997 resultados para TanDEM-X
Resumo:
We present a detailed study of a 3+2+1] cascade cyclisation of vinylcyclopropanes (VCP) catalysed by a bromenium species (Brd+?Xd-) generated in situ, which results in the synthesis of chiral bicyclic amidines in a tandem one-pot operation. The formation of amidines involves the ring-opening of VCPs with Br?X, followed by a Ritter-type reaction with chloramine-T and a tandem cyclisation. The reaction has been further extended to vinylcyclobutane systems and involves a 4+2+1] cascade cyclisation with the same reagents. The versatility of the methodology has been demonstrated by careful choice of VCPs and VCBs to yield bicyclo4.3.0]-, -4.3.1]- and -4.4.0]amidines in enantiomerically pure form. On the basis of the experimental observations and DFT calculations, a reasonable mechanism has been put forth to account for the formation of the products and the observed stereoselectivity. We propose the existence of a p-stabilised homoallylic carbocation at the cyclopropane carbon as the reason for high stereoselectivity. DFT studies at B3LYP/6-311+G** and M06-2X/6-31+G* levels of theory in gas-phase calculations suggest the ring-opening of VCP is initiated at the p-complex stage (between the double bond and Br?X). This can be clearly perceived from the solution-phase (acetonitrile) calculations using the polarisable continuum model (PCM) solvation model, from which the extent of the ring opening of VCP was found to be noticeably high. Studies also show that the formation of zero-bridge bicyclic amidines is favoured over other bridged bicyclic amidines. The energetics of competing reaction pathways is compared to explain the product selectivity.
Resumo:
Novas metodologias de análise molecular voltadas para estudos populacionais, clínicos, evolutivos, da biodiversidade e identificação forense foram desenvolvidas com base em marcadores microssátelites ou STR Short Tandem Repeats. Os marcadores STR, que estão amplamente espalhados nos genomas e se caracterizam por apresentar alto grau de polimorfismo, podem ser analisados a partir da amplificação por PCR (Reação em Cadeia da polimerase). A análise foi facilitada a partir do desenvolvimento de sistemas de amplificação simultânea de múltiplos STR (multiplex STR) e com a detecção automatizada dos produtos de amplificação marcados por fluorescência. Recentemente, o uso de marcadores STR do cromossomo X (X-STR) tornou-se significativo na prática forense. Devido ao seu modo de transmissão, os X-STR são úteis em situações particulares de investigação de relações de parentesco, apresentando vantagens sobre o uso de STR autossômicos. Este estudo teve como principal objetivo o desenvolvimento e validação de sistema multiplex, denominado LDD (X-STR) Decaplex, capaz de amplificar dez loci X-STR (DXS7133, DXS7424, DXS8378, DXS6807, DXS7132, DXS10074, DXS7423, DXS8377, GATA172D05 e DXS10101) para aplicação em genética populacional, identificação e análises forenses. Utilizando o LDD (X-STR) Decaplex 170 indivíduos autodenominados afrodescendentes, não aparentados geneticamente, foram genotipados. As freqüências alélicas e genotípicas não apresentaram desvio do equilíbrio de Hardy-Weinberg e estão em concordância com aquelas observadas em outros estudos. Os haplótipos observados foram únicos em indivíduos de amostra masculina. A análise de desequilíbrio de ligação não revelou associação entre os marcadores X-STR. A diversidade genética foi elevada, variando entre 0,6218 para o locus DXS7133 a 0,9327 para o locus DXS8377. Os parâmetros de Probabilidade de Vinculação (PV), Índice de Vinculação (IV), Poder de Exclusão (PE), Poder de Discriminação e Razão de Verossimilhança foram também elevados, demonstraram que os dez X-STRs são altamente polimórficos e discriminativos na população estudada. A concentração mínima de DNA para a amplificação dos loci do LDD (X-STR) Decaplex é de 0,5 ng e verificamos que amplificação por PCR pode ser afetada quando são adicionados mais de 5 ng de DNA nas reações. Os percentuais de bandas stutter foram elevados para os loci DXS7132 e DXS8377. No teste de reprodutibilidade observamos consistência entre as tipagem de diferentes amostras biológicas, incluindo as de restos mortais. No teste de mistura a proporção limite em que observamos a coexistência de duas espécies biológicas foi de 2,5:1ng (feminino-masculino). Os resultados evidenciaram que os loci do LDD (X-STR) Decaplex são altamente informativos, consistindo, em conjunto, uma ferramenta importante em estudos de identificação humana e de relações de parentesco.
Resumo:
O retardo mental (RM) representa um problema de saúde pública mundial ainda negligenciado no Brasil e, em especial nas regiões mais pobres como o Nordeste. A síndrome do X frágil (SXF) é uma das formas mais estudadas de RM hereditário em seres humanos. Esta doença monogênica, de herança ligada ao X dominante, é decorrente de uma mutação no exon 1 do gene FMR1, localizado na região Xq27.3. A mutação no FMR1 se caracteriza pelo aumento de repetições de trinucleotídios CGG em tandem na região 5 UTR desse gene, sendo a expansão dessas trincas o principal evento mutacional responsável pela SXF. De maneira geral, os fenótipos cognitivos de indivíduos do sexo masculino com a síndrome incluem deficiência intelectual de moderada à grave. No presente trabalho, realizamos um estudo transversal da SXF em indivíduos portadores de retardo mental de causa desconhecida, engajados em Programas de Educação Especial e em instituições psiquiátricas de São Luís-MA, rastreando amplificações de sequências trinucleotídicas no gene FMR1. A amostra foi composta por 238 indivíduos do sexo masculino, não aparentados, na faixa etária de 4 a 60 anos (média = 21 9 anos). O DNA dos participantes foi obtido a partir de 5 mL de sangue coletados em tubos com anti-coagulante EDTA e a análise molecular da região gênica de interesse foi realizada através da reação em cadeia da polimerase, utilizando-se três primers. Dentre os indivíduos triados quanto à presença de mutações no gene FMR1, apenas um apresentou um resultado inconclusivo e 2 (0,84%) foram positivos para a SXF, sendo que um deles (3503) apresentou mais de 200 repetições CGG no locus FRAXA e o outro indivíduo (3660) apresentou uma deleção de ~197 pb envolvendo parte das repetições CGG e uma região proximal às repetições CGG. Ambos possuíam história familiar de RM ligado ao X. No indivíduo 3503 observamos as seguintes características clínicas: temperamento dócil, orelhas grandes, mandíbula proeminente e flacidez ligamentar. O indivíduo 3660 apresentava hiperatividade, contato pobre com os olhos, orelhas grandes, mandíbula proeminente, pectus excavatum, macroorquidismo e pouca comunicação. O esclarecimento sobre a doença oferecido às famílias de ambos contribuiu sobremaneira para o entendimento da condição, do prognóstico e dos riscos de recorrência. A prevalência da SXF em nossa amostra, 0,84%, embora relativamente baixa, encontra-se na faixa de incidência de casos diagnosticados em outras populações que, em sua maioria, relatam incidências variando de 0 a 3%. Em parte, atribuímos o percentual encontrado aos critérios de inclusão utilizados em nosso estudo. Concluímos que o protocolo de triagem molecular utilizado em nosso estudo se mostrou eficiente e adequado para a realidade do Maranhão, podendo constituir uma ferramenta auxiliar a ser aplicada na avaliação de rotina dos portadores de RM, com grandes benefícios para o Estado.
Resumo:
In this work, a novel light source of tandem InGaAsP/InGaAsP multiple quantum well electroabsoption modulator( EAM ) monolithically integrated with distributed feedback laser is fabricated by ultra-low-pressure ( 22 x 10(2) Pa ) selective area growth metal-organic chemical vapor diposition technique. Superior device performances have been obtained, such as low threshold current of 19 mA, output light power of 4.5 mW, and over 20 dB extinction ratio at 5 V applied voltage when coupled into a single mode fiber. Over 10 GHz 3dB bandwidth in EAM part is developed with a driving voltage of 2 V. Using this sinusoidal voltage driven integrated device, 10 GHz repetition rate pulse with an actual width of 13.7 ps without any compression elements is obtained due to the gate operation effect of tandem EAMs.
Resumo:
IEECAS SKLLQG
Resumo:
The electrospray ionization ion trap multiple-stage tandem mass spectrometry (ESI-MSn) and electrospray ionization Fourier transform ion cyclotron resonance multiple-stage tandem mass spectrometry (ESI-FT-ICR-MSn) have been applied successfully to the direct investigation of a number of dibenzocyclooctadiene lignan constituents from the methanol extracts of the Fructus Schisandrae in the positive ion mode. The detailed structural characterization of the same skeleton and different peripheral substituents had been studied and the precise elemental compositions of ions at high mass resolution had been obtained. So the fragmentation mechanisms could be clarified.
Resumo:
The principal components, isoflavonoids and astragalosides, in the extract of Radix Astragali were detected by a high-performance liquid chromatography Couple to electrospray ionization ion trap multiple-stage tandem mass spectrometry (HPLC-ESI-IT-MSn) method. By comparing the retention time (t(R)) of HPLC, the ESI-MSn data and the structures of analyzed Compounds with the data of reference compounds and in the literature, 17 isoflavonoids and 12 astragalosides have been identified or tentatively deduced. By Virtue of the extracted ion chromatogram (EIC) mode, simultaneous determination of isoflavonoids and astragalosides could be achieved when the different components formed overlapped peaks. And this method has been utilized to analyze the constituents in extracts of Radix Astragali from Helong City and of different growth years. Then the antioxidant activity of different samples has been Successfully investigated by HPLC-ESI-MS method in multiple selected ion monitoring(MIM) mode, applying the spin trapping technology, and the Ferric Reducing Antioxidant Power (FRAP) assay was applied to support the result.
Resumo:
A reversed-phase high-performance liquid chromatography-diode array detector-electrospray ionization multiple-stage tandem mass spectrometry (RP-HPLC-DAD-ESl-MSn) method has been developed for the detection and analysis of lignan constituents in the methanol extract from the fruits of Schisandra chinensis (Turcz.) Baill. RP-HPLC-DAD-ESI-MSn and electrospray ionization Fourier transform ion cyclotron resonance multiple-stage tandem mass spectrometry (ESI-FT-TCR-MSn) have been applied to investigate the characteristic product ions of four lignan reference compounds. Then, the logical fragmentation pathways of the lignans have been proposed. By comparing the retention time (t(R)) of HPLC, the ESI-MSn data and the structures of analyzed compounds with the data of reference compounds and in the literature, 11 peaks in HPLC have been unambiguously identified and another 5 peaks have been tentatively identified or deduced. Also, in the present paper, the extracted ion chromatograms (EIC) have been used to analyze the lignan isomers. The experimental results demonstrate that RP-HPLC-DAD-ESI-MSn is a specific and useful method for the identification of the lignan constituents and their isomers.
Resumo:
Four isomers of steroidal saponins were differentiated using multiple-stage tandem mass spectrometry combined with electrospray ionization (ESI-MSn). With the addition of lithium salt, the [M+Li](+) ions of saponins were observed in the ESI spectra. MSn spectra of these [M+Li](+) ions provided detailed structural information and allowed differentiation of the four isomeric saponins. The cross-ring cleavage ions from the saccharide chains of the saponins could be used as diagnostic ions for information concerning the linkage of the sugar moieties of the saponins. The masses of the X, A, Y and C type fragment ions formed from [M+Li](+) ions of the isomeric saponins provided information defining the methyl group locations.
Resumo:
A sensitive method for the determination of 30 kinds of free fatty acids (FFAs, C-1-C-30) with 1-[2-(p-toluenesulfonate)-ethyl]-2-phenylimidazole-[4,5-f] 9,10-phenan- threne (TSPP) as labeling reagent and using high performance liquid chromatography with fluorescence detection and identification by online postcolumn mass spectrometry with atmospheric pressure chemical ionization (APCI) source in positive-ion mode (HPLC/MS/APCI) has been developed. TSPP could easily and quickly label FFAs in the presence of K2CO3 catalyst at 90 degrees C for 30 min in N,N-dimethylformamide (DMF) solvent, and maximal labeling yields close to 100% were observed with a 5-fold excess of molar reagent. Derivatives were stable enough to be efficiently analyzed by high performance liquid chromatography. TSPP was introduced into fatty acid molecules and effectively augmented MS ionization of fatty acid derivatives and led to regular MS and MS/MS information. The collision induced cleavage of protonated molecular ions formed specific fragment ions at m/z [MH](+)(molecular ion), m/z [M'+CH2CH2](+)(M' was molecular mass of the corresponding FFA) and m/z 295.0 (the, mass of protonated molecular core structure of TSPP). Fatty acid derivatives were separated on a reversed-phase Eclipse XDB-C-8 column (4.6 x 150 mm, 5 mu m, Agilent) with a good baseline resolution in combination with a gradient elution. Linear ranges of 30 FFAs are 2.441 x 10(-3) to 20 mu mol/L, detection limits are 3.24 similar to 36.97 fmol (injection volume 10 mu L, at a signal-to-noise ratio of 3, S/N 3:1). The mean interday precision ranged from 93.4 to 106.2% with the largest mean coefficients of variation (R.S.D.) < 7,5%. The mean intraday precision for all standards was < 6.4% of the expected concentration. Excellent linear responses were observed with correlation coefficients of > 0.9991. Good compositional data could be obtained from the analysis of extracted fatty acids from as little as 200 mg of bryophyte plant samples.Therefore, the facile TSPP derivatization coupled with HPLC/MS/APCI analysis allowed the development of a highly sensitive method for the quantitation of trace levels of short and long chain fatty acids from biological and natural environmental samples.
Resumo:
Ketamine is widely used in medicine in combination with several benzodiazepines including midazolam. The objectives of this study were to develop a novel HPLC-MS/SRM method capable of quantifying ketamine and norketamine using an isotopic dilution strategy in biological matrices and study the formation of norketamine, the principal metabolite of ketamine with and without the presence of midazolam, a well-known CYP3A substrate. The chromatographic separation was achieved using a Thermo Betasil Phenyl 100 x 2 mm column combined with an isocratic mobile phase composed of acetonitrile, methanol, water and formic acid (60:20:20:0.4) at a flow rate of 300 μL/min. The mass spectrometer was operating in selected reaction monitoring mode and the analytical range was set at 0.05–50 μM. The precision (%CV) and accuracy (%NOM) observed were ranging from 3.9–7.8 and 95.9.2–111.1% respectively. The initial rate of formation of norketamine was determined using various ketamine concentration and Km values of 18.4 μM, 13.8 μM and 30.8 μM for rat, dog and human liver S9 fractions were observed respectively. The metabolic stability of ketamine on liver S9 fractions was significantly higher in human (T1/2 = 159.4 min) compared with rat (T1/2 = 12.6 min) and dog (T1/2 = 7.3 min) liver S9 fractions. Moreover significantly lower IC50 and Ki values observed in human compared with rat and dog liver S9 fractions. Experiments with cDNA expressed CYP3A enzymes showed the formation of norketamine is mediated by CYP3A but results suggest an important contribution from others isoenzymes, most likely CYP2C particularly in rat.
Resumo:
There has been recent interest in the use of X-chromosomal loci for forensic and relatedness testing casework, with many authors developing new X-linked short tandem repeat (STR) loci suitable for forensic use. Here we present formulae for two key quantities in paternity testing, the average probability of exclusion and the paternity index, which are suitable for Xchromosomal loci in the presence of population substructure.
Resumo:
A rapid, sensitive and specific LC-MS/MS method was developed and validated for quantifying chlordesmethyldiazepam (CDDZ or delorazepam), the active metabolite of cloxazolam, in human plasma. In the analytical assay, bromazepam (internal standard) and CDDZ were extracted using a liquid-liquid extraction (diethyl-ether/hexane, 80/20, v/v) procedure. The LC-MS/MS method on a RP-C18 column had an overall run time of 5.0 min and was linear (1/x weighted) over the range 0.5-50 ng/mL (R > 0.999). The between-run precision was 8.0% (1.5 ng/mL), 7.6% (9 ng/mL), 7.4% (40 ng/mL), and 10.9% at the low limit of quantification-LLOQ (0.500 ng/mL). The between-run accuracies were 0.1, -1.5, -2.7 and 8.7% for the above mentioned concentrations, respectively. All current bioanalytical method validation requirements (FDA and ANVISA) were achieved and it was applied to the bioequivalence study (Cloxazolam-test, Eurofarma Lab. Ltda and Olcadil (R)-reference, Novartis Biociencias S/A). The relative bioavailability between both formulations was assessed by calculating individual test/reference ratios for Cmax, AUClast and AUCO-inf. The pharmacokinetic profiles indicated bioequivalence since all ratios were as proposed by FDA and ANVISA. Copyright (C) 2009 John Wiley & Sons, Ltd.