954 resultados para Septic Tank


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper reports the results of a 2-year study of water quality in the River Enborne, a rural river in lowland England. Concentrations of nitrogen and phosphorus species and other chemical determinands were monitored both at high-frequency (hourly), using automated in situ instrumentation, and by manual weekly sampling and laboratory analysis. The catchment land use is largely agricultural, with a population density of 123 persons km−2. The river water is largely derived from calcareous groundwater, and there are high nitrogen and phosphorus concentrations. Agricultural fertiliser is the dominant source of annual loads of both nitrogen and phosphorus. However, the data show that sewage effluent discharges have a disproportionate effect on the river nitrogen and phosphorus dynamics. At least 38% of the catchment population use septic tank systems, but the effects are hard to quantify as only 6% are officially registered, and the characteristics of the others are unknown. Only 4% of the phosphorus input and 9% of the nitrogen input is exported from the catchment by the river, highlighting the importance of catchment process understanding in predicting nutrient concentrations. High-frequency monitoring will be a key to developing this vital process understanding.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In Natal still dominates the use of individual disposal systems for domestic sewage, once only 29% of the city has a sewarage system. Wastes that are accumulated in these individual treatment systems should be exhausted periodically, service provided by collector entrepreneurs. Some of these companies causing major damage to the environment. In Natal, only two companies have their own septage (RESTI) treatment system, which were designed with parameters from domestic sewage generating strain and inefficient systems. Therefore, the characterization becomes essential as a source of parameters for their design. Thus, this work presents the physical-chemical and microbiological characterization of waste pumped from individual sewage treatment systems. Samples collections were made weekly from 5 different trucks at the reception point on the treatment plant on the point of the preliminary treatment. From each truck it was taken 5 samples during the discharge in order to make a composite sample. Afterwards, samples were carried out to laboratory and analyses for determination of temperature, pH, conductivity, BOD, COD, nitrogen (ammonia e organic), alkalinity, oils, phosphorus, solids, faecal coliforms and helminth egg. The results were treated as a single database, and ranked according to its generating source (multi and single house, lodging, health, services and / or food), area of origin (metropolitan, south and north) and type of system (cesspits, septic tank and / or sink). Through these data it was possible to verify that the type of system adopted by most in Natal and the metropolitan region is cesspit, besides to confirm the difference between the septage of areas with a population have different social and economical characteristics. It was found that the septage have higher concentrations than domestic sewage, except for thermotolerant coliforms that showed concentrations of 1,38E+07. Among the parameters studied, is the median values identified for COD (3,549 mg / L), BOD (973mg / L) and total solids (3.557mg / L). The volatile fraction constitutes about 70% of the total solids of the septage. For helminths has been a median of 7 eggs/L. In general, the characteristics of the waste followed the variability found in the literature reviewed for all variables, showing high amplitudes

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Because of disability in public policy development in mind to attend issues of sanitation in the municipalities, companies known as "clean-blue" appeared proposing to solve a simple collection and management of wastewater produced in single or multifamily residences, commercial, hospitals, etc. In the case of an activity in which there are no worries about the fate of sewage, emerged some doubts about the degree of health and environmental safety in these companies. Traditionally, most of them makes the provision of waste depleted soil or wetland, open, usually located on the outskirts of cities (MENESES, 2001). In turn, the sludge from septic tanks exhausted, provided no technical criteria - in the soil, rivers and as an agricultural fertilizer put in risk the health of the population and environmental quality. This work was entered in the search network 5 of the Notice of the Research Program in Sanitation - PROSAB-5, aimed to study the theme 'Characterization and study of alternative ways of treating sludge from septic tanks in the city of Natal, RN', proposing to evaluate the performance of the use of stabilization ponds as a system to handle waste from septic tanks exhausted. A series of lakes studied belong to one of the largest clean-pit of Natal, consisting of two anaerobic ponds, one facultative and maturation, and a tank disinfection, the wastewater being released in the Potengi River. Samples were collected between the months of October 2007 to October 2008, at six points previously defined and judged as more appropriate to what is proposed study. The analysis results in field and laboratory showed the most significant removal of COD (88.93%), total suspended solids (94.87%), organic nitrogen (66.87%) and thermotolerant coliforms (99.88%). Some results have not reached the expected because the system under study had operating problems that have undermined the efficiency of the reactors

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Only 32% of the population of Natal is attended by sewage, while the remaining population use pits and septic tanks. The characterization of the contents of septic tanks and pits contributes to the performance of such system and may guide the decision on treatment of these contents. The main of this research is to characterize the contents of interior residential pits and septic tanks in the greater Natal, with the following specific goals: to develop and manufacture a sampler capable of collecting a representative sample of the entire column (the surface scum, the clarified liquid and sludge bottom); to compare the contents of the tanks with the pits; to compare the contents of the septage from vacuum trucks; to relate the composition content with socioeconomic characteristics of households; to compare the content in both chambers of the septic tanks in series; to assess the situation of the content before and six months after the cleanness; and ultimately propose a pilot scale plant for treatment of septage. Once the sampler was developed, samples were collected within 14 septic tanks and 10 pits in many districts of Natal. Medians of the 24 systems were obtained: temperature, pH, conductivity, oil and grease, total solids, total suspended solids and sediments of 28.0 °C, 6.95; 882 mS/cm, 75.2 mg/L; 10,169 mg/L, 6,509 mg/L and 175 mL/L respectively; 111.0 mgN/L for ammonia, 130.5 mgN/ L for organic nitrogen, 0.2 mgN/L for nitrite, 0.4 mg/L for nitrate; 8935 mgO2/L for COD, 29.2 mgP/L for total phosphorus, thermotolerant coliforms from 9.95 E +06 CFU/100mL helminth eggs and 9.2 eggs/L with a maximum concentration of 688 eggs/L and minimum of 0 eggs/L. Medians of organic nitrogen and TKN were significantly different between groups of tanks and pits. The systems with cleanness gap from 11 and 20 years presented the higher concentrations for most variables. The effluent from the toilets and bathrooms participate more effectively in contributing fractions of solids, alkalinity, nitrogen, COD, total phosphorus, thermotolerant coliforms and helminth eggs. The systems used by socioeconomics class with income from R$ 3,700.00 to R$ 7,600.00, presented higher concentrations for COD, nitrogen, solids and helminth eggs. The first of the two chambers had always presented higher concentrations over the second compartment. The analysis of variance for most variables, showed that the values of septic tanks, pits and septage from vacuum trucks belong to the same group. In the samples taken after cleanness, the median of pH and temperature increased, while alkalinity, COD, organic nitrogen, total phosphorus, ammonia and helminth eggs decreased. The oils and greases and thermotolerant coliforms had slightly varied due to the continuous release of sewage into the systems that maintained their steady state concentrations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Although the good performance in organic matter and suspended solids removal, the anaerobic reactors are unable to remove ammonia nitrogen from sewage, which makes indispensable to include a step of post-treatment for removal of ammonia or nitrate as necessary. This paper presents the performance of a new variant technology, where the nitrification unit, preceded by anaerobic units, is a submerged aerated biological filter, without continuous sludge discharge in their daily operation. The oxygenation system is very simple and inexpensive, consisting of perforated hoses and compressors. The anaerobic reactors are a septic tank with two chambers followed (8.82 m³) and two parallel anaerobic filters (36 m³ each) filled with ceramic bricks and conics plastic parts. Both followed aerated filters were filled with cut corrugated conduit. The study evaluated the behavior of the system with constant domestic sewage flow (10 m³/d) and different aeration conditions, are these: stage 01, when applied air flow of 0.01 m³ air/min in both aerated filter; stage 02, remained in the initial air flow rate in the second aerated filter and increased at the first to 0.05 m³ air/min; at last, at last, in stage 03, the air flow rate of first aerated filter was 0.10 m³ air/min and on the second remained at 0.01 m³ air/min. The filter FA1 received load of 0.41 kg COD/m³.d, 0.37 kg COD/m³.d and 0.26 kg COD/m³.d on phases 01, 02 and 03, respectively. The FA2 received loads of 0.25 kg COD/m³.d, 0.18 kg COD/m³.d and 0.14 kg COD/m³.d on phases 01, 02 and 03, respectively. During stage 01, were found the following results: 98% removals of BODtotal and 92% of CODtotal, with effluent presenting 9 mg/L of BODtotal final average and 53 mg/L of CODtotal average; suspended solids removals of 93%, with a mean concentration of 10 mg/L in the final effluent; 47% reduction of ammonia of FA2 to FAN 's, presenting average of 28 mg NNH3/ L of ammonia in the effluent with; the dissolved oxygen levels always remained around 2.0 mg/L. During stage 02, were found removals of 97% and 95% to BODtotal and suspended solids, respectively, with average final concentrations of 8 and 7 mg/L, respectively; was removed 60% of ammonia, whose final concentration was 16.3 mg NNH3/ L, and nitrate was increased to a final average concentration of 16.55 mg N-NO3/L. Finally, the stage 03 provided 6 mg/L of DBOtotal (98% removal) and 23 mg/L of CODtotal (95% removal) of final effluent concentrations average. At this stage was identified the higher ammonia oxidation (86%), with final effluent showing average concentration of 6.1 mg N-NH3/L, reaching a minimum of 1.70 mg N-NH3/L. In some moments, during stage 03, there was a moderate denitrification process in the last aerated filter. The average turbidity in the effluent showed around 1.5 NTU, proving the good biomass physical stability. Therefore, the results demonstrate the submerged biological filters potential, filled with high void ratio material (98%), and aerated with hoses and compressor adoption, in the carbonaceous and nitrogenous matter oxidation, also generating an effluent with low concentration of solids

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Stabilization pond is the most used sewage treatment system in the country, corresponding to approximately 90% of all systems. The systems evaluated were stabilization ponds system of sewage treatment in the city of Natal / RN. This research aimed to analyze the possible uses through physical-chemical and bacteriological of these final effluent ponds for urban uses depending on the characteristics after passage around the treatment system. The parameters used were chosen according to those established by Chernicharo et al. (2006), in order to characterize the effluent. The parameters evaluated were: DO, temperature, pH, conductivity, organic nitrogen, ammonia, NTK, total phosphorus, and series of solid fecal coliforms. Generally, the characteristics of the effluent followed variability found in the literature. The results showed an efficiency that is technically feasible to use the effluent end of some of STPs analyzed when checked parameters alone, if fitting in unrestricted urban use, restricted use and urban land use

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In Natal/RN, 68% of the population uses some kind of individual system for their domestic sewers treatment, being that the most used it is septic tank, followed by sumidouro. Every treatment system of sewers, usually used, generates a by-product denominated sludge. That residue presents some components, in its constitution, undesirable under the environmental and sanitary point of view. In such case, to assure that the system treatment has satisfactory results, it is necessary to do the adjusted disposition of the sludge sewage. Several countries are looking for technical alternatives for the use and disposition of residues. Under technical and environmental conditions appropriate, these materials can be used, decreasing the consumption of the natural resources and the treatment need, storage or elimination of the wastes, what decrease the risks created. Some of the alternatives of recycling of the sludge sewage are: the application in the agriculture, in the production of energy and as raw material in the civil construction. This study evaluated asphalt mixtures behavior that partially substituted conventional aggregates by septic tank sludge. The septic tank sludge gave origin to two raw materials called raw sludge and sludge ash. The raw sludge was put as a small aggregate and the sludge ash as filler. In the first experiment it was made a comparison between the mixture with conventional aggregates and the mixtures that replaced sand by raw sludge in the proportions from 5% to 40%. In the second experiment, it was made comparison between mixtures with 1%, 2% and 3% of sludge ash and cement. The stages developed along the study were: physical characterization of the conventional materials; physical, chemistry, thermal, mineralogical characterizations and analysis of environmental risk of the raw sludge; physical characterization and analysis of environmental risk of the sludge ash; analysis of the mixtures performance through its volumetric and mechanical characteristics; forecast of the mixtures susceptibility in the moisture presence. For the grain size composition used and with the percentage asphalt adopted, the mixtures with up to 7,5% of raw sludge in his composition attend to the National Department of Transports Infrastructure (DNIT) specifications. However, in agreement with the mixtures susceptibility in the moisture presence, the mixtures with addition of raw sludge don't present satisfactory acting. In such case, they could be used in arid and semi-arid areas. The raw sludge application in mixtures increased their voids volume and their stability. However, it damaged mixtures adhesiveness. Mixtures with sludge ash and with cement presented similar behavior. However, mixtures with sludge ash presented a better performance than mixtures with cement as for their stability and their tensile strength ratio. The mixture with 1% of sludge ash is better. The wastes studied don't represent environmental risk

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Irrigação e Drenagem) - FCA

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A esquistossomose mansônica é uma das doenças parasitárias mais difundidas no mundo e tem prevalência maior nos países em desenvolvimento, constituindo atualmente um sério problema de saúde pública no Brasil. Em Belém-PA, no Distrito Administrativo de Mosqueiro (DAMOS), há possibilidades de ocorrência de casos autoctones de esquistosomose mansônica, devido a proximidade geográfica com outras áreas onde há registros deste agravo, bem como, pela presença de outros fatores ambientais de risco, como a presença do Biomphalaria straminea. Com a proposta de determinar a prevalência de esquistosomose mansônica no bairro do Maracajá-DAMOS, foi realizado um estudo transversal prospectivo no período entre março de 2011 a janeiro de 2012, através de inquérito coproscópico pelo método quantitativo de Kato-Katz, associado a inquérito sócio-demográfico e ambiental da localidade. Participaram do universo amostral 407 indivíduos incluídos na atenção da Estratégia Saúde da Família, que aceitaram espontaneamente participar da pesquisa, segundo os preceitos éticos vigentes. O perfil sócio-demográfico populacional mostrou predomínio da faixa etária entre 11 e 40 anos, sem diferenças quanto ao gênero, cuja ocupação de dona de casa e estudante, com ensino fundamental incompleto foram as mais citadas. A maioria dos moradores nasceu e procede do DAMOS, residentes no bairro do Maracajá há mais de 20 anos, sem relatos importantes de deslocamentos para outras localidades. A maioria das residências apresentaram serviço de água encanada, com banheiro interno, presença de sanitário com destino das fezes em fossa séptica. As coleções hídricas peridomiciliares se caracterizaram por valas de baixo fluxo e com pequena vazão de água, alta concentração de produtos orgânicos, presença de vegetação macrófitica e do vetor Biomphalaria straminea. Esta população referiu não ter contato com as coleções hídricas e desconhecer o planorbideo vetor, assim como a própria esquistossomose. O inquérito coproscópico resultou em 100% de lâminas negativas quanto a identificação de ovos do S. mansoni, levando a conclusão que embora o bairro do Maracajá ainda seja indene, possui vários fatores para a instalação de um foco de transmissão ativa de esquistossomose, mas ainda existe um frágil equilíbrio ecológico, sustentado pela reduzida exposição dos indivíduos às coleções hídricas, pouco deslocamento da população para áreas com focos estabelecidos da endemia e razoável cobertura de esgotamento sanitário. Este conjunto de variáveis tem funcionado como fatores limitantes ao processo de endemização da esquistossomose no bairro do Maracajá, entretanto deve ser mantido sob vigilância pelas peculiaridades propicias ao fechamento do ciclo do S. mansoni.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Esta pesquisa apresenta o estudo comparativo de reatores anaeróbio de fluxo ascendente e manta de lodo (UASB) e tanque séptico (TS), a fim de investigar a utilização destes reatores em escala unifamiliar no tratamento de esgotos domiciliares. A pesquisa foi realizada em comunidade quilombola próxima a cidade de Belém- PA. Para isto, foram utilizados oito reatores UASB (em forma de “Y”.) e um tanque séptico prismático de câmara única. Os reatores UASB possuíam volume de 0,42 m3, enquanto que o tanque séptico volume de 4,20 m3. Cada reator foi instalado em um domicilio, sendo alimentados exclusivamente por esgoto negro (água, fezes e urina) oriundo dos vasos sanitários dos banheiros. Foi analisada a viabilidade técnica da utilização do primeiro em substituição ao segundo, tendo em vista que o TS é amplamente utilizado em locais do Brasil desprovidos de redes coletoras de esgoto. As operações foram realizadas simultaneamente durante aproximadamente 90 semanas, sendo monitorados parâmetros que possibilitaram a análise da estabilidade operacional e do desempenho de cada reator. Ao final da pesquisa foi observado que os reatores UASB apresentaram desempenho tão satisfatório ou melhor que o do TS no tratamento da matéria orgânica e de sólidos em suspensão. Com isso, ficou evidenciada a viabilidade da aplicação do reator UASB utilizado no tratamento unifamiliar de esgotos de pequenas comunidades rurais.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

When the well "goes dry" or when the windmill or pump breaks down, every one in the household immediately appreciates the value fo plenty of water. In other words, "You never miss the water until the well runs dry." Fortunately, in most sections of this state, plenty of pure water may be obtained by sinking wells of moderate depth, yet surprisingly few farm homes are supplied with running water in the kitchen even though the barn yards are equipped with hydrants and tanks. It is the purpose of this bulletin to present a number of water supply and sewage disposal systems which have been used in Nebraska and surrounding states and which add greatly to the comfort and convenience of the farm home.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A concentração demográfica e de sistemas coletivos de esgotamento sanitário dentro do perímetro urbano da maioria dos municípios brasileiros, dificulta a viabilização do fornecimento de serviços de tratamento de esgotos domésticos à habitações e núcleos habitacionais isolados situados em áreas periurbanas e rurais, intensificando os danos provocados pela poluição de origem antrópica ao meio ambiente e à preservação da saúde pública. Para contribuir no equacionamento deste problema, o presente estudo teve por finalidade avaliar uma wetland construída híbrida em escala real, composta por uma unidade com fluxo contínuo subsuperficial vertical seguida por uma unidade de fluxo contínuo subsuperficial horizontal, cultivadas com capim Vetiver, para o tratamento de efluente proveniente de tanque séptico. A presente configuração experimental busca uma solução de baixo custo e simplificada para o tratamento descentralizado de esgotos domésticos. A estação experimental de tratamento de esgotos, parte integrante e um dos produtos da Rede Nacional de Tratamento de Esgotos Descentralizados RENTED, foi construída no Centro Tecnológico de Hidráulica CTH / Escola Politécnica EPUSP, campus Butantã da USP, em São Paulo. O esgoto bruto foi proveniente do Conjunto Residencial da USP e do restaurante central da Cidade Universitária. As vazões média e máxima de esgoto bruto, respectivamente, de 640L.d-1 e 1600L.d-1, foram aplicadas à entrada do TS de 5.000L e deste escoaram por gravidade à entrada da wetland construída híbrida, com TDH total de 2,8d e 1,1d, respectivamente, sob aplicação das vazões média e máxima de projeto. O monitoramento do experimento em campo, incluindo o período inicial de partida, durou 6 meses consecutivos. Foram avaliados os parâmetros físico-químicos e microbiológicos do esgoto bruto e do efluente do tanque séptico e das câmaras da wetland construída híbrida durante 97 dias consecutivos. Os resultados indicaram que tanto as mudas jovens quanto as adultas de capim Vetiver adaptaram-se bem às condições ambientais. As eficiências médias de remoção no efluente tratado final quanto à matéria orgânica carbonácea foram de 96 por cento para DBO5,20 e 90 por cento para DQO, 40 por cento para N-total, 23 por cento para N-amoniacal total, 60 por cento para P-total, 52 por cento para P-PO4, 74 por cento para SST, 96 por cento para SSV, 75 por cento para sólidos sedimentáveis, 44 por cento para SDV, 88 por cento para sulfeto total, e 97 por cento para óleos e graxas totais, variando entre 73 por cento a 100 por cento . Cerca de 80 por cento da fração orgânica da matéria nitrogenada presente no esgoto bruto foi removida. A remoção de coliformes termotolerantes foi, em média, de 2 e 3 unidades log, e de Escherichia Coli, média de 1 e 3 unidades log, respectivamente, sob aplicação das vazões máxima e média, Giardia sp, média de 99,995 por cento , Cryptosporidium sp, média de 98,7 por cento , Enterovírus, média de 99,6 por cento , e Ascaris sp, média de 0,10 ovo/L. A remoção de sulfetos propiciou a geração de efluente tratado sem odores desagradáveis. A diminuição da vazão aplicada e a elevação do TDH influenciaram positivamente no desempenho do sistema com relação às remoções dos parâmetros físico-químicos e microbiológicos. Com base no presente estudo, ficou evidente o benefício da associação de wetlands construídas com fluxo vertical e horizontal no tratamento de efluente de tanque séptico. O capim Vetiver apresentou bom potencial de utilização em wetlands 8 construídas para tratamento de esgotos domésticos. O sistema experimental de tratamento apresentou flexibilidade operacional, mantendo bom desempenho inclusive nos períodos de sobrecarga. A qualidade do efluente tratado final obtido no presente estudo atende às exigências de lançamento e aos padrões de emissão de efluentes líquidos em corpos dágua e em sistemas públicos de esgotamento sanitário definidos na legislação ambiental federal e do Estado de São Paulo. A tecnologia de wetlands construídas híbridas associada ao tratamento de efluentes de tanque séptico apresentou bom potencial para o tratamento descentralizado de esgotos domésticos, inclusive em regiões com pouca disponibilidade de área livre.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Water remains a predominant vector for human enteric pathogens not just for developing countries but also developed nations, where numerous infectious disease outbreaks, linked to the contamination of drinking water have been documented. Private drinking water wells are a source of drinking water that is largely unstudied even though a significant percentage of the population in Ontario relies on wells as their primary water source. As there exists little to no systematic surveillance for enteric infections or outbreaks related to well water sources, these individuals may be at higher risk of waterborne infectious diseases. The relationships between various fecal indicators in the water of private drinking water wells, including E. coli, Total Coliforms (TC) and Bacteroides, and enteric pathogens, including Campylobacter jejuni, Salmonella spp., and Shiga toxin producing E. coli, were studied. Convenience private well water samples collected from various regions of interest during the summer of 2014 underwent membrane filtration and culture to determine quantities of E. coli and TC colony forming units. 289 E. coli positive and 230 TC-only waters were successfully analyzed by individual qPCR assays for the aforementioned enteric pathogens. Microbial source tracking methods targeted to specific Bacteroides were used to determine the source of fecal contamination as either human or bovine. The source of fecal contamination varied by geographic region and is thought to be due to such things as differences in septic tank density and underlying geology, among others. Fecal indicators, E. coli and Bacteroides, were significantly correlated. E. coli as measured by qPCR was more strongly correlated to both total and human-specific Bacteroides genetic markers than culturable E. coli. Lastly, 1.9% of samples showed molecular evidence of contamination with enteric pathogens. Although low, this finding is significant given the limited volume of water available for testing, and suggests a potential health risk to consumers. Knowing the extent of contamination, as well as the biologic source, can better inform risk assessment and the development of potential intervention strategies for private well water in specific regions of Ontario.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dissertação (mestrado)—Universidade de Brasília, Faculdade de Agronomia e Medicina Veterinária, Programa de Pós-Graduação em Agronomia, 2016.