In this work. co-current flow characteristics of air/non-Newtonian liquid systems in inclined smooth pipes are studied experimentally and theoretically using transparent tubes of 20, 40 and 60 turn in diameter. Each tube includes two 10 m lone pipe branches connected by a U-bend that is capable of being inclined to any angle, from a completely horizontal to a fully vertical position. The flow rate of each phase is varied over a wide range. The studied flow phenomena are bubbly, plug flow, slug flow, churn flow and annular flow. These are observed and recorded by a high flow. stratified flow. -speed camera over a wide range of operating conditions. The effects of the liquid phase properties, the inclination angle and the pipe diameter on two-phase flow characteristics are systematically studied. The Heywood-Charles model for horizontal flow was modified to accommodate stratified flow in inclined pipes, taking into account the average void fraction and pressure drop of the mixture flow of a gas/non-Newtonian liquid. The pressure drop gradient model of Taitel and Barnea for a gas/Newtonian liquid slug flow was extended to include liquids possessing shear-thinning flow behaviour in inclined pipes. The comparison of the predicted values with the experimental data shows that the models presented here provide a reasonable estimate of the average void fraction and the corresponding pressure drop for the mixture flow of a gas/ non-Newtonian liquid. (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
In this work, a simple correlation, which incorporates the mixture velocity, drift velocity, and the correction factor of Farooqi and Richardson, was proposed to predict the void fraction of gas/non-Newtonian intermittent flow in upward inclined pipes. The correlation was based on 352 data points covering a wide range of flow rates for different CMC solutions at diverse angles. A good agreement was obtained between the predicted and experimental results. These results substantiated the general validity of the model presented for gas/non-Newtonian two-phase intermittent flows.
Resumo:
The purpose of this study was to develop a pilot plant which the main goal is to emulate a flow peak pressure in a separation vessel. Effect similar that is caused by the production in a slug flow in production wells equipped with the artificial lift method plunger lift. The motivation for its development was the need to test in a plant on a smaller scale, a new technique developed to estimate the gas flow in production wells equipped with plunger lift. To develop it, studies about multiphase flow effects, operation methods of artificial lift in plunger lift wells, industrial instrumentation elements, control valves, vessel sizing separators and measurement systems were done. The methodology used was the definition of process flowcharts, its parameters and how the effects needed would be generated for the success of the experiments. Therefore, control valves, the design and construction of vessels and the acquisition of other equipment used were defined. One of the vessels works as a tank of compressed air that is connected to the separation vessel and generates pulses of gas controlled by a on/off valve. With the emulator system ready, several control experiments were made, being the control of peak flow pressure generation and the flow meter the main experiments, this way, it was confirmed the efficiency of the plant usage in the problem that motivated it. It was concluded that the system is capable of generate effects of flow with peak pressure in a primary separation vessel. Studies such as the estimation of gas flow at the exit of the vessel and several academic studies can be done and tested on a smaller scale and then applied in real plants, avoiding waste of time and money.
Resumo:
Despite its importance for designing evaporators and condensers, a review of the literature shows that heat transfer data during phase change of carbon dioxide is very limited, mainly for microchannel flows. In order to give a contribution on this subject, an experimental study of CO 2 evaporation inside a 0.8 mm-hydraulic diameter microchannel was performed in this work. The average heat transfer coefficient along the microchannel was measured and visualization of the flow patterns was conducted. A total of 67 tests were performed at saturation temperature of 23.3°C for a heat flux of 1800 W/(m2°C). Vapor qualities ranged from 0.005 to 0.88 and mass flux ranged from 58 to 235 kg/(m2s). An average heat transfer coefficient of 9700 W/(m2°C) with a standard deviation of 35% was obtained. Nucleate boiling was found to characterize the flow regime for the test conditions. The dryout of the flow, characterized by the sudden reduction in the heat transfer coefficient, was identified at vapor qualities around 0.85. Flow visualization results showed three flow patterns. For low vapor qualities (up to about 0.25), plug flow was predominant, while slug flow occurred at moderated vapor qualities (from about 0.25 to 0.50). Annular flow was the flow pattern for higher vapor qualities. Copyright © 2006 by ABCM.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Programa informático desarrollado en plataforma EXCEL (VBA) y dirigido al diseño de Separadores de dos y tres fases, verticales y horizontales. El programa de ordenador o aplicación tiene la capacidad de determinar las propiedades físicas del fluido, utilizando diferentes correlaciones sobre la base del “Black Oil Model”, con dichas propiedades el Programa predice el tipo de flujo presente. Si el tipo de flujo es “Slug Flow” el programa determinara las dimensiones del “Slug catcher” necesario. Bajo las condiciones de funcionamiento existentes el programa diseñará el separador elegido: dos o tres fases, vertical u horizontal. Por último, la aplicación informática estimará el coste del equipo. Abstract Computer program developed in EXCEL (VBA) platform and aimed for the design of Two-Phase, Three-Phase, Vertical or Horizontal Separators. The computer Program or Application has the capability to determine the fluid physical properties utilizing different correlations on the basis of the Black Oil Model, with those Properties the Program will predict the Flow Regime present. If the flow regime is Slug Flow the program will determine the necessary slug catcher dimensions. Under certain operational conditions the program will design the selected: Two-Phase or Three-Phase, Vertical or Horizontal Separator. Finally the computer Application will estimate the cost of the equipment.
Resumo:
Gas-liquid two-phase flow is very common in industrial applications, especially in the oil and gas, chemical, and nuclear industries. As operating conditions change such as the flow rates of the phases, the pipe diameter and physical properties of the fluids, different configurations called flow patterns take place. In the case of oil production, the most frequent pattern found is slug flow, in which continuous liquid plugs (liquid slugs) and gas-dominated regions (elongated bubbles) alternate. Offshore scenarios where the pipe lies onto the seabed with slight changes of direction are extremely common. With those scenarios and issues in mind, this work presents an experimental study of two-phase gas-liquid slug flows in a duct with a slight change of direction, represented by a horizontal section followed by a downward sloping pipe stretch. The experiments were carried out at NUEM (Núcleo de Escoamentos Multifásicos UTFPR). The flow initiated and developed under controlled conditions and their characteristic parameters were measured with resistive sensors installed at four pipe sections. Two high-speed cameras were also used. With the measured results, it was evaluated the influence of a slight direction change on the slug flow structures and on the transition between slug flow and stratified flow in the downward section.
Resumo:
A new model is developed for predicting the transition from the slug to annular flow of adiabatic two-phase gas/liquid flow in microgravity (mu g) environment. This model is based on the analyses of the effects of the surface tension and the gas inertia in a sense of more physical approach. The drift-flux model is applied to determine the gas void fraction near the transition region. The new model is compared with previous models and experimental data, and the results show the improvement in explanation of the experimental results.
Resumo:
Flow regime transition criteria are of practical importance for two-phase flow analyses at reduced gravity conditions. Here, flow regime transition criteria which take the friction pressure loss effect into account were studied in detail. Criteria at reduced gravity conditions were developed by extending an existing model with various experimental datasets taken at microgravity conditions showed satisfactory agreement. Sample computations of the model were performed at various gravity conditions, such as 0.196, 1.62, 3.71, and 9.81 m/s2 corresponding to micro-gravity and lunar, Martian and Earth surface gravity, respectively. It was found that the effect of gravity on bubbly-slug and slug-annular (churn) transitions in a two-phase flow system was more pronounced at low liquid flow conditions, whereas the gravity effect could be ignored at high mixture volumetric flux conditions. While for the annular flow transitions due to flow reversal and onset of dropset entrainment, higher superficial gas velocity was obtained at higher gravity level.
Resumo:
When freshly starved amoebae of Dictyostelium discoideum are loaded with the Ca2+-specific dye indo-1/AM and analyzed in a fluorescence-activated cell sorter, they exhibit a quasi-bimodal distribution of fluorescence. This permits a separation of the population into two classes: H, or ''high Ca2+-indo-1 fluorescence,'' and L, or ''low Ca2+-indo-1 fluorescence.'' Simultaneous monitoring of Ca2+-indo-1 and Ca2+-chlortetracycline fluorescence shows that by and large the same cells tend to have high (or low) levels of both cytoplasmic and sequestered Ca2+. Next we label H cells with tetramethylrhodamine isothiocyanate (TRITC) and mix them in a 1:4 ratio with L cells, In the slugs that result, TRITC fluorescence is confined mainly to the anterior prestalk region. This implies that amoebae with relatively high Ca2+ at the vegetative stage tend to develop into prestalk cells and those with low Ca2+ into prespores. Polysphondylium violaceum, a cellular slime mold that does not possess prestalk and prespore cells, also does not display a Ca2+-dependent heterogeneity at the vegetative stage or in slugs. Finally, confirming earlier findings with the fluorophore fura-2 (Azhar ef al., Curr. Sci. 68, 337-342 (1995)), a prestalk-prespore difference in cellular Ca2+ is present in the cells of the slug in vivo. These findings are discussed in light of the possible roles of Ca2+ for cell differentiation in D. discoideum.
Resumo:
The Electrical Resistance Tomography (ERT) technique possesses great potential in monitoring widely exiting industrial two/multi-phase flow. For vertical pipe flow and inclined pipe flow, some application studies with exciting results have been reported, but there is rarely a paper regarding the application of ERT to horizontal gas/liquid pipe flow. This paper addresses this issue and proposes a smart method, Liquid Level Detection method, to conventional ERT system. The enhanced ERT system using the new method can monitor horizontal pipe flow effectively and its application is no longer restricted by the flow conditions. Some experimental results from monitoring an air/water slug pipe flow are presented.
Resumo:
Experimental studies have been performed for horizontal two-phase air-water flows at normal and reduced gravity conditions in a square cross-section channel. The experiments at reduced gravity are conducted on board the Russian IL-76 reduced gravity airplane. Four flow patterns, namely bubble, slug, slug-annular transition and annular flows, are observed depending on the liquid and gas superficial velocities at both conditions. Semi-theoretical Weber number model is developed to include the shape influence on the slug-annular transition. It is shown that its prediction is in reasonable agreement with the experimental slug-annular transition under both conditions. For the case of two-phase gas-liquid flow with large value of the Froude number, the drift-flux model can predict well the observed boundary between bubble and slug flows.
Resumo:
A first experimental study on two-phase how patterns at a long-term, steady microgravity condition was conducted on board the Russian Space Station "MIR" in August 1999. Carbogal and air are used as the liquid and the gas phase, respectively. Bubble, slug, slug-annular transitional, and annular hows are observed. A new region of annular how with lower liquid superficial velocity is discovered, and the region of the slug-annular transitional flow is wider than that observed by experiments on board the parabolic aircraft. The main patterns are bubble, slug-annular transitional and annular flows based on the experiments on board MIR space station. Some influences on the two-phase how patterns in the present experiments are discussed.
Resumo:
Bends are widely used in pipelines carrying single- and two-phase fluids in both ground and space applications. In particular, they play more important role in space applications due to the extreme spatial constraints. In the present study, a set of experimental data of two-phase flow patterns and their transitions in a 90degrees bend with inner diameter of 12.7 mm. and curvature radius of 76.5 mm at microgravity conditions are reported. Gas and liquid superficial velocities are found to range from (1.0 similar to 23.6) m/s for gas and (0.09 similar to 0.5) m/s for liquid, respectively. Three major flow patterns, namely slug, slug-annular transitional, and annular flows, are observed in this study. Focusing on the differences between flow patterns in bends and their counterparts in straight pipes, detailed analyses of their characteristics are made. The transitions between adjoining flow patterns are found to be more or less the same as those in straight pipes, and can be predicted using Weber number models satisfactorily. The reasons for such agreement are carefully examined.
Resumo:
A critical review on the mechanism and models on the bubble-to-slug transition of two-phase gas-liquid flows are presented in the present paper. It is shown that the most possible mechanism controlled the bubble-to-slug transition is the bubble coalescence. Focusing on the bubble-to-slug transition for the low-Re two-phase flow, a simple Monte Carlo method is used to simulate the influence of the initial bubble size on the bubble-to-slug transition. Some secondary factors, such as the liquid viscosity, the surface tension, and the relative slip between the two phases, are ignored in the present study. It is found that the locus of the dimensionless rate of collision is a universal curve. Based on this curve, it is determined that the bubble initial size can affect the phase distribution and flow pattern when its dimensionless value is in the range from 0.03 to 0.4. A simple relationship between the critical void fraction and the initial bubble size is proposed, which agrees very well with the experimental data.