239 resultados para Tensioned Tether


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Observations of a tethered meteorological balloon show that a strong vibration coupling exists between axial forcing of the tether and ovalling deformations of the balloon. Such coupling may lead to system instabilities and fatigue failure in a tethered-balloon system. This is particularly relevant in the case of a balloon launched from a moving vessel, as is proposed as part of the SPICE geoengineering project. This paper investigates the vibration characteristics of a tethered, spherical balloon using a simple analytical model: a tensioned, spherical membrane attached to a spring. The analytical solution for the natural frequencies and modeshapes of this system is compared to transfer functions obtained by laser vibrometry. These results are then used to determine the most suitable method of modelling the dynamic response of a tethered balloon.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A high-altitude tethered balloon (HATB) reaching a height of 20 km has numerous applications including communications, meteorological monitoring, surveillance and, for the current paper, geoengineering. The HATB configuration consists of a 20 km tether rising up from the ground through the troposphere, where the wind-regime can be turbulent and include high-wind velocities due to the jet-stream, up into the more stable stratosphere where the tether would be attached to a spherical balloon. This paper evaluates wind-excited vibration of a HATB and will investigate the advantages of using a streamlined instead of a circular tether profile. Streamlining the tether reduces drag but introduces stability problems and complicates the numerical modelling. Consequently, prior to a thorough investigation of the stability issues due to fluid-structure interaction, a 3D nonlinear lumped-mass HATB model is used to quantify the benefit of a streamlined tether. The benefit is quantified by comparing the system specifications - such as balloon size and the tension in the tether - required to meet certain design requirements driven by the Stratospheric Particle Injection for Climate Engineering (SPICE) project. The SPICE project is investigating the feasibility of climate engineering using a HATB.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Improvements in the structural performance of glulam timber beams by the inclusion of reinforcing materials can increase both the service performance and ultimate capacity. In recent years research focusing on the addition of fibre reinforced polymers (FRP) to strengthen members has yielded positive results. However, the FRP material is still relatively expensive and its full potential in combination with structural timber has not been realised. This paper describes a series of four-point bending tests that were conducted, under service loads and to failure, on unreinforced, reinforced and post-tensioned glulam timber beams, where the reinforcing tendon used was 12mm diameter basalt fibre reinforced polymer (BFRP). The research was designed to evaluate the benefits offered by including an active reinforcement in contrast to the passive reinforcement typically used within timber strengthening works, in addition to establishing the affect that bonding the reinforcing tendon has on the material’s performance. Further experimental tests have been developed to investigate the long-term implications of this research, with emphasis placed upon creep and loss of post-tensioning.
The laboratory investigations established that the flexural strength and stiffness increased for both the unbonded and bonded post-tensioned timbers compared to the unreinforced beams. Timber that was post-tensioned with an unbonded BFRP tendon showed a flexural strength increase of 2.8% and an increase in stiffness of 8.7%. Post-tensioned beams with a bonded BFRP tendon showed increases in flexural strength and stiffness of 16.6% and 11.5% respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article examines the effectiveness of two innovative retrofitting solutions at enhancing the seismic behaviour of a substandard reinforced concrete building tested on a shake table as part of the Pan-European funded project BANDIT. To simulate typical substandard construction, the reinforcement of columns and beam-column joints of the full-scale structure had inadequate detailing. An initial series of shake table tests were carried out to assess the seismic behaviour of the bare building and the effectiveness of a first retrofitting intervention using Post-Tensioned Metal Straps. After these tests, columns and joints were repaired and subsequently retrofitted using a retrofitting solution consisting of Carbon Fibre Reinforced Polymers and Post-Tensioned Metal Straps applied on opposite frames of the building. The building was then subjected to unidirectional and three-dimensional incremental seismic excitations to assess the effectiveness of the two retrofitting solutions at improving the global and local building performance. The article provides details of the above shake table testing programme and retrofitting solutions, and discusses the test results in terms of the observed damage, global damage indexes, performance levels and local strains. It is shown that whilst the original bare building was significantly damaged at a peak ground acceleration (PGA) of 0.15g, the retrofitted building resisted severe threedimensional shake table tests up to PGA=0.60g without failure. Moreover, the retrofitting intervention enhanced the interstorey drift ratio capacity of the 1st and 2nd floors by 160% and 110%, respectively. Therefore, the proposed dual retrofitting system is proven to be very effective for improving the seismic performance of substandard buildings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effectiveness of a novel Post-Tensioned Metal Strapping (PTMS) technique at enhancing the seismic behaviour of a substandard RC building was investigated through full-scale shake-table tests during the EU-funded project BANDIT. The building had inadequate reinforcement detailing in columns and joints to replicate old construction practices. After the bare building was initially damaged significantly, it was repaired and strengthened with PTMS to perform additional seismic tests. The PTMS technique improved considerably the seismic performance of the tested building. Whilst the bare building experienced critical damage at an earthquake of PGA=0.15g, the PTMS-strengthened building sustained a PGA=0.35g earthquake without compromising stability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

At the end of its tether! The fusion of a six-membered ring onto the four-carbon-atom tether of substrate 1 provides an efficient approach toward the polycyclic ring systems of the natural products aphidicolin and stemodinone. The reaction represents a unique example of a preference for product formation from an endo exciplex in an intramolecular system (exo:endo 2:3=1.0:1.2).