987 resultados para Tamanho de gotas


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this work was to evaluate the effect of the addition of different surfactants in physical and chemical properties of spray solutions, droplets spectra and drift potential on agricultural spraying. The surfactants and concentrations (v v-1) were: Haiten (0.1%), Antideriva and Intec (0.05% and 0.1%). The following characteristics were analyzed: surface tension, viscosity, density and electric conductivity. The droplet size spectrum was determined by a laser particle analyzer (Mastersizer S®, version 2.15) including measurements of volume medium diameter (VMD), the percent of droplets below 50 and 100 μm (V50 e V100) and index span. In order to estimate the drift potential, a series of wind tunnel tests were performed with a Teejet XR 8003 flat fan nozzle at 200 kPa (medium droplets) used to apply the spray solutions containing water, the adjuvants and a food color dye (Brilliant blue FD & C no 1) at 0,6% m v-1. The drift was collected on nylon strips transversally fixed along the tunnel at different distances from the nozzle and different high from the bottom part of the tunnel. Drift deposits were evaluated by spectrophotometry. The results showed that the addition of adjuvants changed physical and chemical properties of spray solutions in different magnitudes according to the surfactant. Surfactants changed the droplet spectrum and drift potential, indicating that higher VMD and smaller V100 induced higher percentage of drift.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As pontas de pulverização são responsáveis pela formação das gotas, e cada ponta apresenta características próprias relacionadas ao espectro de gotas e perfil de deposição, específicas para determinados alvos. Este trabalho teve o objetivo de caracterizar o diâmetro e a uniformidade das gotas e o perfil de distribuição volumétrica das pontas de pulverização AI 110015 e TTI 110015, bem como seu efeito sobre a mortalidade de corda-de-viola, com herbicida pré-emergente, associado ou não a adjuvantes. Avaliou-se o número de plantas emergidas e os pesos secos da parte aérea e radicular das plantas. Os perfis de distribuição volumétrica para a altura de 40 cm foram avaliados em mesa de deposição. A partir dos perfis de distribuição, simulou-se o padrão de deposição ao longo da barra de pulverização. O espectro do diâmetro de gotas foi determinado em analisador de tamanho de partículas por difração de luz laser . O herbicida diuron + hexazinona foi eficiente no controle em préemergência de corda-de-viola, podendo ser utilizado polimetil siloxano organomodificado ou óleo mineral como adjuvantes, associados às pontas de pulverização AI 110015 ou TTI 110015. O uso de adjuvantes proporcionou aumento no diâmetro mediano volumétrico e redução na porcentagem de gotas com diâmetro inferior a 100 µm. O espaçamento sugerido entre os bicos na barra de pulverização foi de 70 cm para o modelo AI 110015 e 80 cm para o modelo TTI 110015.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objetivou-se neste trabalho avaliar a distribuição volumétrica e o espectro de gotas das pontas de pulverização de baixa deriva TTI110015, AI110015 e AVI11001 sob diferentes condições operacionais. A distribuição volumétrica foi determinada em bancada de ensaios padronizada analisando o coeficiente de variação (CV%) de uma barra simulada em computador, utilizando pressões de 200, 300 e 400 kPa, altura de 30, 40 e 50 cm em relação à bancada e espaçamento entre pontas de 40 a 100 cm. O espectro de gotas foi produzido utilizando-se apenas água como calda em um analisador de partículas em meio aquoso, nas pressões de 200, 300 e 400 kPa. Foram avaliados o DMV, a porcentagem de gotas com diâmetro inferior a 100 µm (%100 µm) e a amplitude relativa (AR). As pontas proporcionaram perfil descontínuo nas pressões de 300 e 400 kPa e uniforme a 200 kPa. Na pressão de 200 kPa, as pontas foram adequadas apenas para aplicação em faixa, e a 300 e 400 kPa, apenas para área total. Ocorreu menor CV (abaixo de 7%) com a maior pressão de trabalho e menor espaçamento entre pontas. À medida que se aumentou a pressão de trabalho, reduziu-se o DMV. As pontas TTI110015 e AI110015 em todas as pressões e a ponta AVI11001 na pressão de 200 kPa produziram gotas extremamente grossas e gotas grossas nas pressões de 300 e 400 kPa apenas para a ponta AVI11001. As pontas proporcionaram baixos valores de amplitude relativa (AR) e gotas de tamanho uniforme, bem como produziram baixa porcentagem de gotas menores que 100 µm, principalmente TTI110015 e AI110015, com menor risco de deriva.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed to verify the influence of adjuvants on the droplet spectrum of an air induction nozzle. The experiment used nine spray solutions, one including only water and eight containing adjuvants: Nimbus® (mineral oil), Óleo vegetal Nortox (vegetal oil), Li-700® (a mixture of lecithin and propionic acid), Agral® (nonyl phenoxy poly ethanol), In-Tec® (nonyl phenol ethoxylate), Antideriva (nonyl phenol ethoxylate), Silwet® L-77 Ag (copolymer polyester and silicon) and TA 35 (sodium lauryl ether sulfate). A flat fan air induction nozzle Hypro® Guardian Air 110 03 was used for the droplet spectrum evaluation. The study was conducted at the Laboratory for Particle Size Analysis (Lapar), at FCAV/UNESP, Jaboticabal/SP - Brazil. The determination of the droplet spectrum characteristics (Volume Median Diameter/VMD, percentage of droplets smaller than 100 micrometers and span) was carried out by a particle size analyzer by laser diffraction Mastersizer S (Malvern Instruments). For statistical analysis the mean values were compared using Confidence Interval at 95% (CI 95%). The results showed that for the Hypro® GA air induction nozzle the oil based adjuvants (Óleo Vegetal Nortox e Nimbus®) increased the VMD. The percentage of droplets smaller than 100 micrometers was lower for the Agral®, Antideriva, In-Tec® e TA 35, in comparison with the Óleo Vegetal Nortox and Li-700®. The span was higher for the oil based adjuvants (Óleo Vegetal Nortox e Nimbus®) and lower for the TA 35 (sodium lauryl ether sulfate), showing that the TA 35 adjuvant has a potential to improve the quality of the droplet spectrum of the Hypro® GA 11003 nozzle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente trabalho tem por objetivo investigar a microbiota de canais radiculares que apresentem lesão perirradicular e relacionar o perfil microbiano detectado com a área/volume destas lesões visualizadas por radiografias periapicais e tomografias computadorizadas tipo cone-beam. Foram selecionados 19 dentes com infecção endodôntica primária. As amostras microbiológicas foram coletadas dos canais com o auxílio de limas tipo Hedströen e cones de papel absorvente estéril. A técnica do Checkerboard DNA-DNA hybridization foi utilizada para detecção de até 79 espécies bacterianas em cada amostra, utilizando sondas de DNA específicas. Os dados microbiológicos foram expressos em percentagem média (prevalência), proporção e nível médio de cada espécie em cada amostra. Os testes t independente e de correlação de Pearson foram usados para correlacionar a contagem das bactérias testadas com os dados clínicos (p≤ 0,05). Foi encontrada uma média de 17 espécies por amostra. E. brachy (70%), S. pneumonia (67,5%), P. oris (67,5%), E. faecium (65%), N. gonorrhoeae (62,5%), K. pneumoniae (62,5%), P. melaninogenica (62,5%), P. nigrescens (62,5%) e P. micra (62,5%) foram as espécies mais prevalentes, e as espécies encontradas em níveis médios mais altos foram P. oris (7,5 x 105), E. brachy (7,3 x 105), E. faecium (7,2 x 105), K. pneumoniae (7,0 x 105), N. gonorrhoeae (6,8 x 105), S. epidermidis (6,5 x 105) e H. pylori (6,5 x 105). Houve correlação positiva entre as lesões periapicais de maior área e contagens significativamente mais altas da carga bacteriana total e de bactérias Gram-negativas (p<0,05). Baseado nos resultados obtidos é possível concluir que a microbiota presente em dentes com periodontite apical primária possui perfil misto e complexo, e que uma maior tamanho de lesão perirradicular pode estar associada a contagem elevada espécie totais e bactérias Gram-negativas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neste trabalho é apresentado um estudo para a determinação do tamanho ótimo da malha de elementos, utilizando redes neurais artificiais, para o cálculo da intensidade útil. A ideia principal é treinar as redes de modo a possibilitar a aprendizagem e o reconhecimento do melhor tamanho para diversas áreas superficiais em fontes sonoras com geometria plana. A vantagem de se utilizar redes neurais artificiais deve-se ao fato de apresentarem um único tamanho para a obtenção da intensidade útil, consequentemente, uma redução significativa de tempo computacional quando comparado com o tempo de cálculo de uma malha bem refinada. Ensaios numéricos com placas planas - geometria separável que permite uma solução analítica - são utilizados para se realizar comparações. É apresentado um estudo comparativo entre o tempo computacional gasto para a obtenção da intensidade útil e o mesmo com a malha otimizada via redes neurais artificiais. Também é apresentada uma comparação do nível de potência sonora mediante solução numérica, a fim de validar os resultados apresentados pelas redes neurais.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Um código computacional para escoamentos bifásicos incorporando metodologia híbrida entre oMétodo dos Elementos Finitos e a descrição Lagrangeana-Euleriana Arbitrária do movimento é usado para simular a dinâmica de um jato transversal de gotas na zona primária de quebra. Os corpos dispersos são descritos por meio de um método do tipo front-tracking que produz interfaces de espessura zero através de malhas formadas pela união de elementos adjacentes em ambas as fases e de técnicas de refinamento adaptativo. Condições de contorno periódicas são implementadas de modo variacionalmente consistente para todos os campos envolvidos nas simulações apresentadas e uma versão modificada do campo de pressão é adicionada à formulação do tipo um-fluido usada na equação da quantidade de movimento linear. Simulações numéricas diretas em três dimensões são executadas para diferentes configurações de líquidos imiscí veis compatíveis com resultados experimentais encontrados na literatura. Análises da hidrodinâmica do jato transversal de gotas nessas configurações considerando trajetórias, variação de formato de gota, espectro de pequenas perturbações, além de aspectos complementares relativos à qualidade de malha são apresentados e discutidos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este trabalho avaliou o programa Gotas, desenvolvido pela Embrapa Informática Agropecuária e Embrapa Meio Ambiente, para comparação de resultados de deposição de pulverização aérea, em diferentes situações de temperatura e umidade relativa. Constatou-se que o programa permite estimativas fidedignas de parâmetros imprescindíveis à tomada de decisão sobre a calibração da pulverização. As pulverizações com aeronaves realizadas em condições de temperatura 36 ºC e 25% de umidade relativa foram totalmente inadequadas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de Mestrado, Biologia Marinha, Especialização em Pescas e Aquacultura, Faculdade de Ciências do Mar e do Ambiente, Universidade do Algarve, 2008