998 resultados para SELF-EXPANDABLE METALLIC STENT


Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS Patients with ST-segment elevation myocardial infarction (STEMI) feature thrombus-rich lesions with large necrotic core, which are usually associated with delayed arterial healing and impaired stent-related outcomes. The use of bioresorbable vascular scaffolds (Absorb) has the potential to overcome these limitations owing to restoration of native vessel lumen and physiology at long term. The purpose of this randomized trial was to compare the arterial healing response at short term, as a surrogate for safety and efficacy, between the Absorb and the metallic everolimus-eluting stent (EES) in patients with STEMI. METHODS AND RESULTS ABSORB-STEMI TROFI II was a multicentre, single-blind, non-inferiority, randomized controlled trial. Patients with STEMI who underwent primary percutaneous coronary intervention were randomly allocated 1:1 to treatment with the Absorb or EES. The primary endpoint was the 6-month optical frequency domain imaging healing score (HS) based on the presence of uncovered and/or malapposed stent struts and intraluminal filling defects. Main secondary endpoint included the device-oriented composite endpoint (DOCE) according to the Academic Research Consortium definition. Between 06 January 2014 and 21 September 2014, 191 patients (Absorb [n = 95] or EES [n = 96]; mean age 58.6 years old; 17.8% females) were enrolled at eight centres. At 6 months, HS was lower in the Absorb arm when compared with EES arm [1.74 (2.39) vs. 2.80 (4.44); difference (90% CI) -1.06 (-1.96, -0.16); Pnon-inferiority <0.001]. Device-oriented composite endpoint was also comparably low between groups (1.1% Absorb vs. 0% EES). One case of definite subacute stent thrombosis occurred in the Absorb arm (1.1% vs. 0% EES; P = ns). CONCLUSION Stenting of culprit lesions with Absorb in the setting of STEMI resulted in a nearly complete arterial healing which was comparable with that of metallic EES at 6 months. These findings provide the basis for further exploration in clinically oriented outcome trials.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS The Absorb bioresorbable vascular scaffold (Absorb BVS) provides similar clinical outcomes compared with a durable polymer-based everolimus-eluting metallic stent (EES) in stable coronary artery disease patients. ST-elevation myocardial infarction (STEMI) lesions have been associated with delayed arterial healing and impaired stent-related outcomes. The purpose of the present study is to compare directly the arterial healing response, angiographic efficacy and clinical outcomes between the Absorb BVS and metallic EES. METHODS AND RESULTS A total of 191 patients with acute STEMI were randomly allocated to treatment with the Absorb BVS or a metallic EES 1:1. The primary endpoint is the neointimal healing (NIH) score, which is calculated based on a score taking into consideration the presence of uncovered and malapposed stent struts, intraluminal filling defects and excessive neointimal proliferation, as detected by optical frequency domain imaging (OFDI) six months after the index procedure. The study will provide 90% power to show non-inferiority of the Absorb BVS compared with the EES. CONCLUSIONS This will be the first randomised study investigating the arterial healing response following implantation of the Absorb BVS compared with the EES. The healing response assessed by a novel NIH score in conjunction with results on angiographic efficacy parameters and device-oriented events will elucidate disease-specific applications of bioresorbable scaffolds.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Morbid obesity is an epidemic and complex disease which imposes a multidisciplinary approach. Laparoscopic sleeve gastrectomy has become a frequent procedure given its effi- cacy and safety compared to other surgical options. However, it isn’t free from complications. Lax gastric fixation or incorrect positioning of the stomach during surgery can result in early gastric outlet obstruction caused by a volvulus-like mechanism by rotation of the stomach around its anatomic axes. This report refers to two cases of post sleeve gastric torsion resulting in persisting vomiting after initiating oral intake. The diagnosis was confirmed by upper gastrointestinal-contrast study and gastroscopy. In both cases, a fully covered self-expandable metallic stentwas insertedwhich prompted the gastric lumen to become permeable resulting in symptomatic resolution. The stents were removed endoscopically aftertwo and three months. Beyond more than three years offollow-up,the patients remain asymptomatic and no recurring ‘‘stenosis’’ was noticed.In these cases the use offully covered self-expandable metallic stents demonstrated to be effective and safe in the treatment of post sleeve gastric torsion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The limitations of the medical management of symptomatic intracranial arterial stenosis encourage the development of new therapeutic strategies such as intracranial stenting. OBJECTIVE: To report and analyze the results of a series of 42 patients treated with 3 different endovascular techniques: isolated angioplasty, balloon-expandable coronary stents, and the Wingspan self-expandable intracranial stent system. METHODS: Forty-two patients presenting with symptomatic intracranial arterial stenosis were treated with one of these techniques. Computed tomography angiography was performed 6 months after the procedure, and the clinical neurological statuses were categorized using the modified Rankin Scale and the National Institutes of Health Stroke Scale. RESULTS: A total of 42 lesions were treated: 9 with isolated angioplasty, 14 with balloon-expandable coronary stents, and 19 with Wingspan self-expandable intracranial stents. The mean patient age was 62.9 years, and the mean arterial diameter stenosis was 73.9%. Technical success was achieved in 97.6% of the patients. The overall incidence of procedural complications was 21.4%, and the postoperative permanent morbidity/mortality rate was 7.1%. There were 3 cases of in-stent thrombosis (1 fatal) and 5 cases of asymptomatic restenosis (11.9%), 3 in the isolated angioplasty group and 2 in the Wingspan self-expandable intracranial stent group (mean follow-up 20.4 months). The rate of restenosis was higher in the angioplasty group (33%) than in the coronary (0%) and Wingspan stent (10.5%) groups. CONCLUSION: Endovascular treatment of symptomatic intracranial stenosis has significant overall morbidity and mortality rates. Nevertheless, the very critical natural history of severe refractory lesions and the relatively favorable postoperative evolution suggest that it should be considered the first alternative strategy in cases in which medical therapy has failed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIM: To evaluate the results of duodenal stenting for palliation of gastroduodenal malignant obstruction by using a gastric outlet obstruction score (GOOS). METHODS: A prospective, non-randomized study was performed at a tertiary center between August 2005 and April 2010. Patients were eligible if they had malignant gastric outlet obstruction (GOO) and were not candidates for surgical treatment. Medical history and patient demographics were collected at baseline. Scheduled interviews were made on the day of the procedure and 15, 30, 90 and 180 d later or unscheduled as necessary. RESULTS: Fifteen patients (6 male, 9 female; median age 61 years) with GOO who had undergone duodenal stenting were evaluated. Ten patients had metastasis at baseline (66.6%) and 14 were unable to accept oral intake (93.33%), including 7 patients who were using a feeding tube. Laboratory data showed biliary obstruction in eight cases (53.33%); all were submitted to biliary drainage. Two patients developed obstructive symptoms due to tumor ingrowth after 30 d and another due to tumor overgrowth after 180 d. Two cases of stent migration occurred. A good response to treatment was observed, with a mean time of approximately 1 d (19 h) until toleration of a liquid diet and slightly more than 2 d for both soft solids (51 h) and a solid food/normal diet (55 h). The mean time to first failure to maintain liquid intake (GODS >= 1) was 93 d. During follow-up, the mean time to first failure to maintain the previously achieved GODS of 2-3 (solid/semi-solid food), considered technical failure, was 71 d. On the basis of oral intake a GODS is defined: 0 for no oral intake; 1 for liquids only; 2 for soft solids only; 3 for low-residue or full diet. CONCLUSION: Enteral stenting to alleviate gastroduodenal malignant obstruction improves quality of life in patients with limited life expectancy, which can be evaluated by using a GOO scoring system. (C) 2012 Baishideng. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The treatment of complex aortic pathologies involving the ascending aorta, the aortic arch, and the descending aorta remains a challenging issue in aortic surgery. The frozen elephant trunk procedure effectively combines surgical and interventional technologies in the treatment of extensive aortic aneurysms and dissections. We present two patients with complex aortic lesions involving all three segments of the thoracic aorta. The device used in our series is the new E-vita open hybrid prosthesis consisting of a proximal woven polyester tube and a distal self-expandable nitinol stent graft, which can be delivered antegrade into the descending aorta.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: This study sought to investigate whether self-expanding stents are more effective than balloon-expandable stents for reducing stent malapposition at 3 days after implantation in patients with ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention. BACKGROUND: Acute myocardial infarction is associated with vasoconstriction and large thrombus burden. Resolution of vasoconstriction and thrombus load during the first hours to days after primary percutaneous coronary intervention may lead to stent undersizing and malapposition, which may subsequently lead to stent thrombosis or restenosis. In addition, aggressive stent deployment may cause distal embolization. METHODS: Eighty patients with ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention were randomized to receive a self-expanding stent (STENTYS, STENTYS SA, Paris, France) (n = 43) or a balloon-expandable stent (VISION, Abbott Vascular, Santa Clara, California; or Driver, Medtronic, Minneapolis, Minnesota) (n = 37) at 9 European centers. The primary endpoint was the proportion of stent strut malapposition at 3 days after implantation measured by optical coherence tomography. Secondary endpoints included major adverse cardiac events (cardiac death, recurrent myocardial infarction, emergent bypass surgery, or clinically driven target lesion revascularization). RESULTS: At 3 days after implantation, on a per-strut basis, a lower rate of malapposed stent struts was observed by optical coherence tomography in the self-expanding stent group than in the balloon-expandable group (0.58% vs. 5.46%, p < 0.001). On a per-patient basis, none of the patients in the self-expanding stent group versus 28% in the balloon-expandable group presented ≥5% malapposed struts (p < 0.001). At 6 months, major adverse cardiac events were 2.3% versus 0% in the self-expanding and balloon-expandable groups, respectively (p = NS). CONCLUSIONS: Strut malapposition at 3 days is significantly lower in ST-segment elevation myocardial infarction patients allocated to self-expanding stents when than in those allocated to balloon-expandable stents. The impact of this difference on clinical outcome and the risk of late stent thrombosis need to be evaluated further. (Randomized Comparison Between the STENTYS Self-expanding Coronary Stent and a Balloon-expandable Stent in Acute Myocardial Infarction [APPOSITION II]; NCT01008085).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction. Bronchial complications owing to the airway anastomosis in lung transplantation are important causes of morbidity and mortality. They occur in up to 27% of cases as defined by stenosis, necrosis, and dehiscence. Treatment depends on the type of complication. Objective. To report our experience to treat this complication. Methods. Between 2000 and 2007, we performed 71 lung transplants of which 36 were bilateral. The total number of anastomoses was 107:52 to the right and 55 to the left. The telescoping technique was initially used (14 initial unilateral transplants), and after October, 2003 it was changed to an end-to-end anastomosis (57 transplants and 93 anastomoses). Results. Eight patients developed bronchial complications including two that were bilateral. There were 4 stenosis, 3 dehiscences, and 3 necrosis complications (9.4%). The complication rate for telescoping anastomosis was 21.4%, and for the end-to-end technique, 7.5%. The treatment of the stenosis used metallic or plastic self-expandable stents. Two bronchial dehiscences resulted in case of bronchopleural fistulae, empyema, and death; the other patient experienced spontaneous resolution. Concerning bronchial necrosis, I patient developed fistulization to the pulmonary artery and massive hemoptysis, and the other with bilateral necrosis, a spontaneous resolution. Conclusion. Our bronchial anastomosis complication rate was comparable with that in other reports. The rate for the telescoping technique was greater compared with the end-to-end technique. The treatment of bronchial stenosis with a self-expandable prosthesis showed good results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The aim of this study was to investigate the feasibility of transventricular-transseptal approach (TVSA) for extrapleural transcatheter aortic valved stent implantation via a subxyphoidian access. Methods: In five porcine experiments (52.3 +/- 10.9 kg) the right ventricle was exposed via subxyphoidian access. Under the guidance of intracardiac echocardiography (ICE) and fluoroscopy, the transseptal access from right ventricle to left ventricle was created progressively by puncture and dilation with dilators (8F-26F). Valved stents built in-house from commercial tanned pericardium and self-expandable Nitinol stents were loaded into a cartridge. A delivery sheath was then introduced from the right ventricle into the left ventricle and then into the ascending aorta. The cartridge was connected and the valved stent was deployed in the aortic position. Then, the ventricular septal access was sealed with an Amplatzer septal occluder device and the right ventricular access was closed by tying prepared purse-string suture directly. Thirty minutes after the whole procedure, the animals were sacrificed for macroscopic evaluation of the position of valved stent and septal closure device. Result: Procedural success of TVSA was 100% at the first attempt. Mean procedure time was 49 +/- 4 min. Progressive dilatation of the transseptal access resulted in a measurable ventricular septal defect (VSD) after dilator sizes 18F and more. All valved stents were delivered at the target site over the native aortic valve with good acute valve function and no paravalvular leaks. During the procedure, premature beats (5/5) and supraventriclar tachycardias (5/5) were observed, but no atrial-ventricular block (0/5) occurred. Heart rate before (after) was 90 +/- 3 beats min(-1) (100 +/- 2 beats min(-1): p < 0.05), whereas blood pressure was 60 + 1 mm Hg (55 + 2 mm Hg (p < 0.05)). Total blood loss was 280 + 10 ml. The Amplatzer septal occluder devices were fully deployed and the ventricular septal accesses were sealed successfully, without detectable residual shunt. Conclusion: Trans-catheter implantation of aortic valved stent via extrapleural transventricular-transseptal access is technically feasible and has the potential for a simplified procedure under local anaesthesia. (C) 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B. V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Endovascular treatment of wide-neck bifurcation aneurysms often results in incomplete occlusion or aneurysm recurrence. The goals of this study were to compare results of coil embolization with or without the assistance of self-expandable stents and to examine how stents may influence neointima formation. MATERIALS AND METHODS: Wide-neck bifurcation aneurysms were constructed in 24 animals and, after 4-6 weeks, were randomly allocated to 1 of 5 groups: 1) coil embolization using the assistance of 1 braided stent (n = 5); 2) coil embolization using the assistance of 2 braided stents in a Y configuration (n = 5); 3) coil embolization without stent assistance (n = 6); 4) Y-stenting alone (n = 4); and 5) untreated controls (n = 4). Angiographic results were compared at baseline and at 12 weeks, by using an ordinal scale. Neointima formation at the neck at 12 weeks was compared among groups by using a semiquantitative grading scale. Bench studies were performed to assess stent porosities. RESULTS: Initial angiographic results were improved with single stent-assisted coiling compared with simple coiling (P = .013). Angiographic results at 12 weeks were improved with any stent assistance (P = .014). Neointimal closure of the aneurysm neck was similar with or without stent assistance (P = .908), with neointima covering coil loops but rarely stent struts. Y-stent placement alone had no therapeutic effect. Bench studies showed that porosities can be decreased with stent compaction, but a relatively stable porous transition zone was a limiting factor. CONCLUSIONS: Stent-assisted coiling may improve results of embolization by allowing more complete initial coiling, but these high-porosity stents did not provide a scaffold for more complete neointimal closure of aneurysms.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction Different modalities of palliation for obstructive symptoms in patients with unresectable esophageal cancer (EC) exist. However, these therapeutic alternatives have significant differences in costs and effectiveness. Methods A Markov model was designed to compare the cost-effectiveness (CE) of self-expandable stent (SES), brachytherapy and laser in the palliation of unresectable EC. Patients were assigned to one of the strategies, and the improvement in swallowing function was compared given the treatment efficacy, probability of survival, and risks of complications associated to each strategy. Probabilities and parameters for distribution were based on a 9-month time frame. Results Under the base-case scenario, laser has the lowest CE ratio, followed by brachytherapy at an incremental cost-effectiveness ratio (ICER) of $4,400.00, and SES is a dominated strategy. In the probabilistic analysis, laser is the strategy with the highest probability of cost-effectiveness for willingness to pay (WTP) values lower than $3,201 and brachytherapy for all WTP yielding a positive net health benefit (NHB) (threshold $4,440). The highest probability of cost-effectiveness for brachytherapy is 96%, and consequently, selection of suboptimal strategies can lead to opportunity losses for the US health system, ranging from US$ 4.32 to US$ 38.09 million dollars over the next 5-20 years. Conclusion Conditional to the WTP and current US Medicare costs, palliation of unresectable esophageal cancers with brachytherapy provides the largest amount of NHB and is the strategy with the highest probability of CE. However, some level of uncertainly remains, and wrong decisions will be made until further knowledge is acquired.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this report is to address the benefits of the minimal invasive venous drainage in a pediatric cardio surgical scenario. Juvenile bovine experiments (67.4+/-11 kg) were performed. The right atrium was cannulated in a trans-jugular way by using the self-expandable (Smart Stat, 12/20F, 430 mm) venous cannula (Smartcannula LLC, Lausanne, Switzerland) vs. a 14F 250 mm (Polystan Lighthouse) standard pediatric venous cannula. Establishing the cardiopulmonary bypass (CPB), the blood flows were assessed for 20 mmHg, 30 mmHg and 40 mmHg of driving pressure. Venous drainage (flow in l/min) at 20 mmHg, 30 mmHg, and 40 mmHg drainage load was 0.26+/-0.1, 0.35+/-0.2 and 0.28+/-0.08 for the 14F standard vs. 1.31+/-0.22, 1.35+/-0.24 and 1.9+/-0.2 for the Smart Stat 12/20F cannula. The 43 cm self-expanding 12/20F Smartcannula outperforms the 14F standard cannula. The results described herein allow us to conclude that usage of the self-expanding Smartcannula also in the pediatric patients improves the flow and the drainage capacity, avoiding the insufficient and excessive drainage. We believe that similar results may be expected in the clinical settings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Stent implantation was performed on two patients to treat chronic dissecting aneurysms of the upper cervical internal carotid artery. Treatment was decided because of the youth of the patients, their medical history of subarachnoid hemorrhage, and the angiographic findings associated with the dissection. Normal arteriographic morphology was obtained after deployment of a single self-expandable stent.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: The study aimed to evaluate the feasibility of off-pump transapical mitral valve-in-ring implantation and to test the performance of a custom-made self-expandable stent valve, in comparison with the standard SAPIEN valve. METHODS: Acute experiments were performed in five pigs. Animals (mean weight 58.4 ± 7.3 kg) underwent mitral valve annuloplasties under cardiopulmonary bypass using 26-mm rings (SJM?). Then, a 30-mm custom-made self-expandable stent valve or a 23-mm balloon-expandable transcatheter heart valve (Edwards SAPIEN XT?) was deployed within the annuloplasty rings through a transatrial access and under direct vision. Subsequently, the stent valves were inserted transapically under fluoroscopic guidance and off pump. RESULTS: The procedural success of transatrial and transapical mitral valve-in-ring procedures was 100% (10 of 10). Mean transatrial and transapical procedure time was 2.0 ± 1.1 and 22.0 ± 5.7 min, respectively. Haemodynamic status during transapical implantation remained stable, and differences in data collected before and after the stent-valve deployment were not statistically significant. Mean mitral annulus diameter and mean mitral orifice area in the group of self-expandable stent valves were 2.60 ± 0.02 cm and 4.16 ± 0.48 cm(2), respectively, whereas in the SAPIEN group they were 1.95 ± 0.18 cm and 2.26 ± 0.20 cm(2), respectively. Trace or mild regurgitation was detected only in the self-expandable stent-valve group. Mean gradients were 4.1 ± 4.5 mmHg across the self-expandable stent valves and 1.0 ± 0 mmHg across the SAPIEN valves. Postmortem examination confirmed adequate positioning of the self-expandable valves and the SAPIEN valves within the annuloplasty ring. CONCLUSIONS: Off-pump transapical mitral valve-in-ring implantation is safe and feasible. Transapical access may represent the ideal option for valve-in-ring procedures in cases of recurrent mitral regurgitation after mitral valve repair, in high-risk patients. Owing to the supra-annular profile of the valve components, our custom-made nitinol stent valve provides nearer to normal functional area than the SAPIEN valve.