885 resultados para Respiration artificial


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Lung deposition of intravenous cephalosporins is low. The lung deposition of equivalent doses of ceftazidime administered either intravenously or by ultrasonic nebulization using either nitrogen-oxygen or helium-oxygen as the carrying gas of the aerosol was compared in ventilated piglets with and without experimental bronchopneumonia. Methods: Five piglets with noninfected lungs and 5 piglets with Pseudomonas aeruginosa experimental bronchopneumonia received 33 mg/kg ceftazidime intravenously. Ten piglets with noninfected lungs and 10 others with experimental P. aeruginosa bronchopneumonia received 50 mg/kg ceftazidime by ultrasonic nebulization. In each group, the ventilator was operated in half of the animals with a 65%/35% helium-oxygen or nitrogen-oxygen mixture. Animals were killed, and multiple lung specimens were sampled for measuring ceftazidime lung tissue concentrations by high-performance liquid chromatography. Results: As compared with intravenous administration, nebulization of ceftazidime significantly increased lung tissue concentrations (17 ± 13 vs. 383 ± 84 μg/g in noninfected piglets and 10 ± 3 vs. 129 ± 108 μg/g in piglets with experimental bronchopneumonia; P < 0.001). The use of a 65%/35% helium-oxygen mixture induced a 33% additional increase in lung tissue concentrations in noninfected piglets (576 ± 141 μg/g; P < 0.001) and no significant change in infected piglets (111 ± 104 μg/g). Conclusion: Nebulization of ceftazidime induced a 5- to 30-fold increase in lung tissue concentrations as compared with intravenous administration. Using a helium-oxygen mixture as the carrying gas of the aerosol induced a substantial additional increase in lung deposition in noninfected piglets but not in piglets with experimental bronchopneumonia. © 2005 American Society of Anesthesiologists, Inc. Lippincott Williams & Wilkins, Inc.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

INTRODUCTION: During mechanical ventilation (MV), the airways may accumulate secretions. Patients are submitted to Respiratory Therapy (RT) and tracheal aspiration when in MV, alone or associated, to eliminate these secretions. OBJECTIVE: The objective was to compare the effects of different protocols of bronchial hygiene in blood pressure, heart rate, oxygen saturation and respiratory rate of patients undergoing MV. MATERIALS AND METHODS: We conducted a prospective, randomized, controlled crossover, with intentional non-probabilistic sample in the Medical School Hospital of Marília. We included patients in invasive MV who were submitted to three different bronchial hygiene protocols: PP - physiotherapy protocol (manual chest compression and manual hyperinflation); AP - aspiration protocol; and PP + AP. Respiratory rate, systolic blood pressure (SBP), diastolic blood pressure (DBP), oxygen saturation and heart rate were evaluated in three moments: before (M1), immediately after (M2) and 30 minutes after (M3) for each protocol. The differences among protocols and times were assessed using ANOVA and post hoc Student Newman-Keus (p < 0.05). RESULTS: We studied eighteen 71.2 ± 13.9 year-old patients with 15.1 ± 17.7 days of MV. There were no differences among protocols. There was a significant decreasing in SBP (p = 0.0261) and DBP (p = 0.0119) from M2 to M3 in the aspiration protocol. CONCLUSION: There was a decrease of blood pressure on MV patients after 30 minutes of aspiration and no change in the other variables, and there was no difference among protocols.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BackgroundThis is an update of a Cochrane Review first published in The Cochrane Library, Issue 2, 2008.The technique called one-lung ventilation can confine bleeding or infection to one lung, prevent rupture of a lung cyst or, more commonly, facilitate surgical exposure of the unventilated lung. During one-lung ventilation, anaesthesia is maintained either by delivering an inhalation anaesthetic to the ventilated lung or by infusing an intravenous anaesthetic. It is possible that the method chosen to maintain anaesthesia may affect patient outcomes. Inhalation anaesthetics may impair hypoxic pulmonary vasoconstriction (HPV) and increase intrapulmonary shunt and hypoxaemia.ObjectivesThe objective of this review was to evaluate the effectiveness and safety of intravenous versus inhalation anaesthesia for one-lung ventilation.Search methodsWe searched the Cochrane Central Register of Controlled Trials (CENTRAL); The Cochrane Library (2012, Issue 11); MEDLINE (1966 to November 2012); EMBASE (1980 to November 2012); Literatura Latino-Americana e do Caribe em Ciencias da Saude (LILACS, 1982 to November 2012) and ISI web of Science (1945 to November 2012), reference lists of identified trials and bibliographies of published reviews. We also contacted researchers in the field. No language restrictions were applied. The date of the most recent search was 19 November 2012. The original search was performed in June 2006.Selection criteriaWe included randomized controlled trials and quasi-randomized controlled trials of intravenous (e. g. propofol) versus inhalation (e. g. isoflurane, sevoflurane, desflurane) anaesthesia for one-lung ventilation in both surgical and intensive care participants. We excluded studies of participants who had only one lung (i.e. pneumonectomy or congenital absence of one lung).Data collection and analysisTwo review authors independently assessed trial quality and extracted data. We contacted study authors for additional information.Main resultsWe included in this updated review 20 studies that enrolled 850 participants, all of which assessed surgical participants no studies investigated one-lung ventilation performed outside the operating theatre. No evidence indicated that the drug used to maintain anaesthesia during one-lung ventilation affected participant outcomes. The methodological quality of the included studies was difficult to assess as it was reported poorly, so the predominant classification of bias was 'unclear'.Authors' conclusionsVery little evidence from randomized controlled trials suggests differences in participant outcomes with anaesthesia maintained by intravenous versus inhalational anaesthesia during one-lung ventilation. If researchers believe that the type of drug used to maintain anaesthesia during one-lung ventilation is important, they should design randomized controlled trials with appropriate participant outcomes, rather than report temporary fluctuations in physiological variables.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: Patients with high cervical spinal cord injury are usually dependent on mechanical ventilation support, which, albeit life saving, is associated with complications and decreased life expectancy because of respiratory infections. Diaphragm pacing stimulation (DPS), sometimes referred to as electric ventilation, induces inhalation by stimulating the inspiratory muscles. Our objective was to highlight the indications for and some aspects of the surgical technique employed in the laparoscopic insertion of the DPS electrodes, as well as to describe five cases of tetraplegic patients submitted to the technique. Methods: Patient selection involved transcutaneous phrenic nerve studies in order to determine whether the phrenic nerves were preserved. The surgical approach was traditional laparoscopy, with four ports. The initial step was electrical mapping in order to locate the "motor points" (the points at which stimulation would cause maximal contraction of the diaphragm). If the diaphragm mapping was successful, four electrodes were implanted into the abdominal surface of the diaphragm, two on each side, to stimulate the branches of the phrenic nerve. Results: Of the five patients, three could breathe using DPS alone for more than 24 h, one could do so for more than 6 h, and one could not do so at all. Conclusions: Although a longer follow-up period is needed in order to reach definitive conclusions, the initial results have been promising. At this writing, most of our patients have been able to remain ventilator-free for long periods of time.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJETIVO: Pacientes com lesão medular cervical alta em geral são dependentes de ventilação mecânica, que, embora salve vidas, está associada a complicações e redução da expectativa de vida devido a infecções respiratórias. A estimulação do diafragma por marca-passo, às vezes chamada de ventilação elétrica, induz a inspiração por estimulação dos músculos inspiratórios. Nosso objetivo foi destacar as indicações e alguns aspectos da técnica cirúrgica empregada no implante laparoscópico dos eletrodos, assim como descrever cinco casos de pacientes tetraplégicos submetidos à técnica. MÉTODOS: A seleção dos pacientes envolveu estudos de condução do nervo frênico por via transcutânea para determinar se os nervos estavam preservados. A abordagem cirúrgica foi laparoscopia clássica, com quatro trocartes. A técnica foi iniciada com o mapeamento elétrico para encontrar os "pontos motores" (pontos de contração máxima do diafragma). Se o mapeamento era bem-sucedido, dois eletrodos eram implantados na face abdominal de cada lado do diafragma para estimular ramos do nervo frênico. RESULTADOS: Dos cinco pacientes, três e um, respectivamente, eram capazes de respirar somente com o uso do marca-passo por períodos superiores a 24 e 6 h, enquanto um não era capaz. CONCLUSÕES: Embora seja necessário um acompanhamento mais longo para chegar a conclusões definitivas, os resultados iniciais são promissores, pois, no momento, a maioria dos nossos pacientes pode permanecer sem ventilação mecânica por longos períodos de tempo.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: We sought to determine maternal and neonatal outcomes by labor onset type and gestational age. STUDY DESIGN: We used electronic medical records data from 10 US institutions in the Consortium on Safe Labor on 115,528 deliveries from 2002 through 2008. Deliveries were divided by labor onset type (spontaneous, elective induction, indicated induction, unlabored cesarean). Neonatal and maternal outcomes were calculated by labor onset type and gestational age. RESULTS: Neonatal intensive care unit admissions and sepsis improved with each week of gestational age until 39 weeks (P < .001). After adjusting for complications, elective induction of labor was associated with a lower risk of ventilator use (odds ratio [OR], 0.38; 95% confidence interval [CI], 0.28-0.53), sepsis (OR, 0.36; 95% CI, 0.26-0.49), and neonatal intensive care unit admissions (OR, 0.52; 95% CI, 0.48-0.57) compared to spontaneous labor. The relative risk of hysterectomy at term was 3.21 (95% CI, 1.08-9.54) with elective induction, 1.16 (95% CI, 0.24-5.58) with indicated induction, and 6.57 (95% CI, 1.78-24.30) with cesarean without labor compared to spontaneous labor. CONCLUSION: Some neonatal outcomes improved until 39 weeks. Babies born with elective induction are associated with better neonatal outcomes compared to spontaneous labor. Elective induction may be associated with an increased hysterectomy risk.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Decisions regarding whether to administer intensive care to extremely premature infants are often based on gestational age alone. However, other factors also affect the prognosis for these patients. METHODS: We prospectively studied a cohort of 4446 infants born at 22 to 25 weeks' gestation (determined on the basis of the best obstetrical estimate) in the Neonatal Research Network of the National Institute of Child Health and Human Development to relate risk factors assessable at or before birth to the likelihood of survival, survival without profound neurodevelopmental impairment, and survival without neurodevelopmental impairment at a corrected age of 18 to 22 months. RESULTS: Among study infants, 3702 (83%) received intensive care in the form of mechanical ventilation. Among the 4192 study infants (94%) for whom outcomes were determined at 18 to 22 months, 49% died, 61% died or had profound impairment, and 73% died or had impairment. In multivariable analyses of infants who received intensive care, exposure to antenatal corticosteroids, female sex, singleton birth, and higher birth weight (per each 100-g increment) were each associated with reductions in the risk of death and the risk of death or profound or any neurodevelopmental impairment; these reductions were similar to those associated with a 1-week increase in gestational age. At the same estimated likelihood of a favorable outcome, girls were less likely than boys to receive intensive care. The outcomes for infants who underwent ventilation were better predicted with the use of the above factors than with use of gestational age alone. CONCLUSIONS: The likelihood of a favorable outcome with intensive care can be better estimated by consideration of four factors in addition to gestational age: sex, exposure or nonexposure to antenatal corticosteroids, whether single or multiple birth, and birth weight. (ClinicalTrials.gov numbers, NCT00063063 [ClinicalTrials.gov] and NCT00009633 [ClinicalTrials.gov].).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Apesar da utilização da ventilação mecânica protetora como estratégia para o tratamento da síndrome do desconforto respiratório agudo, ao menos um quarto dos pacientes com essa síndrome ainda apresentam redução na função pulmonar após 6 meses de seguimento. Não se sabe se esta redução está relacionada com a gravidade da síndrome ou associada com a forma de ventilar o paciente. Nosso objetivo neste trabalho foi avaliar a associação entre alterações funcionais e estruturais do pulmão com parâmetros de gravidade clínica e de ventilação mecânica. Foi realizada uma análise secundária dos dados obtidos em estudo randomizado e controlado que incluiu pacientes com síndrome do desconforto respiratório agudo moderada/grave, internados em seis unidades de terapia intensiva em um hospital terciário da cidade de São Paulo. Foram analisados dados de pacientes que tinham ao menos um teste de função pulmonar no seguimento. O teste funcional incluiu a medida da capacidade vital forçada, volumes pulmonares e a capacidade de difusão do monóxido de carbono após 1, 2 e 6 meses de seguimento. Foram considerados variáveis independentes o volume corrente, a pressão de distensão e a pressão positiva ao final da expiração (todos medidos após 24 horas da randomização) e um sistema de classificação de prognóstico (APACHE II), a relação PaO2/FIO2 e a complacência respiratória estática (todos medidos antes da randomização). Também foi realizada tomografia de alta resolução do tórax juntamente com os testes de função pulmonar, e posterior análise quantitativa das imagens. Na avaliação de 6 meses também foi realizado teste de caminhada de 6 minutos e um questionário de qualidade de vida (SF-36). Um total de 21 pacientes realizaram o teste de função pulmonar após 1 mês e 15 pacientes realizaram após 2 e 6 meses de seguimento. A capacidade vital forçada foi relacionada inversamente com a pressão de distensão na avaliação de 1, 2 e 6 meses (p < 0,01). A capacidade de difusão do monóxido de carbono relacionou-se inversamente com a pressão de distensão e com o APACHE II (ambos p < 0,01) na avaliação de 1 e 2 meses. Após 6 meses de seguimento, houve correlação inversa entre a pressão de distensão e a capacidade vital forçada independente do volume corrente, da pressão de platô e da complacência estática respiratória após ajustes (R2 = 0,51, p = 0,02). A pressão de distensão também se relacionou com o volume pulmonar total, a densidade pulmonar media e a porcentagem de volume pulmonar não aerado ou pobremente aerado medidos através da análise quantitativa da tomografia computadorizada de tórax realizada na avaliação de 6 meses. Também foi observada relação entre a qualidade de vida após 6 meses de seguimento e a pressão de distensão considerando o domínio estado geral de saúde. Nós concluímos que mesmo em pacientes ventilados com reduzido volume corrente e pressão de platô limitada, maiores valores de pressão de distensão relacionaram-se com menores valores de função pulmonar no seguimento de longo prazo

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background and objective: There are no data about the influence of anaesthetics on cardiovascular variables during pressure support ventilation of the lungs through the laryngeal mask airway. We compared propofol, sevoflurane and isoflurane for maintenance of anaesthesia with the ProSeal (R) laryngeal mask airway during pressure support ventilation. Methods: Sixty healthy adults undergoing peripheral musculo-skeletal surgery were randomized for maintenance with sevoflurane end-tidal 29%, isoflurane end-tidal 1.1% or propofol 6 mg kg(-1) h(-1) in oxygen 33% and air. Pressure support ventilation comprised positive end-expiratory pressure set at 5 cmH(2)O, and pressure support set 5 cmH(2)O above positive end-expiratory pressure. Pressure support was initiated when inspiration produced a 2 cmH(2)O reduction in airway pressure. A blinded observer recorded cardiorespiratory variables (heart rate, mean blood pressure, oxygen saturation, air-way occlusion pressure, respiratory rate, expired tidal volume, expired minute volume and end-tidal CO2), adverse events and emergence times. Results: Respiratory rate and minute volume were 10-21% lower, and end-tidal CO2 6-11% higher with the propofol group compared with the sevoflurane or isoflurane groups, but otherwise cardiorespiratory variables were similar among groups. No adverse events occurred in any group. Emergence times were longer with the propofol group compared with the sevoflurane or isoflurane groups (10 vs. 7 vs. 7 min). Conclusion: Lung ventilation is less effective and emergence times are longer with propofol than sevoflurane or isoflurane for maintenance of anaesthesia during pressure support ventilation with the ProSeal (R) laryngeal mask airway. However, these differences are small and of doubtful clinical importance.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: Given the inaccessibility of indirect calorimetry, intensive care units generally use predictive equations or recommendations that are established by international societies to determine energy expenditure. The aim of the present study was to compare the energy expenditure of critically ill patients, as determined using indirect calorimetry, to the values obtained using the Harris-Benedict equation. Methods: A retrospective observational study was conducted at the Intensive Care Unit 1 of the Centro Hospitalar do Porto. The energy requirements of hospitalized critically ill patients as determined using indirect calorimetry were assessed between January 2003 and April 2012. The accuracy (± 10% difference between the measured and estimated values), the mean differences and the limits of agreement were determined for the studied equations. Results: Eighty-five patients were assessed using 288 indirect calorimetry measurements. The following energy requirement values were obtained for the different methods: 1,753.98±391.13 kcal/ day (24.48 ± 5.95 kcal/kg/day) for indirect calorimetry and 1,504.11 ± 266.99 kcal/day (20.72±2.43 kcal/kg/day) for the HarrisBenedict equation. The equation had a precision of 31.76% with a mean difference of -259.86 kcal/day and limits of agreement between -858.84 and 339.12 kcal/day. Sex (p=0.023), temperature (p=0.009) and body mass index (p< 0.001) were found to significantly affect energy expenditure Conclusion: The Harris-Benedict equation is inaccurate and tends to underestimate energy expenditure. In addition, the Harris-Benedict equation is associated with significant differences between the predicted and true energy expenditure at an individual level

Relevância:

40.00% 40.00%

Publicador:

Resumo:

"Translation of an article ... in the Russian-language journal vestnik khirurgii (Herald of surgery), vol. 90, no. 3, March 1963, pages 81-87."

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Euphausiids constitute major biomass component in shelf ecosystems and play a fundamental role in the rapid vertical transport of carbon from the ocean surface to the deeper layers during their daily vertical migration (DVM). DVM depth and migration patterns depend on oceanographic conditions with respect to temperature, light and oxygen availability at depth, factors that are highly dependent on season in most marine regions. Changes in the abiotic conditions also shape Euphausiid metabolism including aerobic and anaerobic energy production. Here we introduce a global krill respiration model which includes the effect of latitude (LAT), the day of the year of interest (DoY), and the number of daylight hours on the day of interest (DLh), in addition to the basal variables that determine ectothermal oxygen consumption (temperature, body mass and depth) in the ANN model (Artificial Neural Networks). The newly implemented parameters link space and time in terms of season and photoperiod to krill respiration. The ANN model showed a better fit (r**2=0.780) when DLh and LAT were included, indicating a decrease in respiration with increasing LAT and decreasing DLh. We therefore propose DLh as a potential variable to consider when building physiological models for both hemispheres. We also tested for seasonality the standard respiration rate of the most common species that were investigated until now in a large range of DLh and DoY with Multiple Linear Regression (MLR) or General Additive model (GAM). GAM successfully integrated DLh (r**2= 0.563) and DoY (r**2= 0.572) effects on respiration rates of the Antarctic krill, Euphausia superba, yielding the minimum metabolic activity in mid-June and the maximum at the end of December. Neither the MLR nor the GAM approach worked for the North Pacific krill Euphausia pacifica, and MLR for the North Atlantic krill Meganyctiphanes norvegica remained inconclusive because of insufficient seasonal data coverage. We strongly encourage comparative respiration measurements of worldwide Euphausiid key species at different seasons to improve accuracy in ecosystem modelling.