925 resultados para Solar water heating systems
Resumo:
Emissions are an important aspect of a pellet heating system. High carbon monoxide emissions are often caused by unnecessary cycling of the burner when the burner is operated below the lowest combustion power. Combining pellet heating systems with a solar heating system can significantly reduce cycling of the pellet heater and avoid the inefficient summer operation of the pellet heater. The aim of this paper was to study CO-emissions of the different types of systems and to compare the yearly CO-emissions obtained from simulations with the yearly CO-emissions calculated based on the values that are obtained by the standard test methods. The results showed that the yearly CO-emissions obtained from the simulations are significant higher than the yearly CO-emissions calculated based on the standard test methods. It is also shown that for the studied systems the average emissions under these realistic annual conditions were greater than the limit values of two Eco-labels. Furthermore it could be seen that is possible to almost halve the CO-emission if the pellet heater is combined with a solar heating system.
Resumo:
Dynamic system test methods for heating systems were developed and applied by the institutes SERC and SP from Sweden, INES from France and SPF from Switzerland already before the MacSheep project started. These test methods followed the same principle: a complete heating system – including heat generators, storage, control etc., is installed on the test rig; the test rig software and hardware simulates and emulates the heat load for space heating and domestic hot water of a single family house, while the unit under test has to act autonomously to cover the heat demand during a representative test cycle. Within the work package 2 of the MacSheep project these similar – but different – test methods were harmonized and improved. The work undertaken includes: • Harmonization of the physical boundaries of the unit under test. • Harmonization of the boundary conditions of climate and load. • Definition of an approach to reach identical space heat load in combination with an autonomous control of the space heat distribution by the unit under test. • Derivation and validation of new six day and a twelve day test profiles for direct extrapolation of test results. The new harmonized test method combines the advantages of the different methods that existed before the MacSheep project. The new method is a benchmark test, which means that the load for space heating and domestic hot water preparation will be identical for all tested systems, and that the result is representative for the performance of the system over a whole year. Thus, no modelling and simulation of the tested system is needed in order to obtain the benchmark results for a yearly cycle. The method is thus also applicable to products for which simulation models are not available yet. Some of the advantages of the new whole system test method and performance rating compared to the testing and energy rating of single components are: • Interaction between the different components of a heating system, e.g. storage, solar collector circuit, heat pump, control, etc. are included and evaluated in this test. • Dynamic effects are included and influence the result just as they influence the annual performance in the field. • Heat losses are influencing the results in a more realistic way, since they are evaluated under "real installed" and representative part-load conditions rather than under single component steady state conditions. The described method is also suited for the development process of new systems, where it replaces time-consuming and costly field testing with the advantage of a higher accuracy of the measured data (compared to the typically used measurement equipment in field tests) and identical, thus comparable boundary conditions. Thus, the method can be used for system optimization in the test bench under realistic operative conditions, i.e. under relevant operating environment in the lab. This report describes the physical boundaries of the tested systems, as well as the test procedures and the requirements for both the unit under test and the test facility. The new six day and twelve day test profiles are also described as are the validation results.
Resumo:
As continued global funding and coordination are allocated toward the improvement of access to safe sources of drinking water, alternative solutions may be necessary to expand implementation to remote communities. This report evaluates two technologies used in a small water distribution system in a mountainous region of Panama; solar powered pumping and flow-reducing discs. The two parts of the system function independently, but were both chosen for their ability to mitigate unique issues in the community. The design program NeatWork and flow-reducing discs were evaluated because they are tools taught to Peace Corps Volunteers in Panama. Even when ample water is available, mountainous terrains affect the pressure available throughout a water distribution system. Since the static head in the system only varies with the height of water in the tank, frictional losses from pipes and fittings must be exploited to balance out the inequalities caused by the uneven terrain. Reducing the maximum allowable flow to connections through the installation of flow-reducing discs can help to retain enough residual pressure in the main distribution lines to provide reliable service to all connections. NeatWork was calibrated to measured flow rates by changing the orifice coefficient (θ), resulting in a value of 0.68, which is 10-15% higher than typical values for manufactured flow-reducing discs. NeatWork was used to model various system configurations to determine if a single-sized flow-reducing disc could provide equitable flow rates throughout an entire system. There is a strong correlation between the optimum single-sized flow- reducing disc and the average elevation change throughout a water distribution system; the larger the elevation change across the system, the smaller the recommended uniform orifice size. Renewable energy can jump the infrastructure gap and provide basic services at a fraction of the cost and time required to install transmission lines. Methods for the assessment of solar powered pumping systems as a means for rural water supply are presented and assessed. It was determined that manufacturer provided product specifications can be used to appropriately design a solar pumping system, but care must be taken to ensure that sufficient water can be provided to the system despite variations in solar intensity.
Resumo:
"DSE-2322-1."
Resumo:
"February 1992."
Resumo:
Although there are many ways to cut you water heating bills, the all fall into two broad categories: reducing the amount of hot water you use and making your water heating system more efficient. Fortunately, there are several strategies that can help you consume less energy and save money - and still meet you hot water needs without sacrificing comfort or practicality. The booklet was designed to answer common questions about hot water systems and to provide you with the information necessary to make informed decision about a wide variety of topics, ranging from repairing hot water faucet leaks an insulation water supply pipes to installing low-flow shower heads and tuning you your existing water heather. You'll also find details on what to consider when it's time to go comparison shopping for a new water heater-including an evaluation of the alternatives to the common gas or electric storage tank unit that's found in the majority of homes in Iowa and across the country.
Resumo:
Emissions from residential combustion appliances vary significantly depending on the firing behaviours and combustion conditions, in addition to combustion technologies and fuel quality. Although wood pellet combustion in residential heating boilers is efficient, the combustion conditions during start-up and stop phases are not optimal and produce significantly high emissions such as carbon monoxide and hydrocarbon from incomplete combustion. The emissions from the start-up and stop phases of the pellet boilers are not fully taken into account in test methods for ecolabels which primarily focus on emissions during operation on full load and part load. The objective of the thesis is to investigate the emission characteristics during realistic operation of residential wood pellet boilers in order to identify when the major part of the annual emissions occur. Emissions from four residential wood pellet boilers were measured and characterized for three operating phases (start-up, steady and stop). Emissions from realistic operation of combined solar and wood pellet heating systems was continuously measured to investigate the influence of start-up and stop phases on total annual emissions. Measured emission data from the pellet devices were used to build an emission model to predict the annual emission factors from the dynamic operation of the heating system using the simulation software TRNSYS. Start-up emissions are found to vary with ignition type, supply of air and fuel, and time to complete the phase. Stop emissions are influenced by fan operation characteristics and the cleaning routine. Start-up and stop phases under realistic operation conditions contribute 80 – 95% of annual carbon monoxide (CO) emission, 60 – 90% total hydrocarbon (TOC), 10 – 20% of nitrogen oxides (NO), and 30 – 40% particles emissions. Annual emission factors from realistic operation of tested residential heating system with a top fed wood pelt boiler can be between 190 and 400 mg/MJ for the CO emissions, between 60 and 95 mg/MJ for the NO, between 6 and 25 mg/MJ for the TOC, between 30 and 116 mg/MJ for the particulate matter and between 2x10-13 /MJ and 4x10-13 /MJ for the number of particles. If the boiler has the cleaning sequence with compressed air such as in boiler B2, annual CO emission factor can be up to 550 mg/MJ. Average CO, TOC and particles emissions under realistic annual condition were greater than the limits values of two eco labels. These results highlight the importance of start-up and stop phases in annual emission factors (especially CO and TOC). Since a large or dominating part of the annual emissions in real operation arise from the start-up and stop sequences, test methods required by the ecolabels should take these emissions into account. In this way it will encourage the boiler manufacturers to minimize annual emissions. The annual emissions of residential pellet heating system can be reduced by optimizing the number of start-ups of the pellet boiler. It is possible to reduce up to 85% of the number of start-ups by optimizing the system design and its controller such as switching of the boiler pump after it stops, using two temperature sensors for boiler ON/OFF control, optimizing of the positions of the connections to the storage tank, increasing the mixing valve temperature in the boiler circuit and decreasing the pump flow rate. For 85 % reduction of start-ups, 75 % of CO and TOC emission factors were reduced while 13% increase in NO and 15 % increase in particle emissions was observed.
Resumo:
We studied the feasibility of using a system of Solar Water Heating (SAS) with low cost, for three configurations. In configurations I and II have the collector grid absorber composed of six PVC tubes placed in parallel on the tile cement. In configuration II, the PVC tubes were transparent cover made of plastic bottles. Configuration III uses a collector composed of 12 black HDPE pipes, supported on four cement tiles 2.44 m x 0.50 m, two by two overlapping and interspersed with a filling of glass wool, comprising an area exposed to the global radiation incident of 2.44 m2, with the top two tiles painted matte black. In this configuration, the HDPE pipes replace conventional PVC pipes painted black. The total cost of SAS for configuration III, the most economical, was around $ 150.00. For the configurations tested the system of operation was thermosyphon collector. The study showed that the proposed systems have good thermal efficiency, are easy to install and handle and have low cost compared to conventional.
Resumo:
This paper presents an analysis of technical and financial feasibility of the use of a solar system for water heating in a fictitious hotel located in the Northeast region. Thereunto it is used techniques of solar collectors´ sizing and methods of financial mathematics, such as Net Present Value (NPV), Internal Rate of Return (IRR) and Payback. It will also be presented a sensitivity analysis to verify which are the factors that impact the viability of the solar heating. Comparative analysis will be used concerning three cities of distinct regions of Brazil: Curitiba, Belém and João Pessoa. The viability of using a solar heating system will be demonstrated to the whole Brazil, especially to the northeast region as it is the most viable for such an application of solar power because of its high levels of solar radiation. Among the cities examined for a future installation of solar heating systems for water heating in the hotel chain, João Pessoa was the one that has proved more viable.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Esta tesis pretende contribuir al fomento y utilización de la energía solar como alternativa para la producción de agua caliente en el sector agroindustrial. La demanda de agua caliente es un aspecto clave en un gran número de agroindustrias y explotaciones agrarias. Esta demanda presenta una gran variabilidad, tanto en los horarios en que se solicita como en la temperatura del agua del depósito requerida (TADr), difiriendo del perfil de demanda habitual para uso doméstico. Existe una necesidad de profundizar en la influencia que tiene la variación de la TADr en la eficiencia y viabilidad de estos sistemas. El objetivo principal de esta tesis es caracterizar el funcionamiento de un sistema solar térmico (SST) con captador de tubos de vacío (CTV) para producir agua a temperaturas superiores a las habituales en estos sistemas. Se pretende determinar la influencia que la TADr tiene sobre la eficiencia energética del sistema, cuantificar el volumen de agua caliente que es capaz de suministrar en función de la TADr y determinar la rentabilidad del SST como sistema complementario de suministro. Para ello, se ha diseñado, instalado y puesto a punto un sistema experimental de calentamiento de agua, monitorizando su funcionamiento a diferentes TADr bajo condiciones ambientales reales. Los resultados cuantifican cómo el aumento de la TADr provoca una disminución de la energía suministrada al depósito, pudiendo superar diferencias de 1000 Wh m-2 d-1 entre 40 ºC y 80 ºC, para valores de irradiación solar próximos a 8000 Wh m-2 d-1 (la eficiencia del sistema oscila entre 73% y 56%). Esta reducción es consecuencia de la disminución de la eficiencia del captador y del aumento de las pérdidas de calor en las tuberías del circuito. En cuanto al agua suministrada, cuanto mayor es la TADr, mayor es la irradiación solar requerida para que tenga lugar la primera descarga de agua, aumentando el tiempo entre descargas y disminuyendo el número de éstas a lo largo del día. A medida que se incrementa la TADr, se produce una reducción del volumen de agua suministrado a la TADr, por factores como la pérdida de eficiencia del captador, las pérdidas en las tuberías, la energía acumulada en el agua que no alcanza la TADr y la mayor energía extraída del sistema en el agua producida. Para una TADr de 80 ºC, una parte importante de la energía permanece acumulada en el depósito sin alcanzar la TADr al final del día. Para aprovechar esta energía sería necesario disponer de un sistema complementario de suministro, ya que las pérdidas de calor nocturnas en el depósito pueden reducir considerablemente la energía útil disponible al día siguiente. La utilización del sistema solar como sistema único de suministro es inviable en la mayoría de los casos, especialmente a TADr elevadas, al no ajustarse la demanda de agua caliente a la estacionalidad de la producción del sistema solar, y al existir muchos días sin producción de agua caliente por la ausencia de irradiación mínima. Por el contrario, la inversión del sistema solar como sistema complementario para suministrar parte de la demanda térmica de una instalación es altamente recomendable. La energía útil anual del sistema solar estimada oscila entre 1322 kWh m-2 y 1084 kWh m-2. La mayor rentabilidad se obtendría suponiendo la existencia de una caldera eléctrica, donde la inversión se recuperaría en pocos años -entre 5.7 años a 40 ºC y 7.2 años a 80 ºC -. La rentabilidad también es elevada suponiendo la existencia de una caldera de gasóleo, con periodos de recuperación inferiores a 10 años. En una industria ficticia con demanda de 100 kWh d-1 y caldera de gasóleo existente, la inversión en una instalación solar optimizada sería rentable a cualquier TADr, con valores de VAN cercanos a la inversión realizada -12000 € a 80 ºC y 15000€ a 40 ºC- y un plazo de recuperación de la inversión entre 8 y 10 años. Los resultados de este estudio pueden ser de gran utilidad a la hora de determinar la viabilidad de utilización de sistemas similares para suministrar la demanda de agua caliente de agroindustrias y explotaciones agropecuarias, o para otras aplicaciones en las que se demande agua a temperaturas distintas de la habitual en uso doméstico (60 ºC). En cada caso, los rendimientos y la rentabilidad vendrán determinados por la irradiación de la zona, la temperatura del agua requerida y la curva de demanda de los procesos específicos. ABSTRACT The aim of this thesis is to contribute to the development and use of solar energy as an alternative for producing hot water in the agribusiness sector. Hot water supply is a key issue for a great many agribusinesses and agricultural holdings. Both hot water demand times and required tank water temperature (rTWT) are highly variable, where the demand profile tends to differ from domestic use. Further research is needed on how differences in rTWT influence the performance and feasibility of these systems. The main objective of this thesis is to characterize the performance and test the feasibility of an evacuated tube collector (ETC) solar water heating (SWH) system providing water at a higher temperature than is usual for such systems. The aim is to determine what influence the rTWT has on the system’s energy efficiency, quantify the volume of hot water that the system is capable of supplying at the respective rTWT and establish whether SWH is feasible as a booster supply system for the different analysed rTWTs. To do this, a prototype water heating system has been designed, installed and commissioned and its performance monitored at different rTWTs under real operating conditions. The quantitative results show that a higher rTWT results in a lower energy supply to the tank, where the differences may be greater than 1000 Wh m-2 d-1 from 40 ºC to 80 ºC for insolation values of around 8000 Wh m-2 d-1 (system efficiency ranges from 73% to 56%). The drop in supply is due to lower collector efficiency and greater heat losses from the pipe system. As regards water supplied at the rTWT, the insolation required for the first withdrawal of water to take place is greater at higher rTWTs, where the time between withdrawals increases and the number of withdrawals decreases throughout the day. As rTWT increases, the volume of water supplied at the rTWT decreases due to factors such as lower collector efficiency, pipe system heat losses, energy stored in the water at below the rTWT and more energy being extracted from the system by water heating. For a rTWT of 80 ºC, much of the energy is stored in the tank at below the rTWT at the end of the day. A booster supply system would be required to take advantage of this energy, as overnight tank heat losses may significantly reduce the usable energy available on the following day. It is often not feasible to use the solar system as a single supply system, especially at high rTWTs, as, unlike the supply from the solar heating system which does not produce hot water on many days of the year because insolation is below the required minimum, hot water demand is not seasonal. On the other hand, investment in a solar system as a booster system to meet part of a plant’s heat energy demand is highly recommended. The solar system’s estimated annual usable energy ranges from 1322 kWh m-2 to 1084 kWh m-2. Cost efficiency would be greatest if there were an existing electric boiler, where the payback period would be just a few years —from 5.7 years at 40 ºC to 7.2 years at 80 ºC—. Cost efficiency is also high if there is an existing diesel boiler with payback periods of under 10 years. In a fictitious industry with a demand of 100 kWh day-1 and an existing diesel boiler, the investment in the solar plant would be highly recommended at any rTWT, with a net present value similar to investment costs —12000 € at 80 ºC and 15000 € at 40 ºC— and a payback period of 10 years. The results of this study are potentially very useful for determining the feasibility of using similar systems for meeting the hot water demand of agribusinesses and arable and livestock farms or for other applications demanding water at temperatures not typical of domestic demand (60ºC). Performance and cost efficiency will be determined by the regional insolation, the required water temperature and the demand curve of the specific processes in each case.
Resumo:
Report year ends Sept. 30.
Resumo:
This thesis aims to investigate the fundamental processes governing the performance of different types of photoelectrodes used in photoelectrochemical (PEC) applications, such as unbiased water splitting for hydrogen production. Unraveling the transport and recombination phenomena in nanostructured and surface-modified heterojunctions at a semiconductor/electrolyte interface is not trivial. To approach this task, the work presented here first focus on a hydrogen-terminated p-silicon photocathode in acetonitrile, considered as a standard reference for PEC studies. Steady-state and time-resolved excitation at long wavelength provided clear evidence of the formation of an inversion layer and revealed that the most optimal photovoltage and the longest electron-hole pair lifetime occurs when the reduction potential for the species in solution lies within the unfilled conduction band states. Understanding more complex systems is not as straight-forward and a complete characterization that combine time- and frequency-resolved techniques is needed. Intensity modulated photocurrent spectroscopy and transient absorption spectroscopy are used here on WO3/BiVO4 heterojunctions. By selectively probing the two layers of the heterojunction, the occurrence of interfacial recombination was identified. Then, the addition of Co-Fe based overlayers resulted in passivation of surface states and charge storage at the overlayer active sites, providing higher charge separation efficiency and suppression of recombination in time scales that go from picoseconds to seconds. Finally, the charge carrier kinetics of several different Cu(In,Ga)Se2 (CIGS)-based architectures used for water reduction was investigated. The efficiency of a CIGS photocathode is severely limited by charge transfer at the electrode/electrolyte interface compared to the same absorber layer used as a photovoltaic cell. A NiMo binary alloy deposited on the photocathode surface showed a remarkable enhancement in the transfer rate of electrons in solution. An external CIGS photovoltaic module assisting a NiMo dark cathode displayed optimal absorption and charge separation properties and a highly performing interface with the solution.
Resumo:
This article presents a tool for the allocation analysis of complex systems of water resources, called AcquaNetXL, developed in the form of spreadsheet in which a model of linear optimization and another nonlinear were incorporated. The AcquaNetXL keeps the concepts and attributes of a decision support system. In other words, it straightens out the communication between the user and the computer, facilitates the understanding and the formulation of the problem, the interpretation of the results and it also gives a support in the process of decision making, turning it into a clear and organized process. The performance of the algorithms used for solving the problems of water allocation was satisfactory especially for the linear model.