946 resultados para Septic tanks.
Resumo:
Peru is a developing country with abundant fresh water resources, yet the lack of infrastructure leaves much of the population without access to safe water for domestic uses. The author of this report was a Peace Corps Volunteer in the sector of water & sanitation in the district of Independencia, Ica, Peru. Independencia is located in the arid coastal region of the country, receiving on average 15 mm of rain annually. The water source for this district comes from the Pisco River, originating in the Andean highlands and outflowing into the Pacific Ocean near the town of Pisco, Peru. The objectives of this report are to assess the water supply and sanitation practices, model the existing water distribution system, and make recommendations for future expansion of the distribution system in the district of Independencia, Peru. The assessment of water supply will be based on the results from community surveys done in the district of Independencia, water quality testing done by a detachment of the U.S. Navy, as well as on the results of a hydraulic model built in EPANET 2.0 to represent the distribution system. Sanitation practice assessments will be based on the surveys as well as observations from the author while living in Peru. Recommendations for system expansions will be made based on results from the EPANET model and the municipality’s technical report for the existing distribution system. Household water use and sanitation surveys were conducted with 84 families in the district revealing that upwards of 85% store their domestic water in regularly washed containers with lids. Over 80% of those surveyed are drinking water that is treated, mostly boiled. Of those surveyed, over 95% reported washing their hands and over 60% mentioned at least one critical time for hand washing when asked for specific instances. From the surveys, it was also discovered that over 80% of houses are properly disposing of excrement, in either latrines or septic tanks. There were 43 families interviewed with children five years of age or under, and just over 18% reported the child had a case of diarrhea within the last month at the time of the interview. Finally, from the surveys it was calculated that the average water use per person per day is about 22 liters. Water quality testing carried out by a detachment of the U.S. Navy revealed that the water intended for consumption in the houses surveyed was not suitable for consumption, with a median E. coli most probable number of 47/100 ml for the 61 houses sampled. The median total coliforms was 3,000 colony forming units per 100 ml. EPANET was used to simulate the water delivery system and evaluate its performance. EPANET is designed for continuous water delivery systems, assuming all pipes are always flowing full. To account for the intermittent nature of the system, multiple EPANET network models were created to simulate how water is routed to the different parts of the system throughout the day. The models were created from interviews with the water technicians and a map of the system created using handheld GPS units. The purpose is to analyze the performance of the water system that services approximately 13,276 people in the district of Independencia, Peru, as well as provide recommendations for future growth and improvement of the service level. Performance evaluation of the existing system is based on meeting 25 liters per person per day while maintaining positive pressure at all nodes in the network. The future performance is based on meeting a minimum pressure of 20 psi in the main line, as proposed by Chase (2000). The EPANET model results yield an average nodal pressure for all communities of 71 psi, with a range from 1.3 – 160 psi. Thus, if the current water delivery schedule obtained from the local municipality is followed, all communities should have sufficient pressure to deliver 25 l/p/d, with the exception of Los Rosales, which can only supply 3.25 l/p/d. However, if the line to Los Rosales were increased from one to four inches, the system could supply this community with 25 l/p/d. The district of Independencia could greatly benefit from increasing the service level to 24-hour water delivery and a minimum of 50 l/p/d, so that communities without reliable access due to insufficient pressure would become equal beneficiaries of this invaluable resource. To evaluate the feasibility of this, EPANET was used to model the system with a range of population growth rates, system lifetimes, and demands. In order to meet a minimum pressure of 20 psi in the main line, the 6-inch diameter main line must be increased and approximately two miles of trench must be excavated up to 30 feet deep. The sections of the main line that must be excavated are mile 0-1 and 1.5-2.5, and the first 3.4 miles of the main line must be increased from 6 to 16 inches, contracting to 10 inches for the remaining 5.8 miles. Doing this would allow 24-hour water delivery and provide 50 l/p/d for a range of population growth rates and system lifetimes. It is expected that improving the water delivery service would reduce the morbidity and mortality from diarrheal diseases by decreasing the recontamination of the water due to transport and household storage, as well as by maintaining continuous pressure in the system to prevent infiltration of contaminated groundwater. However, this expansion must be carefully planned so as not to affect aquatic ecosystems or other districts utilizing water from the Pisco River. It is recommended that stream gaging of the Pisco River and precipitation monitoring of the surrounding watershed is initiated in order to begin a hydrological study that would be integrated into the district’s water resource planning. It is also recommended that the district begin routine water quality testing, with the results available to the public.
Resumo:
"EPA-625/6-84-009."
Resumo:
Mode of access: Internet.
Resumo:
Rwanda is a landlocked country located in Africa's Central-East Great Lakes region. It has a population of 7.5 million which occupies 26,338 km'. Its population density (285/km') is one of the highest in the world and has prompted fear of a rapid degradation of the ecosystem. There are no central sewer systems in Rwanda. The use of pit latrines and septic tanks is common in urban and rural areas. People still defecate in the fields (World Bank, 1989). Less than half of the urban population is served by a central water supply. The majority of people get their water untreated from rivers that have been polluted by chemicals and human excreta. In and around the capital city of Kigali, there is a concentration of people, farms, and industries which discharge wastewater into the Nyabarongo River and its tributaries. The Nyabarongo River, a tributary of the Nile, empties into the Akagera River which flows into Lake Victoria. Nyabarongo River water is used for drinking water, cooking, bathing, and agriculture in the Kigali area. There has been very little monitoring of the water quality of the Nyabarongo River and of industrial outfalls located on tributaries of the Nyabarongo River. As a first step in understanding the water quality of the Nyabarongo River, wastewater samples were collected in 1993 from industrial outfalls located on tributaries of the Nyabarongo River. Most of the facilities sampled had no wastewater treatment. The impact of these discharges on the water quality of the Nyabarongo River was evaluated.
Resumo:
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Agronomia e Medicina Veterinária, Programa de Pós-Graduação em Agronomia, 2016.
Resumo:
Quantitative Microbial Risk Assessment (QMRA) analysis was used to quantify the risk of infection associated with the exposure to pathogens from potable and non-potable uses of roof-harvested rainwater in South East Queensland (SEQ). A total of 84 rainwater samples were analysed for the presence of faecal indicators (using culture based methods) and zoonotic bacterial and protozoan pathogens using binary and quantitative PCR (qPCR). The concentrations of Salmonella invA, and Giardia lamblia β-giradin genes ranged from 65-380 genomic units/1000 mL and 9-57 genomic units/1000 mL of water, respectively. After converting gene copies to cell/cyst number, the risk of infection from G. lamblia and Salmonella spp. associated with the use of rainwater for bi-weekly garden hosing was calculated to be below the threshold value of 1 extra infection per 10,000 persons per year. However, the estimated risk of infection from drinking the rainwater daily was 44-250 (for G. lamblia) and 85-520 (for Salmonella spp.) infections per 10,000 persons per year. Since this health risk seems higher than that expected from the reported incidences of gastroenteritis, the assumptions used to estimate these infection risks are critically discussed. Nevertheless, it would seem prudent to disinfect rainwater for potable use.
Resumo:
Analysis of the septic work-up of 194 neonates at Women's College Hospital, Toronto, showed that the only antepartum condition predicting neonatal sepsis was the mother being on antibiotics. The only postnatal condition predicting sepsis was a maternal postpartum white blood cell count over 11,000. The average cost for tests for a septic work-up in these 194 mother-neonate pairs was $71.48 (Canadian dollars), and the average cost of tests to find a septic case was $1,066.77.
Resumo:
Introduction The admission to the Intensive Care Unit with a diagnosis of sepsis and/or septic shock is not uncommon. The aim of this article is to present a nursing case review of a patient admitted to the intensive care unit with a diagnosis of septic shock and the use of bedside acid–base formulae to inform clinical decision making. Method We chose to use a case review. This method is useful in reporting unusual or rare cases and is typically seen more in medicine than in nursing. Discussion The gentleman in question was a self-presentation with a short history of fever and worsening shortness of breath. His condition worsened where he required admission to the intensive care unit. The use of ‘advanced’ acid–base interpretation to guide his nursing care provided a platform from which to advance a deeper understanding of the intricacies the critically ill patient often presents. Conclusion The use of case review is enlightening in understanding the disease process and the decision-making that accompanies this. The lessons learnt are applicable to a wider nursing audience because understanding acid–base physiology is beneficial in supporting and advancing critical care nursing practice.
Resumo:
This paper presents two novel nonlinear models of u-shaped anti-roll tanks for ships, and their linearizations. In addition, a third simplified nonlinear model is presented. The models are derived using Lagrangian mechanics. This formulation not only simplifies the modeling process, but also allows one to obtain models that satisfy energy-related physical properties. The proposed nonlinear models and their linearizations are validated using model-scale experimental data. Unlike other models in the literature, the nonlinear models in this paper are valid for large roll amplitudes. Even at moderate roll angles, the nonlinear models have three orders of magnitude lower mean square error relative to experimental data than the linear models.
Resumo:
Parametric ship roll resonance is a phenomenon where a ship can rapidly develop high roll motion while sailing in longitudinal waves. This effect can be described mathematically by periodic changes of the parameters of the equations of motion, which lead to a bifurcation. In this paper, the control design of an active u-tank stabilizer is carried out using Lyapunov theory. A nonlinear backstepping controller is developed to provide global exponential stability of roll. An extension of commonly used u-tank models is presented to account for large roll angles, and the control design is tested via simulation on a high-fidelity model of a vessel under parametric roll resonance.
Resumo:
Critical illness, acute renal failure and continuous renal replacement therapy (CRRT) are associated with changes in pharmacokinetics. Initial antibiotic dose should be based on published volume of distribution and generally be at least the standard dose, as volume of distribution is usually unchanged or increased. Subsequent doses should be based on total clearance. Total clearance varies with the CRRT clearance which mainly depends on effluent flow rate, sieving coefficient/saturation coefficient. As antibiotic clearance by healthy kidneys is usually higher than clearance by CRRT, except for colistin, subsequent doses should generally be lower than given to patients without renal dysfunction. In the future therapeutic drug monitoring, together with sophisticated pharmacokinetic models taking into account the pharmacokinetic variability, may enable more appropriate individualized dosing.
Resumo:
Surface aeration systems employed in activated sludge plants are the most energy-intensive units of the plants and typically account for a higher percentage of the treatment facility's total energy use. The geometry of the aeration tank imparts a major effect on the system efficiency. It is said that at optimal geometric onditions, systems exhibits the maximum efficiency. Thus the quantification of the optimal geometric conditions in surface aeration tanks is needed. Optimal geometric conditions are also needed to scale up the laboratory result to the field installation. In the present work, experimental studies have been carried out on baffled and unbaffled circular surface aeration tanks to ascertain the optimal geometric conditions. It is found that no optimal geometric conditions exist for the liquid/water depth in circular surface aeration tanks; however, for design purposes, a standard value has been assumed. Based on the optimal geometric conditions, a scale-up equation has been developed for the baffled circular surface aeration tanks.
Resumo:
Captive-reared broodstock of the black tiger prawn (Penaeus monodon) have exhibited poor reproductive performance limiting attempts to domesticate this species. The potential for improved reproductive performance was assessed by determining heritabilities of four measures of reproductive performance, their genetic correlations with each other and with growth rate and weight at age. Heritability estimates (h2 ± S.E.) obtained from √ (days to spawn), √ (egg number), √ (nauplii number) and arcsin √ (proportion hatched) were 0.47 ± 0.15, 0.41 ± 0.18, 0.27 ± 0.16, and 0.18 ± 0.16, respectively. Estimates of genetic correlations between reproductive traits and weight at age, or growth rate were less than 0.5 except for √ (egg number) and weight at 54 weeks (0.93 ± 0.19) and √ (egg number) and 16-54-week growth (0.63 ± 0.29).
Resumo:
To experimentally investigate the effect of vertical artificial substrate and different densities of the banana prawn Penaeus (Fenneropenaeus) merguiensis on nutrient levels in prawn pond effluent, a time series experiment was conducted in a replicated tank system supplied periodically with discharge from a prawn production pond. Few differences (P>0.05) were detected between tanks without prawns, and tanks with low densities (5 prawns in 1700 litres) of prawns (10-12 g), in terms of nitrogen and phosphorus in the water column over the 28-day experimental period. Higher densities of prawns (starting at 25 or 50 per tank) caused an elevation of these macronutrients in the water column. This was partly due to prawn biomass losses from mortalities and weight reductions in the tank system. The survival and condition of prawns was significantly (P<0.05) reduced in tanks at these higher densities. The presence of artificial substrate (2 m2 tank-1) did not affect (P>0.05) the levels of nutrients in tank water columns, but significantly (P<0.05) increased the amount of nitrogen in tank residues left at the end of the trial when no prawns were present. The prawns had obviously been grazing on surfaces inside the tanks, and their swimming actions appeared to keep light particulate matter in suspension. Higher prawn densities increased microalgal blooms, which presumably kept ammonia levels low, and it is suggested that this association may provide the means for improved remediation of prawn farm effluent in the future.