951 resultados para TRANSVAGINAL COLOR DOPPLER


Relevância:

100.00% 100.00%

Publicador:

Resumo:

La placenta ácreta es la implantación anómala de la placenta en la pared uterina. Se presenta en 0.9% de todos los embarazos; actualmente es una de las causas más importantes de morbimortalidad materna. Ecografía 2D y Doppler placentario son métodos diagnósticos de primera y segunda línea. Objetivo: Evaluar la utilidad diagnóstica de ecográfica 2D y Doppler color Placentario para diagnóstico de acretismo placentario en gestantes con factores de riesgo comparándolos con diagnóstico clínico e histopatológico; y determinar incidencia de acretismo placentario en población asistente a Clínica Universitaria Colombia. Metodología: Estudio de evaluación de tecnología diagnóstica. Entre Agosto a Noviembre de 2010 se incluyeron 53 gestantes entre 24 y 40 semanas de gestación con factores de riesgo para acretismo placentario. El desempeño diagnóstico de las pruebas se determinará por sensibilidad, especificidad, valores predictivos positivo y negativo. Las características demográficas de las pacientes y resultados neonatales se analizaron mediante proporción, media y rango. Resultados: Se determinó incidencia de acretismo placentario en 4,54% de las gestantes con presencia de factores de riesgo para esta patología. Los datos hasta el momento no nos permiten calcular valores de desempeño diagnóstico. Un caso termino en histerectomía por acretismo placentario. Conclusión: Con los datos preliminares registramos una incidencia de acretismo placentario de 1 en 22 pacientes. Revisión de literatura sustenta la necesidad de realización diagnostica prenatal que impacte en la morbimortalidad materna y fetal, haciendo necesario la evaluación diagnostica valida de herramientas como el Eco 2D y Doppler color en población a riesgo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La placenta ácreta es la implantación anómala de la placenta en la pared uterina. Se presenta en 0.9% de todos los embarazos; actualmente es una de las causas más importantes de morbimortalidad materna. Ecografía 2D y Doppler placentario son métodos diagnósticos de primera y segunda línea. Objetivo: Evaluar la utilidad diagnóstica de ecográfica 2D y Doppler color Placentario para diagnóstico de acretismo placentario en gestantes con factores de riesgo comparándolos con diagnóstico clínico e histopatológico; y determinar incidencia de acretismo placentario en población asistente a Clínica Universitaria Colombia. Metodología: Estudio de evaluación de tecnología diagnóstica. Entre Agosto a octubre 2011 se incluyeron 137 gestantes entre 24 y 40 semanas de gestación con factores de riesgo para acretismo placentario. El desempeño diagnóstico de las pruebas se determinará por sensibilidad, especificidad, valores predictivos positivo y negativo. Las características demográficas de las pacientes y resultados neonatales se analizaron mediante proporción, media y rango. Resultados: En un grupo de 137 pacientes con factores de riesgo de acretismo placentario analizadas se obtuvo el dato de 119 en cuanto a la finalización del embarazo. Se observaron 4 casos con diagnóstico clínico e histopatológico de acretismo placentario, evidenciando una prevalencia del 2,9%. La ecografía 2D y Doppler en la detección de acretismo placentario con un nivel de confianza del 95%, presentaron sensibilidad del 100% (IC95% 87,5-100) y especificidad de 100% (IC95% 99,6-100). Conclusión: Con los datos analizados registramos una incidencia de acretismo placentario de 4 en 132 pacientes. Revisión de literatura sustenta la necesidad de realización diagnostica prenatal que impacte en la morbimortalidad materna y fetal, haciendo necesario la evaluación diagnostica valida de herramientas como el Eco 2D y Doppler color en población a riesgo.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background Accurate diagnosis of portal vein (PV) stenosis by real-time and color Doppler US (CD-US) after segmental liver transplantation in children can decrease morbidity by avoiding unnecessary biopsy, PV hypertension, thrombosis and loss of the graft. Objective To evaluate CD-US parameters for the prediction of PV stenosis after segmental liver transplantation in children. Materials and methods We retrospectively reviewed 61 CD-US examinations measuring the diameter at the PV anastomosis, velocities at the anastomosis (PV1) and in the segment proximal to the anastomosis (PV2), and the PV1/PV2 velocity ratio. The study group comprised patients with stenosis confirmed by angiography and the control group comprised patients with a good clinical outcome. Results PV stenosis was seen in 12 CD-US examinations. The mean PV diameter was smaller in the study group (2.6 mm versus 5.7 mm) and a PV diameter of < 3.5 mm was highly predictive of stenosis (sensitivity 100%, specificity 91.8%). Conclusion A PV diameter of < 3.5 mm is a highly predictive CD-US parameter for the detection of hemodynamically significant stenosis on angiography.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a reprodutibilidade interobservador dos índices de vascularização do Doppler de amplitude tridimensional (Doppler de amplitude 3D) no primeiro trimestre de gestação. MATERIAIS E MÉTODOS: Realizou-se estudo de reprodutibilidade com 32 gestantes normais entre 7 e 10 semanas e 6 dias. Para o cálculo do volume tridimensional dos embriões utilizou-se o método VOCAL (Virtual Organ Computer-aided AnaLysis) com ângulo de rotação de 12°. Em seguida obtiveram-se, automaticamente, os três índices vasculares do Doppler de amplitude 3D: índice de vascularização (VI), índice de fluxo (FI) e índice de vascularização e fluxo (VFI). Para o cálculo da variabilidade interobservador, um examinador realizou uma segunda medida dos 32 embriões e um segundo examinador realizou uma terceira medida dos mesmos volumes, ambos desconhecendo os resultados do outro. Utilizaram-se, para análise estatística, o coeficiente de correlação intraclasse (CCI) e gráficos de Bland-Altman. RESULTADOS: Observou-se boa reprodutibilidade interobservador dos três índices vasculares. O VI apresentou CCI = 0,9 e média da diferença = -1,1; o FI apresentou CCI = 0,9 e média da diferença = -0,5; e o VFI apresentou CCI = 0,9 e média da diferença = -1,1. CONCLUSÃO: Os índices vasculares do Doppler de amplitude 3D do embrião no primeiro trimestre de gestação foram altamente reprodutíveis, em especial o FI.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJETIVO: investigar a presença e resultados de malformações vasculares uterinas (MAVU) após doença trofoblástica gestacional (DTG). MÉTODOS: estudo retrospectivo com inclusão de casos diagnosticados entre 1987 e 2004; 2764 pacientes após DTG foram acompanhadas anualmente com ultra-sonografia transvaginal e Doppler colorido no Centro de Neoplasia Trofoblástica Gestacional da Santa Casa da Misericórdia (Rio de Janeiro, RJ, Brasil). Sete pacientes tiveram diagnóstico final de MAVU baseado em análise ultra-sonográfica - índice de pulsatilidade (IP), índice de resistência (IR) e velocidade sistólica máxima (VSM) - e achados de imagens de ressonância nuclear magnética (RNM). Dosagens negativas de beta-hCG foram decisivas para estabelecer o diagnóstico diferencial com DTG recidivante. RESULTADOS: a incidência de MAVU após DTG foi 0,2% (7/2764). Achados ultra-sonográficos de MAVU: IP médio de 0,44±0,058 (extremos: 0,38-0,52); IR médio de 0,36±0,072 (extremos: 0,29-0,50); VSM média de 64,6±23,99 cm/s (extremos: 37-96). A imagem de RNM revelou útero aumentado, miométrio heterogêneo, espaços vasculares tortuosos e vasos parametriais com ectasia. A apresentação clínica mais comum foi hemorragia transvaginal, presente em 52,7% (4/7) dos casos. Tratamento farmacológico com 150 mg de acetato de medroxiprogesterona foi empregado para controlar a hemorragia, após a estabilização hemodinâmica. Permanecem as pacientes em seguimento, assintomáticas até hoje. Duas pacientes engravidaram com MAVU, com gestações e partos exitosos. CONCLUSÃO: presente sangramento transvaginal em pacientes com beta-hCG negativo e história de DTG, deve-se considerar a possibilidade de MAVU e solicitar avaliação ultra-sonográfica com dopplervelocimetria. O tratamento conservador é a melhor opção na maioria dos casos de MAVU pós-DTG.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objetivo: Avaliar o efeito do tartarato de brimonidina a 0,2% tópico, instilado de 12/12 horas, na circulação retrobulbar em pacientes portadores de glaucoma. Métodos: Foram estudados os 2 olhos de 16 pacientes portadores de glaucoma primário de ângulo aberto e glaucoma crônico de ângulo estreito com iridotomia. Usando o Doppler colorido foram avaliados: velocidade sistólica máxima, velocidade diastólica final e índice de resistência das artéria central da retina, artéria ciliar posterior curta temporal e artéria oftálmica. As avaliações foram feitas antes e depois do uso da brimonidina. Resultados: O tartarato de brimonidina a 0,2% aumentou significativamente a velocidade sistólica máxima (28,24 para 34,23 cm/seg) e velocidade diastólica final (6,62 para 8,10 cm/seg) no olho direito e reduziu o índice de resistência (0,75 para 0,71) no olho esquerdo da artéria oftálmica. Conclusão: O tartarato de brimonidina 0,2% 2x/dia aumentou significativamente a velocidade sistólica máxima e velocidade diastólica final e reduziu índice de resistência da artéria oftálmica de pacientes glaucomatosos. Este efeito sugere que a brimonidina pode beneficiar pacientes glaucomatosos com insuficiência vascular na cabeça do nervo óptico.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of this study was evaluate the renal hemodynamics of bitches with pyometra by means of laboratory tests, ultrasound B mode and Doppler, before and after treatment with ovariohysterectomy (OSH). This study evaluated 30 bitches with pyometra, all were subjected to OSH (moment 1) and 20 were evaluated after 7 days (moment 2). The renal perfusion, the resistivity index (RI) of the main renal artery and the interlobar arteries (cranial, middle and caudal) were statistically different between times 1 and 2 (p<0,05). There was no statistical difference for renal perfusion between the left and the right kidney at the time 1 and 2. The correlations between the IR of the main artery and the variables used to determine renal function were stablished at the time 1. For the correlated variables: urea, creatinine, proteinuria, ratio GGT/creatinine and protein/creatinine were curvilinear and positive associations with the resistivity index of the main renal artery (p<0,05), however these correlations were considered medium and weak. Comparing the RI of the main renal artery with different scores of dehydration and renal perfusion, there was statistical difference, and show increased of resistance renal in bitches with moderate reduction in renal perfusion as well as in dehydrated bitches. Were evaluated several features of renal morphology in ultrasound B mode, however, only the presence of pelvic dilatation, medullary signal and other changes as infarcts areas and diffuse hyperechoic spots in the renal cortical and medullary were statistically different from one moment to the other, most frequently at the time 2. The results of this study show that the Doppler ultrasound can identify changes of reduction in renal perfusion by color Doppler and the increasing of the resistivity index of the renal arteries in some bitches with pyometra. As well as, the ultrasound B mode, although has non-specific changes, can detect progressive renal disorders in bitches with pyometra.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pós-graduação em Ginecologia, Obstetrícia e Mastologia - FMB

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

O objetivo do trabalho foi estabelecer a relação entre a ecobiometria renal com medidas de conformação corporal como a distância atlanto-coccígea (DAC) e a altura (H) de cães adultos saudáveis, obtendo-se parâmetros de normalidade para avaliar o tamanho e volume renal, bem como estabelecer valores de referência para avaliar a perfusão sanguínea dos rins por meio do índice de resistividade (IR) e do índice de pulsatilidade (IP) do ramo principal da artéria renal. No estudo foram utilizados 22 cães adultos sem raça definida, sendo 11 machos e 11 fêmeas. Os animais foram previamente aferidos quanto a DAC e a H. Os exames ultra-sonográficos foram realizados com um aparelho HDI 4000 PHILIPS munido de um transdutor microconvexo multifreqüêncial (5-8 MHz), dispositivos Doppler Colorido e Doppler de Fluxo. Os animais foram posicionados em decúbito lateral direito ou esquerdo, de acordo com o rim a ser avaliado. Os diâmetros longitudinal (DL) e dorsoventral (DDV) dos rins foram mensurados na secção longitudinal e, o diâmetro transversal (DT) foi aferido no plano transversal. O volume (V) foi calculado automaticamente pelo software do ultra-som. Com o uso do Triplex Doppler, o IR e o IP das artérias renais direita e esquerda foram obtidos. Todos os dados foram apresentados em média ± EPM. Análises de regressão linear foram realizadas tendo o DL, DDV, DT e V como variáveis dependentes e a DAC e H como variáveis independentes. Os IR e IP dos rins direito e esquerdo foram comparados pelo teste t de Student. A DAC variou de 54-78cm para machos e 37-71cm para fêmeas e a altura variou entre 34-64 cm para os machos e 24-57cm para as fêmeas. As médias obtidas para DL, DDV, DT e V dos rins esquerdo e direito foram: 5,24±0,27cm, 3,07±0,15cm, 3,07±0,9cm, 28,01±3,4mL e 4,50±0,19cm, 2,88±0,14cm, 2,71±0,15cm, 21,27±2,6mL, respectivamente. As análises de regressão linear entre as medidas lineares e volume renal com a DAC e a H foram significativas para os interceptos e coeficientes de regressão (P<0,01). Houve diferenças estatísticas quando comparado os IR e IP entre os rins direito e esquerdo (P=0,001), sendo que as médias para IR e IP dos rins esquerdo e direito foram 0,62±0,08; 1,34±0,18 e 0,70±0,06; 1,62±0,13; respectivamente. Os dados obtidos no presente trabalho podem auxiliar na avaliação do tamanho, volume e perfusão dos rins de cães adultos.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The Doppler ultrasound allows the assessment of blood flow and the differentiate vessels according to each spectral pattern, location and organ that irrigate, helping the examinations and disease diagnosis. The main methods used are Pulsed Doppler, Color Doppler and Power Doppler. In Brazil veterinary medicine, it shows progress since 1990, but its use is limited by the equipment high cost, the need for operator experience and patient cooperation. There are studies in obstetrics and reproduction of dogs and cats, such as evaluation of the testicular vasculature, including the use of contrast material, and attempts to evaluate prostate in healthy dogs or pathological conditions (cancer and testicular torsion , orchitis and benign prostatic hyperplasia; estrous cycle monitoring, evaluation of irrigation in follicles and corpus luteum, uterus and breasts (mammary tumors) in bitches; monitoring pregnancy from the assessment of maternal, fetal and placental hemodynamics, both in dogs as in cats, and aspirations for early detection of pregnancy in dogs. However, new studies are still required, given the lack of these species, especially cats

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Doppler ultrasonography is a new technology that has been study by researchers to improve the physiologic and pathologic knowledge about reproduction. This technology is based on Doppler-shifts frequencies or ultrasonic, these frequencies can be increase or decrease according to the movements of the red cells in the vessel. Color Doppler and power Doppler are the two possibilities to use the Doppler ultrasonography. Color Doppler is based in more the one color that show the direction of the blood f low and power Doppler is based in one color that change according of the flow intensity. Doppler ultrasonography can be demonstrated with the spectral mode to verify blood flow in large vessels, because of this, it is not use in equine reproduction. Studies in equine reproduction have been doing to verify uterus blood flow in cyclic mares and to observe the vascular perfusion in mares with cists, uterine vascular perfusion post breeding and verify the affects of drugs to decrease the uterus fluid in mares with problems in uterus perfusion. The ovarian irrigation during the estrus cycle was analyze with the measurement of the principal hormones during the estrus cycle in mares, the integrity of the corpus luteus, the irrigation of the future dominant follicle and the consequences in the ovarian irrigation after luteolyse induction also were study. Nevertheless, more than the knowledge that existed about Doppler ultrasonography, new studies have been doing to improve the forms to use Doppler ultrasonography in equine reproduction

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Angiogenesis occurs as a physiologic process and is essential for normal growth and development of tissue. The ovary and its structures need adequate vascular network to ensure the availability of oxygen, nutrients, hormones, substrate, and ensure the transfer of different hormones to target cells. Then, the proper formation of this network is a limiting step for the proper functioning of this organ in general. In recent years, the local blood flow of the ovary, has been examined by color Doppler ultrasound, being able to analyze the individual follicles and the corpus luteum. This review will board the relevant aspects of the restructuring vascular ovary during the estrous cycle in female domestic large.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Study Objective: To evaluate the diagnostic accuracy of transvaginal ultrasound and office hysteroscopy in the differentiation between endometrial polyps and endometrial adenocarcinoma. Design: This is a prospective 100 women longitudinal study, 24 to 80 years, submitted to hysteroscopic polypectomy (n = 80) or surgery due to endometrial adenocarcinoma (n = 20), from january 2010 to December 2011. Clinical, ultrasonographic and hysteroscopic parameters were analyzed and compared with histopathologic find. Statistical analysis were performed utilizing the Tukey, Kruskal-Wallis, Dunn and Mann-Whitney test, with a confidence interval of 95% and p\0, 05 statiscally significant. Setting: Botucatu Medical School. Intervention: Prospective analysis of clinical, ultrasonographic and hysteroscopic parameters in patients with diagnosis suspected of endometrial polyps and adenocarcinoma of endometrium were performed. According to the diagnosis, hysteroscopic polypectomy or pan hysterectomy with lymph node sampling was realized. After the surgery and histopathological study, statistical analysis of parameters was performed and the results were compared between groups. It was Research Ethics Committee approved. Measurements and Main Results: There were no differences between age, BMI, menopause, TH use and associated diseases among groups. The main symptom of endometrial cancer was the postmenopausal bleeding, affecting 84,2% of women against 34,8% of polypectomy group. The majority of women with endometrial polyps were asymptomatic. Transvaginal ultrasonography showed no ability to differentiate cases of endometrial cancer compared with the cases of endometrial polyps, considering the presence of endometrial thickness and blood flow on color Doppler. Office hysteroscopy showed significant changes in 75% of the adenocarcinoma cases, especially the presence of diffuse hypervascularity with atypical vessels. Conclusion: Still remains an inability to establish clinical parameters and reliable ultrasound imaging to differentiate endometrial polyps and cancer of endometrium. Attention should be given to hysteroscopic exams presenting diffuse endometrial hypervascularization with architectural distortion of the vessels. The recommendation of our service remains the systematic removal of all endometrial polyps.