965 resultados para THORACIC AORTA


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: It is well known that the presence of atheroma of the thoracic aorta is a risk factor for cerebrovascular events. We sought to evaluate whether the presence and the morphology of atherosclerotic plaque in the carotid artery detected by duplex ultrasonography is associated with disease in the proximal aorta visualized by transesophageal echocardiogram in patients with a cerebrovascular event. Methods: We carried out a cross-sectional prospective study including 147 consecutive patients with prior stroke or transient ischemic attack (TIA). Neurological evaluations were performed by an expert neurologist using clinical and tomographic diagnostic criteria including the definition of etiology and whether the patient suffered from stroke or TIA. Transthoracic and transesophageal echocardiograms and carotid artery duplex ultrasonography were performed by the same examiner. Patients with and without plaque in the carotid artery were compared using Student's t test or the χ2 test. Regression analysis was used to determine whether the presence of plaque in the carotid artery was predictive of the presence of plaque in the proximal aorta and to analyze the relationship between the echogenicity of carotid and aortic plaques. The significance level was set at p < 0.05. Results: All 147 patients (95 men) were included in the analysis. Patients' ages ranged from 23 to 85 years (65 ± 12.4 years). Most of the patients (58.5%) were Caucasian, while 41.5% were African-Brazilian. Arterial hypertension, diabetes and tobacco use were more frequent among patients with atherosclerotic plaque in the aorta. A normal carotid intima-media thickness halved the risk of atherosclerotic plaque in the aorta [odds ratio (OR) 0.46, 95% confidence interval (CI) 0.23-0.91; p = 0.026]. The presence of carotid plaque increased the risk of aortic plaque by 70-fold (OR 73.2, 95% CI 25.6-2,018.6; p < 0.001) in univariate analysis. The absence of atherosclerotic plaque in the carotid artery reduced the risk of plaque in the aorta to almost 0 (OR 0.014, 95% CI 0.004-0.041; p < 0.001). Considering the 86 patients with both aortic and carotid plaques, the presence of hypoechoic plaque in the carotid artery was a predictor of hypoechoic plaque in the aorta (OR 10.1, 95% CI 3.3-31.2; p < 0.001). Conclusions: The carotid artery atherosclerotic profile defined by ultrasonography is a strong predictor of the atherosclerotic profile of the proximal aorta. This should be taken into consideration before referring patients with acute cerebrovascular events for transesophageal echocardiogram. © 2013 S. Karger AG, Basel.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Pós-graduação em Bases Gerais da Cirurgia - FMB

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Fundamento: Estresse e etanol são ambos, independentemente, importantes fatores de risco cardiovascular. Objetivo: avaliar o risco cardiovascular do consumo de etanol e exposição ao estresse, isolados e em associação, em ratos machos adultos. Métodos: Os ratos foram separados em quatro grupos: controle, etanol (20% na água de beber durante seis semanas), estresse (imobilização 1h dia/5 dias por semana/ 6 semanas) e estresse/etanol. As curvas de concentração-resposta à noradrenalina - na ausência e na presença de ioimbina, L-NAME ou indometacina - ou fenilefrina foram determinadas em aortas torácicas com e sem endotélio. EC50 e resposta máxima (n = 8-12) foram comparadas através de ANOVA de dois fatores (two-way) / método de Bonferroni. Resultados: Estresse ou estresse em associação com o consumo de etanol aumentaram as respostas máximas de noradrenalina em aortas intactas. Essa hiper-reatividade foi eliminada pela remoção do endotélio, ou pela presença da indometacina ou ioimbina, mas não foi alterada pela presença de L-NAME. Enquanto isso, o consumo de etanol não alterou a reatividade à noradrenalina. As respostas da fenilefrina em aortas com e sem endotélio também permaneceram inalteradas independentemente do protocolo. Conclusão: O estresse crônico aumentou as respostas aórticas dos ratos à noradrenalina. Esse efeito é dependente do endotélio vascular e envolve a liberação de prostanóides vasoconstritores através da estimulação de α-2 adrenoceptores endoteliais. Além disso, o consumo crônico de etanol pareceu não influenciar as respostas de noradrenalina em aorta de rato, nem modificar o aumento de tais respostas observadas em consequência da exposição ao estresse.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

La Valvola Aortica Bicuspide (BAV) rappresenta la più comune anomalia cardiaca congenita, con un’incidenza dello 0,5%-2% nella popolazione generale. Si caratterizza per la presenza di due cuspidi valvolari anziché tre e comprende diverse forme. La BAV è frequentemente associata agli aneurismi dell’aorta toracica (TAA). La dilatazione dell’aorta espone al rischio di sviluppare le complicanze aortiche acute. Materiali e metodi Sono stati reclutati 20 probandi consecutivi sottoposti a chirurgia della valvola aortica e dell'aorta ascendente presso l'Unità di Chirurgia Cardiaca di Policlinico S.Orsola-Malpighi di TAA associata a BAV. Sono stati esclusi individui con una condizione sindromica predisponente l’aneurisma aortico. Ciascun familiare maggiorenne di primo grado è stato arruolato nello studio. L’analisi di mutazioni dell’intero gene ACTA2 è stata eseguita con la tecnica del “bidirectional direct sequencing”. Nelle forme familiari, l’intera porzione codificante del genoma è stata eseguita usando l’exome sequencing. Risultati Dopo il sequenziamento di tutti i 20 esoni e giunzioni di splicing di ACTA2 nei 20 probandi, non è stata individuata alcuna mutazione. Settantasette familiari di primo grado sono stati arruolati. Sono state identificate cinque forme familiari. In una famiglia è stata trovata una mutazione del gene MYH11 non ritenuta patogenetica. Conclusioni La mancanza di mutazioni, sia nelle forme sporadiche sia in quelle familiari, ci suggerisce che questo gene non è coinvolto nello sviluppo della BAV e TAA e, l’associazione che è stata riportata deve essere considerata occasionale. L’architettura genetica della BAV verosimilmente dovrebbe consistere in svariate differenti varianti genetiche che interagiscono in maniera additiva nel determinare un aumento del rischio.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The study aims to identify risk constellations for symptomatic spinal cord malperfusion in patients undergoing extensive stent-graft coverage of the thoracic aorta.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVE: Autopsy determination of fatal hemorrhage as the cause of death is often a difficult diagnosis in forensic medicine. No quantitative system for accurately measuring the blood volume in a corpse has been developed. MATERIALS AND METHODS: This article describes the measurement and evaluation of the cross-sectional areas of major blood vessels, of the diameter of the right pulmonary artery, of the volumes of thoracic aorta and spleen on MDCT, and of the volumes of heart chambers on MRI in 65 autopsy-verified cases of fatal hemorrhage or no fatal hemorrhage. RESULTS: Most cases with a cause of death of "fatal hemorrhage" had collapsed vessels. The finding of a collapsed superior vena cava, main pulmonary artery, or right pulmonary artery was 100% specific for fatal hemorrhage. The mean volumes of the thoracic aorta and of each of the heart chambers and the mean cross-sectional areas of all vessels except the inferior vena cava and abdominal aorta were significantly smaller in fatal hemorrhage than in no fatal hemorrhage. CONCLUSION: For the quantitative differentiation of fatal hemorrhage from other causes of death, we propose a three-step algorithm with measurements of the diameter of the right pulmonary artery, the cross-sectional area of the main pulmonary artery, and the volume of the right atrium (specificity, 100%; sensitivity, 95%). However, this algorithm must be corroborated in a prospective study, which would eliminate the limitations of this study. Quantitative postmortem cross-sectional imaging might become a reliable objective method to assess the question of fatal hemorrhage in forensic medicine.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

PURPOSE: This study was conducted to create an animal model for thoracic aortic transection that is suitable for thoracic endograft research. MATERIALS AND METHODS: Percutaneous aortic transection creation was attempted in 12 sheep. A custom collapsible circumferential cutting device was inserted into the proximal descending thoracic aorta via a femoral approach with an 11-F delivery catheter. The device was deployed 2 cm distal to the left subclavian artery origin and rotated 20 times to create aortic transection. Aortic diameters, mean aortic pressures, and heart rates were tested for degrees of difference between measurements before and after the creation of transection. On necropsy, the extent of aortic damage was classified as none, nontransmural, or transmural, and aortic transection was classified as none, partial, or circumferential. RESULTS: On angiography, creation of transmural thoracic aortic transection was successful in 91.7% (11/12) of animals. Aortic transection was circumferential in 54.4% (6/11) of animals and partial in 45.6% (5/11) of animals. Mean aortic diameter was 19.6 +/- 3.4 mm (range 12-24 mm) pre-transection and 25.8 +/- 4.5 mm (range 17.8-33 mm) post-transection (P = .0003). Pre-transection, mean aortic pressure was 79 +/- 13.8 mmHg, and 64.6 +/- 15.8 mmHg 15 min post-transection (P = .041). Pre-transection, mean heart rate was 94.5 +/- 17.2 beats per minute (bpm), and 105.8 +/- 17.2 bpm 15 min post-transection (P = .0057). CONCLUSIONS: Thoracic aortic transection was successfully created percutaneously in most animals. The animals remained in hemodynamically stable condition for as long as 240 minutes after the creation of aortic injury. This percutaneous animal model is straightforward and may be of potential value for future thoracic endograft research.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVES: Endovascular repair of the descending thoracic aorta is a very promising technique in elective and, particularly, emergency situations. This study assessed the impact of urgency of the procedure on outcome and mid-term quality of life in surviving patients. METHODS: Post hoc analysis of prospectively collected data of 58 consecutive patients (January 2001-December 2005) with surgical pathologies of the descending thoracic aorta treated by endovascular means. Six patients were excluded due to recent operations on the ascending aorta before thoracic endovascular repair. The remaining patients (n=52) were 69+/-10 years old, and 43 were men (83%). Twenty-seven had been treated electively, and 25 for emergency indications. Reasons for emergency were acute type B aortic dissections with or without malperfusion syndrome in 14, and aortic ruptures in 11 cases. Follow-up was 29+/-16 months. Endpoints were perioperative and late morbidity and mortality rates and long-term quality of life as assessed by the short form health survey (SF-36) and Hospital Anxiety and Depression Scale questionnaires. RESULTS: Cohorts were comparable regarding age, sex, cardiovascular risk factors, and comorbidities. Perioperative mortality was somewhat higher in emergency cases (12% vs 4%, p=0.34). Paraplegia occurred in one patient in each cohort (4%). Overall quality of life after two and a half years was similar in both treatment cohorts: 72 (58-124) after emergency, and 85 (61-105) after elective endovascular aortic repair (p=0.98). Normal scores range from 85 to 115. Anxiety and depression scores were in the normal range and comparable. CONCLUSIONS: Thoracic endovascular aortic repair is an excellent and safe treatment option for the diseased descending aorta, particularly in emergency situations. Early morbidity and mortality rates can be kept very low. Mid-term quality of life was not affected by the urgency of the procedure. Similarly, mid-term anxiety and depression scores were not increased after emergency situations.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND: Several technical advances in thoracic aortic surgery, such as the use of antegrade cerebral perfusion, avoidance of cross-clamping and the application of glue, have beneficially influenced postoperative outcome. The aim of the present study was to analyse the impact of these developments on outcome of patients undergoing surgery of the thoracic aorta. METHODS AND RESULTS: Between January 1996 and December 2005, 835 patients (37.6%) out of 2215 aortic patients underwent surgery on the thoracic ascending aorta or the aortic arch at our institution. All in-hospital data were assessed. Two hundred and forty-one patients (28.8%) suffered from acute type A dissection (AADA). Overall aortic caseload increased from 41 patients in 1996 to 141 in 2005 (+339%). The increase was more pronounced for thoracic aortic aneurysms (TAA) (+367.9%), than for acute type A aortic dissections (+276.9%). Especially in TAA, combined procedures increased and the amount of patients with impaired left ventricular function (EF <50%) raised up from 14% in 1996 to 24% in 2005. Average age remained stable. Logistic regression curve revealed a significant decrease in mortality (AADA) and in the overall incidence of neurological deficits. CONCLUSIONS: Technical advances in the field of thoracic aortic surgery lead to a decrease of mortality and morbidity, especially in the incidence of adverse neurological events, in a large collective of patients. Long-term outcome and quality of life are better, since antegrade cerebral perfusion has been introduced.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVE To analyse our results of using a double arterial perfusion strategy to avoid lower body hypothermic circulatory arrest after extensive thoracic aortic surgery. METHODS We analysed the intra- and perioperative courses of 10 patients (median age 58 years, median logistic EuroSCORE 14.6) who underwent extensive thoracic aortic surgery with a double arterial perfusion strategy. The main goal of double arterial perfusion is to separate myocardial and supra-aortic from systemic perfusion. Aortic repair starts at the most distal level of the descending aorta, followed by reinsertion of the supra-aortic vessels, and ends with completion of the proximal anastomosis or by any kind of root repair as needed. RESULTS Seven of 10 patients had prior surgery of the thoracic aorta. Indications for surgery were post-dissection aneurysm in 4 patients, true aneurysm in 3, anastomotic aneurysms in 2 and Type B aortic dissection with pseudo-coarctation in 1. Surgical access was performed through median sternotomy with left hemi-clamshell extension in all cases. There was no in-hospital mortality, but perioperative neurological symptoms occurred in 2 patients. These 2 patients developed delayed stroke (after awaking) after an initial uneventful clinical course, and in 1 of them, neurological symptoms resolved completely during follow-up. The median follow-up was 7 (±13) months. There was no death and no need for additional redo surgery during this observational period. CONCLUSIONS Extensive surgery of the thoracic aorta using a double arterial perfusion technique in order to avoid lower body hypothermic circulatory arrest is an attractive option. Further refinements of this technique may enable the safe and effective simultaneous multisegmental treatment of thoracic aortic pathology in patients who would otherwise have to undergo a two-step surgical approach.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVES The purpose of this study is to delineate changes in aortic geometry and diameter due to dissection. BACKGROUND Aortic diameter is the major criterion for elective ascending aortic replacement for dilated ascending aortas to prevent aortic dissection. However, recommendations are made on the basis of clinical experience and observation of diameters of previously dissected aortas. METHODS Six tertiary centers on 2 continents reviewed their acute aortic dissection type A databases, which contained 1,821 patients. Included were all non-Marfan patients with nonbicuspid aortic valves who had undergone computed tomography angiography <2 years before and within 12 h after aortic dissection onset. Aortic geometry before and after dissection onset were compared. RESULTS Altogether, 63 patients were included (27 spontaneous and 36 retrograde dissections, median age 68 [57; 77] years; 54% were men). In all but 1 patient, maximum ascending aortic diameter was <55 mm before aortic dissection onset. The largest increase in diameter and volume induced by the dissection were observed in the ascending aorta (40.1 [36.6; 45.3] mm vs. 52.9 [46.1; 58.6] mm, +12.8 mm; p < 0.001; 124.0 [90.8; 162.5] cm(3) vs. 171.0 [147.0; 197.0] cm(3), +47 cm(3); p < 0.001). Mean aortic arch diameter increased from 39.8 (30.5; 42.6) mm to 46.4 (42.0; 51.6) mm (+6.6 mm; p < 0.001) and descending thoracic aorta diameter from 31.2 (27.0; 33.3) mm to 34.9 (30.9; 39.5) mm (+3.7 mm; p < 0.001). Changes in thoracic aorta geometry were similar for spontaneous and retrograde etiology. CONCLUSIONS Geometry of the thoracic aorta is affected by aortic dissection, leading to an increase in diameter that is most pronounced in the ascending aorta. Both spontaneous and retrograde dissection result in similar aortic geometry changes.