951 resultados para Reproducibility
Resumo:
Ethnographic film is often associated with many European countries’ past as colonial powers and the way these countries used film to depict African, American and Asian territories and populations they once ruled. However, ethnographic film also has a European tradition of its own, closely interlaced with the history of ethnography and anthropology as autonomous sciences and with the desire of scholars to represent local, regional and national cultural identities. This paper presents a Portuguese attempt of this sort dating from 1938, when the authoritarian regime organized a national contest to determine which would be Portugal’s most “authentic” village – something other European countries also did. As part of this metonymic contribution to the construction of Portugal’s national identity as an agrarian utopia, a short documentary was shot, sponsored by the same official propaganda office that had organized the contest. In this film, the viewer’s gaze is made to coincide with the one of the national jury visiting the final selection of 12 villages and to whose benefit local scholars had organized all sorts of colourful peasant traditions hoping to cause the strongest impression. The film makes a strong case for the importance of ethnographic film as a relevant instance not only of the iteration of existing European national cultures, but also of the construction of so many of Europe’s national identities and traditions. Suffice to say that even today the village of “Monsanto”, which won the 1938 contest, is still referred to as “Portugal’s most Portuguese village”.
Resumo:
This paper deals with the analysis of 10 batches of L.major-like and L.(V.) braziliensis antigens added or not of a proteases inhibitor evaluated by means of an IgG-ELISA on three consecutive days using positive standard sera from patients with diagnosis of American Leishmaniasis previously tested for the presence of IgG antibodies by means of ELISA. The statistical analysis showed that for L. (V.) braziliensis the PMSF-containing antigen did not show any difference among batches or days of testing; the L.(V.) braziliensis antigen without PMSF showed statistical significance for differences among batches and a two-way ANOVA showed significant differences between antigens. L.major-like antigen prepared with or without PMSF showed differences among batches; all 3 days of testing displayed differences for the PMSF antigen but only for days 1 and 2 for the antigen without inhibitor. A two-way ANOVA showed differences among batches of the antigens but not for antigens with and without the protein inhibitor. According to the statistical analysis the L.major-like antigen added or not of PMSF has shown that it is the choice antigen for mucocutaneous leishmaniasis serology.
Resumo:
Biofilm research is growing more diverse and dependent on high-throughput technologies and the large-scale production of results aggravates data substantiation. In particular, it is often the case that experimental protocols are adapted to meet the needs of a particular laboratory and no statistical validation of the modified method is provided. This paper discusses the impact of intra-laboratory adaptation and non-rigorous documentation of experimental protocols on biofilm data interchange and validation. The case study is a non-standard, but widely used, workflow for Pseudomonas aeruginosa biofilm development, considering three analysis assays: the crystal violet (CV) assay for biomass quantification, the XTT assay for respiratory activity assessment, and the colony forming units (CFU) assay for determination of cell viability. The ruggedness of the protocol was assessed by introducing small changes in the biofilm growth conditions, which simulate minor protocol adaptations and non-rigorous protocol documentation. Results show that even minor variations in the biofilm growth conditions may affect the results considerably, and that the biofilm analysis assays lack repeatability. Intra-laboratory validation of non-standard protocols is found critical to ensure data quality and enable the comparison of results within and among laboratories.
Resumo:
Background: Echocardiography, though non-invasive and having relatively low-cost, presents issues of variability which can limit its use in epidemiological studies. Objective: To evaluate left ventricular mass reproducibility when assessed at acquisition (online) compared to when assessed at a reading center after electronic transmission (offline) and also when assessed by different readers at the reading center. Methods: Echocardiographers from the 6 ELSA-Brasil study investigation centers measured the left ventricular mass online during the acquisition from 124 studies before transmitting to the reading center, where studies were read according to the study protocol. Half of these studies were blindly read by a second reader in the reading center. Results: From the 124 echocardiograms, 5 (4%) were considered not measurable. Among the remaining 119, 72 (61%) were women, mean age was 50.2 ± 7.0 years and 2 had structural myocardial abnormalities. Images were considered to be optimal/ good by the reading center for 110 (92.4%) cases. No significant difference existed between online and offline measurements (1,29 g, CI 95% −3.60-6.19), and the intraclass correlation coefficient between them was 0.79 (CI 95% 0.71-0.85). For images read by two readers, the intraclass correlation coefficient was 0.86 (CI 95% 0.78-0.91). Conclusion: There were no significant drifts between online and offline left ventricular mass measurements, and reproducibility was similar to that described in previous studies. Central quantitative assessment of echocardiographic studies in reading centers, as performed in the ELSA-Brasil study, is feasible and useful in clinical and epidemiological studies performed in our setting.
Resumo:
Abstract Background: Studies have shown the impact of atrial fibrillation (AF) on the patients' quality of life. Specific questionnaires enable the evaluation of relevant events. We previously developed a questionnaire to assess the quality of life of patients with AF (AFQLQ version 1), which was reviewed in this study, and new domains were added. Objective: To demonstrate the reproducibility of the AFQLQ version 2 (AFQLQ v.2), which included the domains of fatigue, illness perception and well-being. Methods: We applied 160 questionnaires (AFQLQ v.2 and SF-36) to 40 patients, at baseline and 15 days after, to measure inter- and intraobserver reproducibility. The analysis of quality of life stability was determined by test-retest, applying the Bartko intraclass correlation coefficient (ICC). Internal consistency was assessed by Cronbach's alpha test. Results: The total score of the test-retest (n = 40) had an ICC of 0.98 in the AFQLQ v.2, and of 0.94 in the SF36. In assessing the intra- and interobserver reproducibility of the AFQLQ v.2, the ICC reliability was 0.98 and 0.97, respectively. The internal consistency had a Cronbach's alpha coefficient of 0.82, compatible with good agreement of the AFQLQ v.2. Conclusion: The AFQLQ v.2 performed better than its previous version. Similarly, the domains added contributed to make it more comprehensive and robust to assess the quality of life of patients with AF.
Resumo:
OBJECTIVE: Contemporary free-breathing non contrast enhanced cardiovascular magnetic resonance angiography (CMRA) was qualitatively and quantitatively evaluated to ascertain the reproducibility of the method for coronary artery luminal dimension measurements. SUBJECTS AND METHODS: Twenty-two healthy volunteers (mean age 32 +/- 7 years, 12 males) without coronary artery disease were imaged at 2 centers (1 each in Europe and North America) using navigator-gated and corrected SSFP CMRA on a commercial whole body 1.5T System. Repeat images of right (RCA, n = 21), left anterior descending (LAD, n = 14) and left circumflex (LCX, n = 14) coronary arteries were obtained in separate sessions using identical scan protocol and imaging parameters. True visible vessel length, signal-to-noise (SNR), contrast-to-noise ratios (CNR) and the average luminal diameter over the first 4 cm of the vessel were measured. Intra-observer, inter-observer and inter-scan reproducibility of coronary artery luminal diameter were determined using Pearson's correlation, Bland-Altman analysis and intraclass correlation coefficients (ICC). RESULTS: CNR, SNR and the mean length of the RCA, LAD and LCX imaged for original and repeat scans were not significantly different (all p > 0.30). There was a high degree of intra-observer, inter-observer and inter-scan agreements for RCA, LAD and LCX luminal diameter respectively on Bland-Altman and ICC analysis (ICC's for RCA: 0.98. 0.98 and 0.86; LAD: 0.89, 0.89 and 0.63; LCX: 0.95, 0.94 and 0.79). CONCLUSION: In a 2-center study, we demonstrate that free-breathing 3D SSFP CMRA can visualize long continuous segments of coronary vessels with highly reproducible measurements of luminal diameter.
Resumo:
To assess the variability of the response to exogenous atrial natriuretic peptide (ANP), it was infused at the rate of 1 microgram/min for 2 h in 6 salt-loaded normal volunteers under controlled conditions on 2 occasions at an interval of 1 week. The effect on solute excretion and the haemodynamic and endocrine actions were highly reproducible. The constant ANP infusion caused a delayed and prolonged excretion of sodium, chloride and calcium, no change in potassium or phosphate excretion or in glomerular filtration rate but a marked decrease in renal plasma flow. Blood pressure, heart rate and the plasma levels of angiotensin II, aldosterone, arginine vasopressin and plasma renin activity were unaltered. The effect of a 2-h infusion of ANP 0.5 microgram/min or its vehicle on apparent hepatic blood flow (HBF) was also studied in 14 normal volunteers by measuring the indocyanine green clearance. A 21% decrease in HBF was observed in subjects who received the ANP infusion (p less than 0.01 vs vehicle). Thus, ANP infused at a dose that did not lower blood pressure decreased both renal and liver blood flow in normotensive volunteers. The renal and endocrine responses to ANP were reproducible over a 1-week interval.
Resumo:
Objective: To assess reproducibility and feasibility of amusculoskeletal ultrasound (US) score for rheumatoid arthritis amongrheumatologist with diverse expertise in US, working in private orhospital practice.Methods: The Swiss Sonography in Arthritis and Rheumatism(SONAR) group has developed a semi-quantitative score for RA usingOMERACT criteria for synovitis and erosion. The score was taught torheumatologists trained in US through two workshops. Subsequently,they were encouraged to practice in their office. For the study, we used6 US machines of different quality, each with a different patient.19 readers randomly selected among rheumatologists who haveattended both workshops, were asked to score anonymously at leastone patient. To assess whether some factors influence the score, weasked each reader to answer questionnaire describing his experiencewith US.Results: 19 rheumatologists have performed 29 scans, each patienthaving been evaluated by 4 to 6 readers. Median time for examcompletion was 20 minutes (range 15 to 60 mn). 53% ofrheumatologists work in private practice. Graph 1 show the global greyscale score for each patient. Weighted kappa was calculated for eachpair of reader using stata11. Almost all kappa of poor agreement wereobtained with a low quality device or by an assessor who havepreviously performed less than 5 scores himself.Conclusions: This is the first study to show an US score for RAfeasible by rheumatologists with diverse expertise in US both in privateand hospital practice. Reproducibility seemed to be influenced by thequality of device and previous experience with the score.
Resumo:
BACKGROUND: The aim of this study was to assess, at the European level and using digital technology, the inter-pathologist reproducibility of the ISHLT 2004 system and to compare it with the 1990 system We also assessed the reproducibility of the morphologic criteria for diagnosis of antibody-mediated rejection detailed in the 2004 grading system. METHODS: The hematoxylin-eosin-stained sections of 20 sets of endomyocardial biopsies were pre-selected and graded by two pathologists (A.A. and M.B.) and digitized using a telepathology digital pathology system (Aperio ImageScope System; for details refer to http://aperio.com/). Their diagnoses were considered the index diagnoses, which covered all grades of acute cellular rejection (ACR), early ischemic lesions, Quilty lesions, late ischemic lesions and (in the 2005 system) antibody-mediated rejection (AMR). Eighteen pathologists from 16 heart transplant centers in 7 European countries participated in the study. Inter-observer reproducibility was assessed using Fleiss's kappa and Krippendorff's alpha statistics. RESULTS: The combined kappa value of all grades diagnosed by all 18 pathologists was 0.31 for the 1990 grading system and 0.39 for the 2005 grading system, with alpha statistics at 0.57 and 0.55, respectively. Kappa values by grade for 1990/2005, respectively, were: 0 = 0.52/0.51; 1A/1R = 0.24/0.36; 1B = 0.15; 2 = 0.13; 3A/2R = 0.29/0.29; 3B/3R = 0.13/0.23; and 4 = 0.18. For the 2 cases of AMR, 6 of 18 pathologists correctly suspected AMR on the hematoxylin-eosin slides, whereas, in each of 17 of the 18 AMR-negative cases a small percentage of pathologists (range 5% to 33%) overinterpreted the findings as suggestive for AMR. CONCLUSIONS: Reproducibility studies of cardiac biopsies by pathologists in different centers at the international level were feasible using digitized slides rather than conventional histology glass slides. There was a small improvement in interobserver agreement between pathologists of different European centers when moving from the 1990 ISHLT classification to the "new" 2005 ISHLT classification. Morphologic suspicion of AMR in the 2004 system on hematoxylin-eosin-stained slides only was poor, highlighting the need for better standardization of morphologic criteria for AMR. Ongoing educational programs are needed to ensure standardization of diagnosis of both acute cellular and antibody-mediated rejection.
Resumo:
BACKGROUND AND AIMS: little is known regarding the reproducibility of body fat measuring devices; hence, we assessed the between and within-device reproducibility, and the within-day variability of body fat measurements. METHODS: body fat percentage was measured twice on seventeen female students aged between 18 and 20 with a body mass index of 21.9 ± 2.5 kg/m2 (mean ± SD) using seven bipolar bioelectrical impedance devices. Each participant was also measured each hour between 7:00 and 22:00. RESULTS: the correlation between first and second measurements was very high (Spearman r between 0.985 and 1.000, p<0.001), as well as between devices (Spearman r between 0.916 and 0.991, p<0.001). Repeated measurements analysis showed no differences were between devices (p=0.59) or readings (first vs. second: p=0.74). Conversely, significant differences were found between assessment periods throughout the day, measurements made in the morning being lower than those made in the afternoon (F test for repeated values= 6.58, p<0.001). CONCLUSIONS: the between and within-device reproducibility for measuring body fat is high, enabling the use of multiple devices in a single study. Conversely, small but significant changes in body fat measurements occur during the day, urging body fat measurements to be performed at fixed times.
Resumo:
Laser desorption ionisation mass spectrometry (LDI-MS) has demonstrated to be an excellent analytical method for the forensic analysis of inks on a questioned document. The ink can be analysed directly on its substrate (paper) and hence offers a fast method of analysis as sample preparation is kept to a minimum and more importantly, damage to the document is minimised. LDI-MS has also previously been reported to provide a high power of discrimination in the statistical comparison of ink samples and has the potential to be introduced as part of routine ink analysis. This paper looks into the methodology further and evaluates statistically the reproducibility and the influence of paper on black gel pen ink LDI-MS spectra; by comparing spectra of three different black gel pen inks on three different paper substrates. Although generally minimal, the influences of sample homogeneity and paper type were found to be sample dependent. This should be taken into account to avoid the risk of false differentiation of black gel pen ink samples. Other statistical approaches such as principal component analysis (PCA) proved to be a good alternative to correlation coefficients for the comparison of whole mass spectra.
Resumo:
OBJECTIVE: The principal aim of this study was to develop a Swiss Food Frequency Questionnaire (FFQ) for the elderly population for use in a study to investigate the influence of nutritional factors on bone health. The secondary aim was to assess its validity and both short-term and long-term reproducibility. DESIGN: A 4-day weighed record (4 d WR) was applied to 51 randomly selected women of a mean age of 80.3 years. Subsequently, a detailed FFQ was developed, cross-validated against a further 44 4-d WR, and the short- (1 month, n = 15) and long-term (12 months, n = 14) reproducibility examined. SETTING: French speaking part of Switzerland. SUBJECTS: The subjects were randomly selected women recruited from the Swiss Evaluation of the Methods of Measurement of Osteoporotic Fracture cohort study. RESULTS: Mean energy intakes by 4-d WR and FFQ showed no significant difference [1564.9 kcal (SD 351.1); 1641.3 kcal (SD 523.2) respectively]. Mean crude nutrient intakes were also similar (with nonsignifcant P-values examining the differences in intake) and ranged from 0.13 (potassium) to 0.48 (magnesium). Similar results were found in the reproducibility studies. CONCLUSION: These findings provide evidence that this FFQ adequately estimates nutrient intakes and can be used to rank individuals within distributions of intake in specific populations.
Resumo:
BACKGROUND: Straylight gives the appearance of a veil of light thrown over a person's retinal image when there is a strong light source present. We examined the reproducibility of the measurements by C-Quant, and assessed its correlation to characteristics of the eye and subjects' age. PARTICIPANTS AND METHODS: Five repeated straylight measurements were taken using the dominant eye of 45 healthy subjects (age 21-59) with a BCVA of 20/20: 14 emmetropic, 16 myopic, eight hyperopic and seven with astigmatism. We assessed the extent of reproducibility of straylight measures using the intraclass correlation coefficient. RESULTS: The mean straylight value of all measurements was 1.01 (SD 0.23, median 0.97, interquartile range 0.85-1.1). Per 10 years of age, straylight increased in average by 0.10 (95%CI 0.04 to 0.16, p < 0.01]. We found no independent association of refraction (range -5.25 dpt to +2 dpt) on straylight values (0.001; 95%CI -0.022 to 0.024, p = 0.92). Compared to emmetropic subjects, myopia reduced straylight (-.011; -0.024 to 0.02, p = 0.11), whereas higher straylight values (0.09; -0.01 to 0.20, p = 0.09) were observed in subjects with blue irises as compared to dark-colored irises when correcting for age. The intraclass correlation coefficient (ICC) of repeated measurements was 0.83 (95%CI 0.76 to 0.90). CONCLUSIONS: Our study showed that straylight measurements with the C-Quant had a high reproducibility, i.e. a lack of large intra-observer variability, making it appropriate to be applied in long-term follow-up studies assessing the long-term effect of surgical procedures on the quality of vision.