997 resultados para Temporal measurements


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel shear plate was used to make direct bed shear stress measurements in laboratory dam break and swash flows on smooth, fixed, impermeable beds. The pressure gradient due to the slope of the fluid free-surface across the plate was measured using pressure transducers. Surface elevation was measured at five locations using acoustic displacement sensors. Flow velocity was measured using an Acoustic-Doppler Velocimeter and calculated using the ANUGA inundation model. The measured bed shear stress at the dam break fluid tip for an initially dry, horizontal bed was close to twice that estimated using steady flow theory. The temporal variation of swash bed shear stress showed a large peak in landward directed stress at the uprush tip, followed by a rapid decay throughout the uprush flow interior. The peak seaward directed stress during the backwash phase was less than half that measured in the uprush. Close to the still water line, in the region of bore collapse and at the time of initial uprush, favourable pressure gradients were measured. In the lower swash region predominately weak adverse pressure gradients were measured.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose The aim of this study was to test the correlation between Fourier-domain (FD) optical coherence tomography (OCT) macular and retinal nerve fibre layer (RNFL) thickness and visual field (VF) loss on standard automated perimetry (SAP) in chiasmal compression. Methods A total of 35 eyes with permanent temporal VF defects and 35 controls underwent SAP and FD-OCT (3D OCT-1000; Topcon Corp.) examinations. Macular thickness measurements were averaged for the central area and for each quadrant and half of that area, whereas RNFL thickness was determined for six sectors around the optic disc. VF loss was estimated in six sectors of the VF and in the central 16 test points in the VF. The correlation between VF loss and OCT measurements was tested with Spearman`s correlation coefficients and with linear regression analysis. Results Macular and RNFL thickness parameters correlated strongly with SAP VF loss. Correlations were generally stronger between VF loss and quadrantic or hemianopic macular thickness than with sectoral RNFL thickness. For the macular parameters, we observed the strongest correlation between macular thickness in the inferonasal quadrant and VF loss in the superior temporal central quadrant (rho=0.78; P<0.001) whereas for the RNFL parameters the strongest correlation was observed between the superonasal optic disc sector and the central temporal VF defect (rho=0.60; P<0.001).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The spatial and temporal evolution of a depleted atomic distribution created by laser enhanced ionisation (LEI) was employed to determine both a diffusion coefficient for sodium (Na) and an electron (e(-)) and sodium ion recombination rate coefficient in an analytical air-C2H2 flame. A depleted distribution of neutral sodium atoms was produced in a flame by ionising approximately 80% of the irradiated sodium atoms in a well defined region using a two step LEI excitation scheme. Following depletion by ionisation, planar laser induced fluorescence (PLIF) images of the depleted region recorded the diffusion and decay of the depleted Na distribution for different depletion-probe delays. From measurements of the diffused width of the distribution, an accurate diffusion coefficient D = (1.19 +/- 0.03) x 10(-3) m(2) s(-1) for Na was determined in teh burnt gases of the flame. Measurements of the integrated fluorescence intensity in the depleted region for different depletion-probe delays were related to an increase in atomic sodium concentration caused by electron-ion recombination. At high concentrations (greater than or equal to 50 mu g ml(-1)), where the electron and ion concentrations in the depleted region were assumed equal, a recombination rate coefficient of 4.2 x 10(-9) cm(3) s(-1) was calculated. (C) 1997 Elsevier Science B.V.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Here, we examine morphological changes in cortical thickness of patients with Alzheimer`s disease (AD) using image analysis algorithms for brain structure segmentation and study automatic classification of AD patients using cortical and volumetric data. Cortical thickness of AD patients (n = 14) was measured using MRI cortical surface-based analysis and compared with healthy subjects (n = 20). Data was analyzed using an automated algorithm for tissue segmentation and classification. A Support Vector Machine (SVM) was applied over the volumetric measurements of subcortical and cortical structures to separate AD patients from controls. The group analysis showed cortical thickness reduction in the superior temporal lobe, parahippocampal gyrus, and enthorhinal cortex in both hemispheres. We also found cortical thinning in the isthmus of cingulate gyrus and middle temporal gyrus at the right hemisphere, as well as a reduction of the cortical mantle in areas previously shown to be associated with AD. We also confirmed that automatic classification algorithms (SVM) could be helpful to distinguish AD patients from healthy controls. Moreover, the same areas implicated in the pathogenesis of AD were the main parameters driving the classification algorithm. While the patient sample used in this study was relatively small, we expect that using a database of regional volumes derived from MRI scans of a large number of subjects will increase the SVM power of AD patient identification.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Three patients with progressive visual loss, chronic alcoholism and tabagism were submitted to a complete neuro-ophthalmic examination and to retinal nerve fiber layer (RNFL) measurements using optical coherence tomography (OCT) scanning. Two patients showed marked RNFL loss in the temporal sector of the optic disc. However, a third patient presented RNFL measurements within or above normal limits, based on the Stratus-OCT normative database. Such findings may be due to possible RNFL edema similar to the one that may occur in the acute phase of toxic optic neuropathies. Stratus-OCT was able to detect RNFL loss in the papillomacular bundle of patients with tobacco-alcohol-induced toxic optic neuropathy. However, interpretation must be careful when OCT does not show abnormality in order to prevent diagnostic confusion, since overestimation of RNFL thickness measurements is possible in such cases.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE. To evaluate the relationship between pattern electroretinogram (PERG) amplitude, macular and retinal nerve fiber layer (RNFL) thickness by optical coherence tomography (OCT), and visual field (VF) loss on standard automated perimetry (SAP) in eyes with temporal hemianopia from chiasmal compression. METHODS. Forty-one eyes from 41 patients with permanent temporal VF defects from chiasmal compression and 41 healthy subjects underwent transient full-field and hemifield (temporal or nasal) stimulation PERG, SAP and time domain-OCT macular and RNFL thickness measurements. Comparisons were made using Student`s t-test. Deviation from normal VF sensitivity for the central 18 of VF was expressed in 1/Lambert units. Correlations between measurements were verified by linear regression analysis. RESULTS. PERG and OCT measurements were significantly lower in eyes with temporal hemianopia than in normal eyes. A significant correlation was found between VF sensitivity loss and fullfield or nasal, but not temporal, hemifield PERG amplitude. Likewise a significant correlation was found between VF sensitivity loss and most OCT parameters. No significant correlation was observed between OCT and PERG parameters, except for nasal hemifield amplitude. A significant correlation was observed between several macular and RNFL thickness parameters. CONCLUSIONS. In patients with chiasmal compression, PERG amplitude and OCT thickness measurements were significant related to VF loss, but not to each other. OCT and PERG quantify neuronal loss differently, but both technologies are useful in understanding structure-function relationship in patients with chiasmal compression. (ClinicalTrials.gov number, NCT00553761.) (Invest Ophthalmol Vis Sci. 2009; 50: 3535-3541) DOI:10.1167/iovs.08-3093

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau em Mestre em Engenharia Física

Relevância:

30.00% 30.00%

Publicador:

Resumo:

RESUMO - O doseamento da protoporfirina-zinco (PPZ) vem sendo preconizado como indicador a utilizar em primeira linha nos programas de monitorização biológica da exposição profissional a chumbo. A PPZ apresenta um elevado grau de associação com a plumbemia e representa, num dado momento, o efeito metabólico do chumbo sobre a ferro- -quelatase (enzima catalisadora da incorporação do ferro na protoporfirina IX) ao longo dos anteriores cerca de três meses. Num estudo incidindo sobre 67 trabalhadores expostos a chumbo, do sexo masculino, os autores avaliaram a variação da PPZ em relação à plumbemia determinada num determinado momento (t0) e em sucessivos doseamentos efectuados cerca de 30 (t1), 60 (t2) e 90 (t3) dias após esse momento. Da análise dos resultados obtidos conclui-se que em trabalhadores expostos a chumbo de modo considerado estável (com níveis de Pb-S entre 30 e 78 μg/dL) a PPZ não variou significativamente ao longo do período de tempo considerado. Deste modo, parece poder concluir-se que os resultados de PPZ são representativos do nível de exposição (inferida pelos níveis de dose interna) pelo menos em relação ao período de cerca de três meses anteriores, correspondendo à resposta orgânica consequente à dose em causa.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Programa Doutoral em Matemática e Aplicações.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A method has been developed for the determination of the oxygen uptake of small areas (0.01 mm2) in an entire chick embryo cultured in vitro under defined metabolic conditions. It is based on the recordings of the spectral changes of the hemoglobin used as oxygen source for the respiring tissue (Barzu and Borza, 1967). Rapid scanning of the hemoglobin absorbance over the preparation allows a comparison of the O2 uptake of various regions. Values of the order of 10(-2) 1 O2 . min-2 are measured in less than 10 sec with a spatial resolution of 100 micron. The differentiation of embryonic tissue is not disturbed by the measurements. The O2 diffusion in the media and in the tissue has been analyzed by digital simulation. The O2 uptake of the Hensen's node was measured from embryos starting at the stage of definitive primitive streak (stage 4) up to the stage of 10 somites. It increases from 0.6 to 1.1 nl . h-1 with a marked acceleration between stages 4 and 5. The values corrected for the protein content of the Hensen's node at stage 4, 5, 6 and 8 are 32, 30 and 28 microliter . mg-1 . h-1 respectively. The first scanning results show different patterns of the O2 utake at the level of the Hensen's node and of the neural plate. At stage 6-7, the corrected O2 uptake is 30 microliter . mg-1 . h-1 for . the former and 43 microliter . mg-1 . h-1 for the latter.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: Anhedonia is defined as a diminished capacity to experience pleasant emotion and is commonly included among the negative symptoms of schizophrenia. However, if patients report experiencing a lower level of pleasure than controls, they report experiencing as much pleasure as controls with online measurements of emotion. OBJECTIVE: The Temporal Experience of Pleasure Scale (TEPS) measures pleasure experienced in the moment and in anticipation of future activities. The TEPS is an 18-item self-report measurement of anticipatory (10 items) and consummatory (eight items) pleasure. The goal of this paper is to assess the psychometric characteristics of the French translation of this scale. METHODS: A control sample was composed of 60 women and 22 men, with a mean age of 38.1 years (S.D.: 10.8). Thirty-six were without qualification and 46 with qualified professional diploma. A sample of 21 patients meeting DSM IV-TR criteria for schizophrenia was recruited among the community psychiatry service of the department of psychiatry in Lausanne. They were five women and 16 men; mean age was of 34.1 years (S.D.: 7.5). Ten obtained a professional qualification and 11 were without qualification. None worked in competitive employment. Their mean dose of chlorpromazine equivalent was 431mg (S.D.: 259). All patients were on atypical antipsychotics. The control sample fulfilled the TEPS and the Physical Anhedonia Scale (PAS). The patient sample fulfilled the TEPS and was independently rated on the Calgary Depression Scale and the Scale for Assessment of Negative Symptoms. For comparison with controls, patients were matched on age, sex and professional qualification. This required the supplementary recruitment of two control subjects. RESULTS: Results with the control sample indicate that the TEPS presents an acceptable internal validity with Crombach alphas of 0.84 for the total scale, 0.74 for the anticipatory pleasure scale and 0.79 for the consummatory pleasure scale. The confirmatory factor analysis indicated that the model is well adapted to our data (chi(2)/dl=1.333; df=134; p<0.0006; root mean square residual, RMSEA=0.064). External validity measured with the PAS showed R=-0.27 (p<0.05) for the consummatory scale and R=-0.26 for the total score. Comparisons between patients and matched controls indicated that patients were significantly lower than control on anticipatory pleasure (t=2.7, df(40), 2-tailed p=0.01; cohen's d=0.83) and on total score of the TEPS (t=2.8, df (40), 2-tailed p=0.01; cohen's d=0.87). The two samples did not differ on consummatory pleasure. The anticipatory pleasure factor and the total TEPS showed significant negative correlation with the SANS anhedonia, respectively R=-0.78 (p<0.01) for the anticipatory factor and R=-0.61 (p<0.01) for the total TEPS. There was also a negative correlation between the anticipatory factor and the SANS avolition of R=-0.50 (p<0.05). These correlations were maintained, with partial correlations controlling for depression and chlorpromazine equivalents. CONCLUSION: The results of this validation show that the French version of the TEPS has psychometric characteristics similar to the original version. These results highlight the discrepancy between results of direct or indirect report of experienced pleasure in patients with schizophrenia. Patients may have difficulties in anticipating the pleasure of future enjoyable activities, but not in experiencing pleasure once in an enjoyable activity. Medication and depression do not seems to modify our results, but this should be better controlled in a longitudinal study. The anticipatory versus consummatory pleasure distinction appears to be useful for the development of new psychosocial interventions, tailored to improve desire in patients suffering from schizophrenia. Major limitations of the study are the small size of patient sample and the under representation of men in the control sample.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Sediment-water exchanges of oxygen, ammonium, nitrate, total dissolved nitrogen, phosphate and total dissolved phosphorus were measured by means of an in situ incubator of 7 1 volume and 700 cm2 base area. The incubations lasted for three hours and were done over a whole season on different kinds of sediments in Alfaques Bay. We present some preliminary results on: i) methodological aspects, ii) spatial and temporal variability of fluxes, and iii) estimates of contribution of benthic nutrient regeneration relative to total nutrient loading of the Bay. Oxygen uptake averaged 1700 mmo1 m-2 h-1 (range 200-3500); no differences were found between sandy and muddy sediments. The release of ammonia from the sediment averaged 70 mmo1 m-2 h-1 and was higher in muddy sediments than in sandy ones. Very low to null nitrate and nitrite fluxes and only small fluxes of organic nitrogen were detected. We conclude that ammonium release from sediment is the major path of nitrogen regeneration. Some sediments removed dissolved reactive phosphorus (DRP) from the water and released dissolved organic phosphorus (DOP). Additional manipulative experiments revealed DRP release under particular conditions (turbulence, anoxia). From these data, we estimate that at least 50% of the nitrogen requirements of phytoplankton in the area may be supplied by benthic remineralization.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The quantification of gene expression at the single cell level uncovers novel regulatory mechanisms obscured in measurements performed at the population level. Two methods based on microscopy and flow cytometry are presented to demonstrate how such data can be acquired. The expression of a fluorescent reporter induced upon activation of the high osmolarity glycerol MAPK pathway in yeast is used as an example. The specific advantages of each method are highlighted. Flow cytometry measures a large number of cells (10,000) and provides a direct measure of the dynamics of protein expression independent of the slow maturation kinetics of the fluorescent protein. Imaging of living cells by microscopy is by contrast limited to the measurement of the matured form of the reporter in fewer cells. However, the data sets generated by this technique can be extremely rich thanks to the combinations of multiple reporters and to the spatial and temporal information obtained from individual cells. The combination of these two measurement methods can deliver new insights on the regulation of protein expression by signaling pathways.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Ankle arthrodesis (AD) and total ankle replacement (TAR) are typical treatments for ankle osteoarthritis (AO). Despite clinical interest, there is a lack of their outcome evaluation using objective criteria. Gait analysis and plantar pressure assessment are appropriate to detect pathologies in orthopaedics but they are mostly used in lab with few gait cycles. In this study, we propose an ambulatory device based on inertial and plantar pressure sensors to compare the gait during long-distance trials between healthy subjects (H) and patients with AO or treated by AD and TAR. Methods: Our study included four groups: 11 patients with AO, 9 treated by TAR, 7 treated by AD and 6 control subjects. An ambulatory system (Physilog®, CH) was used for gait analysis; plantar pressure measurements were done using a portable insole (Pedar®-X, DE). The subjects were asked to walk 50 meters in two trials. Mean value and coefficient of variation of spatio-temporal gait parameters were calculated for each trial. Pressure distribution was analyzed in ten subregions of foot. All parameters were compared among the four groups using multi-level model-based statistical analysis. Results: Significant difference (p <0.05) with control was noticed for AO patients in maximum force in medial hindfoot and forefoot and in central forefoot. These differences were no longer significant in TAR and AD groups. Cadence and speed of all pathologic groups showed significant difference with control. Both treatments showed a significant improvement in double support and stance. TAR decreased variability in speed, stride length and knee ROM. Conclusions: In spite of a small sample size, this study showed that ankle function after AO treatments can be evaluated objectively based on plantar pressure and spatio-temporal gait parameters measured during unconstrained walking outside the lab. The combination of these two ambulatory techniques provides a promising way to evaluate foot function in clinics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present study proposes a method based on ski fixed inertial sensors to automatically compute spatio-temporal parameters (phase durations, cycle speed and cycle length) for the diagonal stride in classical cross-country skiing. The proposed system was validated against a marker-based motion capture system during indoor treadmill skiing. Skiing movement of 10 junior to world-cup athletes was measured for four different conditions. The accuracy (i.e. median error) and precision (i.e. interquartile range of error) of the system was below 6ms for cycle duration and ski thrust duration and below 35ms for pole push duration. Cycle speed precision (accuracy) was below 0.1m/s (0.005m/s) and cycle length precision (accuracy) was below 0.15m (0.005m). The system was sensitive to changes of conditions and was accurate enough to detect significant differences reported in previous studies. Since capture volume is not limited and setup is simple, the system would be well suited for outdoor measurements on snow.