957 resultados para Serological Tests


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Alveolar echinococcosis (AE), caused by larva stage of Echinococcus multilocularis, is one of the lethal parasitic diseases of man and a major public health problem in many countries in the northern hemisphere. When the living conditions and habits in Turkey were considered in terms of relation with the life cycle of the parasite, it was suggested that AE has been much more common than reported mainly from the Eastern Anatolia region of Turkey. Since in vitro serologic diagnosis tests with high specificity for AE have not been used in our country, most of the cases with liver lesions were misdiagnosed by radiological investigations as malignancies. The aim of this study was to evaluate the diagnostic value of the in-house ELISA methods developed by using three different antigens (EgHF, Em2, EmII/3-10) in the serological diagnosis of AE. The study samples included a total of 100 sera provided by Bern University Parasitology Institute where samples were obtained from patients with helminthiasis and all were confirmed by clinical, parasitological and/or histopathological means. Ten samples from each of the cases infected by E.multilocularis, E.granulosus, Taenia solium, Wuchereria bancrofti, Strongyloides stercolaris, Ascaris lumbricoides, Toxocara canis, Trichinella spiralis, Fasciola hepatica and Schistosoma haematobium were studied. In the study, EgHF (E.granulosus hydatid fluid) antigens were prepared in our laboratory from the liver cyst fluids of sheeps with cystic echinococcosis, however Em2 (E.multilocularis metacestode-purified laminated layer) and EmII/3-10 (E.multilocularis recombinant protoscolex tegument) antigens were provided by Bern University Parasitology Institute. Flat bottom ELISA plates were covered with EgHF, Em2 and EmII/3-10 antigens in the concentrations of 2.5 µg, 1 µg and 0.18 µg per well, respectively, and all sera were tested by EgHF-ELISA, Em2-ELISA and EmII/3-10-ELISA methods. For each tests, the samples which were reactive above the cut-off value (mean OD of negative controls+2 SD) were accepted as positive. The sensitivity of the ELISA tests performed with EgHF, Em2 and Em2II/3-10 antigens were estimated as 100%, 90% and 90%, respectively, whereas the specificity were 63%, 91% and 91%, respectively. When Em2-ELISA and EmII/3-10-ELISA tests were evaluated together, the specificity increased to 96%. Our data indicated that the highest sensitivity (100% with EgHF-ELISA) and specificity (96% with Em2-ELISA + EmII/3-10-ELISA) for the serodiagnosis of AE can be achieved by the combined use of the ELISA tests with three different antigens. It was concluded that the early and accurate diagnosis of AE in our country which is endemic for that disease, could be supported by the use of highly specific serological tests such as Em2-ELISA ve EmII/3-10-ELISA contributing radiological data.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Chagas` disease caused by Trypanosoma cruzi is endemic in Latin America. T. cruzi presents heterogeneous populations and comprises two main genetic lineages, named T. cruzi I and T. cruzi II. Diagnosis in the chronic phase is based on conventional serological tests, including indirect immunofluorescence (IIF) and enzyme-linked immunosorbent assay (ELISA), and diagnosis in the acute phase based on parasitological methods, including hemoculture. The objective of this study was to evaluate the diagnostic procedures of Chagas` disease in adult patients in the chronic phase by using a PCR assay and conventional serological tests, including TESA-blot as the gold standard. Samples were obtained from 240 clinical chronic chagasic patients. The sensitivities, compared to that of TESA-blot, were 70% for PCR using the kinetoplast region, 75% for PCR using the nuclear repetitive region, 99% for IIF, and 95% for ELISA. According to the serological tests results, we recommend that researchers assess the reliability and sensitivity of the commercial kit Chagatest ELISA recombinant, version 3.0 (Chagatest Rec v3.0; Wiener Lab, Rosario, Argentina), due to the lack of sensitivity. Based on our analysis, we concluded that PCR cannot be validated as a conventional diagnostic technique for Chagas` disease. These data have been corroborated by low levels of concordance with serology test results. It is recommended that PCR be used only for alternative diagnostic support. Using the nuclear repetitive region of T. cruzi, PCR could also be applicable for monitoring patients receiving etiologic treatment.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Sera from the patients (N = 10) with schistosomiasis mansoni of the hospital of Federal University of Pernambuco, the Schistosoma mansoni egg-positive (N = 51) and -negative (N = 452) inhabitants in Cabo City area, out-patients (N = 37) of the IMIP hospital and Japanese immigrants (N = 127) in Petrolina City area of northeast Brazil as well as Japanese healthy subjects (N = 30) were examined by serological tests including an enzyme-linked immunosorbent assay with antigens prepared from eggs (ELISA-egg) and adult worms (ELISA-adult). The ELISA with egg or adult antigen correctly identified 100% of the uninfected individuals lived in non-endemic area of schistosomiasis. Moreover, when examined cross-reactivity of our ELISA with sera isolated from 78 subjects infected with various intestinal parasitic infections, only one of these sera reacted with the egg and adult antigens. On the examination of 51 sera from the egg-positive subjects, the ELISA-egg revealed the highest sensitivity (98.0%), whereas a large number of false negative reactions of ELISA-adult, Ouchterlony method using adult antigen, circumoval precipitation and immediate intradermal skin test were observed. A low sensitivity of these serologic tests except for ELISA-egg appears to be primarily due to their inability to detect antibody in the sera from egg-positive infantiles. There was no positive correlation between the absorbance values of these two types of ELISA among the sera isolated from ELISA-positive subjects. Rather, by the reactivity of these sera to egg or adult antigen, they could be divided into two subgroups; one reacted more positively with egg antigen and the other with adult antigen. Moreover, it was confirmed that the sera from young subjects (under 20 years old) appear to be highly reactive to the egg antigen than did aged ones. These data suggest that the ELISA with egg antigen, but not with the adult antigen, appears to be useful for the serological survey of schistosomiasis mansoni in the endemic area of northeast Brazil.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Twenty-seven mycologically proven cases of paracoccidioidomycosis (PCM) were treated with itraconazole (100-200 mg/day in month 1 and 100 mg/day until month 6-8) and evaluated clinically and serologically, up to 3.5 years post-therapy, using Dot-blot and ELISA for measuring the titers of IgG, IgA and IgM anti-P. brasiliensis antibodies and Western-blot for determining IgG, IgA and IgM antibodies against the antigen components of the fungus. Before treatment, 81.5% (Dot-blot) and 84% (ELISA) of the patients presented elevated IgG anti-P. brasiliensis antibody titers which dropped slightly with treatment. On the other hand, the percentages of pre-treatment high-titered sera for IgA and IgM anti-P.brasiliensis were lower (5l.9% and 5l.8%: Dot-blot; 16.5 and 36%: ELISA, respectively) but the titers tended to become negative more frequently with treatment. Prior to treatment, the percentages of positivity for IgG, IgA and IgM anti-P.brasiliensis antibodies in Western-blot were 96%, 20.8% and 41.6%, respectively. Antigens with molecular weights varying from 16-78 kDa, from 21-76 kDa and from 27-78 kDa were reactive for IgG, IgA and IgM antibodies, respectively. The most frequently reactive antigenic components had molecular weights of 27, 33 and 43 kDa for IgG, and 70 for IgA and IgM antibodies. During the period of study, the patients responded well to treatment. The present data confirm the diversity and complexity of the humoral response in PCM, and the importance of utilizing different serological tests to detect IgG, IgA and IgM anti-P. brasiliensis antibodies

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The liver abscess is the most frequent extraintestinal complication of intestinal amoebiasis: its diagnosis is suggested by the clinical picture but it must be confirmed by paraclinic tests. Themost stringent diagnosis requires identification of E. histolytica. But this is possible only in a few cases. Serological tests greatly improve the diagnosis of this severe complication of amoebiasis. We compared the Enzyme Linfed Immunosorbent Assay and the Counterimmunoeletrophoresis techniques. Both techniques were used to detect amoebic antibodies in 50 control patients, 30 patients with liver abscess and 30 patients with intestinal amoebiasis. All the sera from control patients gave negative results iin both techniques. When analysing the sera from patients with intestinal amoebiasis, 10% of them were positive by ELISA but non by CIE. The sera of patients with liver abscess, we found that 90% were positive by the ELISA method and 66.6% by the CIE technique. In patients with amoebic liver abscess, the results showed that the ELISA was more sensitive than the CIE, as it presented a higher sensitivity (100%) than that of the CIE technique (66%).

Relevância:

70.00% 70.00%

Publicador:

Resumo:

INTRODUCTION: The present study was designed to assess the occurrence of co-infection or cross-reaction in the serological techniques used for detecting the anti-Leishmania spp., -Babesia canis vogeli and -Ehrlichia canis antibodies in urban dogs from an area endemic to these parasites. METHODS: The serum samples from dogs were tested for the Babesia canis vogeli strain Belo Horizonte antigen and Ehrlichia canis strain São Paulo by immunofluorescence antibody test (IFAT) and by anti-Leishmania immunoglobulin G (IgG) antibody detection to assess Leishmania infection. We used the following four commercial kits for canine visceral leishmaniasis: ELISA, IFAT, Dual Path Platform (DPP) (Bio Manguinhos(r)/FIOCRUZ/MS) and a rK39 RDT (Kalazar Detect Canine Rapid Test; Inbios). RESULTS : Of 96 serum samples submitted to serological assays, 4 (4.2%) were positive for Leishmania as determined by ELISA; 12 (12.5%), by IFAT; 14 (14.6%) by rK39 RDT; and 20 (20.8%), by DPP. Antibodies against Ehrlichia and Babesia were detected in 23/96 (23.9%) and 30/96 (31.2%) samples, respectively. No significant association was identified between the results of tests for detecting Babesia or Ehrlichia and those for detecting Leishmania (p-value>0.05). CONCLUSIONS: In the present study, we demonstrated co-infection with Ehrlichia or Babesia and Leishmania in dogs from Minas Gerais (Brazil); we also found that the serological tests that were used did not cross-react.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A direct agglutination test (DAT) and an immunofluorescence technique (IFAT) were compared for detection of Leishmania infantum infection in 43 dogs and five foxes from Alto-Douro and Arrábida, two known endemic areas in Portugal. In four dogs with proved canine leishmaniasis, both DAT and IFAT showed positive readings (titres >1:320 and >1:128). Of 34 samples collected from apparently healthy dogs, ten were positive by both serological tests and eight were serologically positive by one test or the other. Three foxes out of five captured in this area, scored titres indicative of leishmaniasis in both DAT and IFAT. The concordance between DAT and IFAT in all collected samples (48) was 81.25%. Considering these and previous studies in the adjacent Mediterranean areas, the seroprevalence of L. infantum infection in the canine and vulpine populations appear to be of high magnitude.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Paracoccidioidomycosis should be differentiated from other opportunistic diseases in human immunodeficiency virus (HIV)/acquired immunodeficiency syndrome (AIDS) patients who live in Latin America. Laboratory investigation can begin with serological tests, which are rapid and efficient. In the present study, double immunodiffusion (DID), counterimmunoelectrophoresis (CIEP) and an enzyme linked immunosorbent assay (ELISA) tests were assessed for the detection of anti-Paracoccidioides brasiliensis antibodies in 40 patients coinfected with HIV. The results were compared to those obtained for 75 non-HIV-infected patients with endemic paracoccidioidomycosis. Anti-P. brasiliensis antibodies were detected in 65% (DID), 79% (CIEP) and 95% (ELISA) of the patients with HIV/AIDS, significantly lower rates than those detected in cases of endemic paracoccidioidomycosis, which were 89%, 99% and 100%, respectively. The reactive sera of HIV-infected patients also showed lower anti-P. brasiliensis antibody titres than those of non-HIV-infected patients. Despite the lower intensity of the specific humoral response, serological tests are useful for the diagnosis of opportunistic paracoccidioidomycosis in the HIV/AIDS population. We suggest optimization of the laboratory diagnosis by combining the ELISA test with CIEP or DID.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In Brazil, human and canine visceral leishmaniasis (CVL) caused byLeishmania infantum has undergone urbanisation since 1980, constituting a public health problem, and serological tests are tools of choice for identifying infected dogs. Until recently, the Brazilian zoonoses control program recommended enzyme-linked immunosorbent assays (ELISA) and indirect immunofluorescence assays (IFA) as the screening and confirmatory methods, respectively, for the detection of canine infection. The purpose of this study was to estimate the accuracy of ELISA and IFA in parallel or serial combinations. The reference standard comprised the results of direct visualisation of parasites in histological sections, immunohistochemical test, or isolation of the parasite in culture. Samples from 98 cases and 1,327 noncases were included. Individually, both tests presented sensitivity of 91.8% and 90.8%, and specificity of 83.4 and 53.4%, for the ELISA and IFA, respectively. When tests were used in parallel combination, sensitivity attained 99.2%, while specificity dropped to 44.8%. When used in serial combination (ELISA followed by IFA), decreased sensitivity (83.3%) and increased specificity (92.5%) were observed. Serial testing approach improved specificity with moderate loss in sensitivity. This strategy could partially fulfill the needs of public health and dog owners for a more accurate diagnosis of CVL.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

To find the most reliable screening method for Trypanosoma cruzi infection in blood banks. Epidemiological data, lymphoproliferation assay, parasitological, conventional serological tests: immunofluorescence, haemagglutination, ELISA with epimastigote and trypomastigote antigens and reference serological tests: trypomastigote excreted-secreted antigens (TESA) blot and chemiluminescent ELISA assay with mucine from trypomastigote forms were applied to individuals with inconclusive serology, non-chagasic individuals and chronic chagasic patients. TESA blot had the best performance when used as a single test in all the groups. In the inconclusive group 20.5% of individuals were positive for TESA blot, 23.3% for either lymphoproliferation or TESA blot, and 17.8% for lymphoproliferation only. Positive lymphoproliferation without detectable antibodies was observed in 5.47% of all inconclusive serology cases. Analysis of six parameters (three serological assays, at least one parasitological test, one lymphoproliferation assay and epidemiological data) in the inconclusive group showed that diagnosis of Chagas` disease was probable in 15 patients who were positive by two or more serological tests or for whom three of those six parameters were positive. TESA blot is a good confirmatory test for Chagas` disease in the inconclusive group. Although lymphoproliferation suggests the diagnosis of Chagas` disease in the absence of antibodies when associated with a high epidemiological risk of acquiring Chagas` disease, the data from this study and the characteristics of the lymphoproliferation assay (which is both laborious and time-consuming) do not support its use as a confirmatory test in blood-bank screening. However, our findings underscore the need to develop alternative methods that are not based on antibody detection to improve the diagnosis when serological tests are inconclusive.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Neosporosis and toxoplasmosis are two important infections in young and adult sheep, leading to low production and abortion. This study aimed to determine the frequency of antibodies to Toxoplasma gondii and Neospora caninum in sheep from the eastern region of São Paulo State, Brazil. Serum samples (382) were collected from the sheep and assayed for T. gondii through modified agglutination test (MAT) and indirect fluorescent antibody test (IFAT), and for N. caninum antibodies, through IFAT, with cut-off titers equal to 16 (T. gondii) and 25 (N. caninum). All frozen samples were sent to the Center for Zoonoses Research (NUPEZO), Department of Veterinary Hygiene and Public Health (DHSVP), FMVZ, UNESP, for serological tests. A total of 71/382(18.6%) samples reacted to T. gondii, especially at titers 16 (28; 39.4%), 64(15; 21.1%), 256 (21; 29.6%) and 1024 (6; 8.5%) by MAT, and 16(34: 47.9%), 64 (18; 25.4%), 256 (14; 19.7%) and 1024 (5; 7%) by IFAT. As regards N. caninum, 49/382 (12.8%) samples reacted at titers 25 (17; 34.7%), 50 (11; 22.5%), 100 (11; 22.5%), and >= 200 (10; 20.4%). These animals presented infection but no clinical signs. Six and ten animals had high titers for toxoplasmosis and neosporosis. No significant association was observed between antibodies for both parasites (P = 0.535) according to Fisher's exact test, and no correlation was found between T. gondii (MAT) and N. caninum antibody titers (r = -0.0068; P=0.895), T. gondii (IFAT) and N. caninum antibody titers (r = -0.0025; P = 0.961). Thus, T. gondii and N. caninum infections were observed in farms located in São Paulo State, where sheep play an important economical role for the national and regional business. (C) 2010 Elsevier By. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Abstract Background Serological tests to detect antibodies specific to Plasmodium vivax could be a valuable tool for epidemiological studies, for screening blood donors in areas where the malaria is not endemic and for diagnosis of infected individuals. Because P. vivax cannot be easily obtained in vitro, ELISA assays using total or semi-purified antigens are rarely used. Based on this limitation, we tested whether recombinant proteins representing the 19 kDa C-terminal region of the merozoite surface protein-1 of P. vivax (MSP119) could be useful for serological detection of malaria infection. Methods Three purified recombinant proteins produced in Escherichia coli (GST-MSP119, His6-MSP119 and His6-MSP119-PADRE) and one in Pichia pastoris (yMSP119-PADRE) were compared for their ability to bind to IgG antibodies of individuals with patent P. vivax infection. The method was tested with 200 serum samples collected from individuals living in the north of Brazil in areas endemic for malaria, 53 serum samples from individuals exposed to Plasmodium falciparum infection and 177 serum samples from individuals never exposed to malaria. Results Overall, the sensitivity of the ELISA assessed with sera from naturally infected individuals was 95%. The proportion of serum samples that reacted with recombinant proteins GST-MSP119, His6-MSP119, His6-MSP119-PADRE and yMSP119-PADRE was 90%, 93.5%, 93.5% and 93.5%, respectively. The specificity values of the ELISA determined with sera from healthy individuals and from individuals with other infectious diseases were 98.3% (GST-MSP119), 97.7% (His6-MSP119 and His6-MSP119-PADRE) or 100% (yMSP119-PADRE). Conclusions Our study demonstrated that for the Brazilian population, an ELISA using a recombinant protein of the MSP119 can be used as the basis for the development of a valuable serological assay for the detection of P. vivax malaria.