991 resultados para Structural failure


Relevância:

60.00% 60.00%

Publicador:

Resumo:

El acero es, junto con el hormigón, el material más ampliamente empleado en la construcción de obra civil y de edificación. Además de su elevada resistencia, su carácter dúctil resulta un aspecto de particular interés desde el punto de vista de la seguridad estructural, ya que permite redistribuir esfuerzos a elementos adyacentes y, por tanto, almacenar una mayor energía antes del colapso final de la estructura. No obstante, a pesar de su extendida utilización, todavía existen aspectos relacionados con su comportamiento en rotura que necesitan una mayor clarificación y que permitirían un mejor aprovechamiento de sus propiedades. Cuando un elemento de acero es ensayado a tracción y alcanza la carga máxima, sufre la aparición de un cuello de estricción que plantea dificultades para conocer el comportamiento del material desde dicho instante hasta la rotura. La norma ISO 6892-1, que define el método a emplear en un ensayo de tracción con materiales metálicos, establece procedimientos para determinar los parámetros relacionados con este tramo último de la curva F − E. No obstante, la definición de dichos parámetros resulta controvertida, ya que éstos presentan una baja reproducibilidad y una baja repetibilidad que resultan difíciles de explicar. En esta Tesis se busca profundizar en el conocimiento del último tramo de la curva F − E de los aceros de construcción. Para ello se ha realizado una amplia campaña experimental sobre dos aceros representativos en el campo de la construcción civil: el alambrón de partida empleado en la fabricación de alambres de pretensado y un acero empleado como refuerzo en hormigón armado. Los dos materiales analizados presentan formas de rotura diferentes: mientras el primero de ellos presenta una superficie de rotura plana con una región oscura claramente apreciable en su interior, el segundo rompe según la clásica superficie en forma de copa y cono. La rotura en forma de copa y cono ha sido ampliamente estudiada en el pasado y existen modelos de rotura que han logrado reproducirla con éxito, en especial el modelo de Gurson- Tvergaard-Needleman (GTN). En cuanto a la rotura exhibida por el primer material, en principio nada impide abordar su reproducción numérica con un modelo GTN, sin embargo, las diferencias observadas entre ambos materiales en los ensayos experimentales permiten pensar en otro criterio de rotura. En la presente Tesis se realiza una amplia campaña experimental con probetas cilíndricas fabricadas con dos aceros representativos de los empleados en construcción con comportamientos en rotura diferentes. Por un lado se analiza el alambrón de partida empleado en la fabricación de alambres de pretensado, cuyo frente de rotura es plano y perpendicular a la dirección de aplicación de la carga con una región oscura en su interior. Por otro lado, se estudian barras de acero empleadas como armadura pasiva tipo B 500 SD, cuyo frente de rotura presenta la clásica superficie en forma de copa y cono. Estos trabajos experimentales han permitido distinguir dos comportamientos en rotura claramente diferenciados entre ambos materiales y, en el caso del primer material, se ha identificado un comportamiento asemejable al exhibido por materiales frágiles. En este trabajo se plantea la hipótesis de que el primer material, cuya rotura provoca un frente de rotura plano y perpendicular a la dirección de aplicación de la carga, rompe de manera cuasifrágil como consecuencia de un proceso de decohesión, de manera que la región oscura que se observa en el centro del frente de rotura se asemeja a una entalla circular perpendicular a la dirección de aplicación de la carga. Para la reproducción numérica de la rotura exhibida por el primer material, se plantea un criterio de rotura basado en un modelo cohesivo que, como aspecto novedoso, se hace depender de la triaxialidad de tensiones, parámetro determinante en el fallo de este tipo de materiales. Este tipo de modelos presenta varias ventajas respecto a los modelos GTN habitualmente empleados. Mientras los modelos GTN precisan de numerosos parámetros para su calibración, los modelos cohesivos precisan fundamentalmente de dos parámetros para definir su curva de ablandamiento: la tensión de decohesión ft y la energía de fractura GF . Además, los parámetros de los modelos GTN no son medibles de manera experimental, mientras que GF sí lo es. En cuanto a ft, aunque no existe un método para su determinación experimental, sí resulta un parámetro más fácilmente interpretable que los empleados por los modelos GTN, que utilizan valores como el porcentaje de huecos presentes en el material para iniciar el fenómeno de coalescencia o el porcentaje de poros que provoca una pérdida total de la capacidad resistente. Para implementar este criterio de rotura se ha desarrollado un elemento de intercara cohesivo dependiente de la triaxialidad de tensiones. Se han reproducido con éxito los ensayos de tracción llevados a cabo en la campaña experimental empleando dicho elemento de intercara. Además, en estos modelos la rotura se produce fenomenológicamente de la misma manera observada en los ensayos experimentales: produciéndose una decohesión circular en torno al eje de la probeta. En definitiva, los trabajos desarrollados en esta Tesis, tanto experimentales como numéricos, contribuyen a clarificar el comportamiento de los aceros de construcción en el último tramo de la curva F − E y los mecanismos desencadenantes de la rotura final del material, aspecto que puede contribuir a un mejor aprovechamiento de las propiedades de estos aceros en el futuro y a mejorar la seguridad de las estructuras construidas con ellos. Steel is, together with concrete, the most widely used material in civil engineering works. Not only its high strength, but also its ductility is of special interest from the point of view of the structural safety, since it enables stress distribution with adjacent elements and, therefore, more energy can be stored before reaching the structural failure. However, despite of being extensively used, there are still some aspects related to its fracture behaviour that need to be clarified and that will allow for a better use of its properties. When a steel item is tested under tension and reaches the maximum load point, necking process begins, which makes difficult to define the material behaviour from that moment onward. The ISO standard 6892-1, which defines the tensile testing method for metallic materials, describes the procedures to obtain some parameters related to this last section of the F − E curve. Nevertheless, these parameters have proved to be controversial, since they have low reproducibility and repeatibility rates that are difficult to explain. This Thesis tries to deepen the knowledge of the last section of the F − E curve for construction steels. An extensive experimental campaign has been carried out with two representative steels used in civil engineering works: a steel rod used for manufacturing prestressing steel wires, before the cold-drawing process is applied, and steel bars used in reinforced concrete structures. Both materials have different fracture surfaces: while the first of them shows a flat fracture surface, perpendicular to the loading direction with a dark region in the centre of it, the second one shows the classical cup-cone fracture surface. The cup-cone fracture surface has been deeply studied in the past and different numerical models have been able to reproduce it with success, with a special mention to the Gurson-Tvergaard-Needleman model (GTN). Regarding the failure surface shown by the first material, in principle it can be numerically reproduced by a GTN model, but the differences observed between both materials in the experimental campaign suggest thinking of a different failure criterium. In the present Thesis, an extensive experimental campaign has been carried out using cylindrical specimens made of two representative construction steels with different fracture behaviours. On one hand, the initial eutectoid steel rod used for manufacturing prestressing steel wires is analysed, which presents a flat fracture surface, perpendicular to the loading direction, and with a dark region in the centre of it. On the other hand, B 500 SD steel bars, typically used in reinforced concrete structures and with the typical cup-cone fracture surface, are studied. These experimental works have allowed distinguishing two clearly different fracture behaviours between both materials and, in the case of the first one, a fragile-like behaviour has been identified. For the first material, which shows a flat fracture surface perpendicular to the loading direction, the following hypothesis is proposed in this study: a quasi-brittle fracture is developed as a consequence of a decohesion process, with the dark region acting as a circular crack perpendicular to the loading direction. To reproduce numerically the fracture behaviour shown by the first material, a failure criterium based on a cohesive model is proposed in this Thesis. As an innovative contribution, this failure criterium depends on the stress triaxiality state of the material, which is a key parameter when studying fracture in this kind of materials. This type of models have some advantages when compared to the widely used GTN models. While GTN models need a high number of parameters to be defined, cohesive models need basically two parameters to define the softening curve: the decohesion stress ft and the fracture energy GF . In addition to this, GTN models parameters cannot be measured experimentally, while GF is indeed. Regarding ft, although no experimental procedure is defined for its obtention, it has an easier interpretation than the parameters used by the GTN models like, for instance, the void volume needed for the coalescence process to start or the void volume that leads to a total loss of the bearing capacity. In order to implement this failure criterium, a triaxiality-dependent cohesive interface element has been developed. The experimental results obtained in the experimental campaign have been successfully reproduced by using this interface element. Furthermore, in these models the failure mechanism is developed in the same way as observed experimentally: with a circular decohesive process taking place around the longitudinal axis of the specimen. In summary, the works developed in this Thesis, both experimental and numerical, contribute to clarify the behaviour of construction steels in the last section of the F − E curve and the mechanisms responsible for the eventual material failure, an aspect that can lead to a better use of the properties of these steels in the future and a safety improvement in the structures built with them.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La gestión de riesgos debe ser entendida como una determinación de vínculos entre lo que se asume como vulnerabilidad, y la forma en la que se determinarían o estimarían la probabilidad en la concurrencia de un determinado hecho, partiendo de la idea de la concurrencia de un fenómeno y las acciones necesarias que deberán llevarse a cabo. El tema de vulnerabilidad y riesgo, cada día toma más importancia a nivel mundial, a medida que pasa el tiempo es más notoria la vulnerabilidad de ciertas poblaciones ante la presencia de determinados peligros naturales como son: inundaciones, desbordes de ríos, deslizamientos de tierra y movimientos sísmicos. La vulnerabilidad aumenta, a medida que crece la deforestación. La construcción en lugares de alto riesgo, como por ejemplo, viviendas a orillas de los ríos, está condicionada por la localización y las condiciones de uso del suelo, infraestructura, construcciones, viviendas, distribución y densidad de población, capacidad de organización, etc. Es ahora donde la gestión de riesgos, juega un papel muy importante en la sociedad moderna, siendo esta cada vez más exigente con los resultados y calidad de productos y servicios, además de cumplir también, con la responsabilidad jurídica que trae la concepción, diseño y construcción de proyectos en zonas inundables. El presente trabajo de investigación, se centra en identificar los riesgos, aplicando soluciones estructurales y recomendaciones resilientes para edificaciones que se encuentren emplazadas en zonas inundables. Disminuyendo así el riesgo de fallo estructural y el número de víctimas considerablemente. Concluyendo con un Catálogo de Riesgos y Soluciones para edificaciones en zonas inundables. Risk management should be understood as a determination of links between what is assumed to be vulnerable , and how that would be determined or would estimate the probability in the occurrence of a certain event, based on the idea of the occurrence of a phenomenon and necessary actions to be carried out . The issue of vulnerability and risk, every day takes more importance globally, as time passes is more notorious vulnerability of certain populations in the presence of certain natural hazards such as floods, swollen rivers, landslides and earthquakes. Vulnerability increases as it grows deforestation. The construction in high-risk locations, such as homes on the banks of rivers, is conditioned by the location and conditions of land use, infrastructure, construction, housing, distribution and population density, organizational skills, etc. Now where risk management plays a very important role in modern society, is being increasingly demanding with the results and quality of products and services, and also comply with the legal responsibility that brings the conception, design and construction projects in flood zones. This research focuses on identifying risks, implementing structural solutions and resilients’ recommendations for buildings that are emplaced in flood zones. Thus decreasing the risk of structural failure and the number of victims significantly. Concluding with a Catalogue of Risks and Solutions for buildings in flood zones.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

En la presente investigación se analiza la causa del hundimiento del cuarto compartimento del Tercer Depósito del Canal de Isabel II el 8 de abril de 1905, uno de los más graves de la historia de la construcción en España: fallecieron 30 personas y quedaron heridas otras 60. El Proyecto y Construcción de esta estructura era de D. José Eugenio Ribera, una de las grandes figuras de la ingeniería civil en nuestro país, cuya carrera pudo haber quedado truncada como consecuencia del siniestro. Dado el tiempo transcurrido desde la ocurrencia de este accidente, la investigación ha partido de la recopilación de la información relativa al Proyecto y a la propia construcción de la estructura, para revisar a continuación la información disponible sobre el hundimiento. De la construcción de la cubierta es interesante destacar la atrevida configuración estructural, cubriéndose una inmensa superficie de 74.000 m2 mediante una sucesión de bóvedas de hormigón armado de tan sólo 5 cm de espesor y un rebajamiento de 1/10 para salvar una luz de 6 m, que apoyaban en pórticos del mismo material, con pilares también muy esbeltos: 0,25 m de lado para 8 m de altura. Y todo ello en una época en la que la tecnología y conocimiento de las estructuras con este "nuevo" material se basaban en buena medida en el desarrollo de patentes. En cuanto a la información sobre el hundimiento, llama la atención en primer lugar la relevancia de los técnicos, peritos y letrados que intervinieron en el juicio y en el procedimiento administrativo posterior, poniéndose de manifiesto la trascendencia que el accidente tuvo en su momento y que, sin embargo, no ha trascendido hasta nuestros días. Ejemplo de ello es el papel de Echegaray -primera figura intelectual de la época- como perito en la defensa de Ribera, de D. Melquiades Álvarez -futuro presidente del Congreso- como abogado defensor, el General Marvá -uno de los máximos exponentes del papel de los ingenieros militares en la introducción del hormigón armado en nuestro país-, que presidiría la Comisión encargada del peritaje por parte del juzgado, o las opiniones de reconocidas personalidades internacionales del "nuevo" material como el Dr. von Emperger o Hennebique. Pero lo más relevante de dicha información es la falta de uniformidad sobre lo que pudo ocasionar el hundimiento: fallos en los materiales, durante la construcción, defectos en el diseño de la estructura, la realización de unas pruebas de carga cuando se concluyó ésta, etc. Pero la que durante el juicio y en los Informes posteriores se impuso como causa del fallo de la estructura fue su dilatación como consecuencia de las altas temperaturas que se produjeron aquella primavera. Y ello a pesar de que el hundimiento ocurrió a las 7 de la mañana... Con base en esta información se ha analizado el comportamiento estructural de la cubierta, permitiendo evaluar el papel que diversos factores pudieron tener en el inicio del hundimiento y en su extensión a toda la superficie construida, concluyéndose así cuáles fueron las causas del siniestro. De los resultados obtenidos se presta especial atención a las enseñanzas que se desprenden de la ocurrencia del hundimiento, enfatizándose en la relevancia de la historia -y en particular de los casos históricos de error- para la formación continua que debe existir en la Ingeniería. En el caso del hundimiento del Tercer Depósito algunas de estas "enseñanzas" son de plena actualidad, tales como la importancia de los detalles constructivos en la "robustez" de la estructuras, el diseño de estructuras "integrales" o la vigilancia del proceso constructivo. Por último, la investigación ha servido para recuperar, una vez más, la figura de D. José Eugenio Ribera, cuyo papel en la introducción del hormigón armado en España fue decisivo. En la obra del Tercer Depósito se arriesgó demasiado, y provocó un desastre que aceleró la transición hacia una nueva etapa en el hormigón estructural al abrigo de un mayor conocimiento científico y de las primeras normativas. También en esta etapa sería protagonista. This dissertation analyses the cause of the collapse of the 4th compartment of the 3th Reservoir of Canal de Isabel II in Madrid. It happened in 1905, on April 8th, being one of the most disastrous accidents occurred in the history of Spanish construction: 30 people died and 60 were injured. The design and construction supervision were carried out by D. José Eugenio Ribera, one of the main figures in Civil Engineering of our country, whose career could have been destroyed as a result of this accident. Since it occurred more than 100 years ago, the investigation started by compiling information about the structure`s design and construction, followed by reviewing the available information about the accident. With regard to the construction, it is interesting to point out its daring structural configuration. It covered a huge area of 74.000 m2 with a series of reinforced concrete vaults with a thickness of not more than 5 cm, a 6 m span and a rise of 1/10th. In turn, these vaults were supported by frames composed of very slender 0,25 m x 0,25 m columns with a height of 8 m. It is noteworthy that this took place in a time when the technology and knowledge about this "new" material was largely based on patents. In relation to the information about the collapse, its significance is shown by the important experts and lawyers that were involved in the trial and the subsequent administrative procedure. For example, Echegaray -the most important intellectual of that time- defended Ribera, Melquiades Álvarez –the future president of the Congress- was his lawyer, and General Marvá -who represented the important role of the military engineers in the introduction of reinforced concrete in our country-, led the Commission that was put in charge by the judge of the root cause analysis. In addition, the matter caught the interest of renowned foreigners like Dr. von Emperger or Hennebique and their opinions had a great influence. Nonetheless, this structural failure is unknown to most of today’s engineers. However, what is most surprising are the different causes that were claimed to lie at the root of the disaster: material defects, construction flaws, errors in the design, load tests performed after the structure was finished, etc. The final cause that was put forth during the trial and in the following reports was attributed to the dilatation of the roof due to the high temperatures that spring, albeit the collapse occurred at 7 AM... Based on this information the structural behaviour of the roof has been analysed, which allowed identifying the causes that could have provoked the initial failure and those that could have led to the global collapse. Lessons have been learned from these results, which points out the relevance of history -and in particular, of examples gone wrong- for the continuous education that should exist in engineering. In the case of the 3th Reservoir some of these lessons are still relevant during the present time, like the importance of detailing in "robustness", the design of "integral" structures or the due consideration of construction methods. Finally, the investigation has revived, once again, the figure of D. José Eugenio Ribera, whose role in the introduction of reinforced concrete in Spain was crucial. With the construction of the 3th Reservoir he took too much risk and caused a disaster that accelerated the transition to a new era in structural concrete based on greater scientific knowledge and the first codes. In this new period he would also play a major role.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Parents caring for a child with a life threatening or life limiting illness experience a protracted and largely unknown journey, as they and their child oscillate somewhere between life and death. Using an interpretive qualitative approach, interviews were conducted with parents (n = 25) of children who had died. Findings reveal parents’ experiences to be characterised by personal disorder and transformation as well as social marginalisation and disconnection. As such they confirm the validity of understanding these experiences as, fundamentally, one of liminality, in terms of both individual and collective response. In dissecting two inter-related dimensions of liminality, an underlying tension between how transition is subjectively experienced and how it is socially regulated is exposed. In particular, a structural failure to recognise the chronic nature of felt liminality can impede parents’ effective transition.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Granite submitted to high temperatures may lead to the loss of aesthetic values even before structural damage is caused. Thirteen granitoids were exposed to target temperatures, 200 °C, 400 °C, 600 °C, 800 °C and 1000 °C. Damage characterisation, including roughness, colour and oxidation of chromogen elements by means of X-ray photoelectron spectroscopy (XPS) was assessed. Altered granitoids are more resistant to structural failure but redden rapidly. Black mica-rich granitoids turn into yellow with a maximum at 800 °C. Alkali feldspar-rich granitoids redden progressively due to iron oxidation. Roughness varies progressively in mica-rich granitoids, while in mica-poor granitoids, an increase in roughness precedes catastrophic failure.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Résumé : Cette juxtaposition de matériaux solides -blocs, pierres ou briques,...- liés ou non entre eux que nous appelons maçonnerie ne se comporte pas très bien vis-à-vis des forces latérales, surtout si elle n’a pas été réalisée suivant les normes parasismiques ou de façon adéquate. Cette vulnérabilité (glissement, cisaillement, déchirure en flexion, ou tout autre) vient souvent du fait même de ce processus d’empilement, des problèmes d’interaction avec le reste de la structure et aussi à cause des caractéristiques mécaniques peu fiables de certains éléments utilisés. Malgré cette défaillance structurale, la maçonnerie est encore utilisée aujourd’hui grâce à son côté traditionnel, sa facilité de mise en œuvre et son coût d’utilisation peu élevé. Depuis quelques années, la maçonnerie s’est enrichie de documents qui ont été publiés par divers chercheurs dans le but d’une meilleure compréhension des caractéristiques mécaniques des éléments et aussi, et surtout, des mécanismes de rupture des murs de maçonnerie pour une meilleure réponse face aux sollicitations sismiques. Beaucoup de programmes expérimentaux ont alors été effectués et tant d’autres sont encore nécessaires. Et c’est dans ce contexte que cette recherche a été conduite. Elle présentera, entre autres, le comportement sous charges latérales d’un mur en maçonnerie armée entièrement rempli de coulis. Ce projet de recherche fait partie d’un programme plus large visant à une meilleure connaissance du comportement sismique de la maçonnerie pour une amélioration des techniques de construction et de réparation des ouvrages en maçonnerie.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Carbon Fiber Reinforced Polymers (CFRPs) are well renowned for their excellent mechanical properties, superior strength-to-weight characteristics, low thermal expansion coefficient, and fatigue resistance over any conventional polymer or metal. Due to the high stiffness of carbon fibers and thermosetting matrix, CFRP laminates may display some drawbacks, limiting their use in specific applications. Indeed, the overall laminate stiffness may lead to structural problems arising from their laminar structure, which makes them susceptible to structural failure by delamination. Moreover, such stiffness given by the constituents makes them poor at damping vibration, making the component more sensitive to noise and leading, at times, to delamination triggering. Nanofibrous mat interleaving is a smart way to increase the interlaminar fracture toughness: the use of thermoplastic polymers, such as poly(ε- caprolactone) (PCL) and polyamides (Nylons), as nonwovens are common and well established. Here, in this PhD thesis, a new method for the production of rubber-rich nanofibrous mats is presented. The use of rubbery nanofibers blended with PCL, widely reported in the literature, was used as matrix tougheners, processing DCB test results by evaluating Acoustic Emissions (AE). Moreover, water-soluble electrospun polyethylene oxide (PEO) nanofibers were proposed as an innovative method for reinforcing layers and hindering delamination in epoxy-based CFRP laminates. A nano-modified CFRP was then aged in water for 1 month and its delamination behaviour compared with the ones of the commercial laminate. A comprehensive study on the use of nanofibers with high rubber content, blended with a crystalline counterpart, as enhancers of the interlaminar properties were then investigated. Finally, PEO, PCL, and Nylon 66 nanofibers, plain or reinforced with Graphene (G), were integrated into epoxy-matrix CFRP to evaluate the effect of polymers and polymers + G on the laminate mechanical properties.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In 1903, the eastern slope of Turtle Mountain (Alberta) was affected by a 30 M m3-rockslide named Frank Slide that resulted in more than 70 casualties. Assuming that the main discontinuity sets, including bedding, control part of the slope morphology, the structural features of Turtle Mountain were investigated using a digital elevation model (DEM). Using new landscape analysis techniques, we have identified three main joint and fault sets. These results are in agreement with those sets identified through field observations. Landscape analysis techniques, using a DEM, confirm and refine the most recent geology model of the Frank Slide. The rockslide was initiated along bedding and a fault at the base of the slope and propagated up slope by a regressive process following a surface composed of pre-existing discontinuities. The DEM analysis also permits the identification of important geological structures along the 1903 slide scar. Based on the so called Sloping Local Base Level (SLBL) an estimation was made of the present unstable volumes in the main scar delimited by the cracks, and around the south area of the scar (South Peak). The SLBL is a method permitting a geometric interpretation of the failure surface based on a DEM. Finally we propose a failure mechanism permitting the progressive failure of the rock mass that considers gentle dipping wedges (30°). The prisms or wedges defined by two discontinuity sets permit the creation of a failure surface by progressive failure. Such structures are more commonly observed in recent rockslides. This method is efficient and is recommended as a preliminary analysis prior to field investigation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

his paper proposes a structural investigation of the Turtle Mountain anticline (Alberta, Canada) to better understand the role of the different tectonic features on the development of both local and large scale rock slope instabilities occurring in Turtle Mountain. The study area is investigated by combining remote methods with detailed field surveys. In particular, the benefit of Terrestrial Laser Scanning for ductile and brittle tectonic structure interpretations is illustrated. The proposed tectonic interpretation allows the characterization of the fracturing pattern, the fold geometry and the role of these tectonic features in rock slope instability development. Ten discontinuity sets are identified in the study area, their local variations permitting the differentiation of the study zone into 20 homogenous structural domains. The anticline is described as an eastern verging fold that displays considerable geometry differences along its axis and developed by both flexural slip and tangential longitudinal strain folding mechanisms. Moreover, the origins of the discontinuity sets are determined according to the tectonic phases affecting the region (pre-folding, folding, post-folding). The localization and interpretation of kinematics of the different instabilities revealed the importance of considering the discrete brittle planes of weakness, which largely control the kinematic release of the local instabilities, and also the rock mass damage induced by large tectonic structures (fold hinge, thrust).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The relevance of the relationship between cardiac disease and depressive symptoms is well established. White matter hyperintensity, a bright signal area in the brain on T2-weighted magnetic resonance imaging scans, has been separately associated with cardiovascular risk factors, cardiac disease and late-life depression. However, no study has directly investigated the association between heart failure, major depressive symptoms and the presence of hyperintensities. Using a visual assessment scale, we have investigated the frequency and severity of white matter hyperintensities identified by magnetic resonance imaging in eight patients with late-life depression and heart failure, ten patients with heart failure without depression, and fourteen healthy elderly volunteers. Since the frontal lobe has been the proposed site for the preferential location of white matter hyperintensities in patients with late-life depression, we focused our investigation specifically on this brain region. Although there were no significant group differences in white matter hyperintensities in the frontal region, a significant direct correlation emerged between the severity of frontal periventricular white matter hyperintensity and scores on the Hamilton scale for depression in the group with heart failure and depression (P = 0.016, controlled for the confounding influence of age). There were no significant findings in any other areas of the brain. This pattern of results adds support to a relationship between cardiovascular risk factors and depressive symptoms, and provides preliminary evidence that the presence of white matter hyperintensities specifically in frontal regions may contribute to the severity of depressive symptoms in cardiac disease.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents the results of cyclic loading tests on two large-scale reinforced concrete structural walls that were conducted at Purdue University. One of the walls had confinement reinforcement meeting ACI-318-11 requirements while the other wall did not have any confinement reinforcement. The walls were tested as part of a larger study aimed at indentifying parameters affecting failure modes observed to limit the drift capacity of structural walls in Chile during the Maule Earthquake of 2010. These failure modes include out-of-plane buckling (of the wall rather tan individual reinforcing bars), compression failure, and bond failure. This paper discusses the effects of confinement on failure mode. Distributions of unit strain and curvature obtained with a dense array of non-contact coordinate-tracking targets are also presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The role of exercise training (ET) on cardiac renin-angiotensin system (RAS) was investigated in 3-5 month-old mice lacking alpha(2A-) and alpha(2C-)adrenoceptors (alpha(2A)/alpha(2C)ARKO) that present heart failure (HF) and wild type control (WT). ET consisted of 8-week running sessions of 60 min, 5 days/week. In addition, exercise tolerance, cardiac structural and function analysis were made. At 3 months, fractional shortening and exercise tolerance were similar between groups. At 5 months, alpha(2A)/alpha(2C)ARKO mice displayed ventricular dysfunction and fibrosis associated with increased cardiac angiotensin (Ang) II levels (2.9-fold) and increased local angiotensin-converting enzyme activity (ACE 18%). ET decreased alpha(2A)/alpha(2C)ARKO cardiac Ang II levels and ACE activity to age-matched untrained WT mice levels while increased ACE2 expression and prevented exercise intolerance and ventricular dysfunction with little impact on cardiac remodeling. Altogether, these data provide evidence that reduced cardiac RAS explains, at least in part, the beneficial effects of ET on cardiac function in a genetic model of HF.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Sympathetic hyperactivity (SH) and renin angiotensin system (RAS) activation are commonly associated with heart failure (HF), even though the relative contribution of these factors to the cardiac derangement is less understood. The role of SH on RAS components and its consequences for the HF were investigated in mice lacking alpha(2A) and alpha(2C) adrenoceptor knockout (alpha(2A)/alpha(2C) ARKO) that present SH with evidence of HF by 7 mo of age. Cardiac and systemic RAS components and plasma norepinephrine (PN) levels were evaluated in male adult mice at 3 and 7 mo of age. In addition, cardiac morphometric analysis, collagen content, exercise tolerance, and hemodynamic assessments were made. At 3 mo, alpha(2A)/alpha(2C)ARKO mice showed no signs of HF, while displaying elevated PN, activation of local and systemic RAS components, and increased cardiomyocyte width (16%) compared with wild-type mice (WT). In contrast, at 7 mo, alpha(2A)/alpha(2C)ARKO mice presented clear signs of HF accompanied only by cardiac activation of angiotensinogen and ANG II levels and increased collagen content (twofold). Consistent with this local activation of RAS, 8 wk of ANG II AT(1) receptor blocker treatment restored cardiac structure and function comparable to the WT. Collectively, these data provide direct evidence that cardiac RAS activation plays a major role underlying the structural and functional abnormalities associated with a genetic SH-induced HF in mice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work presents a comparative analysis about the behaviour of pile caps supported by 3 piles subjected to axial loading. Piles with 20 cm and 30 cm diameters were analysed. The main reinforcement was maintained in all the specimens, however, the arrangement of the secondary reinforcement varied. The main reinforcement consisted of steel bars connecting the piles. The secondary reinforcement was made up of: (a) bars going through the piles and through the projection of the column, (b) bars forming a network, and (c) vertical and horizontal stirrups. The main objective was the observation of the pile cap behaviour regarding the cracks and the modes of rupture. The real scale specimens were subjected to experimental tests until failure by rupture. Instruments were placed with the aim to obtain the displacement of the bases, the strains in the main and secondary reinforcement bars, in the compression struts, in the lower and upper nodal zones and in the sides of the caps. None of the caps reached failure by rupture with a load less than 1.12 times the theoretical load. The specimens ruptured due to the cracking of the compression strut and/or the yielding of the reinforcement bars in one direction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conventional procedures used to assess the integrity of corroded piping systems with axial defects generally employ simplified failure criteria based upon a plastic collapse failure mechanism incorporating the tensile properties of the pipe material. These methods establish acceptance criteria for defects based on limited experimental data for low strength structural steels which do not necessarily address specific requirements for the high grade steels currently used. For these cases, failure assessments may be overly conservative or provide significant scatter in their predictions, which lead to unnecessary repair or replacement of in-service pipelines. Motivated by these observations, this study examines the applicability of a stress-based criterion based upon plastic instability analysis to predict the failure pressure of corroded pipelines with axial defects. A central focus is to gain additional insight into effects of defect geometry and material properties on the attainment of a local limit load to support the development of stress-based burst strength criteria. The work provides an extensive body of results which lend further support to adopt failure criteria for corroded pipelines based upon ligament instability analyses. A verification study conducted on burst testing of large-diameter pipe specimens with different defect length shows the effectiveness of a stress-based criterion using local ligament instability in burst pressure predictions, even though the adopted burst criterion exhibits a potential dependence on defect geometry and possibly on material`s strain hardening capacity. Overall, the results presented here suggests that use of stress-based criteria based upon plastic instability analysis of the defect ligament is a valid engineering tool for integrity assessments of pipelines with axial corroded defects. (C) 2008 Elsevier Ltd. All rights reserved.