817 resultados para Sagittal abdominal diameter
Resumo:
Purpose: The aim of this in vitro study was to assess the biomechanical stability of 9 different osteosynthesis methods after sagittal split ramus osteotomy by simulating the masticatory forces and using a 3-point biomechanical test method.Materials and Methods: Forty-five polyurethane hemimandibles with bone-like consistency were randomly assigned to 9 groups (n = 5) and subjected to sagittal split ramus osteotomy. After 4-mm advancement of the distal segment, the bone segments were fixed by different osteosynthesis methods using 2.0-mm miniplate/screw systems: group A, one 4-hole conventional straight miniplate; group B, one 4-hole locking straight miniplate; group C, one 4-hole conventional miniplate and one bicortical screw; group D, one 4-hole locking miniplate and 1 bicortical screw; group E, one 6-hole conventional straight miniplate; group F, one 6-hole locking straight miniplate; group (3: two 4-hole conventional straight miniplates; group H. two 4-hole locking straight miniplates; and group 1, 3 bicortical screws in an inverted-L. pattern. All models were mounted on a base especially constructed for this purpose. Using a 3-point biomechanical test model, the hemimandibles were loaded in compressive strength in an Instron machine (Norwood, MA) until a 3-mm displacement occurred between segments vertically or horizontally. Data were analyzed by analysis of variance and Tukey test (alpha = 1%).Results: The multiparametric comparison of the groups showed a statistically significant difference (P<.01) between groups that used 2 miniplates (groups G and H), 1 miniplate and 1 bicortical screw (groups C and D), and only bicortical screws (group D compared with groups that used only 1 miniplate with 2 screws per segment (groups A and B) and 3 screws per segment (groups E and F).Conclusion: The placement of 2.0-mm-diameter bicortical screws in the retromolar region, associated or not with conventional and locking miniplates with monocortical screws, promoted a better stabilization of bone segments. Locking miniplates presented a better performance in bone fixation in all groups. (C) 2010 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 68:724-730, 2010
Resumo:
Purpose: Numerous "in vitro" investigations have been conducted to evaluate the role of screw size and pattern in determining optimal resistance to deformation, often these have been controversial. The aim of this study was to evaluate the effect of screw size and insertion technique on the stability of sagittal split osteotomies.Materials and methods: This study used twenty polyurethane replicas of human hemimandibles with a prefabricated sagittal split ramus osteotomy (SSRO). The hemimandibles were stabilized with 1.5 mm and 2.0 mm titanium screws inserted in an inverted L configuration. All specimens were tested to determine the strength and stability of the fixation.Results: In all cases there was failure of the synthetic bone before there was any evidence of screw failure. There were no significant differences in the load necessary to make the construct fail between the 1.5 or 2.0 mm screw sizes.Conclusion: There was no statistically significant difference between the strengths achieved with screws of 1.5 and 2.0 mm diameters for fixation of SSRO performed in synthetic mandibles. There was no fracture of the 1.5 mm or 2.0 mm diameter screws in any of the tests. 1.5 mm diameter screws in an inverted L pattern have as much stability and mechanical resistance as a 2.0 mm screw, may be safely used for this procedure. (C) 2010 European Association for Cranio-Maxillo-Facial Surgery.
Resumo:
The present paper deals with the evaluation of morphological and morphometric alterations of slow-twist (I) and fast-twitch (II) fibers of rectus abdominis muscle of adult female dog during pregestational phase, at 30 and 60 days of pregnancy and at 30 days after the parturition. At the every phases, using the open biopsy technique, muscle samples were collected. The samples were plunged. Histological sections were cut in a microtome. For general morphology, some sections were stained with HE. Subsequent sections were reacted for myofibrillar ATPase (m-ATPase), after alkaline (pH 10.4) and acid (pH 4.4) pre-incubations, in order to identificate type I and II fibers. In the pre-gestational phase, muscle tissue revealed to be composed by fibers with different diameters, presenting polygonal outlines and one or more periphery nuclei. At 30 days of pregnancy, muscle fiber characteristics were similar. At 60 days, in addition to the existence of normal fibers, polymorphic and small diameter fibers were frequent. At 30 days after the parturation, the morphology of muscle fiber were similar to that observed in the pre-gestational phase. In the four phases, type II fiber diameters were lager than type I. The diameters of both fiber types showed a significant reduction in the 30 days phase and a significative increasing at 60 days. The expansion of the abdominal wall during the pregnancy represents a chronic stimulus, induced changes in the morphology and in the fiber type diameters.
Resumo:
The diameters and areas of portal vein, caudal vena cava and abdominal aorta are useful measurements in dogs. These values can be easily measured by ultrasonographic exam, and variations of normality can be an important indicator of hepatic or extra-hepatic alterations. This study aimed to measure the diameter and areas of portal vein, caudal vena cava and abdominal aorta in healthy dogs, with normal corporal score, divided in groups according to the body weight, and assess whether the data are influenced by animal weight. Thirty dogs were examined and divided into three groups (Group A: ≤ 10 kg Group B: from 10.1 to 20.0 kg; Group C: ≥ 20.1 kg). To measure the diameters and areas of portal vein, caudal vena cava and abdominal aorta, the animal was kept in left lateral decubitus position and the transducer was placed on the right lateral abdominal wall, at approximately the 10 th or 11 th intercostal space, in the porta hepatis region. The diameters and areas of the portal vein, caudal vena cava and abdominal aorta were significantly lower for dogs in Group A with respect to other groups and the dogs from Groups B and C had similar results with each other. The diameters and areas of the portal vein, caudal vena cava and abdominal aorta may vary with the animal size, and reference values must be specific for small, medium and large dogs.
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
Giant aortic aneurysms (transverse diameter greater than 10.0 cm) are rare and open surgery is often the treatment of choice. We report an infrarenal saccular giant aortic aneurysm (measuring 25 cm in transverse diameter), which was treated with endovascular repair, with immediate technical success. No similar report of a giant infrarenal aortic aneurysm treated with an endovascular technique was found in the literature. High-risk patients could possibly benefit from the endovascular technique. Nevertheless, patient survival remains strongly influenced by comorbidities.
Resumo:
The diameters and areas of portal vein, caudal vena cava and abdominal aorta are useful measurements in dogs. These values can be easily measured by ultrasonographic exam, and variations of normality can be an important indicator of hepatic or extra-hepatic alterations. This study aimed to measure the diameter and areas of portal vein, caudal vena cava and abdominal aorta inhealthy dogs, with normal corporal score, divided in groups according to the body weight, and assess whether the data are influenced by animal weight. Thirty dogs were examined and divided into three groups (Group A: ≤ 10 kg Group B: from 10.1 to 20.0 kg; Group C: ≥ 20.1 kg). To measure thediameters and areas of portal vein, caudal vena cava and abdominal aorta, the animal was kept in left lateral decubitus position and the transducer was placed on the right lateral abdominal wall, at approximately the 10th or 11th intercostal space, in the porta hepatis region. The diameters and areas of the portal vein, caudal vena cava and abdominal aorta were significantly lower for dogs in Group A with respect to other groups and the dogs from Groups B and C had similar results with each other. The diameters and areas of the portal vein, caudal vena cava and abdominal aorta may vary with the animal size, and reference values must be specific for small, medium and large dogs. Key words: abdominal vessels; area; diameter; measurement; ultrasonographic exam
Resumo:
BACKGROUND: Integrity of the abdominal aortic aneurysm (AAA) neck is crucial for the long-term success of endovascular AAA repair (EVAR). However, suitable tools for reliable assessment of changes in small aortic volumes are lacking. The purpose of this study was to assess the intraobserver and interobserver variability of software-enhanced 64-row computed tomographic angiography (CTA) AAA neck volume measurements in patients after EVAR. METHODS: A total of 25 consecutive patients successfully treated by EVAR underwent 64-row follow-up CTA in 1.5-mm collimation. Manual CTA measurements were performed twice by three blinded and independent readers in random order with at least a 4-week interval between readings. Maximum and minimum transverse aortic neck diameters were measured twice on two different levels within the proximal neck. Volumetry of the proximal aortic neck was performed by using dedicated software. Variability was calculated as 1.96 SD of the mean arithmetic difference according to Bland and Altman. Two-sided and paired t tests were used to compare measurements. P values <.05 were considered to indicate statistical significance. RESULTS: Intraobserver agreement was excellent for dedicated aneurysmal neck volumetry, with mean differences of less than 1 mL (P > .05), whereas it was poor for transverse aortic neck diameter measurements (P < .05). However, interobserver variability was statistically significant for both neck volumetry (P < .005) and neck diameter measurements (P < .015). CONCLUSIONS: The reliability of dedicated AAA neck volumetry by using 64-row CTA is excellent for serial measurements by individual readers, but not between different readers. Therefore, studies should be performed with aortic neck volumetry by a single experienced reader.
Resumo:
OBJECTIVE: Anemia is a common comorbid condition in various inflammatory states and an established predictor of mortality in patients with chronic heart failure, ischemic heart disease, and end-stage renal disease. The present study of patients with abdominal aortic aneurysm (AAA) undergoing endovascular repair (EVAR) assessed the relationships between baseline hemoglobin concentration and AAA size, as well as anemia and long-term survival. METHODS: Between March 1994 and November 2006, 711 patients (65 women, mean age 75.8 +/- 7.8 years) underwent elective EVAR. Anemia was defined as a hemoglobin level <13 g/dL in men and <12 g/dL in women. Post-EVAR mean follow-up was 48.3 +/- 32.0 months. Association of hemoglobin level with AAA size was assessed with multiple linear regression. Mortality was determined with use of the internet-based Social Security Death Index and the electronic hospital record. Kaplan-Meier survival curves of anemic and nonanemic patient groups were compared by the log-rank method. Multivariable logistic regression models were used to determine the influence of anemia on vital status after EVAR. RESULTS: A total of 218/711 (30.7%) of AAA patients undergoing EVAR had anemia at baseline. After adjustment for various risk factors, hemoglobin level was inversely related to maximum AAA diameter (beta: - .144, 95%-CI: -1.482 - .322, P = .002). Post-EVAR survival was 65.5% at 5 years and 44.4% at 10 years. In long-term follow-up, survival was significantly lower in patients with anemia as compared to patients without anemia (P < .0001 by log-rank). Baseline hemoglobin levels were independently related to long-term mortality in multivariable Cox regression analysis adjusted for various risk factors (adjusted HR: 0.866, 95% CI: .783 to .958, P = .005). Within this model, statin use (adjusted HR: .517, 95% CI: .308 to .868, P = .013) was independently related to long-term survival, whereas baseline AAA diameter (adjusted HR: 1.022, 95% CI: 1.009 to 1.036, P = .001) was an independently associated with increased mortality. CONCLUSIONS: Baseline hemoglobin concentration is independently associated with AAA size and reduced long-term survival following EVAR. Thus, the presence or absence of anemia offers a potential refinement of existing risk stratification instruments.
Resumo:
PURPOSE: To compare clinical outcomes of endovascular and open aortic repair of abdominal aortic aneurysms (AAAs) in young patients at low risk. It was hypothesized that endovascular aneurysm repair (EVAR) compares favorably with open aneurysm repair (OAR) in these patients. MATERIALS AND METHODS: Twenty-five patients aged 65 years or younger with a low perioperative surgical risk profile underwent EVAR at a single institution between April 1994 and May 2007 (23 men; mean age, 62 years+/-2.8). A sex- and risk-matched control group of 25 consecutive patients aged 65 years or younger who underwent OAR was used as a control group (23 men; mean age, 59 years+/-3.9). Patient outcomes and complications were classified according to Society of Vascular Surgery/International Society for Cardiovascular Surgery reporting standards. RESULTS: Mean follow-up times were 7.1 years+/-3.2 after EVAR and 5.9 years+/-1.8 after OAR (P=.1020). Total complication rates were 20% after EVAR and 52% after OAR (P=.0378), and all complications were mild or moderate. Mean intensive care unit times were 0.2 days+/-0.4 after EVAR and 1.1 days+/-0.4 after OAR (P<.0001) and mean lengths of hospital stay were 2.3 days+/-1.0 after EVAR and 5.0 days+/-2.1 after OAR (P<.0001). Cumulative rates of long-term patient survival did not differ between EVAR and OAR (P=.144). No AAA-related deaths or aortoiliac ruptures occurred during follow-up for EVAR and OAR. In addition, no surgical conversions were necessary in EVAR recipients. Cumulative rates of freedom from secondary procedures were not significantly different between the EVAR and OAR groups (P=.418). Within a multivariable Cox proportional-hazards analysis adjusted for patient age, maximum AAA diameter, and cardiac risk score, all-cause mortality rates (odds ratio [OR], 0.125; 95% CI, 0.010-1.493; P=.100) and need for secondary procedures (OR, 5.014; 95% CI, 0.325-77.410; P=.537) were not different between EVAR and OAR. CONCLUSIONS: Results from this observational study indicate that EVAR offers a favorable alternative to OAR in young patients at low risk.
Resumo:
Abdominal aortic aneurysms (AAA) confer a substantial healthcare burden in the Western world. Surgical or endovascular therapy is indicated in patients with a maximum diameter exceeding 5.5 cm. Patients with smaller AAA must undergo a specific ultrasound surveillance program aimed at avoiding exposure to an increased risk of rupture once their AAA exceeds the threshold for active treatment. Based on improved understanding of the pathophysiology of AAA, recent years provided initial insight into potential medical treatment options. The presence of AAA is currently regarded a coronary artery disease risk equivalent. ACE inhibitors, statins and JNK-inhibitors were shown to have the potential to slow down progression. Since cigarette smoking is the main risk factor for both the development and progression of AAA, smoking cessation remains a key goal. Further prospective studies will assess the clinical efficacy of various promising drug treatment approaches aimed at slowing disease progression of small AAA and after endovascular therapy.
Resumo:
AIMS In this work, we provide novel insight into the morphology of dissecting abdominal aortic aneurysms in angiotensin II-infused mice. We demonstrate why they exhibit a large variation in shape and, unlike their human counterparts, are located suprarenally rather than infrarenally. METHODS AND RESULTS We combined synchrotron-based, ultra-high resolution ex vivo imaging (phase contrast X-Ray tomographic microscopy) with in vivo imaging (high-frequency ultrasound and contrast-enhanced micro-CT) and image-guided histology. In all mice, we observed a tear in the tunica media of the abdominal aorta near the ostium of the celiac artery. Independently we found that, unlike the gradual luminal expansion typical for human aneurysms, the outer diameter increase of angiotensin II-induced dissecting aneurysms in mice was related to one or several intramural haematomas. These were caused by ruptures of the tunica media near the ostium of small suprarenal side branches, which had never been detected by the established small animal imaging techniques. The tear near the celiac artery led to apparent luminal dilatation, while the intramural haematoma led to a dissection of the tunica adventitia on the left suprarenal side of the aorta. The number of ruptured branches was higher in those aneurysms that extended into the thoracic aorta, which explained the observed variability in aneurysm shape. CONCLUSION Our results are the first to describe apparent luminal dilatation, suprarenal branch ruptures, and intramural haematoma formation in dissecting abdominal aortic aneurysms in mice. Moreover, we validate and demonstrate the vast potential of phase contrast X-ray tomographic microscopy in cardiovascular small animal applications.
Resumo:
OBJECTIVES To compare biomechanical rupture risk parameters of asymptomatic, symptomatic and ruptured abdominal aortic aneurysms (AAA) using finite element analysis (FEA). STUDY DESIGN Retrospective biomechanical single center analysis of asymptomatic, symptomatic, and ruptured AAAs. Comparison of biomechanical parameters from FEA. MATERIALS AND METHODS From 2011 to 2013 computed tomography angiography (CTA) data from 30 asymptomatic, 15 symptomatic, and 15 ruptured AAAs were collected consecutively. FEA was performed according to the successive steps of AAA vessel reconstruction, segmentation and finite element computation. Biomechanical parameters Peak Wall Rupture Risk Index (PWRI), Peak Wall Stress (PWS), and Rupture Risk Equivalent Diameter (RRED) were compared among the three subgroups. RESULTS PWRI differentiated between asymptomatic and symptomatic AAAs (p < .0004) better than PWS (p < .1453). PWRI-dependent RRED was higher in the symptomatic subgroup compared with the asymptomatic subgroup (p < .0004). Maximum AAA external diameters were comparable between the two groups (p < .1355). Ruptured AAAs showed the highest values for external diameter, total intraluminal thrombus volume, PWS, RRED, and PWRI compared with asymptomatic and symptomatic AAAs. In contrast with symptomatic and ruptured AAAs, none of the asymptomatic patients had a PWRI value >1.0. This threshold value might identify patients at imminent risk of rupture. CONCLUSIONS From different FEA derived parameters, PWRI distinguishes most precisely between asymptomatic and symptomatic AAAs. If elevated, this value may represent a negative prognostic factor for asymptomatic AAAs.
Resumo:
A complex response of the trunk muscles occurs to restore equilibrium in response to movement of the support surface. Intra-abdominal pressure (IAP) is considered to contribute to control of the trunk. This study investigated the contribution of IAP to the postural response to multidirection support-surface translation. IAP was recorded with a thin-film pressure transducer inserted via the nose into the stomach and trunk motion was recorded with an optoelectronic system with markers over the spinous process of L1. A pattern of trunk movement was recorded in response to the support-surface translations that was consistent with a 'hip' strategy of postural control. The trunk moved in a manner appropriate to move the centre of gravity over the new base of support. IAP was increased with movement in each direction, but varied in timing and amplitude between translation directions. In general, the IAP was greater with translations in the sagittal plane compared to the frontal plane and was initiated earlier for translations in the backward direction. These data indicate that IAP contributes to the postural response associated with support-surface translation and suggest that this is consistent with stiffening the spine. (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
The aim of the present study was to examine body concern and satisfactions in 191 female university students and their relationships with measured body composition and circumferences of selected body parts. Body composition and circumference measurements of participants were conducted after obtaining their consent. Body concern and satisfaction were determined using the Body Shape Questionnaire (BSQ) and the Body parts and General subscales from the Body Satisfaction Scales (BSS). Increase in body composition and circumferences were associated with decrease in body concern and satisfaction. Increase in body size, including circumferences did not decrease whole body satisfaction but increased dissatisfaction at the abdominal, arm and thigh regions.