914 resultados para Temporary calf removal


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background. An enlarged tracheoesophageal puncture (TEP) results in aspiration around the voice prosthesis (VP) and may lead to pneumonia. The aims of this research were: (1) to conduct a systematic review and meta-analysis on enlarged TEP; (2) to analyze preoperative, perioperative, and postoperative risk factors for enlarged TEP; and (3) to evaluate control of leakage around the VP using conservative treatments and adverse events in patients with enlarged TEP.^ Methods. A systematic review was conducted (1978-2008). A summary risk estimate was calculated using a random-effects meta-analysis model. A retrospective cohort study was completed. Patients who underwent total laryngectomy and TEP at The University of Texas M. D. Anderson Cancer Center (MDACC) were included. Multiple logistic regression methods were used to assess risk factors for enlargement. Descriptive and bivariate statistics were calculated to evaluate outcomes and adverse events. Results: Twenty-seven manuscripts were included in the systematic review. The summary risk estimate of enlarged TEP/leakage around the VP was 7.2% (95% CI: 4.8%-9.6%). Temporary VP removal and TEP-site injections were the most commonly reported treatments. Neither prosthetic diameter (p=0.076) nor timing of TEP (p=0.297) significantly increased risk of enlargement per stratified analyses of published outcomes. The cumulative incidence of enlarged TEP was 18.6% (36/194, 95% CI: 13.0%-24.1%) in the MDACC cohort. Enlarged TEP occurred exclusively in irradiated patients. Adjusting for length of follow-up and timing of TEP, advanced nodal disease (ORadjusted: 4.3, 95% CI: 1.0-19.1), stricture (ORadjusted : 3.2, 95% CI: 1.2-8.6), and locoregional recurrence/distant metastasis after laryngectomy (ORadjusted: 6.2, 95% CI: 2.3-16.4) increased risk of enlarged TEP. At last follow-up, conservative methods controlled leakage around the VP in 81% (29/36) of patients. Unresolved leakage was associated with recurrent cancer (p=0.081) and TEP-site irregularity (p=0.003). Relative to those without enlargement, enlarged TEP patients had significantly higher risk of pneumonia (RR: 3.4, 95% CI: 1.9-6.2).^ Conclusions. These data establish that enlarged TEP poses serious health risks, and provide insight into medical and oncologic factors that may contribute to development of this complication. In addition, this research supports the use of conservative treatments to address leakage after enlarged TEP in lieu of complete TEP closure.^

Relevância:

40.00% 40.00%

Publicador:

Resumo:

DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Contemporary cities no longer offer the same types of permanent environments that we planned for in the latter part of the twentieth century. Our public spaces are increasingly temporary, transient, and ephemeral. The theories, principles and tactics with which we designed these spaces in the past are no longer appropriate. We need a new theory for understanding the creation, use, and reuse of temporary public space. Moe than a theory, we need new architectural tactics or strategies that can be reliably employed to create successful temporary public spaces. This paper will present ongoing research that starts that process through critical review and technical analysis of existing and historic temporary public spaces. Through the analysis of a number of public spaces, that were either designed for temporary use or became temporary through changing social conditions, this research identifies the tactics and heuristics used in such projects. These tactics and heuristics are then analysed to extract some broader principles for the design of temporary public space. The theories of time related building layers, a model of environmental sustainability, and the recycling of social meaning, are all explored. The paper will go on to identify a number of key questions that need to be explored and addressed by a theory for such developments: How can we retain social meaning in the fabric of the city and its public spaces while we disassemble it and recycle it into new purposes? What role will preservation have in the rapidly changing future; will exemplary temporary spaces be preserved and thereby become no longer temporary? Does the environmental advantage of recycling materials, components and spaces outweigh the removal or social loss of temporary public space? This research starts to identify the knowledge gaps and proposes a number of strategies for making public space in the age of temporary, recyclable, and repurposing of our urban infrastructure; a way of creating lighter, cheaper, quicker, and temporary interventions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Invasive macrophyte species are a threat to native biodiversity and often grow to nuisance levels, therefore, making control options necessary. Macrophyte control can have pronounced impacts on littoral fish by reducing habitat heterogeneity and the loss of profitable (high density of invertebrates) foraging areas. Yet, there is little known about the impacts of macrophyte removal on invertebrates themselves. We conducted a macrophyte removal experiment, that is the cutting of channels into dense macrophyte beds, to investigate the impact of mechanical macrophyte control on invertebrate and fish communities in a littoral zone dominated by the invasive macrophyte Lagarosiphon major. The effect of macrophyte removal had only a temporary effect on macrophyte areal cover (4 months). Nevertheless, the treatment increased light penetration significantly. However, we could not detect any difference in epiphyton biomass. Invertebrate biomass increased in macrophyte stands 4 months after treatment and there was a shift in the invertebrate community composition. Mechanical control had no effect on invertebrate biodiversity. The higher invertebrate biomass did not translate into a higher fish density in the treated areas. The results of this study indicated that partial mechanical removal is a suitable option to control unwanted macrophyte stands.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study compared pregnancy rates (PRs) and costs per calf born after fixed-time artificial insemination (FTAI) or AI after estrus detection (i.e., estrus detection and AI, EDAI), before and after a single PGF2α treatment in Bos indicus (Brahman-cross) heifers. On Day 0, the body weight, body condition score, and presence of a CL (46% of heifers) were determined. The heifers were then alternately allocated to one of two FTAI groups (FTAI-1, n = 139) and (FTAI-2, n = 141) and an EDAI group (n = 273). Heifers in the FTAI groups received an intravaginal progesterone-releasing device (IPRD; 0.78 g of progesterone) and 1 mg of estradiol benzoate intramuscularly (im) on Day 0. Eight days later, the IPRD was removed and heifers received 500 μg of PGF2α and 300 IU of eCG im; 24 hours later, they received 1 mg estradiol benzoate im and were submitted to FTAI 30 to 34 hours later (54 and 58 hours after IPRD removal). Heifers in the FTAI-2 group started treatment 8 days after those in the FTAI-1 group. Heifers in the EDAI group were inseminated approximately 12 hours after the detection of estrus between Days 4 and 9 at which time the heifers that had not been detected in estrus received 500 μg of PGF2α im and EDAI continued until Day 13. Heifers in the FTAI groups had a higher overall PR (proportion pregnant as per the entire group) than the EDAI group (34.6% vs. 23.2%; P = 0.003), however, conception rate (PR of heifers submitted for AI) tended to favor the estrus detection group (34.6% vs. 44.1%; P = 0.059). The cost per AI calf born was estimated to be $267.67 and $291.37 for the FTAI and EDAI groups, respectively. It was concluded that in Brahman heifers typical of those annually mated in northern Australia FTAI compared with EDAI increases the number of heifers pregnant and reduces the cost per calf born.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The advent of retrievable caval filters was a game changer in the sense, that the previously irreversible act of implanting a medical device into the main venous blood stream of the body requiring careful evaluation of the pros and cons prior to execution suddenly became a "reversible" procedure where potential hazards in the late future of the patient lost most of their weight at the time of decision making. This review was designed to assess the rate of success with late retrieval of so called retrievable caval filters in order to get some indication about reasonable implant duration with respect to relatively "easy" implant removal with conventional means, i.e., catheters, hooks and lassos. A PubMed search (www.pubmed.gov) was performed with the search term "cava filter retrieval after 30 days clinical", and 20 reports between 1994 and 2013 dealing with late retrieval of caval filters were identified, covering approximately 7,000 devices with 600 removed filters. The maximal duration of implant reported is 2,599 days and the maximal implant duration of removed filters is also 2,599 days. The maximal duration reported with standard retrieval techniques, i.e., catheter, hook and/or lasso, is 475 days, whereas for the retrievals after this period more sophisticated techniques including lasers, etc. were required. The maximal implant duration for series with 100% retrieval accounts for 84 days, which is equivalent to 12 weeks or almost 3 months. We conclude that retrievable caval filters often become permanent despite the initial decision of temporary use. However, such "forgotten" retrievable devices can still be removed with a great chance of success up to three months after implantation. Conventional percutaneous removal techniques may be sufficient up to sixteen months after implantation whereas more sophisticated catheter techniques have been shown to be successful up to 83 months or more than seven years of implant duration. Tilting, migrating, or misplaced devices should be removed early on, and replaced if indicated with a device which is both, efficient and retrievable.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Le desserrage des tiges est une complication fréquente des plâtres avec tiges transcorticales (TP) chez les grands animaux, nécessitant souvent leur retrait prématuré avant la guérison des fractures. Les charges excessives centrées sur le cortex à l’interface os-tige proximo-externe et disto-interne causent de l'ostéolyse. En utilisant un modèle de veau nouveau-né, ce projet a évalué un nouveau système de tige-manchon et anneau integré dans un plâtre (PS) optimisé pour réduire la contrainte péri-implant et le stress à l'interface os-implant. On a émis l'hypothèse que les PS se traduiraient par une ostéolyse péri-implant moindre par rapport aux TP. Dix veaux en bonne santé, de 3 semaines d'âge, ont été implantés avec les TP ou PS dans le métacarpe droit, à raison de 2 implants par veau. Les veaux ont été observés quotidiennement pour le confort et la boiterie et ont été euthanasiés à 28 jours. Les données recueillies comprenaient les radiographies à la chirurgie et à l'euthanasie et les mesures histomorphométriques de contact os-implant sur des échantillons non-décalcifiés avec les implants in situ. Les données ont été analysées en utilisant le test de Cochran-Mantel-Haenszel, une valeur de P <0,05 a été considérée comme significative. L'épaisseur corticale était plus importante pour les implants distaux que proximaux pour les deux groupes lors de la chirurgie (P = 0,03), mais était similaire entre les groupes (P > 0,3). Les veaux avec TP ont développé une boiterie plus tôt (au jour 21) que les veaux avec PS (P = 0,04). Histologiquement, il y avait plus de contact direct os-implant cortical pour les implants PS distaux que les implants TP (P = 0,04). La jonction métaphyso-diaphysaire osseuse où les implants proximaux étaient situés est impropre aux deux systèmes; chacun a un minimum de contact os-implant et de l'ostéolyse extensive. Le système PS n'ayant pas causé une ostéolyse importante lorsque implantés dans l'os diaphysaire et peut-être une alternative convenable aux TP pour des fractures comminutives des membres distaux.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Laser hair removal is becoming an increasingly popular alternative to traditional methods such as shaving, waxing, among other methods. Semiconductor diode lasers are considered the most efficient light sources available and are especially well suited for clinical applications including hair reduction. The effectiveness of laser hair reduction depends on many variables, including the skin type of the patient. Material and Methods: A patient with Fitzpatrick Skin Type IV was submitted to laser hair removal of the arms with a high-power diode laser system with long pulses with a wavelength of 800 nm, a fluence of 40 J/cm2 and a pulse width of 20 ms. A 12-month follow-up assessment was performed and included photography and questionnaire. Results: Hypopigmentation was observed after a single laser hair removal section. After 6 months with the area totally covered, a gradual suntan with a sun screen lotion with an SPF of 15 was prescribed by the dermatologist. After 12 months of the initial treatment, a complete recovery of the hypopigmentation was achieved. Conclusion: Although a safe procedure, lasers for hair removal may be associated with adverse side effects including undesired pigment alterations. Before starting a laser hair removal treatment, patients seeking the eradication of hair should be informed that temporary, and possibly permanent, pigmentary changes may occur. © 2013 Informa UK, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Laser hair removal is becoming an increasingly popular alternative to traditional methods such as shaving, waxing, among other methods. Semiconductor diode lasers are considered the most efficient light sources available and are especially well suited for clinical applications including hair reduction. The effectiveness of laser hair reduction depends on many variables, including the skin type of the patient. Material and Methods: A patient with Fitzpatrick Skin Type IV was submitted to laser hair removal of the arms with a high-power diode laser system with long pulses with a wavelength of 800 nm, a fluence of 40 J/cm2 and a pulse width of 20 ms. A 12-month follow-up assessment was performed and included photography and questionnaire. Results: Hypopigmentation was observed after a single laser hair removal section. After 6 months with the area totally covered, a gradual suntan with a sun screen lotion with an SPF of 15 was prescribed by the dermatologist. After 12 months of the initial treatment, a complete recovery of the hypopigmentation was achieved. Conclusion: Although a safe procedure, lasers for hair removal may be associated with adverse side effects including undesired pigment alterations. Before starting a laser hair removal treatment, patients seeking the eradication of hair should be informed that temporary, and possibly permanent, pigmentary changes may occur.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A 5-½-month-old female Holstein-Friesian calf was presented with a history of recurring ruminal tympany and poor development. The absence of lung sounds on the right hemithorax suggested a right-sided intrathoracic pathology. Radiography and computed tomography revealed a large thin-walled cavernous lesion with a gas-fluid interface which almost completely filled the right thoracic cavity. Fluid aspirated from the lesion was clear, yellowish and odorless. These findings led to the diagnosis of a bronchogenic cyst. Thoracotomy was performed under general anesthesia. The cyst strongly adhered to the adjacent lung tissue. After removal of the free wall, the adjacent lung tissue was sealed using surgical stapling instruments, and the non-removable part of the wall was curetted and rinsed. The intensive postoperative management included antibiotic therapy, oxygen supplementation and regional lidocaine infusion. Anti-inflammatory drugs were administered for further pain control. The calf recovered well and was released from the clinic on postoperative day 11. Intra- or extrathoracic bronchogenic cysts result from abnormal budding during the embryonic development of the tracheobronchial system. Successful treatment of this calf despite the size of the lesion and the invasive character of the surgical intervention indicates that resection of bronchogenic cysts in cattle may be an option for valuable animals.