969 resultados para TRACE validointi
Resumo:
The eye lenses of Parma microlepis from the rocky barrens of Sydney (New South Wales, Australia) were found to contain Ba, Hg, Rb, and Sr at concentrations above the quantitative detection limits of solution-based inductively-coupled plasma-mass spectrometry (ICP-MS). Lenses were separated into the hard central nucleus and the softer surrounding cortex. Nuclei contained lower (equal for Ba) concentrations of these metals. Biochemical analysis of the protein composition of these lenses revealed differences in the ratio of gamma-crystallin to beta-crystallin in the lens nucleus and cortex. These changes were shown to be attributable both to protein degradation and changes in protein synthesis as fish age. Such changes may lead to the loss of sequestered metals from older cell layers, or change the affinity of new layers for particular trace metals. Differential binding affinities of these crystallins may, therefore, partially account for trace-metal differences observed in the lens nucleus and cortex.
Resumo:
In this study, blood serum trace elements, biochemical and hematological parameters were obtained to assess the health status of an elderly population residing in So Paulo city, SP, Brazil. Results obtained showed that more than 93% of the studied individuals presented most of the serum trace element concentrations and of the hematological and biochemical data within the reference values used in clinical laboratories. However, the percentage of elderly presenting recommended low density lipoprotein (LDL) cholesterol concentrations was low (70%). The study indicated positive correlation between the concentrations of Zn and LDL-cholesterol (p < 0.06).
Resumo:
Neutron activation analysis was applied to assess trace elements concentrations in head hair from healthy elderly people living in the Sao Paulo metropolitan area. Concentrations of As, Br, Ca, Cl, Co, Cr, Cu, Fe, K, La, Mn, Na, Sb, Se and, Zn were determined. Comparisons were made between the results obtained for dyed and non-dyed hair as well as for hair from females and males of two different age groups. The results were also compared with range values established by clinical laboratories and published data.
Resumo:
Neutron activation analysis was applied to assess trace element concentrations in brain tissues from normal (n = 21) and demented individuals (n = 21) of both genders aged more than 50 years. Concentrations of the elements Br, Fe, K, Na, Rb, Se and Zn were determined. Comparisons were made between the results obtained for the hippocampus and frontal cortex tissues, as well as, those obtained in brains of normal and demented individuals. Certified reference materials, NIST 1566b Oyster Tissue and NIST 1577b Bovine Liver were analyzed for quality of the analytical results.
Resumo:
In recent years, there has been increasing fish consumption in Brazil, largely due to the popularity of Japanese cuisine. No study, however, has previously assessed the presence of inorganic contaminants in species used in the preparation of Japanese food. In this paper, we determined total arsenic, cadmium, chromium, total mercury, and lead contents in 82 fish samples of Tuna (Thunnus thynnus), Porgy (Pagrus pagrus), Snook (Centropomus sp.), and Salmon (Salmo salar) species marketed in Sao Paulo (Brazil). Samples were mineralized in HNO(3)/H(2)O(2) for As, Cd, Cr and Pb, and in HNO(3)/H(2)SO(4)/V(2)O(5) for Hg. Inorganic contaminants were determined after the validation of the methodology using Inductively Coupled Plasma Optical Emission Spectrometry (ICP OES); and for Hg, an ICP-coupled hydride generator was used. Concentration ranges for elements analyzed in mg kg(-1) (wet base) were as follows: Total As (0.11-10.82); Cd (0.005-0.047); Cr (0.008-0.259); Pb (0.026-0.481); and total Hg (0.0077-0.9681). As and Cr levels exceeded the maximum limits allowed by the Brazilian law (1 and 0.1 mg kg(-1)) in 51.2 and 7.3% of the total samples studied, respectively. The most contaminated species were porgy (As = 95% and Cr = 10%) and tuna (As 91% and Cr = 10%). An estimation of As, Cd, Pb, and Hg weekly intake was calculated considering a 60 kg adult person and a 350 g consumption of fish per week, with As and Hg elements presenting the highest contribution on diets reaching 222% of provisional tolerable weekly intake (PTWI) for As in porgy and 41% of PTWI for Hg in tuna. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
The influence that trace concentrations Of SiO2 have on improving grain-boundary conduction via precursor scavenging using additional heat treatment at 1200 degreesC for 40 h before sintering was investigated. At a SiO2-impurity level (SIL) less than or equal to 160 ppm by weight, the grain-boundary resistivity (p(gb)) decreased to 20% of its value, while no improvement in grain-boundary conduction was found at a SIL greater than or equal to 310 ppm. The correlation between the resistance per unit grain-boundary area, p(gb), and average grain size indicated that the inhomogeneous distribution of the siliceous phase in the sample with a SIL greater than or equal to 310 ppm. hampered the scavenging reaction.
Resumo:
Trace elements can have a significant effect on the processing and properties of aluminium alloys, including sintered alloys. As little as 0.07 wt% (100 ppm) lead, tin or indium promotes sintering in an Al-Zn-Mg-Cu alloy produced from mixed elemental powders. This is a liquid phase sintering system and thin liquid films form uniformly throughout the alloy in the presence of the trace elements, but liquid pools develop in their absence. Analytical transmission electron microscopy indicates that the trace elements are confined to the interparticle and grain boundary regions. The sintering enhancement is attributed to the segregation of the microalloying addition to the liquid-vapour interface. Because the microalloying elements have a low surface tension, they lower the effective surface tension of the liquid. This reduces the wetting angle and extends the spreading of the liquid through the matrix. An improvement in sintering results. (C) 2001 Acta Materialia Inc. Published by Elsevier Science Ltd. All rights reserved.
Resumo:
Trace organic chemicals include a range of compounds which, due to a combination of their physico-chemical properties and toxicological implications, have been described as a serious threat to the biotic environment. A global treaty to regulate the manufacture and release of some of the most persistent trace chemicals has been promulgated and signed. The marine environment is an important sink for many trace chemicals, some of which accumulate in the marine food chain and in particular in marine mammals. With respect to the global distribution of trace organic chemicals, the levels of organohalogen compounds in the Southern Hemisphere are comparatively lower for a given environmental compartment and latitude compared to the Northern Hemisphere. A debate is currently evolving about the toxicity of alternative halogen substitutions such as bromine instead of chlorine and also of mixed halogen substitution. Recently a series of potentially natural bioaccumulative and persistent organohalogen chemicals have been found in marine mammals and turtles at levels in excess of those of anthropogenic trace organochlorines including PCBs and DDE. Little is known about the sources, behaviour and effects of natural trace organic chemicals. This manuscript presents an overview on the occurrence of trace organic chemicals in different compartments of the aquatic environment. Important knowledge gaps with regards to trace chemicals in the marine environment are presented. Crown Copyright (C) 2002 Published by Elsevier Science Ltd. All rights reserved.
Resumo:
We use published and new trace element data to identify element ratios which discriminate between arc magmas from the supra-subduction zone mantle wedge and those formed by direct melting of subducted crust (i.e. adakites). The clearest distinction is obtained with those element ratios which are strongly fractionated during refertilisation of the depleted mantle wedge, ultimately reflecting slab dehydration. Hence, adakites have significantly lower Pb/Nd and B/Be but higher Nb/Ta than typical arc magmas and continental crust as a whole. Although Li and Be are also overenriched in continental crust, behaviour of Li/Yb and Be/Nd is more complex and these ratios do not provide unique signatures of slab melting. Archaean tonalite-trondhjemite-granodiorites (TTGs) strongly resemble ordinary mantle wedge-derived arc magmas in terms of fluid-mobile trace element content, implying that they-did not form by slab melting but that they originated from mantle which was hydrated and enriched in elements lost from slabs during prograde dehydration. We suggest that Archaean TTGs formed by extensive fractional crystallisation from a mafic precursor. It is widely claimed that the time between the creation and subduction of oceanic lithosphere was significantly shorter in the Archaean (i.e. 20 Ma) than it is today. This difference was seen as an attractive explanation for the presumed preponderance of adakitic magmas during the first half of Earth's history. However, when we consider the effects of a higher potential mantle temperature on the thickness of oceanic crust, it follows that the mean age of oceanic lithosphere has remained virtually constant. Formation of adakites has therefore always depended on local plate geometry and not on potential mantle temperature.
Resumo:
There has been a resurgence of interest in the mean trace length estimator of Pahl for window sampling of traces. The estimator has been dealt with by Mauldon and Zhang and Einstein in recent publications. The estimator is a very useful one in that it is non-parametric. However, despite some discussion regarding the statistical distribution of the estimator, none of the recent works or the original work by Pahl provide a rigorous basis for the determination a confidence interval for the estimator or a confidence region for the estimator and the corresponding estimator of trace spatial intensity in the sampling window. This paper shows, by consideration of a simplified version of the problem but without loss of generality, that the estimator is in fact the maximum likelihood estimator (MLE) and that it can be considered essentially unbiased. As the MLE, it possesses the least variance of all estimators and confidence intervals or regions should therefore be available through application of classical ML theory. It is shown that valid confidence intervals can in fact be determined. The results of the work and the calculations of the confidence intervals are illustrated by example. (C) 2003 Elsevier Science Ltd. All rights reserved.
Resumo:
The present study aims the identification and quantification of trace elements in two types of honey samples: Orchard honey and Wild honey from mainland Portugal. Chemical elements content was assessed by Instrumental Neutron Activation Analysis (INAA). Concentrations were determinated for Ag, As, Br, Ca, Cl, Cs, Cu, Fe, K, La, Mg, Mn, Na, Rb, Sb, Sc, U, V and Zn. The nutritional values of both honey types were evaluated since this product contains some elements that are essential dietary nutrients for humans. Physical properties of the honey samples, such as electrical conductivy and pH, were assessed as well.
Resumo:
Environmental pollution continues to be an emerging study field, as there are thousands of anthropogenic compounds mixed in the environment whose possible mechanisms of toxicity and physiological outcomes are of great concern. Developing methods to access and prioritize the screening of these compounds at trace levels in order to support regulatory efforts is, therefore, very important. A methodology based on solid phase extraction followed by derivatization and gas chromatography-mass spectrometry analysis was developed for the assessment of four endocrine disrupting compounds (EDCs) in water matrices: bisphenol A, estrone, 17b-estradiol and 17a-ethinylestradiol. The study was performed, simultaneously, by two different laboratories in order to evaluate the robustness of the method and to increase the quality control over its application in routine analysis. Validation was done according to the International Conference on Harmonisation recommendations and other international guidelines with specifications for the GC-MS methodology. Matrix-induced chromatographic response enhancement was avoided by using matrix-standard calibration solutions and heteroscedasticity has been overtaken by a weighted least squares linear regression model application. Consistent evaluation of key analytical parameters such as extraction efficiency, sensitivity, specificity, linearity, limits of detection and quantification, precision, accuracy and robustness was done in accordance with standards established for acceptance. Finally, the application of the optimized method in the assessment of the selected analytes in environmental samples suggested that it is an expedite methodology for routine analysis of EDC residues in water matrices.
Resumo:
Concentrations of eleven trace elements (Al, As, Cd, Cr, Co, Hg, Mn, Ni, Pb, Se, and Si) were measured in 39 (natural and flavoured) water samples. Determinations were performed using graphite furnace electrothermetry for almost all elements (Al, As, Cd, Cr, Co, Mn, Ni, Pb, and Si). For Se determination hydride generation was used, and cold vapour generation for Hg. These techniques were coupled to atomic absorption spectrophotometry. The trace element content of still or sparkling natural waters changed from brand to brand. Significant differences between natural still and natural sparkling waters (p<0.001) were only apparent for Mn. The Mann–Whitney U-test was used to search for significant differences between flavoured and natural waters. The concentration of each element was compared with the presence of flavours, preservatives, acidifying agents, fruit juice and/or sweeteners, according to the labelled composition. It was shown that flavoured waters generally increase the trace element content. The addition of preservatives and acidifying regulators had a significant influence on Mn, Co, As and Si contents (p<0.05). Fruit juice can also be correlated to the increase of Co and As. Sweeteners did not provide any significant difference in Mn, Co, Se and Si content.
Resumo:
Traditional Real-Time Operating Systems (RTOS) are not designed to accommodate application specific requirements. They address a general case and the application must co-exist with any limitations imposed by such design. For modern real-time applications this limits the quality of services offered to the end-user. Research in this field has shown that it is possible to develop dynamic systems where adaptation is the key for success. However, adaptation requires full knowledge of the system state. To overcome this we propose a framework to gather data, and interact with the operating system, extending the traditional POSIX trace model with a partial reflective model. Such combination still preserves the trace mechanism semantics while creating a powerful platform to develop new dynamic systems, with little impact in the system and avoiding complex changes in the kernel source code.
Resumo:
Background & aims - Patients who underwent endoscopic gastrostomy (PEG) present protein-energy malnutrition, but little is known about Trace Elements (TE), Zinc (Zn), Copper (Cu), Selenium (Se), Iron (Fe), Chromium (Cr). Our aim was the evaluation of serum TE in patients who underwent PEG and its relationship with serum proteins, BMI and nature of underlying disorder. Methods - A prospective observational study was performed collecting: patient's age, gender, underlying disorder, NRS-2002, BMI, serum albumin, transferrin and TE concentration. We used ferrozine colorimetric method for Fe; Inductively Coupled Plasma-Atomic Emission Spectroscopy for Zn/Cu; Furnace Atomic Absorption Spectroscopy for Se/Cr. The patients were divided into head and neck cancer (HNC) and neurological dysphagia (ND). Results - 146 patients (89 males), 21–95 years: HNC-56; ND-90. Low BMI in 78. Low values mostly for Zn (n = 122) and Fe (n = 69), but less for Se (n = 31), Cu (n = 16), Cr (n = 7); low albumin in 77, low transferrin in 94 and 66 with both proteins low. Significant differences between the groups of underlying disease only for Zn (t140.326 = −2,642, p < 0.01) and a correlation between proteins and TE respectively albumin and Zn (r = 0.197, p = 0.025), and albumin and Fe (r = 0.415, p = 0.000). Conclusions - When gastrostomy was performed, patients display low serum TE namely Zn, but also Fe, less striking regarding others TE. It was related with prolonged fasting, whatever the underlying disease. Low proteins were associated with low TE. Teams taking care of PEG-patients should use Zn supplementation and include other TE evaluation as part of the nutritional assessment of PEG candidates.