polymeric PVDF have already demonstrated their ability to act as such energy harvester elements. Combinations between piezoelectric and electromagnetic mechanism have been also extensively investigated. Nevertheless, the power generated by these combinations is limited under the application of small magnetic fields, reducing the performance of the energy harvester [1]. In the last years the appearance of magnetoelectric (ME) devices, in which the piezoelectric deformation is driven by the magnetostrictive element, enables to extract the energy of very small electromagnetic signals through the generated magnetoelectric voltage at the piezoelectric element. However, very little work has been done testing PVDF polymer as piezoelectric constituent of the ME energy harvester device, and only to be proposed as a possibility of application [2]. Among the advantages of using piezopolymers for vibrational energy harvesting we can remember that they are ductile, resilient to shock, deformable and lightweight. In this work we demonstrate the feasibility of using magnetostrictive Fe-rich magnetic amorphous alloys/piezoelectric PVDF sandwich-type laminated ME devices as energy harvesters. A very simple experimental set-up will show how these laminates can extract energy, in amounts of μW, from an external AC field.
Resumo:
Dissertação de mestrado integrado em Engenharia Biomédica (área de especialização em Eletrónica Médica)
Resumo:
OBJECTIVE: To demonstrate the feasibility and safety of simultaneous catheterization and mapping of the 4 pulmonary veins for ablation of atrial fibrillation. METHODS: Ten patients, 8 with paroxysmal atrial fibrillation and 2 with persistent atrial fibrillation, refractory to at least 2 antiarrhythmic drugs and without structural cardiopathy, were consecutively studied. Through the transseptal insertion of 2 long sheaths, 4 pulmonary veins were simultaneously catheterized with octapolar microcatheters. After identification of arrhythmogenic foci radiofrequency was applied under angiographic or ultrasonographic control. RESULTS: During 17 procedures, 40 pulmonary veins were mapped, 16 of which had local ectopic activity, related or not with the triggering of atrial fibrillation paroxysms. At the end of each procedure, suppression of arrhythmias was obtained in 8 patients, and elimination of pulmonary vein potentials was accomplished in 4. During the clinical follow-up of 9.6±3 months, 7 patients remained in sinus rhythm, 5 of whom were using antiarrhythmic drugs that had previously been ineffective. None of the patients had pulmonary hypertension or evidence of stenosis in the pulmonary veins. CONCLUSION: Selective and simultaneous catheterization of the 4 pulmonary veins with microcatheters for simultaneous recording of their electrical activity is a feasible and safe procedure that may help ablation of atrial fibrillation.
Resumo:
Background:Radiofrequency ablation is the standard non-pharmacological treatment for arrhythmias in pediatric patients. However, arrhythmias and their associated causes have particular features in this population.Objective:To analyze the epidemiological characteristics and findings of electrophysiological diagnostic studies and radiofrequency ablations in pediatric patients referred to the Electrophysiology Unit at Instituto de Cardiologia do Rio Grande do Sul, in order to characterize the particularities of this population.Methods:Cross-sectional study with 330 electrophysiological procedures performed in patients aged less than 20 years between June 1997 and August 2013.Results:In total, 330 procedures (9.6% of the overall procedures) were performed in patients aged less than 20 years (14.33 ± 3.25 years, age range 3 months to 19 years), 201 of which were males (60.9%). A total of 108 (32.7%) electrophysiological diagnostic studies were performed and of these, 48.1% showed abnormal findings. Overall, 219 radiofrequency ablations were performed (66.3%) with a success rate of 84.8%. The presence of an accessory pathway was the most prevalent finding, occurring in 158 cases (72.1%), followed by atrioventricular nodal reentrant tachycardia (16.8%), typical atrial flutter (3.1%) and extrasystoles originating from the right ventricular outflow tract (2.7%). Three patients developed complications during ablation (1.4%). Among congenital heart diseases, which occurred in 51 (15.4%) patients, atrial sept defect was the most frequent (27.4%), followed by ventricular sept defect (25.4%) and Ebstein's anomaly (17.6%).Conclusion:Electrophysiological study and radiofrequency ablation are effective tools for diagnosis and treatment of arrhythmias in the pediatric population.
Resumo:
Coupled Electromechanical Analysis, MEMS Modeling, MEMS, RF MEMS Switches, Defected Ground Structures, Reconfigurable Resonator
Resumo:
A 46-year-old man underwent radiofrequency (RF) ablation of three liver metastases 7 months after undergoing right colectomy for a pT2N0Mx colon adenocarcinoma. Three months after the procedure, he developed hepatic abscesses related to a fistula between the distal ileum and segment V biliary branches.