915 resultados para Subclavian Artery


Relevância:

60.00% 60.00%

Publicador:

Resumo:

During a Christmas party, two male guests started fighting. The perpetrator was allegedly pushed onto a glass table by the victim or fell into the table together with that man so that the glass top broke and caused a cut wound on the perpetrator's back. According to his statement he then threw a fragment of the broken glass table in the direction of the other man hitting him accidentally in a way so that the subclavian artery was severed and he died from exsanguination. Tests on the breaking characteristics of the glass table, the flying behaviour and the kinetics of thrown glass fragments conducted on various models supported the conclusion that the fatal injury on the victim's neck could not have been caused by a thrown glass fragment. It was much more likely that a stab with a blade-shaped glass fragment was the cause of the fatal injuries.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose:To determine the potential of minimally invasive postmortem computed tomographic (CT) angiography combined with image-guided tissue biopsy of the myocardium and lungs in decedents who were thought to have died of acute chest disease and to compare this method with conventional autopsy as the reference standard.Materials and Methods:The responsible justice department and ethics committee approved this study. Twenty corpses (four female corpses and 16 male corpses; age range, 15-80 years), all of whom were reported to have had antemortem acute chest pain, were imaged with postmortem whole-body CT angiography and underwent standardized image-guided biopsy. The standard included three biopsies of the myocardium and a single biopsy of bilateral central lung tissue. Additional biopsies of pulmonary clots for differentiation of pulmonary embolism and postmortem organized thrombus were performed after initial analysis of the cross-sectional images. Subsequent traditional autopsy with sampling of histologic specimens was performed in all cases. Thereafter, conventional histologic and autopsy reports were compared with postmortem CT angiography and CT-guided biopsy findings. A Cohen k coefficient analysis was performed to explore the effect of the clustered nature of the data.Results:In 19 of the 20 cadavers, findings at postmortem CT angiography in combination with CT-guided biopsy validated the cause of death found at traditional autopsy. In one cadaver, early myocardial infarction of the papillary muscles had been missed. The Cohen κ coefficient was 0.94. There were four instances of pulmonary embolism, three aortic dissections (Stanford type A), three myocardial infarctions, three instances of fresh coronary thrombosis, three cases of obstructive coronary artery disease, one ruptured ulcer of the ascending aorta, one ruptured aneurysm of the right subclavian artery, one case of myocarditis, and one pulmonary malignancy with pulmonary artery erosion. In seven of 20 cadavers, CT-guided biopsy provided additional histopathologic information that substantiated the final diagnosis of the cause of death.Conclusion:Postmortem CT angiography combined with image-guided biopsy, because of their minimally invasive nature, have a potential role in the detection of the cause of death after acute chest pain.© RSNA, 2012.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Transcatheter aortic valve implantation (TAVI) for the treatment of symptomatic severe aortic stenosis has emerged as an effective treatment for high risk patients. In 2002 TAVI was performed for the first time in a human by Alain Cribier, using an antegrade access approach via the femoral vein, crossing the intra-atrial septum after puncture and passing the native aortic valve in the direction of blood flow. This technically demanding approach was subsequently replaced by retrograde transfemoral arterial access. For patients with severe peripheral vascular disease or inadequately sized femoral arteries, the transapical route provides an alternative route with antegrade access to the aortic valve via puncture of the anterolateral wall of the left ventricle. The transsubclavian access approach using most frequently the left subclavian artery and direct transaortic access have been introduced more recently and attest to the versatility of TAVI in terms of access site. This article will focus on the different access site options available to operators, provide a step-by-step guide through the procedure, and a detailed description of the technological evolution of transcatheter heart valve systems.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: This study was conducted to create an animal model for thoracic aortic transection that is suitable for thoracic endograft research. MATERIALS AND METHODS: Percutaneous aortic transection creation was attempted in 12 sheep. A custom collapsible circumferential cutting device was inserted into the proximal descending thoracic aorta via a femoral approach with an 11-F delivery catheter. The device was deployed 2 cm distal to the left subclavian artery origin and rotated 20 times to create aortic transection. Aortic diameters, mean aortic pressures, and heart rates were tested for degrees of difference between measurements before and after the creation of transection. On necropsy, the extent of aortic damage was classified as none, nontransmural, or transmural, and aortic transection was classified as none, partial, or circumferential. RESULTS: On angiography, creation of transmural thoracic aortic transection was successful in 91.7% (11/12) of animals. Aortic transection was circumferential in 54.4% (6/11) of animals and partial in 45.6% (5/11) of animals. Mean aortic diameter was 19.6 +/- 3.4 mm (range 12-24 mm) pre-transection and 25.8 +/- 4.5 mm (range 17.8-33 mm) post-transection (P = .0003). Pre-transection, mean aortic pressure was 79 +/- 13.8 mmHg, and 64.6 +/- 15.8 mmHg 15 min post-transection (P = .041). Pre-transection, mean heart rate was 94.5 +/- 17.2 beats per minute (bpm), and 105.8 +/- 17.2 bpm 15 min post-transection (P = .0057). CONCLUSIONS: Thoracic aortic transection was successfully created percutaneously in most animals. The animals remained in hemodynamically stable condition for as long as 240 minutes after the creation of aortic injury. This percutaneous animal model is straightforward and may be of potential value for future thoracic endograft research.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Previous analyses of aortic displacement and distension using computed tomography angiography (CTA) were performed on double-oblique multi-planar reformations and did not consider through-plane motion. The aim of this study was to overcome this limitation by using a novel computational approach for the assessment of thoracic aortic displacement and distension in their true four-dimensional extent. Vessel segmentation with landmark tracking was executed on CTA of 24 patients without evidence of aortic disease. Distension magnitudes and maximum displacement vectors (MDV) including their direction were analyzed at 5 aortic locations: left coronary artery (COR), mid-ascending aorta (ASC), brachiocephalic trunk (BCT), left subclavian artery (LSA), descending aorta (DES). Distension was highest for COR (2.3 ± 1.2 mm) and BCT (1.7 ± 1.1 mm) compared with ASC, LSA, and DES (p < 0.005). MDV decreased from COR to LSA (p < 0.005) and was highest for COR (6.2 ± 2.0 mm) and ASC (3.8 ± 1.9 mm). Displacement was directed towards left and anterior at COR and ASC. Craniocaudal displacement at COR and ASC was 1.3 ± 0.8 and 0.3 ± 0.3 mm. At BCT, LSA, and DES no predominant displacement direction was observable. Vessel displacement and wall distension are highest in the ascending aorta, and ascending aortic displacement is primarily directed towards left and anterior. Craniocaudal displacement remains low even close to the left cardiac ventricle.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The right-sided aorta associated with an aberrant left subclavian artery is a rare anomaly of the aortic branches in the upper mediastinum. We present a 62-year-old patient suffering from an acute dissection of the ascending aorta associated with hemopericardium. In this case, there was also aneurysmal dilatation of the origin of the left subclavian artery, known as diverticulum of Kommerell.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The recently introduced rabbit blood shunt subarachnoid haemorrhage model is based on the two standard procedures of subclavian artery cannulation and transcutaneous cisterna magna puncture. An extracorporeal shunt placed in between the arterial system and the subarachnoid space allows examiner-independent SAH in a closed cranium. Despite its straightforwardness, it is worth examining some specific features and characteristics of the model. We outline technical considerations to successfully perform the model with minimal mortality and morbidity. In addition, we discuss outcome measures, advantages and limitations, and the applicability of the model for the study of early brain injury and delayed cerebral vasospasm after SAH.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

INTRODUCTION Native-MR angiography (N-MRA) is considered an imaging alternative to contrast enhanced MR angiography (CE-MRA) for patients with renal insufficiency. Lower intraluminal contrast in N-MRA often leads to failure of the segmentation process in commercial algorithms. This study introduces an in-house 3D model-based segmentation approach used to compare both sequences by automatic 3D lumen segmentation, allowing for evaluation of differences of aortic lumen diameters as well as differences in length comparing both acquisition techniques at every possible location. METHODS AND MATERIALS Sixteen healthy volunteers underwent 1.5-T-MR Angiography (MRA). For each volunteer, two different MR sequences were performed, CE-MRA: gradient echo Turbo FLASH sequence and N-MRA: respiratory-and-cardiac-gated, T2-weighted 3D SSFP. Datasets were segmented using a 3D model-based ellipse-fitting approach with a single seed point placed manually above the celiac trunk. The segmented volumes were manually cropped from left subclavian artery to celiac trunk to avoid error due to side branches. Diameters, volumes and centerline length were computed for intraindividual comparison. For statistical analysis the Wilcoxon-Signed-Ranked-Test was used. RESULTS Average centerline length obtained based on N-MRA was 239.0±23.4 mm compared to 238.6±23.5 mm for CE-MRA without significant difference (P=0.877). Average maximum diameter obtained based on N-MRA was 25.7±3.3 mm compared to 24.1±3.2 mm for CE-MRA (P<0.001). In agreement with the difference in diameters, volumes obtained based on N-MRA (100.1±35.4 cm(3)) were consistently and significantly larger compared to CE-MRA (89.2±30.0 cm(3)) (P<0.001). CONCLUSIONS 3D morphometry shows highly similar centerline lengths for N-MRA and CE-MRA, but systematically higher diameters and volumes for N-MRA.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND Retrograde diastolic blood flow in the proximal descending aorta (DAo) connecting complex plaques (≥4 mm thick) with brain-supplying supra-aortic arteries may constitute a source of stroke. Yet, data only from high-risk populations (cryptogenic stroke patients with aortic atheroma≥3 mm) regarding the prevalence of this potential stroke mechanism are available. We aimed to quantify the frequency of this mechanism in unselected patients with cryptogenic stroke after routine diagnostics and controls without a history of stroke. METHODS 88 patients (67 stroke patients, 21 cardiac controls) were prospectively included. 3D T1-weighted bright blood MRI of the aorta was applied for the detection of complex DAo atheroma. ECG-triggered and navigator-gated 4D flow MRI allowed measuring time-resolved 3D blood flow in vivo. Potential retrograde embolization pathways were defined as the co-occurrence of complex plaques and retrograde blood flow in the DAo reaching the outlet of (a) the left subclavian artery, (b) the left common carotid artery, or/and (c) the brachiocephalic trunk. The frequency of these pathways was analyzed by importing 2D plaque images into 3D blood flow visualization software. RESULTS Complex DAo plaques were more frequent in stroke patients (44 in 31/67 patients (46.3%) vs. 5 in 4/21 controls (19.1%); p=0.039), especially in older patients (29/46 (63.04%) patients≥60 years of age with 41 plaques vs. 2/21 (9.14%) patients<60 years of age with 3 plaques; p<0.001). Contrary to our assumption, retrograde diastolic blood flow at the DAo occurred in every patient irrespective of the existence of plaques with a similar extent in both groups (26±14 vs. 32±18 mm; p=0.114). Therefore, only the higher prevalence of complex DAo plaques in stroke patients resulted in a three times higher frequency of potential retrograde embolization pathways compared to controls (22/67 (32.8%) vs. 2/21 (9.5%) controls; p=0.048). CONCLUSIONS This study revealed that retrograde flow in the descending aorta is a common phenomenon not only in stroke patients. The existence of potential retrograde embolization pathways depends mainly on the occurrence of complex plaques in the area 0 to ∼30 mm behind the outlet of the left subclavian artery, which is exposed to flow reversal. In conclusion, we have shown that the frequency of potential retrograde embolization pathways was significantly higher in stroke patients suggesting that this mechanism may play a role in retrograde brain embolism.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE The purpose of this study was to identify morphologic factors affecting type I endoleak formation and bird-beak configuration after thoracic endovascular aortic repair (TEVAR). METHODS Computed tomography (CT) data of 57 patients (40 males; median age, 66 years) undergoing TEVAR for thoracic aortic aneurysm (34 TAA, 19 TAAA) or penetrating aortic ulcer (n = 4) between 2001 and 2010 were retrospectively reviewed. In 28 patients, the Gore TAG® stent-graft was used, followed by the Medtronic Valiant® in 16 cases, the Medtronic Talent® in 8, and the Cook Zenith® in 5 cases. Proximal landing zone (PLZ) was in zone 1 in 13, zone 2 in 13, zone 3 in 23, and zone 4 in 8 patients. In 14 patients (25%), the procedure was urgent or emergent. In each case, pre- and postoperative CT angiography was analyzed using a dedicated image processing workstation and complimentary in-house developed software based on a 3D cylindrical intensity model to calculate aortic arch angulation and conicity of the landing zones (LZ). RESULTS Primary type Ia endoleak rate was 12% (7/57) and subsequent re-intervention rate was 86% (6/7). Left subclavian artery (LSA) coverage (p = 0.036) and conicity of the PLZ (5.9 vs. 2.6 mm; p = 0.016) were significantly associated with an increased type Ia endoleak rate. Bird-beak configuration was observed in 16 patients (28%) and was associated with a smaller radius of the aortic arch curvature (42 vs. 65 mm; p = 0.049). Type Ia endoleak was not associated with a bird-beak configuration (p = 0.388). Primary type Ib endoleak rate was 7% (4/57) and subsequent re-intervention rate was 100%. Conicity of the distal LZ was associated with an increased type Ib endoleak rate (8.3 vs. 2.6 mm; p = 0.038). CONCLUSIONS CT-based 3D aortic morphometry helps to identify risk factors of type I endoleak formation and bird-beak configuration during TEVAR. These factors were LSA coverage and conicity within the landing zones for type I endoleak formation and steep aortic angulation for bird-beak configuration.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a artéria subclávia direita durante a ecografia do primeiro trimestre, descrever a técnica para a sua avaliação e, em caso de identificação de artéria subclávia direita aberrante (ARSA), determinar sua associação com alterações cromossómicas e/ou malformações cardíacas e sua orientação.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A case of iatrogenic fistula from the right internal mammary artery to the subclavian vein following subclavian vein catheterization is reported. The patient had undergone percutaneous Intracath catheterization of the subclavian vein to treat hypovolemic shock during the surgical treatment of ectopic pregnancy. She had remained symptom-free for 7 years and then started to complain of effort dyspnea. The patient was found to have a thrill and a bruit at the subclavian region, and arteriography demonstrated a fistula between the right internal mammary artery and the subclavian vein. The fistula was successfully closed by embolization with a percutaneous detachable balloon catheter. © 1993.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This case report describes removal of a knotted, subclavian, pulmonary artery catheter using a tracheostomy dilator. With this simple method an invasive procedure might be averted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The accurate measurement of Cardiac output (CO) is vital in guiding the treatment of critically ill patients. Invasive or minimally invasive measurement of CO is not without inherent risks to the patient. Skilled Intensive Care Unit (ICU) nursing staff are in an ideal position to assess changes in CO following therapeutic measures. The USCOM (Ultrasonic Cardiac Output Monitor) device is a non-invasive CO monitor whose clinical utility and ease of use requires testing. Objectives To compare cardiac output measurement using a non-invasive ultrasonic device (USCOM) operated by a non-echocardiograhically trained ICU Registered Nurse (RN), with the conventional pulmonary artery catheter (PAC) using both thermodilution and Fick methods. Design Prospective observational study. Setting and participants Between April 2006 and March 2007, we evaluated 30 spontaneously breathing patients requiring PAC for assessment of heart failure and/or pulmonary hypertension at a tertiary level cardiothoracic hospital. Methods SCOM CO was compared with thermodilution measurements via PAC and CO estimated using a modified Fick equation. This catheter was inserted by a medical officer, and all USCOM measurements by a senior ICU nurse. Mean values, bias and precision, and mean percentage difference between measures were determined to compare methods. The Intra-Class Correlation statistic was also used to assess agreement. The USCOM time to measure was recorded to assess the learning curve for USCOM use performed by an ICU RN and a line of best fit demonstrated to describe the operator learning curve. Results In 24 of 30 (80%) patients studied, CO measures were obtained. In 6 of 30 (20%) patients, an adequate USCOM signal was not achieved. The mean difference (±standard deviation) between USCOM and PAC, USCOM and Fick, and Fick and PAC CO were small, −0.34 ± 0.52 L/min, −0.33 ± 0.90 L/min and −0.25 ± 0.63 L/min respectively across a range of outputs from 2.6 L/min to 7.2 L/min. The percent limits of agreement (LOA) for all measures were −34.6% to 17.8% for USCOM and PAC, −49.8% to 34.1% for USCOM and Fick and −36.4% to 23.7% for PAC and Fick. Signal acquisition time reduced on average by 0.6 min per measure to less than 10 min at the end of the study. Conclusions In 80% of our cohort, USCOM, PAC and Fick measures of CO all showed clinically acceptable agreement and the learning curve for operation of the non-invasive USCOM device by an ICU RN was found to be satisfactorily short. Further work is required in patients receiving positive pressure ventilation.