994 resultados para Superfície de titânio. Oxidação a plasma. Osteoblastos. Implantes dentais. Biomateriais


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, the influence of modifications of the cp-Ti and Ti 6Al 4V alloy, by treating the surface with NaOH and depositing titanium oxide and hydroxyapatite by sol-gel method, on their biocompatibility was studied. The coatings were characterized by scanning electron microscopy and X-ray diffraction which showed that the coatings on Ti 6Al 4V are better than on cp-Ti. Adhesion tests showed that adhesion strength of the coatings on cp-Ti substrate is less than on Ti 6Al 4V as well as cytotoxicity for L929 fibroblast cells is higher

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Neste trabalho investigou-se a modificação de superfície do titânio pela irradiação com feixe de Laser Nd:YAG. Os parâmetros do laser como a potência, o comprimento de onda, a frequência, a velocidade de varredura e a área de exposição foram mantidos constantes, exceto o espaçamento da matriz, o qual foi de 0,01 e 0,02 mm. A caracterização da superfície foi realizada por Microscopia Eletrônica de Varredura (MEV) e Difração de Raios X (DRX), sendo que os espectros foram refinados pelo método Rietveld. Pela análise de MEV, observou-se uma mudança na topografia, obtendo uma superfície rugosa produzida pelo fenômeno de ablação. As análises por Rietveld dos espectros de difração de raios X detectaram TiN, Ti2N, TiO2 (anatásio e rutilo), sendo que a amostra com espaçamento 0,01 mm apresentou uma maior quantidade de óxidos e nitretos. Isso pode ser devido à sobreposição do feixe, induzindo à formação de uma superfície com maior estabilidade termodinâmica. Os óxidos e nitretos obtidos são de grande importância, pois são responsáveis por produzir uma maior interação entre o osso-implante.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work aims to develop a methodology for analysis of images using overlapping, which assists in identification of microstructural features in areas of titanium, which may be associated with its biological response. That way, surfaces of titanium heat treated for 08 (eight) different ways have been subjected to a test culture of cells. It was a relationship between the grain, texture and shape of grains of surface of titanium (attacked) trying to relate to the process of proliferation and adhesion. We used an open source software for cell counting adhered to the surface of titanium. The juxtaposition of images before and after cell culture was obtained with the aid of micro-hardness of impressions made on the surface of samples. From this image where there is overlap, it is possible to study a possible relationship between cell growth with microstructural characteristics of the surface of titanium. This methodology was efficient to describe a set of procedures that are useful in the analysis of surfaces of titanium subjected to a culture of cells

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Interstitial compounds of titanium have been mainly studied due to the large range of properties acquired when C, N, O and H atoms are added. In this work, surfaces of TiCxNy were produced by thermochemical treatments assisted by plasma with different proportions of Ar + N2 + CH4 gas mixture. The Ar gas flow was fixed in 4 sccm, varying only N2 and CH4 gas flows. During the thermochemical treatment, the plasma was monitored by Optical Emission Spectroscopy (OES) for the investigation of the influence of active species. After treatments, C and N concentration profile, crystalline and amorphous phases were analyzed by Nuclear Reaction (NRA). Besides tribomechanical properties of the Ti surface were studied through the nanohardness measurements and friction coefficient determination. The worn areas were evaluated by profilometry and Scanning Electronic Microscope (SEM) in order to verify the wear mechanism present in each material. It has been seen which the properties like nanohardness and friction coefficient have strong relation with luminous intensity of species of the plasma, suggesting a using of this characteristic as a parameter of process

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The short dental implants represent an option of previsible treatment, its main indication lives in the possibility of avoiding techniques surgical invasive. The literature in the display that the geometry of the implants is of vital importance, combined with wide diameters and surface treatment, mainly when the bone quality is unfavorable. The mechanical resistance can be enlarged, increasing the number of implants and being used the spliting among them. A rigorous protocol prosthodontist should be following with intention of to avoid oblique loads and to control habits parafuncionais. We aimed at to discuss, through a wide bibliographical revision the short dental implants, their characteristics and indications, giving emphasis to the aspects biomechanic of the same ones. Material and Method: The bases given: Pubmed, ISI and Dentistry Oral Science from 1990 to 2009, were consulted to identify researches related to the length of the dental implants, with emphasis to the considered short and the biomechanics related to the same ones. They were located 568 articles, being selected 69 that gathered the inclusion criteria. Result: Among these 69 selected, 26 articles agreed the evidence level. Conclusion: Inside of the limits of appraised data, it can be concluded that the short implants represent a good treatment alternative, especially for cases with reduced bone bed. However a rigorous indication protocol and use should be followed for warranty of the success of the treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dental implants represent a great improvement in Dentistry in respect to rehabilitation of edentulous ridges due to the functional and aesthetic reestablishment with long-term predictability and success. However, the effectiveness of this treatment relies on successful osseointegration during the healing period. In this way, the applicability of dental implants in patients with diabetes mellitus (DM) remains controversial, by the fact that the hyperglycemic status presents a negative effect on the osseointegration. It is not clear yet if the therapy with dental implants is an absolute contraindication to these patients. For this reason, the aim of the present study is to review the literature about the treatment with dental implants in patients with diabetes and to propose a protocol to perform dental implants in patients with diabetes. Diabetes has been considered a relative contraindication to dental implants, as the patients with adequate metabolic control can be treated with this kind of therapy, because inadequate metabolic control can lead to the failure of the treatment. Besides, there are risk factors for the diabetic implant patient that may decrease the success rates of dental implants therapy. In this way, the dentist should understand all the relevant implications before considering the indication of dental implants to patients with diabetes. It is important to have more controlled studies to evaluate the effects of diabetes on the implant-tissue interface and further investigations are necessary in order to elucidate the role of insulin and molecular mechanisms that might interfere on the osseointegration in patients with diabetes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Infiltration of organic fluids and microorganisms at the abutment/implant interface may result in bacterial infection of peri-implant tissues. Internal colonization of periodontal pathogens may be caused by bacteria trapped during installation or penetration of abutment/implant leakage. The aim of this study was to detect periodontal pathogens in the internal area of dental implants before loading. Materials and Methods: Seventy-eight implants in 32 partially edentulous subjects were selected for this evaluation. A bacterial biofilm sample of the internal surface of each implant was taken and analyzed for the presence of 40 microorganisms by checkerboard DNA-DNA hybridization, prior to installation of healing or any other prosthetic abutment. Discussion: Bacteria were detected in 20 patients (62.5%), distributed in 41 implants (52.6%). Forty-seven percent of implants showed no bacterial detection. Spontaneous early implant exposure to oral cavity during the healing period was not significant (P >0.05) to increase bacterial prevalence, but implants placed at mandible had higher bacterial prevalence than maxillary ones. Conclusion: The internal surface of dental implants can serve as a reservoir of periodontal pathogens for future implant/abutment interface.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Commercially pure Titanium (cp Ti) is a material largely used in orthopedic and dental implants due to its biocompatibility properties. Changes in the surface of cp Ti can determine the functional response of the cells such as facilitating implant fixation and stabilization, and increased roughness of the surface has been shown to improve adhesion and cellular proliferation. Various surface modification methods have been developed to increase roughness, such as mechanical, chemical, electrochemical and plasma treatment. An argon plasma treatment generates a surface that has good mechanical proprieties without chemical composition modification. Besides the topography, biological responses to the implant contribute significantly to its success. Oxidative stress induced by the biomaterials is considered one of the major causes of implant failure. For this reason the oxidative potential of titanium surfaces subjected to plasma treatment was evaluated on this work. CHO-k1 cells were cultivated on smooth or roughed Ti disks, and after three days, the redox balance was investigated measuring reactive oxygen species (ROS) generation, total antioxidant capacity and biomarkers of ROS attack. The results showed cells grown on titanium surfaces are subjected to intracellular oxidative stress due to hydrogen peroxide generation. Titanium discs subjected to the plasma treatment induced less oxidative stress than the untreated ones, which resulted in improved cellular ability. Our data suggest that plasma treated titanium may be a more biocompatible biomaterial.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Commercially pure Titanium (cp Ti) is a material largely used in orthopedic and dental implants due to its biocompatibility properties. Changes in the surface of cp Ti can determine the functional response of the cells such as facilitating implant fixation and stabilization, and increased roughness of the surface has been shown to improve adhesion and cellular proliferation. Various surface modification methods have been developed to increase roughness, such as mechanical, chemical, electrochemical and plasma treatment. An argon plasma treatment generates a surface that has good mechanical proprieties without chemical composition modification. Besides the topography, biological responses to the implant contribute significantly to its success. Oxidative stress induced by the biomaterials is considered one of the major causes of implant failure. For this reason the oxidative potential of titanium surfaces subjected to plasma treatment was evaluated on this work. CHO-k1 cells were cultivated on smooth or roughed Ti disks, and after three days, the redox balance was investigated measuring reactive oxygen species (ROS) generation, total antioxidant capacity and biomarkers of ROS attack. The results showed cells grown on titanium surfaces are subjected to intracellular oxidative stress due to hydrogen peroxide generation. Titanium discs subjected to the plasma treatment induced less oxidative stress than the untreated ones, which resulted in improved cellular ability. Our data suggest that plasma treated titanium may be a more biocompatible biomaterial.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O titânio e suas ligas são os materiais mais comumente utilizados na substituição de tecidos duros por possuírem resistência mecânica, biocompatibilidade, resistência à corrosão e fácil manipulação. Embora o titânio possua várias vantagens sobre outros biomateriais, seu uso em longo prazo pode ocasionar problemas de rejeição. A modificação da superfície do titânio a fim de criar microrrugosidades é uma estratégia efetiva para melhorar a adesão e proliferação celular sobre implantes. Quando um implante danifica ou invade as barreiras epitelial e das mucosas, pode servir como reservatório para microrganismos e desta forma predispor à infecção. Neste sentido, o objetivo deste trabalho foi modificar a superfície do titânio, utilizando nanopartículas de prata (Ag) e lectina, a fim de melhorar a sua biocompatibilidade e conferir propriedades antimicrobianas a este material. O racional por trás destas mudanças é que a criação de uma topografia em nanoescala pode contribuir para mimetizar o ambiente celular melhorando a osseointegração e diminuindo o risco de infecção. Em nosso estudo, nanotubos de dióxido de titânio (NTs-TiO2) com estrutura bem distribuída e organizada, com diâmetro em torno de 70–80nm, foram sintetizados por anodização eletroquímica e decorados com nanopartículas de Ag usando a técnica de layer-by-layer (LbL), enquanto a lectina do peixe Oreochromis niloticus (OniL) foi incorporada aos NTs-TiO2 por spin coating. Estas amostras foram caracterizadas e avaliadas quanto a sua citotoxidade, adesão celular, potencial osteogênico e atividade bactericida. Nossos resultados mostraram que tanto as nanopartículas de Ag, como a Onil foram incorporadas com sucesso à superfície dos NTs-TiO2. Entretanto nossas preparações de LbL não foram capazes de melhorar a biocompatibilidade ou inibir o crescimento de bactérias nos NTs-TiO2. Por outro lado, a funcionalização dos NTs-TiO2 com a OniL induziu eficientemente a adesão e proliferação dos osteoblastos. Nossos resultados apontam para o uso da lectina OniL para melhorar a qualidade dos implantes de NT-TiO2 existentes.