584 resultados para Soft contact lens


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Whether the first daily disposable soft contact lens to enter the market in 1994 was the Premier lens (Award Technology, Scotland, UK; subsequently purchased by Bausch & Lomb, Rochester New York, USA) or the 1-Day Acuvue lens (Johnson and Johnson Vision Care, Jacksonville, Florida, USA) has long been a matter of bitter dispute1 but whatever the answer, this year marks the 20th anniversary of the launch of this modality of lens wear...

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to evaluate the outcome of patients with healed moderate to severe contact lens-associated corneal infectious ulcers who were re-fit with contact lenses. Methods: We retrospectively studied patients who were fit with contact lenses on our service and who had had moderate to severe corneal infectious ulcers associated with previous contact lens use. Six patients were included in the study. Results: Gas permeable contact lenses were fit in five patients, and a soft contact lens was fit in one patient. Successful fit was achieved in all cases and visual acuities were equal to or better than 20/30 in all patients. No significant complications were observed after a mean follow-up of 23 months (range, 6-45 months). Conclusion: In this small series of patients with a history of moderate to severe contact-lens related infectious keratitis, no complications were observed after contact lenses were refit. Contact lens wear in patients with a history of infectious keratitis may be safe and useful in order to achieve visual rehabilitation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: Polyvinyl alcohol (PVA) is a successful tear film stabiliser and is widely used in comfort drops and some soft contact lens materials. A PVA-containing lens, nelfilcon A has been modified to include additional (non-functional) PVA in order to provide improved comfort. This study aims to examine the clinical performance of this nelfilcon A lens with AquaRelease™ (AquaRelease). Methods: Two contralateral, investigator masked, open label, subjective and objective evaluations were conducted. The first examined the effect of adding increased molecular weight PVA to nelfilcon A (n = 5), and the second compared this AquaRelease lens to ocufilcon B (n = 34). The principal measures were non-invasive break-up time (NIBUT) and subjective comfort, which were assessed at the beginning and end of a week of daily wear, and three times throughout 1 day at 8, 12 and 16 h. Results: All subjects successfully completed the daily wearing schedule of 16 h. On initial insertion, subjective comfort and NIBUT improved for AquaRelease than original nelfilcon A lenses (p < 0.05). Initial comfort was better for AquaRelease compared to ocufilcon B lenses (p = 0.01); however, NIBUT was not statistically different (11.7 ± 15.6 s versus 8.4 ± 6.8 s; p = 0.26). Subjective comfort decreased with time (p < 0.001), but there was no significant difference between AquaRelease and ocufilcon B lenses (p = 0.16). NIBUT was not significantly affected by time (p = 0.56) or between lenses (p = 0.33). At the end of a weeks' wear, subjective initial, end-of-day, overall comfort and vision were rated significantly better with AquaRelease than ocufilcon B (p < 0.01). Conclusions: Release of additional non-functionalised PVA from the nelfilcon A lenses appears to enhance comfortable contact lens wear. © 2006 British Contact Lens Association.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To compare monochromatic aberrations of keratoconic eyes when uncorrected, corrected with spherically-powered RGP (rigid gas-permeable) contact lenses and corrected using simulations of customised soft contact lenses for different magnitudes of rotation (up to 15°) and translation (up to 1mm) from their ideal position. Methods: The ocular aberrations of examples of mild, moderate and severe keratoconic eyes were measured when uncorrected and when wearing their habitual RGP lenses. Residual aberrations and point-spread functions of each eye were simulated using an ideal, customised soft contact lens (designed to neutralise higher-order aberrations, HOA) were calculated as a function of the angle of rotation of the lens from its ideal orientation, and its horizontal and vertical translation. Results: In agreement with the results of other authors, the RGP lenses markedly reduced both lower-order aberrations and HOA for all three patients. When compared with the RGP lens corrections, the customised lens simulations only provided optical improvements if their movements were constrained within limits which appear to be difficult to achieve with current technologies. Conclusions: At the present time, customised contact lens corrections appear likely to offer, at best, only minor optical improvements over RGP lenses for patients with keratoconus. If made in soft materials, however, these lenses may be preferred by patients in term of comfort. © 2012 The College of Optometrists.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To assess the validity and repeatability of objective compared to subjective contact lens fit analysis. Methods: Thirty-five subjects (aged 22.0. ±. 3.0 years) wore two different soft contact lens designs. Four lens fit variables: centration, horizontal lag, post-blink movement in up-gaze and push-up recovery speed were assessed subjectively (four observers) and objectively from slit-lamp biomicroscopy captured images and video. The analysis was repeated a week later. Results: The average of the four experienced observers was compared to objective measures, but centration, movement on blink, lag and push-up recovery speed all varied significantly between them (p <. 0.001). Horizontal lens centration was on average close to central as assessed both objectively and subjectively (p > 0.05). The 95% confidence interval of subjective repeatability was better than objective assessment (±0.128. mm versus ±0.168. mm, p = 0.417), but utilised only 78% of the objective range. Vertical centration assessed objectively showed a slight inferior decentration (0.371. ±. 0.381. mm) with good inter- and intrasession repeatability (p > 0.05). Movement-on-blink was lower estimated subjectively than measured objectively (0.269. ±. 0.179. mm versus 0.352. ±. 0.355. mm; p = 0.035), but had better repeatability (±0.124. mm versus ±0.314. mm 95% confidence interval) unless correcting for the smaller range (47%). Horizontal lag was lower estimated subjectively (0.562. ±. 0.259. mm) than measured objectively (0.708. ±. 0.374. mm, p <. 0.001), had poorer repeatability (±0.132. mm versus ±0.089. mm 95% confidence interval) and had a smaller range (63%). Subjective categorisation of push-up speed of recovery showed reasonable differentiation relative to objective measurement (p <. 0.001). Conclusions: The objective image analysis allows an accurate, reliable and repeatable assessment of soft contact lens fit characteristics, being a useful tool for research and optimisation of lens fit in clinical practice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The primary outcome of this study is to compare the axial length growth of white European myopic children wearing orthokeratology contact lenses (OK) to a control group (CT) over a 7-year period. Methods: Subjects 6–12 years of age with myopia −0.75 to −4.00DS and astigmatism ≤1.00DC were prospectively allocated OK or distance single-vision spectacles (SV) correction. Measurements of axial length (Zeiss IOLMaster), corneal topography, and cycloplegic refraction were taken at 6-month intervals over a 2-year period. Subjects were invited to return to the clinic approximately 5 years later (i.e., 7 years after the beginning of the study) for assessment of their ocular refractive and biometric components. The CT consisted of 4 SV and 12 subjects who switched from SV to soft contact lens wear after the initial 2 years of SV lens wear. Changes in axial length relative to baseline over a 7-year period were compared between groups. Results: Fourteen and 16 subjects from the OK and CT groups, respectively, were examined 6.7 ± 0.5 years after the beginning of the study. Statistically significant changes in the axial length were found over time and between groups (both p <0.001), but not for the time*group interaction (p = 0.125). The change in the axial length for the OK group was 22% (p = 0.328), 42% (p = 0.007), 40% (p = 0.020), 41% (p = 0.013), and 33% (p = 0.062) lower than the CT group following 6, 12, 18, 24, and 84 months of lens wear, respectively. Conclusion: A trend toward a reduction in the rate of axial elongation of the order of 33% was found in the OK group in comparison to the CT group following 7 years of lens wear.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: A population based, cross-sectional telephone survey was conducted to estimate the total penetrance of contact lens wear in Australia. Methods: A total of 42,749 households around Australia were randomly selected from the national electronic telephone directory based on postcode distribution. Before contact was attempted, letters of introduction were sent. The number of individuals and contact lens wearers in each household was ascertained and lens wearers were interviewed to determine details of lens type and mode of wear using a structured questionnaire. Results: Of households contacted, 59.2% (19,171/32,405) agreed to participate. Response rates were only marginally higher amongst households that first received a letter of introduction. In these households, 35,914 individuals were identified, of which, 1,798 were contact lens wearers. The penetrance of contact lens wear during the study period was 5.01% (95% CI: 4.78-5.24). Soft hydrogel lenses had the largest penetrance in the community, (66.7% of all wearers), however, their market share decreased significantly over the study period with increased uptake of newly introduced lens types. Conclusions: The penetrance of contact lens wear concurs with market estimates and equates to approximately 680,000 contact lens wearers aged between 15 and 64 years in Australia. The low response rate obtained in this study highlights the difficulty in contemporary use of telephone survey methodology

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives. To evaluate the performance of the dynamic-area high-speed videokeratoscopy technique in the assessment of tear film surface quality with and without the presence of soft contact lenses on eye. Methods. Retrospective data from a tear film study using basic high-speed videokeratoscopy, captured at 25 frames per second, (Kopf et al., 2008, J Optom) were used. Eleven subjects had tear film analysis conducted in the morning, midday and evening on the first and seventh day of one week of no lens wear. Five of the eleven subjects then completed an extra week of hydrogel lens wear followed by a week of silicone hydrogel lens wear. Analysis was performed on a 6 second period of the inter-blink recording. The dynamic-area high-speed videokeratoscopy technique uses the maximum available area of Placido ring pattern reflected from the tear interface and eliminates regions of disturbance due to shadows from the eyelashes. A value of tear film surface quality was derived using image rocessing techniques, based on the quality of the reflected ring pattern orientation. Results. The group mean tear film surface quality and the standard deviations for each of the conditions (bare eye, hydrogel lens, and silicone hydrogel lens) showed a much lower coefficient of variation than previous methods (average reduction of about 92%). Bare eye measurements from the right and left eyes of eleven individuals showed high correlation values (Pearson’s correlation r = 0.73, p < 0.05). Repeated measures ANOVA across the 6 second period of measurement in the normal inter-blink period for the bare eye condition showed no statistically significant changes. However, across the 6 second inter-blink period with both contact lenses, statistically significant changes were observed (p < 0.001) for both types of contact lens material. Overall, wearing hydrogel and silicone hydrogel lenses caused the tear film surface quality to worsen compared with the bare eye condition (repeated measures ANOVA, p < 0.0001 for both hydrogel and silicone hydrogel). Conclusions. The results suggest that the dynamic-area method of high-speed videokeratoscopy was able to distinguish and quantify the subtle, but systematic worsening of tear film surface quality in the inter-blink interval in contact lens wear. It was also able to clearly show a difference between bare eye and contact lens wearing conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Contact lenses are mainly fitted by registered optometrists and contact lens opticians in the UK. Data we have gathered from annual contact lens fitting surveys over the past 12 years indicate that, on average, registered optometrists and contact lens opticians undertake 3.2 and 7.1 contact lens fits per week (p < 0.0001). More experienced practitioners tend to fit older patients. Practitioners fitting more lenses per year tend to fit a higher proportion of soft lenses. Contact lens opticians tend to fit a higher proportion of patients with planned replacement and daily disposable lenses compared with optometrists.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hydrogel polymers are used for the manufacture of soft (or disposable) contact lenses worldwide today, but have a tendency to dehydrate on the eye. In vitro methods that can probe the potential for a given hydrogel polymer to dehydrate in vivo are much sought after. Nuclear magnetic resonance (NMR) has been shown to be effective in characterising water mobility and binding in similar systems (Barbieri, Quaglia et al., 1998, Larsen, Huff et al., 1990, Peschier, Bouwstra et al., 1993), predominantly through measurement of the spin-lattice relaxation time (T1), the spinspin relaxation time (T2) and the water diffusion coefficient (D). The aim of this work was to use NMR to quantify the molecular behaviour of water in a series of commercially available contact lens hydrogels, and relate these measurements to the binding and mobility of the water, and ultimately the potential for the hydrogel to dehydrate. As a preliminary study, in vitro evaporation rates were measured for a set of commercial contact lens hydrogels. Following this, comprehensive measurement of the temperature and water content dependencies of T1, T2 and D was performed for a series of commercial hydrogels that spanned the spectrum of equilibrium water content (EWC) and common compositions of contact lenses that are manufactured today. To quantify material differences, the data were then modelled based on theory that had been used for similar systems in the literature (Walker, Balmer et al., 1989, Hills, Takacs et al., 1989). The differences were related to differences in water binding and mobility. The evaporative results suggested that the EWC of the material was important in determining a material's potential to dehydrate in this way. Similarly, the NMR water self-diffusion coefficient was also found to be largely (if not wholly) determined by the WC. A specific binding model confirmed that the we was the dominant factor in determining the diffusive behaviour, but also suggested that subtle differences existed between the materials used, based on their equilibrium we (EWC). However, an alternative modified free volume model suggested that only the current water content of the material was important in determining the diffusive behaviour, and not the equilibrium water content. It was shown that T2 relaxation was dominated by chemical exchange between water and exchangeable polymer protons for materials that contained exchangeable polymer protons. The data was analysed using a proton exchange model, and the results were again reasonably correlated with EWC. Specifically, it was found that the average water mobility increased with increasing EWe approaching that of free water. The T1 relaxation was also shown to be reasonably well described by the same model. The main conclusion that can be drawn from this work is that the hydrogel EWe is an important parameter, which largely determines the behaviour of water in the gel. Higher EWe results in a hydrogel with water that behaves more like bulk water on average, or is less strongly 'bound' on average, compared with a lower EWe material. Based on the set of materials used, significant differences due to composition (for materials of the same or similar water content) could not be found. Similar studies could be used in the future to highlight hydrogels that deviate significantly from this 'average' behaviour, and may therefore have the least/greatest potential to dehydrate on the eye.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rigid lenses have been fitted less since the introduction of soft lenses nearly 40 years ago. Data that we have gathered from annual contact lens fitting surveys conducted in Australia, Canada, Japan, the Netherlands, Norway, the UK and the USA between 2000 and 2008 facilitate an accurate characterization of the pattern of the decline of rigid lens fitting during the first decade of this century. There is a trend for rigid lenses to be utilized primarily for refitting those patients who are already successful rigid lens wearers—most typically older females being refit with higher Dk materials. Rigid lenses are generally fitted on a full-time basis (four or more days of wear per week) without a planned replacement schedule. Orthokeratology is especially popular in the Netherlands, but is seldom prescribed in the other countries surveyed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The aim was to document contact lens prescribing trends in Australia between 2000 and 2009. ---------- Methods: A survey of contact lens prescribing trends was conducted each year between 2000 and 2009. Australian optometrists were asked to provide information relating to 10 consecutive contact lens fittings between January and March each year. ---------- Results: Over the 10-year survey period, 1,462 practitioners returned survey forms representing a total of 13,721 contact lens fittings. The mean age (± SD) of lens wearers was 33.2 ± 13.6 years and 65 per cent were female. Between 2006 and 2009, rigid lens new fittings decreased from 18 to one per cent. Low water content lenses reduced from 11.5 to 3.2 per cent of soft lens fittings between 2000 and 2008. Between 2005 and 2009, toric lenses and multifocal lenses represented 26 and eight per cent, respectively, of all soft lenses fitted. Daily disposable, one- to two-week replacement and monthly replacement lenses accounted for 11.6, 30.0 and 46.5 per cent of all soft lens fittings over the survey period, respectively. The proportion of new soft fittings and refittings prescribed as extended wear has generally declined throughout the past decade. Multi-purpose lens care solutions dominate the market. Rigid lenses and monthly replacement soft lenses are predominantly worn on a full-time basis, whereas daily disposable soft lenses are mainly worn part-time.---------- Conclusions: This survey indicates that technological advances, such as the development of new lens materials, manufacturing methods and lens designs, and the availability of various lens replacement options, have had a significant impact on the contact lens market during the first decade of the 21st Century.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Silicone hydrogel contact lenses were introduced into the market in 1999. To assess prescribing trends of this lens type since then, up to 1000 survey forms were sent to contact lens fitters in Australia, Canada, Japan, the Netherlands, Norway, the UK and the USA each year between 2000 and 2008. Practitioners were asked to record data relating to the first 10 contact lens fits or refits performed after receiving the survey form. Analysis of returned forms revealed a rapid increase in the prescribing of silicone hydrogel lenses over the survey period. In 2008, silicone hydrogel lenses represented 36% of all soft lenses prescribed. The categorization of the majority of lenses prescribed as ‘refits’ is primarily attributed to the mass conversion of lens wearers from hydrogel to silicone hydrogel lenses. Silicone hydrogels may soon represent the majority of soft contact lenses prescribed.