977 resultados para Standard Mouse Neutralization Test


Relevância:

100.00% 100.00%

Publicador:

Resumo:

An indirect ELISA for determination of post-vaccination rabies antibody was applied. Purified rabies virus was used as antigen to coat plates, and staphylococcal protein A linked with horseradish peroxidase was used for detecting IgG antibody in human sera. Sera from humans, vaccinated with cell-culture vaccine or suckling-mouse-brain vaccine, were examined. ELISA results were compared to those obtained from the virus neutralization test. The mean and standard deviation of OD were determined for 126 negative sera (pre-vaccination) and for 73 sera from vaccinated persons showing antibody titers lower than 0.5 IU/ml. Results were defined as ELISA -positive, -negative or -doubtful. Establishment of a doubtful region reduced the number of sera otherwise classified as positive (false-positive sera). In this way, the sensitivity, specificity and agreement values were respectively 87.5%, 92.4% and 88.5%. No significant differences were observed in these values when the group vaccinated with cell-culture vaccine and the group vaccinated with suckling-mouse-brain vaccine were compared. It was shown that much of the disagreement between the values obtained by neutralization test and ELISA occurred in sera obtained at the beginning of the immunization process, and was probably due to the presence of IgM in the serum samples, detected only by the former test. This ELISA method can be used as a screening test in rabies laboratories regardless of the kind of vaccine used for immunization.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

During an epidemiological survey of acute respiratory infection in Rio de Janeiro, among 208 adenovirus isolates, we found two strains that we were not able, by a standard neutralization procedure, to distinguish between type 3 or 7. However, DNA restriction pattern for the two strains with different enzymes were analyzed and showed a typical Ad3h profile. Using a cross-neutralization test in which both Ad3p and Ad7p antisera were used in different concentration against 100 TCID50 of each adenovirus standard and both isolates, we were able to confirm that the two isolates belong to serotype 3. An hemagglutination inhibition test also corroborated the identification of both strains as adenovirus type 3. Comparing Ad3h and Ad3p genome, we observed 16 different restriction enzyme sites, three of which were located in genomic regions encoding polypeptides involved in neutralization sites

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rabies is a neurotropic disease that is often lethal. The early diagnosis of rabies infection is important and requires methods that allow for the isolation of the virus from animals and humans. The present study compared a modified shell vial (MSV) procedure using 24-well tissue culture plates with the mouse inoculation test (MIT), which is considered the gold standard for rabies virus isolation. Thirty brain samples (25 positive and 5 negative by the fluorescent antibody test) obtained from different animal species at the National Institute of Hygiene Rafael Rangel in Caracas, Venezuela, were studied by the MIT and MSV assays. Nine samples (36%) were positive at 24 h, 10 (40%) were positive at 48 h and six (24%) were positive at 72 h by the MSV assay. With the MIT assay, 76% were positive at six days post inoculation and 12% were positive at 12 and 18 days post inoculation. One sample that was negative according to the MSV assay was positive with MIT on the 12th day. The MSV procedure exhibited a sensitivity of 96.2%, a specificity of 100%, a positive predictive value of 100% and a negative predictive value 80%. This procedure allowed for rapid rabies virus detection. MIT can be employed as an alternative method in laboratories without tissue culture facilities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A remarkable feature of the carcinogenicity of inorganic arsenic is that while human exposures to high concentrations of inorganic arsenic in drinking water are associated with increases in skin, lung, and bladder cancer, inorganic arsenic has not typically caused tumors in standard laboratory animal test protocols. Inorganic arsenic administered for periods of up to 2 yr to various strains of laboratory mice, including the Swiss CD-1, Swiss CR:NIH(S), C57Bl/6p53(+/-), and C57Bl/6p53(+/+), has not resulted in significant increases in tumor incidence. However, Ng et al. (1999) have reported a 40% tumor incidence in C57Bl/6J mice exposed to arsenic in their drinking water throughout their lifetime, with no tumors reported in controls. In order to investigate the potential role of tissue dosimetry in differential susceptibility to arsenic carcinogenicity, a physiologically based pharmacokinetic (PBPK) model for inorganic arsenic in the rat, hamster, monkey, and human (Mann et al., 1996a, 1996b) was extended to describe the kinetics in the mouse. The PBPK model was parameterized in the mouse using published data from acute exposures of B6C3F1 mice to arsenate, arsenite, monomethylarsonic acid (MMA), and dimethylarsinic acid (DMA) and validated using data from acute exposures of C57Black mice. Predictions of the acute model were then compared with data from chronic exposures. There was no evidence of changes in the apparent volume of distribution or in the tissue-plasma concentration ratios between acute and chronic exposure that might support the possibility of inducible arsenite efflux. The PBPK model was also used to project tissue dosimetry in the C57Bl/6J study, in comparison with tissue levels in studies having shorter duration but higher arsenic treatment concentrations. The model evaluation indicates that pharmacokinetic factors do not provide an explanation for the difference in outcomes across the various mouse bioassays. Other possible explanations may relate to strain-specific differences, or to the different durations of dosing in each of the mouse studies, given the evidence that inorganic arsenic is likely to be active in the later stages of the carcinogenic process. [Authors]

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The human anti-rabies pre-exposure treatment currently used in Brazil, employing a 1-ml dose of suckling mouse brain vaccine (SMBV) administered on days 0, 2, 4 and 28, was compared to an alternative treatment with two 1 ml-doses on day 0, and one 1 ml-dose injected on days 7 and 21. The latter induced higher virus-neutralizing antibody (VNA) titers on day 21. Both Brazilian rabies vaccines produced with PV or CVS rabies virus strains were tested. Two additional volunteer vaccinee groups, receiving the pre-exposure and the abbreviated post-exposure schedules recommended by the WHO using cell-culture vaccine (CCV) produced with PM rabies virus strain, were included as reference. The VNA were measured against both PV and CVS strains on days 21, 42 and 180 by the cell-culture neutralization microtest. The PV-SMBV elicited higher seroconversion rates and VNA by day 21 than the CVS-SMBV. Both, however, failed to induce a long-term immunity, since VNA titers were <0.5 IU/ml on day 180, regardless of the schedule used. Cell-culture vaccine always elicited very high VNA on all days of collection. When serum samples from people receiving mouse brain tissue were titrated against the PV and CVS strains, the VNA obtained were similar, regardless of the vaccinal strain and the virus used in the neutralization test. These results contrast with those obtained with sera from people receiving PM-CCV, whose VNA were significantly higher when tested against the CVS strain.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Previous findings point to the involvement of the dorsal raphe nucleus (DRN) and dorsal periaqueductal gray (dPAG) serotonergic receptors in the mediation of defensive responses that are associated with specific subtypes of anxiety disorders. These studies have mostly been conducted with rats tested in the elevated T-maze, an experimental model of anxiety that was developed to allow the measurement, in the same animal, of two behaviors mentioned: inhibitory avoidance and one-way escape. Such behavioral responses have been respectively related to generalized anxiety disorder (GAD) and panic disorder (PD). In order to assess the generality of these findings, in the current study we investigated the effects of the injection of 5-HT-related drugs into the DRN and dPAG of another rodent species, mouse, on the mouse defense test battery (MDTB), a test of a range of defensive behaviors to an unconditioned threat, a predator. Male CD-1 mice were tested in the MDTB after intra-DRN administration of the 5-HT(1A) receptor antagonist WAY-100635 or after intra-dPAG injection of two serotonergic agonists, the 5-HT1A receptor agonist 8-OH-DPAT and the 5-HT(2A/2C) receptor agonist DOI. Intra-DRN injection of WAY-100635 did not change behavioral responses of mice confronted with a rat in the MDTB. In the dPAG, both 8-OH-DPAT and DOI consistently impaired mouse escape behavior assessed in the MDTB. Intra-dPAG infusion of 8-OH-DPAT also decreased measures of mouse risk assessment in the rat exposure test. In conclusion, the current findings are in partial agreement with previous results obtained with rats tested in the elevated T-maze. Although there is a high level of similarity between the behavioral effects obtained in rats (elevated T-maze) and mice (MDTB and RET) with the infusion of 5-HT agonists into the dPAG, the same is not true regarding the effects of blockade of DRN 5-HT(1A) receptors in these rodent species. These data suggest that there may be differences between mice and rats regarding the involvement of the DRN in the mediation of defensive behaviors. (C) 2010 Elsevier B.V. and ECNP. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives Low doses of ACTH [1-24] (0.1, 0.5 and 1.0 mug per 1.73 m(2)) may provide a more physiological level of adrenal stimulation than the standard 250 mug test, but not all studies have concluded that the 1.0 fig is a more sensitive screening test for central hypoadrenalism. Eight-hour infusions of high dose ACTH [1-24] have also been suggested as a means of assessing the adrenals' capacity for sustained cortisol secretion. In this study, we compared the diagnostic accuracy of three low dose ACTH tests (LDTs) and the 8-h infusion with the standard 250 jig test (HDT) and the insulin hypoglycaemia test (IHT) in patients with hypothalamic-pituitary disease. Subjects and design Three groups of subjects were studied. A healthy control group (group 1, n=9) and 33 patients with known hypothalamic or pituitary disease who were divided into group 2 (n=12, underwent IHT) and group 3 (n=21, IHT contraindicated). Six different tests were performed: a standard IHT (0.15 U/kg soluble insulin); a 60-minute 250 mug HDT; three different LDTs using 0.1 mug, 0.5 mug and 1.0 mug (all per 1.73 m(2)); and an 8-h infusion test (250 mug ACTH [1-24] at a constant rate over 8 h). Results Nine out of the 12 patients in group 2 failed the IHT. Three out of 12 patients from group 2 who clearly passed the IHT, also passed all the ACTH [1-24] stimulation tests. Seven of the 9 patients who failed the lHT, failed by a clear margin (peak cortisol

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the present work the immune adherence hemagglutination test (IAHA) was standardized in a simplified procedure. This test showed good reproducibility, better than the classical mice serum neutralization test (SN). The tests showed high correlation degree: high titers in one test corresponded to high titers in the other one, and the same occured with low titers. The IAHA test is extremely simple, fast to perform, and of low cost when compared to tests such as SN or indirect immunofluorescense (IIF). It also proved to be useful in less sophisticated laboratories or even as a screening test for the titration of rabies antibodies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simplified fluorescence inhibition microtest (SFIMT) was standardized for the evaluation of antirabies serum neutralizing antibodies based on the rapid fluorescent focus inhibition test (RFFIT) and the fluorescence inhibition microtest (FIMT). The simplified test showed reproductibility similar to that of the FIMT with advantages as easier executation and quicker reading. A simple pre-treatment of Brazilian microplates produced for immune enzymatic assays (PROSIL) gave equivalent results and substantial coast reduction, in relation to imported plates (DIFCO). The simplified test can be easily implemented in less sophisticated laboratories, as alternative to the mouse serum neutralization test, still the most largely employed in Brazil, or even to others as RFFIT and FIMT.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The determination of the rabies neutralizing antibody (VNA) response after immunization against rabies is an acceptable index of the efficacy of a vaccine and a successful treatment. Several tests have been developed in attempt to improve the assessment of VNA, from mice inoculation to cell-culture fluorescence inhibition tests. All of them, however, present special difficulties in terms of reading or accuracy. The present study describes a neutralization test performed in cell-culture appraised by flow cytometry (FC). Serial dilutions of the serum samples were mixed in vitro with rabies virus before the addition of BHK-21 cells. After 24h-incubation, cells were released by trypsin treatment, fixed and permeabilized with a p-formaldehyde solution and stained with a rabies virus nucleocapsid protein-specific antibody conjugate. The percentage of virus infection inhibition caused by specific antibodies present in the serum were evaluated in a Beckton & Dickinson FACSCalibur® flow cytometer. A correlation curve between the IU/ml content and the percentage of infective inhibition was built with a reference serum and the VNA titers of serum samples were obtained by extrapolation. Titers obtained by FC and standard test showed an effective pairing results (p < 0.01), with a correlation coefficient (r) = 0.7. These results permit to envisage the FC as a suitable technique to evaluate VNA in sera from immunized animals and likely in human serum samples. Nevertheless, new studies comparing FC to gold-standard techniques are required for determining the FC values of Sensibility and Specificity .

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction Rabies is an important zoonosis that occurs in mammals, with bats acting as Lyssavirus reservoirs in urban, rural and natural areas. Rabies cases in bats have been recorded primarily in urban areas in Northwestern State of São Paulo since 1998. This study investigated the circulation of rabies virus by seeking to identify the virus in the brain in several species of bats in this region and by measuring rabies-virus neutralizing antibody levels in the hematophagous bat Desmodus rotundus. Methods From 2008 to 2012, 1,490 bat brain samples were sent to the Universidade Estadual Paulista (UNESP) Rabies Laboratory in Araçatuba, and 125 serum samples from vampire bats that were captured in this geographical region were analyzed. Results Rabies virus was detected in the brains of 26 (2%) of 1,314 non-hematophagous bats using the fluorescent antibody test (FAT) and the mouse inoculation test (MIT). None of the 176 hematophagous bat samples were positive for rabies virus when a virus detection test was utilized. Out of 125 vampire bat serum samples, 9 (7%) had levels of rabies virus neutralization antibodies (RVNAs) that were higher than 0.5IU/mL; 65% (81/125) had titers between 0.10IU/mL and 0.5IU/mL; and 28% (35/125) were negative for RVNAs using the simplified fluorescent inhibition microtest (SFIMT) in BHK21 cells. The observed positivity rate (1.7%) was higher than the average positivity rate of 1.3% that was previously found in this region. Conclusions The high percentage of vampire bats with neutralizing antibodies suggests that recent rabies virus exposure has occurred, indicating the necessity of surveillance measures in nearby regions that are at risk to avoid diffusion of the rabies virus and possible rabies occurrences.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Par le biais d'une procédure Test-Retest, la stabilité à long terme des indices standard du WISC-IV français a été évaluée. L'intervalle moyen entre les deux passations est de 2,33 ans. L'échantillon comprend 96 enfants « tout venant » âgés de huit à 12 ans. Les comparaisons entre les moyennes des deux passations ne montrent pas de différence significative pour indice de compréhension verbale (ICV), indice de raisonnement perceptif (IRP), indice de mémoire de travail (IMT), indice d'aptitude générale (IAG) et QIT. Au niveau interindividuel, les coefficients de corrélations témoignent d'une bonne stabilité à long terme pour ICV, IAG et QIT (allant de 0,81 à 0,82). Une analyse des différences de performances entre les deux passations indique une stabilité intra-individuelle satisfaisante pour IMT et IAG. Seul IAG présente donc une stabilité à long terme satisfaisante au niveau inter- et intra-individuel. By a Test-Retest procedure, this study explores the long-term stability of the French WISC-IV index scores. The average Test-Retest interval was 2.33 years. The sample consisted of 96 non-clinical children aged between 8 and 12 years. Mean difference between the two testings was not statistically significant for VCI, PRI, WMI, GAI and FSIQ. Test-Retest reliability correlations between the two assessments are high for VCI, GAI and FSIQ (ranging from .81 to .82). An analysis of the performance differences between two assessments indicates intra-individual stability for WMI and GAI. In sum, only GAI demonstrates reliable long-term stability at an inter-and intra-individual level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The application of multivariate calibration techniques to multicomponent analysis by UV-VIS molecular absorption spectrometry is a powerful tool for simultaneous determination of several chemical species. However, when this methodology is accomplished manually, it is slow and laborious, consumes high amounts of reagents and samples, is susceptible to contaminations and presents a high operational cost. To overcome these drawbacks, a flow-batch analyser is proposed in this work. This analyser was developed for automatic preparation of standard calibration and test (or validation) mixtures. It was applied to the simultaneous determination of Cu2+, Mn2+ and Zn2+ in polyvitaminic and polymineral pharmaceutical formulations, using 4-(2-piridilazo) resorcinol as reagent and a UV-VIS spectrophotometer with a photodiode array detector. The results obtained with the proposed system are in good agreement with those obtained by flame atomic absorption spectrometry, which was employed as reference method. With the proposed analyser, the preparation of calibration and test mixtures can be accomplished about four hours, while the manual procedure requires at least two days. Moreover, it consumes smaller amounts of reagents and samples than the manual procedure. After the preparation of calibration and test mixtures, 60 samples h-1 can be carried out with the proposed flow-batch analyser.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a reappraisal of the blood clotting response (BCR) tests for anticoagulant rodenticides, and proposes a standardised methodology for identifying and quantifying physiological resistance in populations of rodent species. The standardisation is based on the International Normalised Ratio, which is standardised against a WHO international reference preparation of thromboplastin, and allows comparison of data obtained using different thromboplastin reagents. ne methodology is statistically sound, being based on the 50% response, and has been validated against the Norway rat (Rattus norvegicus) and the house mouse (Mus domesticus). Susceptibility baseline data are presented for warfarin, diphacinone, chlorophacinone and coumatetralyl against the Norway rat, and for bromadiolone, difenacoum, difethialone, flocoumafen and brodifacoum against the Norway rat and the house mouse. A 'test dose' of twice the ED50 can be used for initial identification of resistance, and will provide a similar level of information to previously published methods. Higher multiples of the ED50 can be used to assess the resistance factor, and to predict the likely impact on field control.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In order to investigate the relationship between behaviors elicited by chemical stimulation of the dorsal periaqueductal gray (dorsal PAG) and spontaneous defensive behaviors to a predator, the excitatory amino acid D,L-homocysteic acid (5 nmol in 0.1 mu l), was infused into the dorsal PAG and behavioral responses of mice were evaluated in two different situations, a rectangular novel chamber or the Mouse Defense Test Battery (MDTB) apparatus. During a 1-min period following drug infusion, more jumps were made in the chamber than in the MDTB runway but running time and distance traveled were significantly higher in the runway. Animals were subsequently tested using the standard MDTB procedure (anti-predator avoidance, chase and defensive threat/attack). No drug effects on these measures were significant. In a further test in the MDTB apparatus, the pathway of the mouse during peak locomotion response was blocked 3 times by the predator stimulus (anesthetized rat) to determine if the mouse would avoid contact. Ninety percent of D,L-homocysteic treated animals made direct contact with the stimulus (rat), indicating that D,L-homocysteic-induced running is not guided by relevant (here, threat) stimuli. These results indicate that running as opposed to jumping is the primary response in mice injected with D,L-homocysteic into the dorsal PAG when the environment enables flight. However, the lack of responsivity to the predator during peak locomotion suggests that D,L-homocysteic-stimulation into the dorsal PAG does not induce normal antipredator flight. (c) 2006 Published by Elsevier B.V.