903 resultados para Six minutes walk test


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: A better physical fitness may have survival advantages in adults. Aim: To analyze the relationship between cardiorespiratory fitness and cardiovascular risk factors among obese subjects aged 58 years and older. Material and Methods: Cardiorespiratory fitness using the six-minute walk test, body composition by dual-energy x-ray absorptiometry and blood pressure were measured in a non-representative sample of 76 obese Portuguese subjects aged 58 to 87 years (55 women). Participants were stratified in tertiles of walking capacity according to the six-minute walk test. Results: Six minutes walk test results were negatively correlated with percentage body fat (r = -0.28; p = 0.012) and systolic blood pressure (r = -0.23; p = 0.045). Participants located in the lowest tertile for the six minutes walk test had an odds ratio of 4.34 (95% confidence intervals: 1.02-18.43) for elevated blood pressure. Conclusions: A lower six minutes walk test result is associated with a higher risk for high blood pressure. (Rev Med Chile 2012; 140: 1164-1169).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction:The regular practice of physical activity is being used as a therapeutic resource to the elderly population, with the objective of reduction of the losses provoked by the growing old process. The home place (urban or rural) is still little explored in literature about your infl uence in the physical capacity of the elderly people. Objective: The aim of this study was to value and compare the quality of life, motion and functional capacity between physically active and sedentary elderly people, residents in the urban and rural area. Methods: Sixty people with age above 60 years old were valued, 20 physically active residents in the urban area (66,5 ± 4,32 years), 20 sedentary residents in the urban area (68,8± 7,24 years), 10 physically active residents in the rural area (64,4±2,46 years) and 10 sedentary residents in the rural area (68±5,78 years). It was realized the evaluation of the fl exibility (previous fl exon of the trunk), mobility (timed up and go test), a six-minute walk test and answered a quality of life’s questionnaire SF-36. To compare the results obtained by the two groups was used the Kruskal-Wallis test, and the signifi cant presence of the test was performed post hoc Newman-Keuls. The level of signifi cance used in statistical analysis was 5% (p<0,05).Results: It was observed that the physically active elderly people obtaine better performance on the six-minutes walk test. It wasn’t found difference in the mobility among the groups. In relation to the quality of life, the elderly residents in the rural area, were better in the component Vitally. In relation to the fl exibility the elderly residents in the urban area obtained the best results. So, we can conclude that the practice of physical activity realized by the volunteers contributed to a better functional capacity, observed by the biggest distance gone through on the walk test. The rural home place positively infl uenced the vitality control, while the fl exibility was worse presented in these elderly people.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

L’insuffisance cardiaque est une pathologie provoquant une diminution importante des capacités fonctionnelles des patients ainsi qu’une diminution drastique de la qualité de vie. L’évaluation des capacités fonctionnelles est généralement effectuée par une épreuve d’effort maximal. Cependant pour plusieurs patients, cet effort est difficile à compléter. Les objectifs de l’étude présentée dans ce mémoire sont : (1) valider trois méthodes d’évaluation de la capacité fonctionnelle et aérobie des sujets souffrant d’insuffisance cardiaque avec un complexe QRS élargi; (2) chercher à établir le profil des patients démontrant une meilleure tolérance à l’exercice malgré une consommation maximale d’oxygène identique; et (3) démontrer les conséquences de la présence et de la magnitude de l’asynchronisme cardiaque dans la capacité fonctionnelle et la tolérance à l’exercice. Tous les sujets ont été soumis à un test de marche de six minutes, un test d’endurance à charge constante sur tapis roulant et à une épreuve d’effort maximal avec mesure d’échanges gazeux à la bouche. Les résultats ont montré une association significative entre les épreuves maximale et plus spécifiquement sous-maximale. De plus, une meilleure tolérance à l’exercice serait associée significativement à une plus grande masse du ventricule gauche. Finalement, les résultats de notre étude n’ont pas montré d’effet d’un asynchronisme cardiaque sur la performance à l’effort tel qu’évalué par nos protocoles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To test the reliability of Timed Up and Go Tests (TUGTs) in cardiac rehabilitation (CR) and compare TUGTs to the 6-Minute Walk Test (6MWT) for outcome measurement. METHODS: Sixty-one of 154 consecutive community-based CR patients were prospectively recruited. Subjects undertook repeated TUGTs and 6MWTs at the start of CR (start-CR), postdischarge from CR (post-CR), and 6 months postdischarge from CR (6 months post-CR). The main outcome measurements were TUGT time (TUGTT) and 6MWT distance (6MWD). RESULTS: Mean (SD) TUGTT1 and TUGTT2 at the 3 assessments were 6.29 (1.30) and 5.94 (1.20); 5.81 (1.22) and 5.53 (1.09); and 5.39 (1.60) and 5.01 (1.28) seconds, respectively. A reduction in TUGTT occurred between each outcome point (P ≤ .002). Repeated TUGTTs were strongly correlated at each assessment, intraclass correlation (95% CI) = 0.85 (0.76–0.91), 0.84 (0.73–0.91), and 0.90 (0.83–0.94), despite a reduction between TUGTT1 and TUGTT2 of 5%, 5%, and 7%, respectively (P ≤ .006). Relative decreases in TUGTT1 (TUGTT2) occurred from start-CR to post-CR and from start-CR to 6 months post-CR of −7.5% (−6.9%) and −14.2% (−15.5%), respectively, while relative increases in 6MWD1 (6MWD2) occurred, 5.1% (7.2%) and 8.4% (10.2%), respectively (P < .001 in all cases). Pearson correlation coefficients for 6MWD1 to TUGTT1 and TUGTT2 across all times were −0.60 and −0.68 (P < .001) and the intraclass correlations (95% CI) for the speeds derived from averaged 6MWDs and TUGTTs were 0.65 (0.54, 0.73) (P < .001). CONCLUSIONS: Similar relative changes occurred for the TUGT and the 6MWT in CR. A significant correlation between the TUGTT and 6MWD was demonstrated, and we suggest that the TUGT may provide a related or a supplementary measurement of functional capacity in CR.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The concurrent validity of a 1 minute walk test at a child's maximum walking speed was assessed in children with bilateral spastic cerebral palsy (BSCP). The distance covered during the 1 minute walk test was compared with the children's gross motor function as assessed by the Gross Motor Function Measure (GMFM). Twenty-four male and 10 female children with CP (mean age 11y, range 4 to 16y) participated in the study. Gross Motor Function Classification System (GMFCS) levels were; level I (n=3), level II (n=17), level III (n=10), and level IV (n=4). Participants had clinical diagnoses of symmetrical diplegia (n=19), asymmetrical diplegia (n=14), and quadriplegia (n=1). Results showed a significant correlation between GMFM score and the distance covered during the 1 minute walk (r=0.92; p<0.001). There was also a significant decrease in the distance walked with increasing GMFCS level (p<0.001). We concluded that the 1 minute walk test is a valid measure for assessing functional ability in children with ambulatory BSCP. Its cost-effectiveness and user friendliness make it a potentially useful tool in the clinical setting. Further study needs to address its reliability and ability to detect change over time.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An international standard, ISO/DP 9459-4 has been proposed to establish a uniform standard of quality for small, factory-made solar heating systerns. In this proposal, system components are tested separatelyand total system performance is calculated using system simulations based on component model parameter values validated using the results from the component tests. Another approach is to test the whole system in operation under representative conditions, where the results can be used as a measure of the general system performance. The advantage of system testing of this form is that it is not dependent on simulations and the possible inaccuracies of the models. Its disadvantage is that it is restricted to the boundary conditions for the test. Component testing and system simulation is flexible, but requires an accurate and reliable simulation model.The heat store is a key component conceming system performance. Thus, this work focuses on the storage system consisting store, electrical auxiliary heater, heat exchangers and tempering valve. Four different storage system configurations with a volume of 750 litre were tested in an indoor system test using a six -day test sequence. A store component test and system simulation was carried out on one of the four configurations, applying the proposed standard for stores, ISO/DP 9459-4A. Three newly developed test sequences for intemalload side heat exchangers, not in the proposed ISO standard, were also carried out. The MULTIPORT store model was used for this work. This paper discusses the results of the indoor system test, the store component test, the validation of the store model parameter values and the system simulations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)