941 resultados para Sanitary landfill closures
Resumo:
Leachates are effluent produced by decomposition of solid waste, they have complex composition and can be highly toxic. Therefore such percolated liquid should be collected and treated properly to avoid environmental contamination of soil and of water bodies. The objective of this study was to evaluate the toxicity through ecotoxicological tests with Ceriodaphnia dubia (Cladocera - Crustacea) of percolated liquids generated in two different systems of municipal solid waste (MSW) disposal in the city of Natal/ RN: A Sanitary Landfill in the Metropolitan Region of Natal/ RN, and in a dump off area. Furthermore, it was evaluated the possible contamination of the underground water of the dump off area. Two monthly samples were taken at four points between the months of May/2009 and January/2010. The Point "A" corresponds to the end of the pond leachate treatment in ASRMN; The Point "B" corresponds to a containment pond at the dump. The Point "C" is an area near one of the cells of the dump off area where the leachate outcrops; The Point "D" stands for an underground water well at the area. The last point, called "E" was sampled only once and corresponds to the slurry produced by temporary accumulation of solid waste in the open area of the dump. The ecotoxicological tests, acute and chronic, followed the ABNT 13373/2005 rules, with some modifications. The samples were characterized by measuring the pH number, the dissolved oxygen (DO), the salinity, BOD5, COD, Cd, Cu, Pb, Cr, Fe, Mg, Ni, and Zn. At Point A, the average number of EC50-48h ranged between 1.0% and 2.77% (v/v), showing a high toxicity of the leachate to C.dubia in all months. To this point, positive correlations were found between the EC50- 48 with precipitation. Negative correlations were found between the EC50- 48h with salinity. At point B there was no response of the acute exposure of organisms to the test samples. At point C the EC50-48h ranged from 17.68% to 35.36% in just two months of the five ones analyzed, not correlated meaning. Point D, the EC50-48h level ranged between 12.31% and 71.27%, showed a negative correlation with, only, precipitation. Although it was observed toxicity of underground water in the Landfill Area, there was no evidence of water contamination by leachate, however, due to the toxic character of this water, additional tests should be conducted to confirm the quality of water that is used for human supply. At point E there was no acute toxicity. These results support the dangers of inappropriate disposal of MSW to water bodies due to the high toxicity of the leachate produced highlighting the necessity of places of safe confinement and a treatment system more effective to it
Resumo:
One of the concerns of this century is with the handling and the final destination of urban solid waste (RSU), where depending on the form as they will be made use, they can cause diverse problems, they are of ambient or social order, being able to generate the loss of the quality of life and illnesses to the population, of direct or indirect form. The objective of the present work was to diagnosis the environmental partner situation of the Final Destination of the urban solid residues in the District of Guajiru, city of São Gonçalo do Amarante/RN, standing out the partner-economic situation of the scavengers. The research was carried through in the period of March of 2008 the October of 2009, with a methodology developed through analyzes them of documents made available for the state ambient agency, the Air base of Christmas and managing agencies of the city. For collection of the date, it was used directly application of the questionnaire with 20 existing scavengers in points of destination of residues, evaluation of the old place of final destination through the use of the spread sheet of the IQR (Index of Quality of the Residues), developed for the CETESB, identification of the matter dump and photographic register. For effect of treatment of the data, a descriptive analysis with regard to the answers of the interviewed scavengers was carried through. The acquired date, Scale had been according to tabulated and analyzed in Excel 2003, where they had been generated graphical to observe the behavior of the data. The results show that of the twenty interviewed scavengers, 35% possess age between 20 and 30 years; 75% possess incomplete basic education; 60% inhabit in houses of waal or huts (cardboard or wood); 55% do not make use of system of water supply and system of sanitary exhaustion; with regard to income monthly for scavengers, 35% had presented income between R$ 200,00 and R$300,00 and 20% possess income above of R$ 500,00 for possessing another source of income; 80% of the interviewed ones, use some type of equipment of individual protection; In the year of 2009, confirming what it was informed by the State agency of Environment, during the field visit, we evidence that the city of Is Gonçalo do Amarante, currently, destines its residues in Sanitary landfill of São Region Metropolitan of Natal in the District of Massaranduba in the city of Ceará-Mirim, after some interventions of the State Public prosecution service. However, in the district of Guajiru some diggings still exist that today are used as final destination of RCD' s (Residues of Construction and Demolition) of the cities of Natal and São Gonçalo do Amarante, as well as private dumps that are used by scavengers that deviate the final destination (Sanitary landfill) of the residues of the great generators (supermarkets, shopping Center and hotels), with presence of urubus, generating a new ambient problem for the city and the aeroportuária security. Ahead of this scene, the study it suggests viable alternatives for the elimination of the private dumps and for the social situation of the escavengers, aiming at to improve its quality of life and 10 to minimize the ambient impacts caused by the inadequate destination of the solid waste in the community of Guajiru, São Gonçalo do Amarante/RN, being able to contribute so that the public managers carry through action in the handling and the control of the final destination of the urban solid waste
Resumo:
This study presents a comparative analysis of methodologies about weighted factors considered in the selection of areas for deployment of Sanitary Landfills, applying the methodologies of classification criteria with scoring bands Gomes, Coelho, Erba & Veronez (2000); Waquil et al, 2000. That means, we have the Scoring System used by Union of Municipalities of Bahia and the Quality Index Landfill Waste (IQR) which are applyed for this study in Massaranduba Sanitary Landfill located in the municipality of Ceará Mirim /RN, northeastern of Brazil. The study was conducted in order to classify the methodologies and to give support for future studies on environmental management segment, with main goal to propose suited methodologies which allow safety and rigor during the selection, deployment and management of sanitary landfill, in the Brazilian municipalities, in order to help them in the process to extinction of their dumps, in according of Brazilian Nacional Plan of Solid Waste. During this investigation we have studied the characteristics of the site as morphological, hydrogeological, environmental and socio-economic to permit the installation. We consider important to mention the need of deployment from Rio Grande do Norte State Secretary of Environment and Water (SEMARH), Institute of Sustainable Development and Environment of RN (IDEMA), as well, from Federal and Municipal Governments a public policies for the integrated management of urban solid waste that address environmental preservation and improvement of health conditions of the population of the Rio Grande do Norte
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Este estudo avalia sistemas de reciclagem e de disposição de resíduos sólidos domésticos que possuem incentivos fiscais definidos pela Lei Estadual nº 13.803/2000 de Minas Gerais. A pesquisa foi desenvolvida por análise de documentação de licenciamento ambiental de aterros sanitários e usinas de reciclagem e compostagem de resíduos financiados pela referida Lei e por visitas às unidades sanitárias, sendo usados os instrumentos metodológicos da agência ambiental do Estado de São Paulo (CETESB) que avaliam as condições de instalação e operação desses tipos de empreendimentos. do estudo, constatou-se que o incentivo de Minas Gerais, definido pela Lei do ICMS Ecológico, traz importantes benefícios ambientais aos municípios, embora ainda seja reduzido o número dos contemplados por esse fomento à gestão dos resíduos sólidos urbanos. Conclui-se, também, que algumas das unidades estudadas apresentam problemas de natureza ambiental e operacional.
Resumo:
This paper presents two case histories from Brazil where geophysical and resistivity piezocone tests were carried out to detect contamination. At the first one, the site investigation program was carried out to detect salt-water intrusions in a superficial sedimentary aquifer, at the Paranaguá harbor, in Paraná State. The second case history is a sanitary landfill from Bauru City, São Paulo State. In both sites, superficial geophysical tests were interpreted to detect and delineate the shape of contamination plume, helping to locate the resistivity piezocone tests. It was found that the interpretation of resistivity piezocone tests is straightforward to assess salt-water intrusion in sedimentary sands. For tropical soils, this technique presented some limitations since the groundwater table sometimes is deeper than the layer penetratable to the cone. Moreover, the genesis of those soils affects soil behavior and soil and water sampling is required to support interpretation.
Resumo:
The current technological development made by the absorption refrigeration system is an economic and ambient alternative in comparison to the vapor cycle, possessing an advantage that uses thermal energy that is less noble. Chillers of absorption are used widely in the air conditioned industries, because they can be set in motion through hot water vapors that burn natural gas, solar energy, biomasses amongst others instead of electricity. These systems allow it to reduce the tips of electric demand and balance the rocking of energy demand. This work has had a main objective to simulate a absorption refrigeration cycle with lithium-water bromide solution using biogas of sanitary landfill, and mixtures of this with natural gas. These results shown to the energy viability of the system burning biogas and its mixtures with natural gas in the generator, when compared with equipments that uses traditional fuels (natural gas, oil diesel, amongst others), for operation the commercial chillers with 15 kW of the refrigeration capacity and temperature of the water in the entrance of 14°C and the exit of 7°C.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Geociências e Meio Ambiente - IGCE
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)