26 resultados para SBRT
Resumo:
BACKGROUND AND PURPOSE: Compensation for respiratory motion is needed while administering radiotherapy (RT) to tumors that are moving with respiration to reduce the amount of irradiated normal tissues and potentially decrease radiation-induced collateral damages. The purpose of this study was to test a new ventilation system designed to induce apnea-like suppression of respiratory motion and allow long enough breath hold durations to deliver complex RT. MATERIAL AND METHODS: The High Frequency Percussive Ventilation system was initially tested in a series of 10 volunteers and found to be well tolerated, allowing a median breath hold duration of 11.6min (range 3.9-16.5min). An evaluation of this system was subsequently performed in 4 patients eligible for adjuvant breast 3D conformal RT, for lung stereotactic body RT (SBRT), lung volumetric modulated arc therapy (VMAT), and VMAT for palliative pleural metastases. RESULTS: When compared to free breathing (FB) and maximal inspiration (MI) gating, this Percussion Assisted RT (PART) offered favorable dose distribution profiles in 3 out of the 4 patients tested. PART was applied in these 3 patients with good tolerance, without breaks during the "beam on time period" throughout the overall courses of RT. The mean duration of the apnea-like breath hold that was necessary for delivering all the RT fractions was 7.61min (SD=2.3). CONCLUSIONS: This first clinical implementation of PART was found to be feasible, tolerable and offers new opportunities in the field of RT for suppressing respiratory motion.
Resumo:
La radiothérapie stéréotaxique corporelle (SBRT) est une technique couramment employée pour le traitement de tumeurs aux poumons lorsque la chirurgie n’est pas possible ou refusée par le patient. Une complication de l’utilisation de cette méthode provient du mouvement de la tumeur causé par la respiration. Dans ce contexte, la radiothérapie asservie à la respiration (RGRT) peut être bénéfique. Toutefois, la RGRT augmente le temps de traitement en raison de la plus petite proportion de temps pour laquelle le faisceau est actif. En utilisant un faisceau de photons sans filtre égalisateur (FFF), ce problème peut être compensé par le débit de dose plus élevé d’un faisceau FFF. Ce mémoire traite de la faisabilité d’employer la technique de RGRT en combinaison avec l’utilisation un faisceau FFF sur un accélérateur Synergy S (Elekta, Stockholm, Suède) avec une ceinture pneumatique, le Bellows Belt (Philips, Amsterdam, Pays-Bas), comme dispositif de suivi du signal respiratoire. Un Synergy S a été modifié afin de pouvoir livrer un faisceau 6 MV FFF. Des mesures de profils de dose et de rendements en profondeur ont été acquises en cuve à eau pour différentes tailles de champs. Ces mesures ont été utilisées pour créer un modèle du faisceau 6 MV FFF dans le système de planification de traitement Pinnacle3 de Philips. Les mesures ont été comparées au modèle à l’aide de l’analyse gamma avec un critère de 2%, 2 mm. Par la suite, cinq plans SBRT avec thérapie en arc par modulation volumétrique (VMAT) ont été créés avec le modèle 6 MV du Synergy S, avec et sans filtre. Une comparaison des paramètres dosimétriques a été réalisée entre les plans avec et sans filtre pour évaluer la qualité des plans FFF. Les résultats révèlent qu’il est possible de créer des plans SBRT VMAT avec le faisceau 6 MV FFF du Synergy S qui sont cliniquement acceptables (les crières du Radiation Therapy Oncology Group 0618 sont respectés). Aussi, une interface physique de RGRT a été mise au point pour remplir deux fonctions : lire le signal numérique de la ceinture pneumatique Bellows Belt et envoyer une commande d’irradiation binaire au linac. L’activation/désactivation du faisceau du linac se fait par l’entremise d’un relais électromécanique. L’interface comprend un circuit électronique imprimé fait maison qui fonctionne en tandem avec un Raspberry Pi. Un logiciel de RGRT a été développé pour opérer sur le Raspberry Pi. Celui-ci affiche le signal numérique du Bellows Belt et donne l’option de choisir les limites supérieure et inférieure de la fenêtre d’irradiation, de sorte que lorsque le signal de la ceinture se trouve entre ces limites, le faisceau est actif, et inversement lorsque le signal est hors de ces limites. Le logiciel envoie donc une commande d’irradiation au linac de manière automatique en fonction de l’amplitude du signal respiratoire. Finalement, la comparaison entre la livraison d’un traitement standard sans RGRT avec filtre par rapport à un autre plan standard sans RGRT sans filtre démontre que le temps de traitement en mode FFF est réduit en moyenne de 54.1% pour un arc. De la même manière, la comparaison entre la livraison d’un traitement standard sans RGRT avec filtre par rapport à un plan de RGRT (fenêtre d’irradiation de 75%) sans filtre montre que le temps de traitement de RGRT en mode FFF est réduit en moyenne de 27.3% par arc. Toutefois, il n’a pas été possible de livrer des traitements de RGRT avec une fenêtre de moins de 75%. Le linac ne supporte pas une fréquence d’arrêts élevée.
Resumo:
Se presentan las principales líneas de actuación del Instituto brasileño de informação em ciência e tecnologia (IBICT), actuando como facilitador de oportunidades de redes de información en pro de la superación de las barreras socioeconómicas y culturales, y de la inserción digital. El IBICT desarrolla estrategias que faciliten a la sociedad brasileña el acceso universal a la información por medio de las tecnologías de la información y la comunicación. Se muestran las bases del programa de inclusión social desarrollado por el IBICT, incluyendo una descripción de los proyectos de inclusión social y digital entro los que se incluyen: Mapa de inclusión digital en Brasil; Centro de referencia en inclusión digital (CENRID); Biblioteca Nacional de Brasilia; Corredor digital indígena; Corredor digital rural; Servicio brasileño de respuestas técnicas (SBRT); y Red de tecnología social (RTS).
Resumo:
In this work we propose procedures for the identification of structure of group associate lattices from fundamental region F4g of regular tessellations {4g; 4g} in the Euclidian plane and hyperbolic plane, where g denote genus of compact surface. © 2006 SBrT.
Resumo:
We assessed the efficacy and the toxicity for pediatric craniopharyngioma patients of fractionated stereotactic radiotherapy (FSRT). Between May 2000 and May 2009, 9 patients (male to female ratio, 5:4) with craniopharyngiomas underwent FSRT (median dose, 54 Gy). Among the 9 patients, 6 received radiation therapy (RT) for recurrent tumors and 3 for residual disease as adjuvant therapy after incomplete surgery. Median tumor 3 volume was 2.3 cm (range, 0.1-5.8). The median target coverage was 93.7% (range 79.3-99.8%). The median conformity index was 0.94 (range, 0.6-1.4). Dose to the hippocampal region was assessed for all patients. After a median follow-up of 62.5 months (range, 32-127)the treated volume decreased in size in four of eight patients (50%). One patient was lost to follow-up. Local control and survival rates at 3 years were 100% and there were no marginal relapses. One patient, with a chronic bilateral papillary oedema after surgery, visual defect deteriorated after FSRT to a complete hemianopsia. One male patient with normal pituitary function before FSRT presented with precocious puberty at the age of 7.4 years, 24 months after FSRT. Four patients (50%) were severely obese at their last visit. FSRT is a safe treatment option for craniopharyngioma after incomplete resection.
Resumo:
Objectives: We compare the dose parameters between 3 different radiosurgery delivery techniques which may have an impact on cochlea function. Methods: Five patients with unilateral vestibular schwannoma (VS) were selected for this study. Planning procedure was carried out using the BrainLAB® iPlan planning system v. 4.5. For each patient three different planning techniques were used: dynamic arc (DA) with 5 arcs per plan, hybrid arc (HA) with 5 arcs per plan and IMRT with 8 fields per plan. For each technique, two plans were generated with different methods: with the first method (PTV coverage) it was the goal to fully cover the PTV with at least 12 Gy (normalization: 12 Gy covered 99% of the PTV) and with the second method (cochlea sparing) it was the goal to spare the cochlea (normalization: 12 Gy covers 50% of the PTV/V4Gy of cochlea lower than 1%). Plan evaluation was done considering target volume and coverage (conformity and homogeneity) and OAR constraints (mean (Dmean) and maximum dose (Dmax) to cochlea, Dmax to brainstem and cochlea). The total number of monitor units (MU) was analyzed. Results: The median tumor volume was 0.95 cm³ (range, 0.86-3 cm³). The median PTV was 1.44 cm³ (range, 1-3.5 cm³). The median distance between the tumor and the cochlea's modiulus was 2.7 mm (range, 1.8-6.3 mm). For the PTV coverage method, when we compared the cochlear dose in VS patients planned with DA, HA and IMRT, there were no significant differences in Dmax (p = 0.872) and in Dmean (p= 0.860). We found a significant correlation (p< 0.05) between the target volume and the cochlear Dmean for all plans with Pearson's coefficient correlation of 0.90, 0.92 and 0.94 for the DA, HA and IMRT techniques, respectively. For the cochlea sparing method, when we compared the cochlear dose in VS patients planned with DA, HA and IMRT, there were no significant differences in Dmax (p = 0.310) and in Dmean (p= 0.275). However, in this group the V4Gy of the ipsilateral cochlea represents less than 1%. When using the HA or IMRT technique, the homogeneity and conformity in the PTV, but also the number of MUs were increased in comparison to the DA technique. Conclusion: VS tumors that extend distally into the IAC had an equivalent sparing of cochlea with DA approach compared with the HA and IMRT techniques. Disclosure: No significant relationships.
Resumo:
The effectiveness of the Anisotropic Analytical Algorithm (AAA) implemented in the Eclipse treatment planning system (TPS) was evaluated using theRadiologicalPhysicsCenteranthropomorphic lung phantom using both flattened and flattening-filter-free high energy beams. Radiation treatment plans were developed following the Radiation Therapy Oncology Group and theRadiologicalPhysicsCenterguidelines for lung treatment using Stereotactic Radiation Body Therapy. The tumor was covered such that at least 95% of Planning Target Volume (PTV) received 100% of the prescribed dose while ensuring that normal tissue constraints were followed as well. Calculated doses were exported from the Eclipse TPS and compared with the experimental data as measured using thermoluminescence detectors (TLD) and radiochromic films that were placed inside the phantom. The results demonstrate that the AAA superposition-convolution algorithm is able to calculate SBRT treatment plans with all clinically used photon beams in the range from 6 MV to 18 MV. The measured dose distribution showed a good agreement with the calculated distribution using clinically acceptable criteria of ±5% dose or 3mm distance to agreement. These results show that in a heterogeneous environment a 3D pencil beam superposition-convolution algorithms with Monte Carlo pre-calculated scatter kernels, such as AAA, are able to reliably calculate dose, accounting for increased lateral scattering due to the loss of electronic equilibrium in low density medium. The data for high energy plans (15 MV and 18 MV) showed very good tumor coverage in contrast to findings by other investigators for less sophisticated dose calculation algorithms, which demonstrated less than expected tumor doses and generally worse tumor coverage for high energy plans compared to 6MV plans. This demonstrates that the modern superposition-convolution AAA algorithm is a significant improvement over previous algorithms and is able to calculate doses accurately for SBRT treatment plans in the highly heterogeneous environment of the thorax for both lower (≤12 MV) and higher (greater than 12 MV) beam energies.
Resumo:
This report describes the development of a Markov model for comparing percutaneous radiofrequency ablation (RFA) and stereotactic body radiation therapy (SBRT) in terms of their cost-utility in treating isolated liver metastases from colorectal cancer. The model is based on data from multiple retrospective and prospective studies, available data on different utility states associated with treatment and complications, as well as publicly available Medicare costs. The purpose of this report is to establish a well-justified model for clinical management decisions. In comparison with SBRT, RFA is the most cost-effective treatment for this patient population. From the societal perspective, SBRT may be an acceptable alternative with an ICER of $28,673/QALY. ^
Resumo:
Guidelines report a wide range of options in locally advanced pancreatic cancer (LAPC): definitive chemotherapy or chemoradiotherapy or the emerging stereotactic body radiotherapy (SBRT) (+/- chemotherapy). On behalf of the AIRO (Italian Association of Radiation Oncology and Clinical Oncology) Gastrointestinal Study Group, we collected retrospective clinical data on 419 LAPC from 15 Italian centers. The study protocol (PAULA-1: Pooled Analysis in Unresectable Locally Advanced pancreatic cancer) was approved by institutional review board of S. Orsola-Malpighi Hospital (201/2015/O/OssN). From this large database we performed tree different studies. The first was a retrospective study about 56 LAPC treated with SBRT at a median biologically equivalent dose of 48 Gy +/- chemotherapy. We demonstrated a statistically significant impact of biologically equivalent dose based on an α/β ratio of 10Gy ≥ 48Gy for local control (LC) (p: 0.045) and overall survival (p: 0.042) in LAPC. The second was a retrospective matched-cohort case-control study comparing SBRT (40 patients) and chemoradiation (40 patients) in LAPC in terms of different endpoints. Our findings suggested an equivalence in terms of most outcomes among the two treatments and an advantage of SBRT in terms of LC (p: 0.017). The third study was a retrospective comparison of definitive chemotherapy, chemoradiotherapy and SBRT (+/- chemotherapy) in terms of different outcomes in LAPC. A predictive model for LC in LAPC was also developed reaching an AUC of 68% (CI 58,7%-77,4%). SBRT treatment emerged as a positive predictive factor for improved LC. Findings deriving from our three studies suggest that SBRT is comparable to standard of care (definitive chemotherapy and chemoradiotherapy) in terms of outcomes. SBRT seems to be an emerging therapeutic option in LAPC significantly improving local control. Furthermore, we have shown the potential of a predictive model for LC. Randomized trials are needed to compare these different therapeutic options in LAPC.