986 resultados para Thickness measurement


Relevância:

60.00% 60.00%

Publicador:

Resumo:

In the fields of organic electronics and biotechnology, applications for organic polymer thin films fabricated using low-temperature non-equilibrium plasma techniques are gaining significant attention because of the physical and chemical stability of thin films and the low cost of production. Polymer thin films were fabricated from non-synthetic terpinen-4-ol using radiofrequency polymerization (13.56 MHz) on low loss dielectric substrates and their permittivity properties were ascertained to determine potential applications for these organic films. Real and imaginary parts of permittivity as a function of frequency were measured using the variable angle spectroscopic ellipsometer. The real part of permittivity (k) was found to be between 2.34 and 2.65 in the wavelength region of 400–1100 nm, indicating a potential low-k material. These permittivity values were confirmed at microwave frequencies. Dielectric properties of polyterpenol films were measured by means of split post dielectric resonators (SPDRs) operating at frequencies of 10 GHz and 20 GHz. Permittivity increased for samples deposited at higher RF energy – from 2.65 (25 W) to 2.83 (75 W) measured by a 20-GHz SPDR and from 2.32 (25 W) to 2.53 (100 W) obtained using a 10-GHz SPDR. The error in permittivity measurement was predominantly attributed to the uncertainty in film thickness measurement.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We present a good alternative method to improve the tribological properties of polymer films by chemisorbing a long-chain monolayer on the functional polymer surface. Thus, a novel self-assembled monolayer is successfully prepared on a silicon substrate coated with amino-group-containing polyethyleneimine (PEI) by the chemical adsorption of stearic acid (STA) molecules. The formation and structure of the STA-PEI film are characterized by means of contact-angle measurement and ellipsometric thickness measurement, and of Fourier transformation infrared spectrometric and atomic force microscopic analyses. The micro- and macro-tribological properties of the STA-PEI film are investigated on an atomic force microscope (AFM) and a unidirectional tribometer, respectively. It has been found that the STA monolayer about 2.1-nm thick is produced on the PEI coating by the chemical reaction between the amino groups in the PEI and the carboxyl group in the STA molecules to form a covalent amide bond in the presence of N,N'-dicyclohexylcarbodiimide (DCCD) as a dehydrating regent. By introducing the STA monolayer, the hydrophilic PEI polymer surface becomes hydrophobic with a water contact angle to be about 105degrees. Study of the time dependence of the film formation shows that the adsorption of PEI is fast, whereas at least 24 h is needed to generate the saturated STA monolayer. Whereas the PEI coating has relatively high adhesion, friction, and poor anti-wear ability, the STA-PEI film possesses good adhesive resistance and high load-carrying capacity and anti-wear ability, which could be attributed to the chemical structure of the STA-PEI thin film. It is assumed that the hydrogen bonds between the molecules of the STA-PEI film act to stabilize the film and can be restored after breaking during sliding. Thus, the self-assembled STA-PEI thin film might find promising application in the lubrication of micro-electromechanical systems (MEMS).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A novel self-assembled dual-layer film as apotential excellent lubricant for micromachines was successfully prepared on single-crystal silicon substrate by chemical adsorption of stearic acid (STA) molecules on self-assembled monolayer of 3-aminopropyltri

Relevância:

60.00% 60.00%

Publicador:

Resumo:

根据石英晶体双折射率的色散特性,对石英波片的偏光干涉谱进行了理论分析和数值模拟,提出了一种石英波片延迟量和厚度的偏光干涉标定法。即由偏光干涉谱,可以得出石英波片在200~2000 nm宽光谱范围内的延迟量;通过对长波段的偏光干涉谱极值波长的精确判断,可以准确地计算出该石英波片的厚度。利用Lambda 900 紫外可见近红外分光光度计对一片石英波片的偏光干涉谱进行了测量。在波长精度为0.1 nm的情况下,测量的厚度精度为0.1 μm。误差分析结果表明,通过提高光谱的最小分辨力及选择较长的光谱波段进行测量计算

Relevância:

60.00% 60.00%

Publicador:

Resumo:

针对自由曲面透明体厚度测量,提出一种基于结构光机理的3D 视觉测量方法和系统结构,介绍了该方法的基本原理和测量系统实现技术,并给出了部分实验,证实了该方法的有效性。

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The native oxide on the rolled aerospace aluminum alloy 7475-T7651 was characterized using a variety of different techniques, including X-ray Photoelectron Spectrometry (XPS), Auger Electron Spectrometry (AES), Transmission Electron Microscopy (TEM), Electron Energy Loss Spectrometry (EELS), Glow Discharge Optical Emission Spectrometry (GDOES), and Rutherford Backscattered Spectrometry (RBS). All techniques revealed that the native oxide layer is magnesium-rich and is probably a mixture of magnesium and aluminum–magnesium oxides.1 The oxide layer was found to be of nonuniform thickness due to the rolling process involved during the manufacture of this sheet alloy; this complicates analysis using techniques which have poor spatial resolution. Direct thickness measurement from cross-sectional TEM reveals an oxide thickness which varies between 125 and 500 nm. This large variation in thickness was also evident from GDOES and AES depth profiles as well asthe RBS data. Both XPS and RBS also show evidence for the presence of heavy metals in the oxide.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Hollow sphere cellular aluminium (HSCA) samples were fabricated by bonding together two kinds of single aluminium hollow spheres with the same outside diameter of 4 mm but different wall thicknesses of 0.1 mm and 0.3 mm, in which the hollow spheres with the thinner sphere wall thickness were used as artificial defects. Four types of HSCA samples with the same relative density but various distributions of artificial defects were prepared by simple cubic packing. For comparing, HSCA sample without defective hollow spheres inside was also prepared. The effects of the distribution of the artificial defects on the deformation behaviours and mechanical properties were investigated by compressive tests. Results indicated that the nominal stress - nominal strain curve and the deformation behavior of the HSCA samples varied with the distribution of the artificial defects in spite of the same relative density. It is therefore suggested that the deformation behavior and mechanical property of cellular materials were also significantly affected by the distribution of defects. In particular, the plateau stress of the HSCA samples increased with the decrease in number of contact points between the normal hollow spheres and the defective hollow spheres in the loading direction during deformation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The thickness of the retinal nerve fiber layer (RFNL) has become a diagnose measure for glaucoma assessment. To measure this thickness, accurate segmentation of the RFNL in optical coherence tomography (OCT) images is essential. Identification of a suitable segmentation algorithm will facilitate the enhancement of the RNFL thickness measurement accuracy. This paper investigates the performance of six algorithms in the segmentation of RNFL in OCT images. The algorithms are: normalised cuts, region growing, k-means clustering, active contour, level sets segmentation: Piecewise Gaussian Method (PGM) and Kernelized Method (KM). The performance of the six algorithms are determined through a set of experiments on OCT retinal images. An experimental procedure is used to measure the performance of the tested algorithms. The measured segmentation precision-recall results of the six algorithms are compared and discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Os objetivos neste trabalho foram estimar as correlações entre medidas obtidas por ultrassonografia e na carcaça e acompanhar o desenvolvimento da área de olho-de-lombo e a deposição de gordura de búfalos em diferentes períodos de confinamento. Foram utilizados 20 bubalinos da raça Murrah, castrados, abatidos aos 75, 100, 125 ou 150 dias de confinamento. As medidas realizadas foram área de olho-de-lombo, espessura de gordura subcutânea do dorso e espessura de gordura da garupa, mensuradas por ultrassonografia quando os búfalos atingiram o tempo de abate e na carcaça, após o abate. A espessura de gordura subcutânea da carcaça foi avaliada utilizando-se paquímetro e a área de olho-de-lombo da carcaça, régua do quadrante de pontos. O período de confinamento apresentou efeito linear crescente na área de olho-de-lombo e nas espessuras de gordura do dorso e da garupa avaliadas por ultrassom e na carcaça. O efeito linear positivo entre 75 e 150 dias de confinamento, tanto para a área de olho-de-lombo como para espessura de gordura medidas no dorso e na garupa, comprovou que os animais ainda não haviam atingido a maturidade. As correlações entre as medidas obtidas por ultrassom e na carcaça foram 0,82 para área de olho-de-lombo e 0,85 para espessura de gordura subcutânea no dorso. As características de carcaça medidas por ultrassom em bubalinos apresentam boas correlações com as medidas realizadas na carcaça no momento do abate, o que permite, em bubalinos da raça Murrah castrados e oriundos de rebanho leiteiro, acompanhar as alterações dessas características durante o desenvolvimento.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A polymeric precursor solution was employed in preparing SrBi2Nb2O9 (SBN) powder and thin films dip coated onto Si(100) substrate. XRD results show that the SBN perovskite phase forms at temperatures as low as 600°C through an intermediate fluorite phase. This fluorite phase is observed for samples heat-treated at temperatures of 400 and 500°C. After heat treatment at temperatures ranging from 300 to 800°C, thin films were shown to be crack free. Grazing incident angle XRD characterization shows the occurrence of the fluorite intermediate phase for films also. The thickness of films, measured by MEV, was in the order of 80-100 nm.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

It is well known that fatigue behaviour is an important parameter to be considered in mechanical components subjected to constant and variable amplitude loadings. In combination with corrosion phenomenon, fatigue effects were responsible for proximally 64% of fails that occur in metallic parts of aeronautical accidents in the last 30 years. Recovered substrates have been extensively used in the aerospace field. Cadmium electroplating has been widely applied to promote protective coatings in aeronautical components, resulting in excellent corrosion protection combined with a good performance in cyclic loading. Ecological considerations allied to the increasing demands for corrosion resistance, resulted in the search for possible alternatives. Zinc-nickel alloys received considerable interest recently, since these coatings showed some advantages such as a good resistance to white and red rust, high plating rates and acceptation in the market. In this study the effects of zinc-nickel coatings electroplated on AISI 4340 high strength steel were analysed on rotating bending and axial fatigue strength, corrosion and adhesion resistance. Compressive residual stress field was measured by a X-ray tensometry prior to fatigue tests. Optical microscopy images showed coating thicknesses, adhesion and the existence of an uniform coverage of nearly all substrates. The fractured fatigue specimens were investigated using a scanning electron microscope. Three different zinc-nickel coating thicknesses were tested and comparison with rotating bending fatigue data from specimens cadmium electroplated and heat treated at 190°C for 3, 8 and 24 hours to avoid the diffusion of hydrogen in the substrate, was performed. Experimental results showed effect of coatings on the AISI 4340 steel behaviour when submitted to fatigue testing and the existence of coating thickness influence on the fatigue strength.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives: The aim of this study was to evaluate the effect of thermal and mechanical cycling alone or in combination, on the flexural strength of ceramic and metallic frameworks cast in gold alloy or titanium. Methods: Metallic frameworks (25 mm × 3 mm × 0.5 mm) (N = 96) cast in gold alloy or commercial pure titanium (Ti cp) were obtained using acrylic templates. They were airborne particle-abraded with 150 μm aluminum oxide at the central area of the frameworks (8 mm × 3 mm). Bonding agent and opaque were applied on the particle-abraded surfaces and the corresponding ceramic for each metal was fired onto them. The thickness of the ceramic layer was standardized by positioning the frameworks in a metallic template (height: 1 mm). The specimens from each ceramic-metal combination (N = 96, n = 12 per group) were randomly assigned into four experimental fatigue conditions, namely water storage at 37 °C for 24 h (control group), thermal cycling (3000 cycles, between 4 and 55 °C, dwell time: 10 s), mechanical cycling (20,000 cycles under 10 N load, immersion in distilled water at 37 °C) and, thermal and mechanical cycling. A flexural strength test was performed in a universal testing machine (crosshead speed: 1.5 mm/min). Data were statistically analyzed using two-way ANOVA and Tukey's test (α = 0.05). Results: The mean flexural strength values for the ceramic-gold alloy combination (55 ± 7.2 MPa) were significantly higher than those of the ceramic-Ti cp combination (32 ± 6.7 MPa) regardless of the fatigue conditions performed (p < 0.05). Mechanical and thermo-mechanical fatigue decreased the flexural strength results significantly for both ceramic-gold alloy (52 ± 6.6 and 53 ± 5.6 MPa, respectively) and ceramic-Ti cp combinations (29 ± 6.8 and 29 ± 6.8 MPa, respectively) compared to the control group (58 ± 7.8 and 39 ± 5.1 MPa, for gold and Ti cp, respectively) (p < 0.05) (Tukey's test). While ceramic-Ti cp combinations failed adhesively at the metal-opaque interface, gold alloy frameworks exhibited a residue of ceramic material on the surface in all experimental groups. Significance: Mechanical and thermo-mechanical fatigue conditions decreased the flexural strength values for both ceramic-gold alloy and ceramic-Ti cp combinations with the results being significantly lower for the latter in all experimental conditions. © 2007 Academy of Dental Materials.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)