908 resultados para Slow Sand Filtration
Resumo:
Fenton 's reagent was used as coagulant agent to treat water with high true color (100 ± 5 HU) caused by the introduction of humic substances extracted from peat, using dissolved air flotation. The pair value of coagulant dosage x coagulation pH was optimized to posterior construction of coagulation diagrams, reaching apparent color removal efficiency slightly superior to 60%. It was tried to simulate a treatment with complete cycle, carrying out an experiment with sand filtration after flotation, obtaining an effluent with excellent quality, presenting remnant apparent color, turbidity and absorbance of 253.7 nm less or equal to 2 HU, 0.40 TU and 0.009 cm -1, respectively, and residual total iron < 0.005 mg/L and DOC < 0.001 mg/L.
Resumo:
Pós-graduação em Engenharia Civil - FEIS
Resumo:
Esta Tesis Doctoral tiene como principal objetivo el obtener una cadena de tratamientos seguros de aguas seriados que nos permita asegurar la calidad de las aguas para consumo humano en caso de emergencias, de tal forma que se minimicen los efectos de acciones hostiles, como sabotajes o actos terroristas, desastres naturales, etc y buscar soluciones adecuadas para garantizar en este caso la salud. Las plantas de tratamientos de aguas existentes comercialmente no aseguran dicha calidad y la documentación sobre el tema presenta vacíos de conocimiento, contradicciones entre resultados de investigaciones o insostenibilidad de conclusiones de las mismas. Estas carencias nos permiten determinar los aspectos a tratar durante la investigación. Por ello, este objetivo se concretó en tres acciones: Investigar sobre rendimientos de plantas convencionales en eliminación de microorganismos y productos tóxicos y peligrosos. Introducir mejoras que garanticen el rendimiento de las plantas convencionales. Investigar sobre la conveniencia de complementar las instalaciones existentes buscando seguridad y garantía sanitaria. Y se desarrollaron tres líneas de investigación: LI 1 “Inorgánicos”: Investigación sobre la eliminación de los metales boro, cobre y molibdeno mediante procesos de intercambio iónico y de coagulaciónfloculación- decantación. LI 2 “Compuestos Orgánicos Volátiles”: Investigación sobre la eliminación de los compuestos orgánicos 1,1 dicloroetano, 1,2 dicloroetano, clorobenceno, 1,3 dicloropropeno y hexacloro 1,3 butadieno mediante procesos de carbón activo granular y de oxidación avanzada. LI 3 “Plantas portátiles”: Investigación sobre plantas existentes portátiles para verificar su rendimiento teórico y proponer mejoras. Estas líneas de investigación se desarrollaron tanto en el nivel teórico como en el empírico, bien sea en laboratorio como en campo. A lo largo del documento se demuestra que las principales fuentes de contaminación, salvo la degradación de yacimientos naturales, proceden de la actividad humana (efluentes industriales y agrícolas, aguas residuales y actividades beligerantes) que provocan un amplio espectro de enfermedades por lo que dificultan tanto la definición de la fuente como la anticipada detección de la enfermedad. Las principales conclusiones que se obtuvieron están relacionadas con el rendimiento de eliminación de los parámetros tras la aplicación de los procesos y plantas de tratamiento de aguas anteriormente reseñadas. Sin embargo, el verdadero elemento designador de originalidad de esta Tesis Doctoral, tal como se ha reseñado arriba, radica en la definición de un sistema seriado de procesos de tratamiento de aguas que asegura la calidad en caso de emergencia. Éste se define en el siguiente orden: pretratamiento, oxidación, coagulación-floculación-decantación, filtración por arena, intercambio iónico, carbón activo granular, microfiltración, radiación UV, ósmosis inversa, radiación UV y cloración final. The main objective of this Thesis is to obtain a chain of stepwise safe water treatments that allow us to ensure the quality of water for human consumption in case of emergencies, so that the effects of hostile actions, such as sabotage or terrorism, natural disasters, etc. and seek appropriate solutions in this case to ensure health. The existing commercial water treatment plants do not ensure quality, and the documentation on the subject presents knowledge gaps or contradictions. These gaps allow us to determine the issues to be discussed during the investigation. Therefore, this objective was manifested in three actions: Researching yields in commercial plants and microorganisms, or toxic and dangerous products removal. Improvements to ensure the performance of conventional plants. Inquire about the advisability of implementing existing facilities for safety and health guarantee. And three lines of research are developed: LI 1 “Inorganic elements”: Research removing metals iron, copper and molybdenum by ion exchange processes and coagulation-flocculation-decantation. LI 2 “Volatile Organic Compounds”: Research removing organic compounds 1,1 dichloroethane, 1,2 dichloroethane, chlorobenzene, 1,3-dichloropropene and 1,3-butadiene hexachloro through processes of granular activated carbon and advanced oxidation. LI 3 “Compact Water Treatment Plants”: Research on existing packaged plants to verify theoretical performance and suggest improvements. These lines of research are developed both theoretically and empirically, both in the laboratory and in the field. Throughout the document, it is evident that the main sources of pollution, other than the degradation of natural deposits, come from human activity (industrial and agricultural effluents, sewage and belligerent activities) which cause a broad spectrum of diseases which hamper both the definition of the source and the early detection of the disease. The main conclusions drawn are related to both the removal efficiency parameters after application of processes and treatment plants outlined above water. However, the real designator of originality of this thesis, such as outlined above, lies in the definition of a serial system water treatment processes assuring quality in case of emergency. This is defined in the following order: pretreatment, oxidation, coagulation-flocculation-sedimentation, sand filtration, ion exchange, granular activated carbon, microfiltration, UV radiation, reverse osmosis, UV radiation and final chlorination.
Resumo:
La reutilización de efluentes depurados siempre ha sido una opción en lugares con déficit coyuntural o estructural de recursos hídricos, se haya o no procedido a la regulación y planificación de esta práctica. La necesidad se crea a partir de las demandas de una zona, normalmente riego agrícola, que ven un mejor desarrollo de su actividad por contar con este recurso. España es el país de la UE que más caudal reutiliza, y está dentro de los diez primeros a nivel mundial. La regulación de esta práctica por el RD 1620/2007, ayudó a incorporar la reutilización de efluentes depurados a la planificación hidrológica como parte de los programas de medidas, con objeto de mitigar presiones, como son las extracciones de agua superficial y subterránea, o mejoras medioambientales evitando un vertido. El objeto de este trabajo es conocer la situación de la reutilización de efluentes depurados en España, los diferentes escenarios y planteamientos de esta actividad, el desarrollo del marco normativo y su aplicabilidad, junto a los tratamientos que permiten alcanzar los límites de calidad establecidos en la normativa vigente, en función de los distintos usos. Además, se aporta un análisis de costes de las distintas unidades de tratamiento y tipologías de líneas de regeneración, tanto de las utilizadas después de un tratamiento secundario como de otras opciones de depuración, como son los biorreactores de membrana (MBRs). Para el desarrollo de estos objetivos, en primer lugar, se aborda el conocimiento de la situación de la reutilización en España a través de una base de datos diseñada para cubrir todos los aspectos de esta actividad: datos de la estación depuradora de aguas residuales (EDAR), de la estación regeneradora (ERA), caudales depurados, reutilizados, volúmenes utilizados y ubicación de los distintos usos, tipos de líneas de tratamiento, calidades del agua reutilizada, etc. Las principales fuentes de información son las Confederaciones Hidrográficas (CCHH) a través de las concesiones de uso del agua depurada, las entidades de saneamiento y depuración de las distintas comunidades autónomas (CCAA), ayuntamientos, Planes Hidrológicos de Cuenca (PHC) y visitas a las zonas más emblemáticas. Además, se revisan planes y programas con el fin de realizar una retrospectiva de cómo se ha ido consolidando y desarrollando esta práctica en las distintas zonas de la geografía española. Se han inventariado 322 sistemas de reutilización y 216 tratamientos de regeneración siendo el más extendido la filtración mediante filtro arena seguido de una desinfección mediante hipoclorito, aunque este tratamiento se ha ido sustituyendo por un físico-químico con decantación lamelar, filtro de arena y radiación ultravioleta, tratamiento de regeneración convencional (TRC), y otros tratamientos que pueden incluir membranas, tratamientos de regeneración avanzados (TRA), con dosificación de hipoclorito como desinfección residual, para adaptarse al actual marco normativo. El uso más extendido es el agrícola con el 70% del caudal total reutilizado, estimado en 408 hm3, aunque la capacidad de los tratamientos de regeneración esperada para 2015, tras el Plan Nacional de Reutilización de Aguas (PNRA), es tres veces superior. Respecto al desarrollo normativo, en las zonas donde la reutilización ha sido pionera, las administraciones competentes han ido desarrollando diferentes recomendaciones de calidad y manejo de este tipo de agua. El uso agrícola, y en zonas turísticas, el riego de campos de golf, fueron los dos primeros usos que tuvieron algún tipo de recomendación incluso reglamentación. Esta situación inicial, sin una normativa a nivel estatal ni recomendaciones europeas, creó cierta incertidumbre en el avance de la reutilización tanto a nivel de concesiones como de planificación. En la actualidad sigue sin existir una normativa internacional para la reutilización y regeneración de efluentes depurados. Las recomendaciones de referencia a nivel mundial, y en concreto para el uso agrícola, son las de la OMS (Organización Mundial de la Salud) publicadas 1989, con sus posteriores revisiones y ampliaciones (OMS, 2006). Esta norma combina tratamientos básicos de depuración y unas buenas prácticas basadas en diferentes niveles de protección para evitar problemas sanitarios. Otra normativa que ha sido referencia en el desarrollo del marco normativo en países donde se realiza esta práctica, son las recomendaciones dadas por la Agencia Medioambiente Estadunidense (USEPA, 2012) o las publicadas por el Estado de California (Título 22, 2001). Estas normas establecen unos indicadores y valores máximos dónde el tratamiento de regeneración es el responsable de la calidad final en función del uso. Durante 2015, la ISO trabajaba en un documento para el uso urbano donde se muestra tanto los posibles parámetros que habría que controlar como la manera de actuar para evitar posibles riesgos. Por otro lado, la Comisión Europea (CE) viene impulsando desde el 2014 la reutilización de aguas depuradas dentro del marco de la Estrategia Común de Implantación de la Directiva Marco del Agua, y fundamentalmente a través del grupo de trabajo de “Programas de medidas”. Para el desarrollo de esta iniciativa se está planteando sacar para 2016 una guía de recomendaciones que podría venir a completar el marco normativo de los distintos Estados Miembros (EM). El Real Decreto 1620/2007, donde se establece el marco jurídico de la reutilización de efluentes depurados, tiende más a la filosofía implantada por la USEPA, aunque la UE parece más partidaria de una gestión del riesgo, donde se establecen unos niveles de tolerancia y unos puntos de control en función de las condiciones socioeconómicas de los distintos Estados, sin entrar a concretar indicadores, valores máximos o tratamientos. Sin embargo, en la normativa estadounidense se indican una serie de tratamientos de regeneración, mientras que, en la española, se hacen recomendaciones a este respecto en una Guía sin validez legal. Por tanto, queda sin regular los procesos para alcanzar estos estándares de calidad, pudiendo ser éstos no apropiados para esta práctica. Es el caso de la desinfección donde el uso de hipoclorito puede generar subproductos indeseables. En la Guía de recomendaciones para la aplicación del RD, publicada por el Ministerio de Agricultura y Medioambiente (MAGRAMA) en 2010, se aclaran cuestiones frecuentes sobre la aplicación del RD, prescripciones técnicas básicas para los sistemas de reutilización, y buenas prácticas en función del uso. Aun así, el RD sigue teniendo deficiencias en su aplicación siendo necesaria una revisión de la misma, como en las frecuencias de muestreo incluso la omisión de algunos parámetros como huevos de nematodos que se ha demostrado ser inexistentes tras un tratamiento de regeneración convencional. En este sentido, existe una tendencia a nivel mundial a reutilizar las aguas con fines de abastecimiento, incluir indicadores de presencia de virus o protozoos, o incluir ciertas tecnologías como las membranas u oxidaciones avanzadas para afrontar temas como los contaminantes emergentes. Otro de los objetivos de este trabajo es el estudio de tipologías de tratamiento en función de los usos establecidos en el RD 1620/2007 y sus costes asociados, siendo base de lo establecido a este respecto en la Guía y PNRA anteriormente indicados. Las tipologías de tratamiento propuestas se dividen en líneas con capacidad de desalar y las que no cuentan con una unidad de desalación de aguas salobres de ósmosis inversa o electrodiálisis reversible. Se realiza esta división al tener actuaciones en zonas costeras donde el agua de mar entra en los colectores, adquiriendo el agua residual un contenido en sales que es limitante en algunos usos. Para desarrollar este objetivo se han estudiado las unidades de tratamiento más implantadas en ERAs españolas en cuanto a fiabilidad para conseguir determinada calidad y coste, tanto de implantación como de explotación. El TRC, tiene un coste de implantación de 28 a 48 €.m-3.d y de explotación de 0,06 a 0,09 €. m-3, mientras que, si se precisara desalar, este coste se multiplica por diez en la implantación y por cinco en la explotación. En caso de los usos que requieren de TRA, como los domiciliarios o algunos industriales, los costes serían de 185 a 398 €.m-3.d en implantación y de 0,14 a 0,20 €.m-3 en explotación. En la selección de tecnologías de regeneración, la capacidad del tratamiento en relación al coste es un indicador fundamental. Este trabajo aporta curvas de tendencia coste-capacidad que sirven de herramienta de selección frente a otros tratamientos de regeneración de reciente implantación como son los MBR, u otros como la desalación de agua de mar o los trasvases entre cuencas dentro de la planificación hidrológica. En España, el aumento de las necesidades de agua de alta calidad en zonas con recursos escasos, aumento de zonas sensibles como puntos de captación para potables, zonas de baño o zonas de producción piscícola, y en ocasiones, el escaso terreno disponible para la implantación de nuevas plantas depuradoras (EDARs), han convertido a los MBRs, en una opción dentro del marco de la reutilización de aguas depuradas. En este trabajo, se estudia esta tecnología frente a los TRC y TRA, aportando igualmente curvas de tendencia coste-capacidad, e identificando cuando esta opción tecnológica puede ser más competitiva frente a los otros tratamientos de regeneración. Un MBR es un tratamiento de depuración de fangos activos donde el decantador secundario es sustituido por un sistema de membranas de UF o MF. La calidad del efluente, por tanto, es la misma que el de una EDAR seguida de un TRA. Los MBRs aseguran una calidad del efluente para todos los usos establecidos en el RD, incluso dan un efluente que permite ser directamente tratado por las unidades de desalación de OI o EDR. La implantación de esta tecnología en España ha tenido un crecimiento exponencial, pasando de 13 instalaciones de menos de 5.000 m3. d-1 en el 2006, a más de 55 instalaciones en operación o construcción a finales del 2014, seis de ellas con capacidades por encima de los 15.000 m3. d-1. Los sistemas de filtración en los MBR son los que marcan la operación y diseño de este tipo de instalaciones. El sistema más implantado en España es de membrana de fibra hueca (MFH), sobre todo para instalaciones de gran capacidad, destacando Zenon que cuenta con el 57% de la capacidad total instalada. La segunda casa comercial con mayor número de plantas es Kubota, con membranas de configuración placa plana (MPP), que cuenta con el 30 % de la capacidad total instalada. Existen otras casas comerciales implantadas en MBR españoles como son Toray, Huber, Koch o Microdym. En este documento se realiza la descripción de los sistemas de filtración de todas estas casas comerciales, aportando información de sus características, parámetros de diseño y operación más relevantes. El estudio de 14 MBRs ha posibilitado realizar otro de los objetivos de este trabajo, la estimación de los costes de explotación e implantación de este tipo de sistemas frente a otras alternativas de tratamiento de regeneración. En este estudio han participado activamente ACA y ESAMUR, entidades públicas de saneamiento y depuración de Cataluña y Murcia respectivamente, que cuentan con una amplia experiencia en la explotación de este tipo de sistemas. Este documento expone los problemas de operación encontrados y sus posibles soluciones, tanto en la explotación como en los futuros diseños de este tipo de plantas. El trabajo concluye que los MBRs son una opción más para la reutilización de efluentes depurados, siendo ventajosos en costes, tanto de implantación como de explotación, respecto a EDARs seguidas de TRA en capacidades por encima de los 10.000 m3.d-1. ABSTRACT The reuse of treated effluent has always been an option in places where a situational or structural water deficit exists, whether regulatory and/or planning efforts are completed or not. The need arises from the demand of a sector, commonly agricultural irrigation, which benefits of this new resource. Within the EU, Spain is ahead in the annual volume of reclaimed water, and is among the top ten countries at a global scale. The regulation of this practice through the Royal Decree 1620/2007 has helped to incorporate the water reuse to the hydrological plans as a part of the programme of measures to mitigate pressures such as surface or ground water extraction, or environmental improvements preventing discharges. The object of this study is to gain an overview of the state of the water reuse in Spain, the different scenarios and approaches to this activity, the development of the legal framework and its enforceability, together with the treatments that achieve the quality levels according to the current law, broken down by applications. Additionally, a cost analysis of technologies and regeneration treatment lines for water reclamation is performed, whereas the regeneration treatment is located after a wastewater treatment or other options such as membrane bioreactors (MBR). To develop the abovementioned objectives, the state of water reuse in Spain is studied by means of a database designed to encompass all aspects of the activity: data from the wastewater treatment plants (WWTP), from the water reclamation plants (WRP), the use of reclaimed water, treated water and reclaimed water annual volumes and qualities, facilities and applications, geographic references, technologies, regeneration treatment lines, etc. The main data providers are the River Basin authorities, through the concession or authorization for water reuse, (sanitary and wastewater treatment managers from the territorial governments, local governments, Hydrological Plans of the River Basins and field visits to the main water reuse systems. Additionally, a review of different plans and programmes on wastewater treatment or water reuse is done, aiming to put the development and consolidation process of this activity in the different regions of Spain in perspective. An inventory of 322 reuse systems and 216 regeneration treatments has been gathered on the database, where the most extended regeneration treatment line was sand filtration followed by hypochlorite disinfection, even though recently it is being replaced by physical–chemical treatment with a lamella settling system, depth sand filtration, and a disinfection with ultraviolet radiation and hypochlorite as residual disinfectant, named conventional regeneration treatment (CRT), and another treatment that may include a membrane process, named advanced regeneration treatment (ART), to adapt to legal requirements. Agricultural use is the most extended, accumulating 70% of the reclaimed demand, estimated at 408 hm3, even though the expected total capacity of WRPs for 2015, after the implementation of the National Water Reuse Plan (NWRP) is three times higher. According to the development of the water reuse legal framework, there were pioneer areas where competent authorities developed different quality and use recommendations for this new resource. Agricultural use and golf course irrigation in touristic areas were the first two uses with recommendations and even legislation. The initial lack of common legislation for water reuse at a national or European level created some doubts which affected the implementation of water reuse, both from a planning and a licensing point of view. Currently there is still a lack of common international legislation regarding water reuse, technologies and applications. Regarding agricultural use, the model recommendations at a global scale are those set by the World Health Organization published in 1989, and subsequent reviews and extensions about risk prevention (WHO, 2006). These documents combine wastewater treatments with basic regeneration treatments reinforced by good practices based on different levels of protection to avoid deleterious health effects. Another relevant legal reference for this practices has been the Environmental Protection Agency of the US (USEPA, 2012), or those published by the State of California (Title 22, 2001). These establish indicator targets and maximum thresholds where regeneration treatment lines are responsible for the final quality according to the different uses. During 2015, the ISO has worked on a document aimed at urban use, where the possible parameters to be monitored together with risk prevention have been studied. On the other hand, the European Commission has been promoting the reuse of treated effluents within the Common Implementation Strategy of the Water Framework Directive, mainly through the work of the Programme of Measures Working Group. Within this context, the publication of a recommendation guide during 2016 is intended, as a useful tool to fill in the legal gaps of different Member States on the matter. The Royal Decree 1620/2007, where the water reuse regulation is set, resembles the principles of the USEPA more closely, even though the EU shows a tendency to prioritize risk assessment by establishing tolerance levels and thresholds according to socioeconomic conditions of the different countries, without going into details of indicators, maximum thresholds or treatments. In contrast, in the US law, regeneration treatments are indicated, while in the Spanish legislation, the only recommendations to this respect are compiled in a non-compulsory guide. Therefore, there is no regulation on the different treatment lines used to achieve the required quality standards, giving room for inappropriate practices in this respect. This is the case of disinfection, where the use of hypochlorite may produce harmful byproducts. In the recommendation Guide for the application of the Royal Decree (RD), published by the Ministry of Agriculture and Environment (MAGRAMA) in 2010, clarifications of typical issues that may arise from the application of the RD are given, as well as basic technical parameters to consider in reuse setups, or good practices according to final use. Even so, the RD still presents difficulties in its application and requires a review on issues such as the sampling frequency of current quality parameters or even the omission of nematode eggs indicator, which have been shown to be absent after CRT. In this regard, there is a global tendency to employ water reuse for drinking water, including indicators for the presence of viruses and protozoans, or to include certain technologies such as membranes or advanced oxidation processes to tackle problems like emerging pollutants. Another of the objectives of this study is to provide different regeneration treatment lines to meet the quality requirements established in the RD 1620/2007 broken down by applications, and to estimate establishment and operational costs. This proposal has been based on what is established in the above mentioned Guide and NWRP. The proposed treatment typologies are divided in treatment trains with desalination, like reverse osmosis or reversible electrodialisis, and those that lack this treatment for brackish water. This separation is done due to coastal facilities, where sea water may permeate the collecting pipes, rising salt contents in the wastewater, hence limiting certain uses. To develop this objective a study of the most common treatment units set up in Spanish WRPs is conducted in terms of treatment train reliability to obtain an acceptable relationship between the required quality and the capital and operational costs. The CRT has an establishment cost of 28 to 48 €.m-3.d and an operation cost of 0.06 to 0.09 €.m-3, while, if desalination was required, these costs would increase tenfold for implementation and fivefold for operation. In the cases of uses that require ART, such as residential or certain industrial uses, the costs would be of 185 to 398 €.m-3.d for implementation and of 0.14 to 0.20 €.m-3 for operation. When selecting regeneration treatment lines, the relation between treatment capacity and cost is a paramount indicator. This project provides cost-capacity models for regeneration treatment trains. These may serve as a tool when selecting between different options to fulfill water demands with MBR facilities, or others such as sea water desalination plants or inter-basin water transfer into a water planning framework. In Spain, the requirement for high quality water in areas with low resource availability, the increasing number of sensitive zones, such as drinking water extraction, recreational bathing areas, fish protected areas and the lack of available land to set up new WWTPs, have turned MBRs into a suitable option for water reuse. In this work this technology is analyzed in contrast to CRT and ART, providing cost-capacity models, and identifying when and where this treatment option may outcompete other regeneration treatments. An MBR is an activated sludge treatment where the secondary settling is substituted by a membrane system of UF or MF. The quality of the effluent is, therefore, comparable to that of a WWTP followed by an ART. MBRs ensure a sufficient quality level for the requirements of the different uses established in the RD, even producing an effluent that can be directly treated in OI or EDR processes. The implementation of this technology in Spain has grown exponentially, growing from 13 facilities with less than 5000 m3.d-1 in 2006 to above 55 facilities operating by the end of 2014, 6 of them with capacities over 15000 m3.d-1. The membrane filtration systems for MBR are the ones that set the pace of operation and design of this type of facilities. The most widespread system in Spain is the hollow fiber membrane configuration, especially on high flow capacities, being Zenon commercial technology, which mounts up to 57% of the total installed capacity, the main contributor. The next commercial technology according to plant number is Kubota, which uses flat sheet membrane configuration, which mounts up to 30% of the total installed capacity. Other commercial technologies exist within the Spanish MBR context, such as Toray, Huber, Koch or Microdym. In this document an analysis of all of these membrane filtration systems is done, providing information about their characteristics and relevant design and operation parameters. The study of 14 full scale running MBRs has enabled to pursue another of the objectives of this work: the estimation of the implementation and operation costs of this type of systems in contrast to other regeneration alternatives. Active participation of ACA and ESAMUR, public wastewater treatment and reuse entities of Cataluña and Murcia respectively, has helped attaining this objective. A number of typical operative problems and their possible solutions are discussed, both for operation and plant design purposes. The conclusion of this study is that MBRs are another option to consider for water reuse, being advantageous in terms of both implementation and operational costs, when compared with WWTPs followed by ART, when considering flow capacities above 10000 m3.d-1.
Resumo:
Os Planos de Segurança da Água surgem com a necessidade de aumentar a segurança da água de abastecimento, superando a monitorização de conformidade de “fim de linha”, permitindo aumentar a confiança do consumidor na qualidade da água que lhe é fornecida. Esta nova abordagem recorre a uma metodologia de gestão baseada na identificação e no controlo de riscos em pontos críticos de um sistema de abastecimento, em complemento do controlo realizado através da monitorização da conformidade da água entregue aos consumidores. O Plano de Segurança da Água (PSA) encontra-se implementado no Sistema Regional do Carvoeiro (SRC) desde o ano de 2009. O SRC é um sistema de abastecimento de água em alta, sendo constituído por conjunto de infraestruturas de captação, tratamento, transporte e armazenamento de água desde a sua origem, localizada no rio Vouga, em Carvoeiro, até aos municípios integrados na Associação de Municípios do Carvoeiro-Vouga. Atendendo à obra de expansão do SRC, tornou-se imperativo efetuar uma revisão ao PSA, sendo este o objetivo primordial do trabalho de estágio desenvolvido na empresa Águas do Vouga S.A, concessionária responsável pela gestão do SRC. Para a prossecução deste objetivo, o trabalho desenvolvido envolveu os seguintes passos metodológicos: identificação das operações aplicadas no SRC; identificação de perigos e eventos perigosos em todos os órgãos constituintes do sistema; avaliação de riscos; identificação de pontos críticos de controlo; identificação de pontos de monitorização e medidas preventivas; elaboração do plano de monitorização, incluindo, procedimentos de controlo operacional em condições normais de funcionamento e em caso de desvio; validação deste plano. Deste trabalho resultou a identificação de 166 eventos perigosos, 17 tipologias de perigos, 3 pontos de controlo crítico e 17 pontos de monitorização. Os pontos de controlo crítico foram identificados nos processos de tratamento da ETA do Carvoeiro. O primeiro foi localizado na etapa de filtração com areia, antracite e zeólitos correspondendo aos perigos com metais (Fe e Mn), outros compostos químicos perigosos, partículas, turvação, matéria orgânica e alumínio. O segundo ponto foi identificado na etapa de filtração com filtros de carvão ativado granular relativo ao aparecimento de sabor e cianotoxinas. O terceiro ponto de controlo crítico foi encontrado na etapa de desinfeção referente aos microrganismos patogénicos. Os pontos de monitorização foram localizados ao longo do sistema em situações onde não se dispõem de nenhuma medida de controlo para eliminar o perigo e antes e após os pontos de controlo crítico. O plano de monitorização foi desenvolvido para estes pontos, embora os limites e procedimentos definidos devam ser alvo de revisão após a conclusão da obra de expansão do sistema. A validação da revisão do plano foi iniciada, mas cingiu-se apenas na avaliação preliminar de riscos, prévia ao início de operação da ETA do Carvoeiro. Para além da revisão deste plano, foram realizadas outras tarefas, nomeadamente uma análise à qualidade da água fornecida e distribuída pelo sistema, a elaboração do plano PCQA para o ano de 2016, a configuração da plataforma de gestão operacional NAVIATM e a revisão do Manual de Gestão da Águas do Vouga relativo ao processo de qualidade na captação, tratamento e distribuição e ao processo de qualidade na gestão do PSA.
Resumo:
OBJECTIVE: Blood-sucking arthropods' salivary glands contain a remarkable diversity of antihemostatics. The aim of the present study was to identify the unique salivary anticoagulant of the sand fly Lutzomyia longipalpis, which remained elusive for decades. METHODS AND RESULTS: Several L. longipalpis salivary proteins were expressed in human embryonic kidney 293 cells and screened for inhibition of blood coagulation. A novel 32.4-kDa molecule, named Lufaxin, was identified as a slow, tight, noncompetitive, and reversible inhibitor of factor Xa (FXa). Notably, Lufaxin's primary sequence does not share similarity to any physiological or salivary inhibitors of coagulation reported to date. Lufaxin is specific for FXa and does not interact with FX, Dansyl-Glu-Gly-Arg-FXa, or 15 other enzymes. In addition, Lufaxin blocks prothrombinase and increases both prothrombin time and activated partial thromboplastin time. Surface plasmon resonance experiments revealed that FXa binds Lufaxin with an equilibrium constant ≈3 nM, and isothermal titration calorimetry determined a stoichiometry of 1:1. Lufaxin also prevents protease-activated receptor 2 activation by FXa in the MDA-MB-231 cell line and abrogates edema formation triggered by injection of FXa in the paw of mice. Moreover, Lufaxin prevents FeCl(3)-induced carotid artery thrombus formation and prolongs activated partial thromboplastin time ex vivo, implying that it works as an anticoagulant in vivo. Finally, salivary gland of sand flies was found to inhibit FXa and to interact with the enzyme. CONCLUSIONS: Lufaxin belongs to a novel family of slow-tight FXa inhibitors, which display antithrombotic and anti-inflammatory activities. It is a useful tool to understand FXa structural features and its role in prohemostatic and proinflammatory events.
Resumo:
Clogging, measured through head loss across filters, and the filtration quality of different filters using different effluents were studied. The filters used were: 115, 130, and 200 m disc filters; 98, 115, 130, and 178 m screen filters; and a sand filter filled with a single layer of sand with an effective diameter of 0.65 mm. The filters were used with a meat industry effluent and secondary and tertiary effluents of two wastewater treatment plants. It was observed that clogging depended on the type of effluent. With the meat industry effluent, the poorest quality effluent, disc filters clogged more than the other filter types. When the wastewater treatment plant effluents were used, the disc filters showed less frequent clogging. Several physical and chemical parameters, such as total suspended solids, chemical oxygen demand, turbidity, electrical conductivity, pH, and number of particles, were analyzed in the effluents at the entry and exit points of the filters. In general, filters did not reduce the values of the main clogging parameters to a great degree. It was found that the parameter that explained the clogging, expressed as Boucher’s filterability index, was different depending on the type of effluent and filter. The best quality of filtration was achieved with a sand filter when the meat industry effluent was used. No significant differences were observed between the quality of filtration of disc and screen filters when operating with the secondary and tertiary effluents
Resumo:
It is often assumed that total head losses in a sand filter are solely due to the filtration media and that there are analytical solutions, such as the Ergun equation, to compute them. However, total head losses are also due to auxiliary elements (inlet and outlet pipes and filter nozzles), which produce undesirable head losses because they increase energy requirements without contributing to the filtration process. In this study, ANSYS Fluent version 6.3, a commercial computational fluid dynamics (CFD) software program, was used to compute head losses in different parts of a sand filter. Six different numerical filter models of varying complexities were used to understand the hydraulic behavior of the several filter elements and their importance in total head losses. The simulation results show that 84.6% of these were caused by the sand bed and 15.4% were due to auxiliary elements (4.4% in the outlet and inlet pipes, and 11.0% in the perforated plate and nozzles). Simulation results with different models show the important role of the nozzles in the hydraulic behavior of the sand filter. The relationship between the passing area through the nozzles and the passing area through the perforated plate is an important design parameter for the reduction of total head losses. A reduced relationship caused by nozzle clogging would disproportionately increase the total head losses in the sand filter
Resumo:
This study presents an evaluation of a pilot multistage filtration system (MSF) with different dosages, 131 mg L-1 and 106 mg L-1, of the natural coagulant extracted from Moringa oleifera seeds in pre-filtration and slow filtration stages, respectively. The system was comprised by a dynamic pre-filter unit, two upflow filters in parallel and four slow filters in parallel, and in one of the four filters had the filter media altered. The performance of the system was evaluated by monitoring some water quality parameters such as: turbidity, apparent color and slow filter load loss. The stages that have received the coagulant solution had better treatment efficiency compared with the steps without it. However, the direct application of the coagulant solution in the slow filter caused rapid clogging of the non-woven blanket and shorter career length.
Resumo:
Objective-Blood-sucking arthropods' salivary glands contain a remarkable diversity of antihemostatics. The aim of the present study was to identify the unique salivary anticoagulant of the sand fly Lutzomyia longipalpis, which remained elusive for decades. Methods and Results-Several L. longipalpis salivary proteins were expressed in human embryonic kidney 293 cells and screened for inhibition of blood coagulation. A novel 32.4-kDa molecule, named Lufaxin, was identified as a slow, tight, noncompetitive, and reversible inhibitor of factor Xa (FXa). Notably, Lufaxin's primary sequence does not share similarity to any physiological or salivary inhibitors of coagulation reported to date. Lufaxin is specific for FXa and does not interact with FX, Dansyl-Glu-Gly-Arg-FXa, or 15 other enzymes. In addition, Lufaxin blocks prothrombinase and increases both prothrombin time and activated partial thromboplastin time. Surface plasmon resonance experiments revealed that FXa binds Lufaxin with an equilibrium constant approximate to 3 nM, and isothermal titration calorimetry determined a stoichiometry of 1:1. Lufaxin also prevents protease-activated receptor 2 activation by FXa in the MDA-MB-231 cell line and abrogates edema formation triggered by injection of FXa in the paw of mice. Moreover, Lufaxin prevents FeCl3-induced carotid artery thrombus formation and prolongs activated partial thromboplastin time ex vivo, implying that it works as an anticoagulant in vivo. Finally, salivary gland of sand flies was found to inhibit FXa and to interact with the enzyme. Conclusion-Lufaxin belongs to a novel family of slow-tight FXa inhibitors, which display antithrombotic and anti-inflammatory activities. It is a useful tool to understand FXa structural features and its role in prohemostatic and proinflammatory events. (Arterioscler Thromb Vasc Biol. 2012;32:2185-2196.)
Resumo:
This work used the colloidal theory to describe forces and energy interactions of colloidal complexes in the water and those formed during filtration run in direct filtration. Many interactions of particle energy profiles between colloidal surfaces for three geometries are presented here in: spherical, plate and cylindrical; and four surface interactions arrangements: two cylinders, two spheres, two plates and a sphere and a plate. Two different situations were analyzed, before and after electrostatic destabilization by action of the alum sulfate as coagulant in water studies samples prepared with kaolin. In the case were used mathematical modeling by extended DLVO theory (from the names: Derjarguin-Landau-Verwey-Overbeek) or XDLVO, which include traditional approach of the electric double layer (EDL), surfaces attraction forces or London-van der Waals (LvdW), esteric forces and hydrophobic forces, additionally considering another forces in colloidal system, like molecular repulsion or Born Repulsion and Acid-Base (AB) chemical function forces from Lewis.
Resumo:
Reduction in global ocean pH due to the uptake of increased atmospheric CO2 is expected to negatively affect calcifying organisms, including the planktonic larval stages of many marine invertebrates. Planktonic larvae play crucial roles in the benthic-pelagic life cycle of marine organisms by connecting and sustaining existing populations and colonizing new habitats. Calcified larvae are typically denser than seawater and rely on swimming to navigate vertically structured water columns. Larval sand dollars Dendraster excentricus have calcified skeletal rods supporting their bodies, and propel themselves with ciliated bands looped around projections called arms. Ciliated bands are also used in food capture, and filtration rate is correlated with band length. As a result, swimming and feeding performance are highly sensitive to morphological changes. When reared at an elevated PCO2 level (1000 ppm), larval sand dollars developed significantly narrower bodies at four and six-arm stages. Morphological changes also varied between four observed maternal lineages, suggesting within-population variation in sensitivity to changes in PCO2 level. Despite these morphological changes, PCO2 concentration alone had no significant effect on swimming speeds. However, acidified larvae had significantly smaller larval stomachs and bodies, suggesting reduced feeding performance. Adjustments to larval morphologies in response to ocean acidification may prioritize swimming over feeding, implying that negative consequences of ocean acidification are carried over to later developmental stages.
Resumo:
In the current study, a new approach has been developed for correcting the effect that moisture reduction after virgin olive oil (VOO) filtration exerts on the apparent increase of the secoiridoid content by using an internal standard during extraction. Firstly, two main Spanish varieties (Picual and Hojiblanca) were submitted to industrial filtration of VOOs. Afterwards, the moisture content was determined in unfiltered and filtered VOOs, and liquid-liquid extraction of phenolic compounds was performed using different internal standards. The resulting extracts were analyzed by HPLC-ESI-TOF/MS, in order to gain maximum information concerning the phenolic profiles of the samples under study. The reduction effect of filtration on the moisture content, phenolic alcohols, and flavones was confirmed at the industrial scale. Oleuropein was chosen as internal standard and, for the first time, the apparent increase of secoiridoids in filtered VOO was corrected, using a correction coefficient (Cc) calculated from the variation of internal standard area in filtered and unfiltered VOO during extraction. This approach gave the real concentration of secoiridoids in filtered VOO, and clarified the effect of the filtration step on the phenolic fraction. This finding is of great importance for future studies that seek to quantify phenolic compounds in VOOs.
Resumo:
studies have shown that rate of propofol infusion may influence the predicted propofol concentration at the effect site (Es). The aim of this study was to evaluate the Es predicted by the Marsh pharmacokinetic model (ke0 0.26min(-1)) in loss of consciousness during fast or slow induction. the study included 28 patients randomly divided into two equal groups. In slow induction group (S), target-controlled infusion (TCI) of propofol with plasma, Marsh pharmacokinetic model (ke0 0.26min(-1)) with target concentration (Tc) at 2.0-μg.mL(-1) were administered. When the predicted propofol concentration at the effect site (Es) reached half of Es value, Es was increased to previous Es + 1μg.mL(-1), successively, until loss of consciousness. In rapid induction group (R), patients were induced with TCI of propofol with plasma (6.0μg.ml(-1)) at Es, and waited until loss of consciousness. in rapid induction group, Tc for loss of consciousness was significantly lower compared to slow induction group (1.67±0.76 and 2.50±0.56μg.mL(-1), respectively, p=0.004). the predicted propofol concentration at the effect site for loss of consciousness is different for rapid induction and slow induction, even with the same pharmacokinetic model of propofol and the same balance constant between plasma and effect site.
Resumo:
The application of sand filters in localized irrigation systems is recommended in the presence of organic and algae contamination. The proper design and maintenance of these equipments are essential to assure an effective water quality control, in order to reduce the emitters clogging, to keep its water application uniformity, and to prevent increasing in the system operation costs. Despite the existence of some references about design, operation and maintenance of these filters, they are dispersed, with not enough details to guarantee the optimization of its hydraulics structure design and the proper selection of porous media to be used. Therefore, the objective of this work was to report a current literature review, relating practical information with scientific knowledge. The content of this review would help to induce and intensify the research on this subject and to contribute so the operational functions for the equipment are reached. It is also expected to assist the improvement of the filtration and flushing processes in the agricultural irrigation and the development of original design procedures and the rational use of these devices.