992 resultados para Target acquisition


Relevância:

60.00% 60.00%

Publicador:

Resumo:

设计了一种深空非合作目标的激光扫描、捕获、跟踪地面实验装置,通过模拟深空同轨道运动的两颗卫星跟瞄过程,在理论上计算了跟瞄装置中光束指向驱动电机的最小加速度和其在跟踪过程中的运动特性。理论分析与仿真结果表明,当卫星偏离光斑中心一定距离时,指向驱动电机先加速后减速,补偿这个偏心,重新捕获跟踪卫星;重新捕获到跟踪所需时间受电机加速度和望远镜探测精度以及探测器响应处理时间影响,其中探测器精度对重新捕获到跟踪所需时间影响较大,探测器响应处理时间要减小到最小;为了使从捕获到跟踪过程中卫星始终在扫描光斑范围内,经纬仪驱动电机的最小角加速度为25.5°/s2。

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We investigated visuomotor adaptation using an isometric, target-acquisition task. Following trials with no rotation, two participant groups were exposed to a random sequence of 30 degrees clockwise (CW) and 60 degrees counter-clockwise (CCW) rotations, with (DUAL-CUE), or without (DUAL-NO CUE), colour cues that enabled each environment (non-rotated, 30 degrees CW and 60 degrees CCW) to be identified. A further three groups experienced only 30 degrees CW trials or only 60 degrees CCW trials (SINGLE rotation groups) in which each visuomotor mapping was again associated with a colour cue. During training, all SINGLE groups reduced angular deviations of the cursor path during the initial portion of the movements, indicating feedforward adaptation. Consistent with the view that the adaptation occurred automatically via recalibration of the visuomotor mapping (Krakauer et al. 1999), post-training aftereffects were observed, despite colour cues that indicated that no rotation was present. For the DUAL-CUE group, angular deviations decreased with training in the 60 degrees trials, but were unchanged in the 30 degrees trials, while for the DUAL-NO CUE group angular deviations decreased for the 60 degrees CW trials but increased for the 30 degrees CW trials. These results suggest that in a dual adaptation paradigm a colour cue can permit delineation of the two environments, with a subsequent change in behaviour resulting in improved performance in at least one of these environments. Increased reaction times within the training block, together with the absence of aftereffects in the post-training period for the DUAL-CUE group suggest an explicit cue-dependent strategy was used in an attempt to compensate for the rotations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this study was to examine the capacity of resistance training to enhance the rapid and coordinated production of force by older people. Thirty adults (greater than or equal to 60 years) completed a visually guided aiming task that required the generation of isometric torque in 2 df about the elbow prior to and following a 4-week training period. Groups of six participants were allocated to two progressive ( 40 - 100% maximal voluntary contraction (MVC)) resistance-training (PRT) groups, to two constant low-load (10% MVC) training groups (CLO) and to one no-training control group. Training movements required the generation of either combined flexion and supination (FLESUP), or combined extension and supination (EXTSUP). In response to training, target acquisition times in the aiming task decreased for all groups; however, both the nature of the training load and the training movement influenced the pattern and magnitude of improvements (EXTSUP_ CLO: 36%, FLESUP_ PRT 26%, EXTSUP_ PRT 22%, FLESUP_ CLO 20%, CONTROL 15%). For one group that trained with progressively increasing loads, there arose a subsequent decrease in performance in one condition of the transfer task. For each group, these adaptations were accompanied by systematic changes in the coordination of muscles about the elbow joint, particularly the biceps brachii.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A 94 GHz waveguide Rotman lens is described which can be used to implement an amplitude comparison monopulse RADAR. In transmit mode, adjacent dual beam ports are excited with equal amplitude and phase to form a sum radiation pattern, and in receive mode, the outputs of the beam port pairs are combined using magic tees to provide a sum and a difference signal which can be used to calculate an angular error estimate for target acquisition and tracking. This approach provides an amplitude comparison monopulse system which can be scanned in azimuth and which has a low component count, with no requirement for phase shift circuitry in the array feed lines, making it suitable for mm-wave frequencies. A 12 input (beam ports), 12 output (array ports) lens is designed using CST Microwave Studio, and the predicted results are presented.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study investigates the extent to which advanced native-English L2 learners of Spanish come to acquire restrictions on bare plural preverbal subjects in L2 Spanish (e.g. gatos “cats” vs. definite plurals such as los gatos “the cats”). It tests L2 knowledge of available semantic readings of bare plurals and definite plurals in Spanish, where [+specific] and [+generic] interpretations are syntactically represented differently from English. Assuming L1 transfer, and in view of a potential subset/superset relationship of the two grammars, the learning task in this domain is not a straightforward one. Target acquisition requires both grammatical expansion and retraction; Spanish definite plural subjects require the addition of an L1-unavailable [+generic] reading, while a loss of an L1-available [+generic] reading for preverbal subject bare plurals is required. The results and analysis show that advanced L2 learners of Spanish (English L1) can circumvent a superficial subset/superset learnability problem by means of feature resetting in line with the Nominal Mapping Parameter.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We describe the planning, implementation, and initial results of the first planned move of the default position of spectra on the Hubble Space Telescope's Cosmic Origins Spectrograph (COS) Far Ultraviolet (FUV) cross-delay line detector. This was motivated by the limited amount of charge that can be extracted from the microchannel plate due to gain sag at any one position. Operations at a new location began on July 23, 2012, with a shift of the spectrum by +3.5"(corresponding to ~ 41 pixels or ~ 1 mm) in a direction orthogonal to the spectral dispersion. Operation at this second "lifetime position" allows for spectra to be collected which are not affected by detector artifacts and loss of sensitivity due to gain sag. We discuss programs designed to enable operations at the new lifetime position; these include determinations of operational high voltage, measuring walk corrections and focus, confirming spectrum placement and aperture centering, and target acquisition performance. We also present results related to calibration of the new lifetime position, including measurements of spectral resolution and wavelength calibration, flux and flat field calibration, carryover of time-dependent sensitivity monitoring, and operations with the Bright Object Aperture (BOA).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this study was to examine the capacity of resistance training to enhance the rapid and coordinated production of force by older people. Thirty adults (greater than or equal to 60 years) completed a visually guided aiming task that required the generation of isometric torque in 2 df about the elbow prior to and following a 4-week training period. Groups of six participants were allocated to two progressive ( 40 - 100% maximal voluntary contraction (MVC)) resistance-training (PRT) groups, to two constant low-load (10% MVC) training groups (CLO) and to one no-training control group. Training movements required the generation of either combined flexion and supination (FLESUP), or combined extension and supination (EXTSUP). In response to training, target acquisition times in the aiming task decreased for all groups; however, both the nature of the training load and the training movement influenced the pattern and magnitude of improvements (EXTSUP_ CLO: 36%, FLESUP_ PRT 26%, EXTSUP_ PRT 22%, FLESUP_ CLO 20%, CONTROL 15%). For one group that trained with progressively increasing loads, there arose a subsequent decrease in performance in one condition of the transfer task. For each group, these adaptations were accompanied by systematic changes in the coordination of muscles about the elbow joint, particularly the biceps brachii.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background. Older adults typically exhibit dramatic reductions in the rate of force development and deficits in the execution of rapid coordinated movements. The purpose of the current study was to investigate the association between the reduced rate of force development exhibited by older adults and the ability to coordinate groups of muscles. Methods. The performance of a visually guided aiming task that required the generation of isometric torque about the elbow joint was compared in 10 young adults (age range, 19 to 29 years) and 10 older adults (age range, 65 to 80 years). Participants were required to exert isometric torque in flexion, extension, pronation, or supination, or in combinations of these directions, to reach a target in minimum time. Surface electromyograms were obtained from the biceps brachii, triceps brachii, brachioradialis, and flexor carpi radialis. Results. Older participants exhibited slower target acquisition times compared with young participants (p < .05), with the extent of the differences between the groups varying markedly between target locations. Conclusions. The impairment in performance, although partially attributable to a general decline in the ability to produce force rapidly, was also affected by the requirements for muscular coordination. At the neuromuscular level, differences between the young and the elderly were expressed most prominently in the bifunctional muscle biceps brachii and in certain temporal aspects of muscular coordination.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The authors argue that human desire involves conscious cognition that has strong affective connotation and is potentially involved in the determination of appetitive behavior rather than being epiphenomenal to it. Intrusive thoughts about appetitive targets are triggered automatically by external or physiological cues and by cognitive associates. When intrusions elicit significant pleasure or relief, cognitive elaboration usually ensues. Elaboration competes with concurrent cognitive tasks through retrieval of target-related information and its retention in working memory. Sensory images are especially important products of intrusion and elaboration because they simulate the sensory and emotional qualities of target acquisition. Desire images are momentarily rewarding but amplify awareness of somatic and emotional deficits. Effects of desires on behavior are moderated by competing incentives, target availability, and skills. The theory provides a coherent account of existing data and suggests new directions for research and treatment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aims: To develop clinical protocols for acquiring PET images, performing CT-PET registration and tumour volume definition based on the PET image data, for radiotherapy for lung cancer patients and then to test these protocols with respect to levels of accuracy and reproducibility. Method: A phantom-based quality assurance study of the processes associated with using registered CT and PET scans for tumour volume definition was conducted to: (1) investigate image acquisition and manipulation techniques for registering and contouring CT and PET images in a radiotherapy treatment planning system, and (2) determine technology-based errors in the registration and contouring processes. The outcomes of the phantom image based quality assurance study were used to determine clinical protocols. Protocols were developed for (1) acquiring patient PET image data for incorporation into the 3DCRT process, particularly for ensuring that the patient is positioned in their treatment position; (2) CT-PET image registration techniques and (3) GTV definition using the PET image data. The developed clinical protocols were tested using retrospective clinical trials to assess levels of inter-user variability which may be attributed to the use of these protocols. A Siemens Somatom Open Sensation 20 slice CT scanner and a Philips Allegro stand-alone PET scanner were used to acquire the images for this research. The Philips Pinnacle3 treatment planning system was used to perform the image registration and contouring of the CT and PET images. Results: Both the attenuation-corrected and transmission images obtained from standard whole-body PET staging clinical scanning protocols were acquired and imported into the treatment planning system for the phantom-based quality assurance study. Protocols for manipulating the PET images in the treatment planning system, particularly for quantifying uptake in volumes of interest and window levels for accurate geometric visualisation were determined. The automatic registration algorithms were found to have sub-voxel levels of accuracy, with transmission scan-based CT-PET registration more accurate than emission scan-based registration of the phantom images. Respiration induced image artifacts were not found to influence registration accuracy while inadequate pre-registration over-lap of the CT and PET images was found to result in large registration errors. A threshold value based on a percentage of the maximum uptake within a volume of interest was found to accurately contour the different features of the phantom despite the lower spatial resolution of the PET images. Appropriate selection of the threshold value is dependant on target-to-background ratios and the presence of respiratory motion. The results from the phantom-based study were used to design, implement and test clinical CT-PET fusion protocols. The patient PET image acquisition protocols enabled patients to be successfully identified and positioned in their radiotherapy treatment position during the acquisition of their whole-body PET staging scan. While automatic registration techniques were found to reduce inter-user variation compared to manual techniques, there was no significant difference in the registration outcomes for transmission or emission scan-based registration of the patient images, using the protocol. Tumour volumes contoured on registered patient CT-PET images using the tested threshold values and viewing windows determined from the phantom study, demonstrated less inter-user variation for the primary tumour volume contours than those contoured using only the patient’s planning CT scans. Conclusions: The developed clinical protocols allow a patient’s whole-body PET staging scan to be incorporated, manipulated and quantified in the treatment planning process to improve the accuracy of gross tumour volume localisation in 3D conformal radiotherapy for lung cancer. Image registration protocols which factor in potential software-based errors combined with adequate user training are recommended to increase the accuracy and reproducibility of registration outcomes. A semi-automated adaptive threshold contouring technique incorporating a PET windowing protocol, accurately defines the geometric edge of a tumour volume using PET image data from a stand alone PET scanner, including 4D target volumes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study investigates the characteristics and attributes that private equity investors prefer when selecting target acquisitions. These characteristics are examined against a matched sample of firms subject to corporate acquisitions via tender/merger offer during 2000-2009, across seven countries: Australia, Canada, the United Kingdom, the USA, France, Germany and Sweden. We show that firm-specific characteristics are more influential in target selection than external or institutional variables. In particular, private equity targets exhibit lower stock volatility and long-term growth prospects, are larger, and have greater abnormal operating income relative to tender/merger offer target firms. Further, private equity bidders exhibit 'home bias', implying that familiarity motivates target selection. Institutional factors remain largely insignificant across all tests.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Both the United States and Canada have federal legislation that attempts to address employment inequities across specific target groups. The US has a long tradition of affirmative action, dating back to President Kennedy’s 1961 Executive Order; Canada enacted its Employment Equity Act in 1986. Employment Equity/Affirmative Action policy has attracted significant controversy, with high profile court cases and the repeal of state/provincial legislation. Coate and Loury (1993) examine the theoretical impact of introducing affirmative action. Unfortunately the theoretical impact of affirmative action is ambiguous. The current paper employs a laboratory experiment to shed empirical light on this theoretical ambiguity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Approximately half of prostate cancers (PCa) carry TMPRSS2-ERG translocations; however, the clinical impact of this genomic alteration remains enigmatic. Expression of v-ets erythroblastosis virus E26 oncogene like (avian) gene (ERG) promotes prostatic epithelial dysplasia in transgenic mice and acquisition of epithelial-to-mesenchymal transition (EMT) characteristics in human prostatic epithelial cells (PrECs). To explore whether ERG-induced EMT in PrECs was associated with therapeutically targetable transformation characteristics, we established stable populations of BPH-1, PNT1B and RWPE-1 immortalized human PrEC lines that constitutively express flag-tagged ERG3 (fERG). All fERG-expressing populations exhibited characteristics of in vitro and in vivo transformation. Microarray analysis revealed >2000 commonly dysregulated genes in the fERG-PrEC lines. Functional analysis revealed evidence that fERG cells underwent EMT and acquired invasive characteristics. The fERG-induced EMT transcript signature was exemplified by suppressed expression of E-cadherin and keratins 5, 8, 14 and 18; elevated expression of N-cadherin, N-cadherin 2 and vimentin, and of the EMT transcriptional regulators Snail, Zeb1 and Zeb2, and lymphoid enhancer-binding factor-1 (LEF-1). In BPH-1 and RWPE-1-fERG cells, fERG expression is correlated with increased expression of integrin-linked kinase (ILK) and its downstream effectors Snail and LEF-1. Interfering RNA suppression of ERG decreased expression of ILK, Snail and LEF-1, whereas small interfering RNA suppression of ILK did not alter fERG expression. Interfering RNA suppression of ERG or ILK impaired fERG-PrEC Matrigel invasion. Treating fERG-BPH-1 cells with the small molecule ILK inhibitor, QLT-0267, resulted in dose-dependent suppression of Snail and LEF-1 expression, Matrigel invasion and reversion of anchorage-independent growth. These results suggest that ILK is a therapeutically targetable mediator of ERG-induced EMT and transformation in PCa.