422 resultados para Stripping


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The increasing use of seal coats for surface restoration and the concurrent increase in failures of such treatments prompted the current research. Field observations indicated that certain aggregate types seemed to be more susceptible to failure, including stripping and disintegration. The research was thus designed to try to identify those aggregate types which would perform satisfactorily under normal conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The complexing capacity of synthetic (0.011 M tartrate in 13.5% ethanol) and real wine (Raimat Abadia) in titrations with added total Zn concentrations up to 0.03 M has been determined following the free Zn concentrations with AGNES (absence of gradients and Nernstian equilibrium stripping) technique. A correction to find the preconcentration factor or gain (Y1) really applied at each one of the ionic strengths reached due to Zn additions along the titration has been applied. The standard implementation of AGNES to real wine led to the observation of two anomalous behaviors: (a) an increasingly negative current in the deposition stage (labeled as “HER” effect) and (b) a minimum in the currents of the stripping stage plot (labeled as the “dip” effect). A practical strategy to apply AGNES avoiding the dip effect has been developed to quantify properly free Zn concentrations. The van den Berg–Ružic–Lee linearization method (assuming the existence of just 1:1 complexes) has been adapted to consider the dilution effect and the ionic strength changes. Aggregated stability constants and total ligand concentrations have been calculated from synthetic and wine titration data. The found complexing capacity in the studied wine (cT,L = 0.0179 ± 0.0007 M) indicates the contribution of ligands other than tartrate (which is confirmed to be the main one).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

No processo de extração do óleo de soja forma-se a Miscela, que é uma mistura de óleo e hexano. O processo de separação destes dois componentes é denominado de Destilação da Miscela. Esta é composta basicamente da operação de evaporação e da operação de stripping do hexano. Neste trabalho, desenvolveu-se uma modelagem matemática para o stripping do hexano. O modelo é baseado em balanços de massa e energia e em relações de equilíbrio; e, a sua validação foi feita comparando-se os resultados obtidos com os dados operacionais da indústria da COAMO (Cooperativa Agrícola Mouraoense). Em seguida, com o modelo elaborado, fez-se as simulações para estudar: as influências da concentração da alimentação e do modo de injeção de vapor direto nos resultados operacionais do stripper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this Master’s thesis is to find a method for classifying spare part criticality in the case company. Several approaches exist for criticality classification of spare parts. The practical problem in this thesis is the lack of a generic analysis method for classifying spare parts of proprietary equipment of the case company. In order to find a classification method, a literature review of various analysis methods is required. The requirements of the case company also have to be recognized. This is achieved by consulting professionals in the company. The literature review states that the analytic hierarchy process (AHP) combined with decision tree models is a common method for classifying spare parts in academic literature. Most of the literature discusses spare part criticality in stock holding perspective. This is relevant perspective also for a customer orientated original equipment manufacturer (OEM), as the case company. A decision tree model is developed for classifying spare parts. The decision tree classifies spare parts into five criticality classes according to five criteria. The criteria are: safety risk, availability risk, functional criticality, predictability of failure and probability of failure. The criticality classes describe the level of criticality from non-critical to highly critical. The method is verified for classifying spare parts of a full deposit stripping machine. The classification can be utilized as a generic model for recognizing critical spare parts of other similar equipment, according to which spare part recommendations can be created. Purchase price of an item and equipment criticality were found to have no effect on spare part criticality in this context. Decision tree is recognized as the most suitable method for classifying spare part criticality in the company.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using the technique of liquid crystal templating a rotating disc electrode (RDE) was modified with a high surface area mesoporous platinum film. The surface area of the electrode was characterised by acid voltammetry, and found to be very high (ca. 86 cm(2)). Acid characterisation of the electrode produced distorted voltammograms was interpreted as being due to the extremely large surface area which produced a combination of effects such as localised pH change within the pore environment and also ohmic drop effects. Acid voltammetry in the presence of two different types of surfactant, namely Tween 20 and Triton X-100, suggested antifouling properties associated with the mesoporous deposit. Further analysis of the modified electrode using a redox couple in solution showed typical RDE behaviour although extra capacitive currents were observed due to the large surface area of the electrode. The phenomenon of underpotential deposition was exploited for the purpose of anodic stripping voltammetry and results were compared with data collected for microelectrodes. Underpotential deposition of metal ions at the mesoporous RDE was found to be similar to that at conventional platinum electrodes and mesoporous microelectrodes although the rate of surface coverage was found to be slower at a mesoporous RDE. It was found that a mesoporous RDE forms a suitable system for quantification of silver ions in solution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using the technique of liquid crystal templating a series of high surface area mesoporous platinum microelectrodes was fabricated. The underpotential deposition of metal ions at such electrodes was found to be similar to that at conventional platinum electrodes. The phenomena of underpotential deposition, in combination with the intrinsic properties of mesoporous microelectrodes (i.e. a high surface area and efficient mass transport) was exploited for the purpose of anodic stripping voltammetry. In particular the underpotential deposition of Ag+, Pb2+ and Cu2+ ions was investigated and it was found that mesoporous microelectrodes were able to quantify the concentration of ions in solution down to the ppb range. The overall behaviour of the mesoporous electrodes was found to be superior to that of conventional microelectrodes and the effects of interference by surfactants were minimal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Successful coupling of electrochemical preconcentration (EPC) to capillary electrophoresis (CE) with contactless conductivity detection (C(4)D) is reported for the first time. The EPC-CE interface comprises a dual glassy carbon electrode (GCE) block, a spacer and an upper block with flow inlet and outlet, pseudo-reference electrode and a fitting for the CE silica column, consisting of an orifice perpendicular to the surface of a glassy carbon electrode with a bushing inside to ensure a tight press fit. The end of the capillary in contact with the GCE is slant polished, thus defining a reproducible distance from the electrode surface to the column bore. First results with EPC-CE-C(4)D are very promising, as revealed by enrichment factors of two orders of magnitude for Tl, Cu, Pb and Cd ion peak area signals. Detection limits for 10 min deposition time fall around 20 nmol L(-1) with linear calibration curves over a wide range. Besides preconcentration, easy matrix exchange between accumulation and stripping/injection favors procedures like sample cleanup and optimization of pH, ionic strength and complexing power. This was demonstrated for highly saline samples by using a low conductivity buffer for stripping/injection to improve separation and promote field-enhanced sample stacking during electromigration along the capillary. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the development and evaluation of a sequential injection method to automate the determination of methyl parathion by square wave adsorptive cathodic stripping voltammetry exploiting the concept of monosegmented flow analysis to perform in-line sample conditioning and standard addition. Accumulation and stripping steps are made in the sample medium conditioned with 40 mmol L-1 Britton-Robinson buffer (pH 10) in 0.25 mol L-1 NaNO3. The homogenized mixture is injected at a flow rate of 10 mu Ls(-1) toward the flow cell, which is adapted to the capillary of a hanging drop mercury electrode. After a suitable deposition time, the flow is stopped and the potential is scanned from -0.3 to -1.0 V versus Ag/AgCl at frequency of 250 Hz and pulse height of 25 mV The linear dynamic range is observed for methyl parathion concentrations between 0.010 and 0.50 mgL(-1), with detection and quantification limits of 2 and 7 mu gL(-1), respectively. The sampling throughput is 25 h(-1) if the in line standard addition and sample conditioning protocols are followed, but this frequency can be increased up to 61 h(-1) if the sample is conditioned off-line and quantified using an external calibration curve. The method was applied for determination of methyl parathion in spiked water samples and the accuracy was evaluated either by comparison to high performance liquid chromatography with UV detection, or by the recovery percentages. Although no evidences of statistically significant differences were observed between the expected and obtained concentrations, because of the susceptibility of the method to interference by other pesticides (e.g., parathion, dichlorvos) and natural organic matter (e.g., fulvic and humic acids), isolation of the analyte may be required when more complex sample matrices are encountered. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the automation of a fully electrochemical system for preconcentration, cleanup, separation and detection, comprising the hyphenation of a thin layer electrochemical flow cell with CE coupled with contactless conductivity detection (CE-C(4)D). Traces of heavy metal ions were extracted from the pulsed-flowing sample and accumulated on a glassy carbon working electrode by electroreduction for some minutes. Anodic stripping of the accumulated metals was synchronized with hydrodynamic injection into the capillary. The effect of the angle of the slant polished tip of the CE capillary and its orientation against the working electrode in the electrochemical preconcentration (EPC) flow cell and of the accumulation time were studied, aiming at maximum CE-C(4)D signal enhancement. After 6 min of EPC, enhancement factors close to 50 times were obtained for thallium, lead, cadmium and copper ions, and about 16 for zinc ions. Limits of detection below 25 nmol/L were estimated for all target analytes but zinc. A second separation dimension was added to the CE separation capabilities by staircase scanning of the potentiostatic deposition and/or stripping potentials of metal ions, as implemented with the EPC-CE-C(4)D flow system. A matrix exchange between the deposition and stripping steps, highly valuable for sample cleanup, can be straightforwardly programmed with the multi-pumping flow management system. The automated simultaneous determination of the traces of five accumulable heavy metals together with four non-accumulated alkaline and alkaline earth metals in a single run was demonstrated, to highlight the potentiality of the system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development and application of a functionalized carbon nanotubes paste electrode (CNPE) modified with crosslinked chitosan for determination of Cu(II) in industrial wastewater, natural water and human urine samples by linear scan anodic stripping voltammetry (LSASV) are described. Different electrodes were constructed using chitosan and chitosan crosslinked with glutaraldehyde (CTS-GA) and epichlorohydrin (CTS-ECH). The best voltammetric response for Cu(II) was obtained with a paste composition of 65% (m/m) of functionalized carbon nanotubes, 15% (m/m) of CTS-ECH, and 20% (m/m) of mineral oil using a solution of 0.05 mol L(-1) KNO(3) with pH adjusted to 2.25 with HNO(3), an accumulation potential of 0.3V vs. Ag/AgCl (3.0 mol L(-1) KCl) for 300 s and a scan rate of 100 mV s(-1). Under these optimal experimental conditions, the voltammetric response was linearly dependent on the Cu(II) concentration in the range from 7.90 x 10(-8) to 1.60 x 10(-5) mol L(-1) with a detection limit of 1.00 x 10(-8) mol L(-1). The samples analyses were evaluated using the proposed sensor and a good recovery of Cu(II) was obtained with results in the range from 98.0% to 104%. The analysis of industrial wastewater, natural water and human urine samples obtained using the proposed CNPE modified with CTS-ECH electrode and those obtained using a comparative method are in agreement at the 95% confidence level. (C) 2009 Elsevier B. V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this photo, members of the Stripping Class in the Lithography Department of the New York Trade School are shown at work. Original caption reads, "Members of the Stripping Class. Equipment loaned by the United States Printing & Litho. Company and Local #1." Black and white photograph.