917 resultados para Remote monitoring systems


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper summarizes the experience and the lessons learned from the European project PERFORM (A sophisticated multi-parametric system FOR the continuous effective assessment and monitoring of motor status in Parkinson s disease and other neurodegenerative diseases). PERFORM is aimed to provide a telehealth system for the remote monitoring of Parkinson s disease patients (PD) at their homes. This paper explains the global experience with PERFORM. It summarizes the technical performance of the system and the feedback received from the patients in terms of usability and wearability.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"March 1990."

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Prepared under contract no. HSM 110-70-406.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Includes bibliographical references (p. 27-30).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper investigates the input-output characteristics of structural health monitoring systems for composite plates based on permanently attached piezoelectric transmitter and sensor elements. Using dynamic piezoelectricity theory and a multiple integral transform method to describe the propagating and scattered flexural waves an electro-mechanical model for simulating the voltage input-output transfer function for circular piezoelectric transmitters and sensors adhesively attached to an orthotropic composite plate is developed. The method enables the characterization of all three physical processes, i.e. wave generation, wave propagation and wave reception. The influence of transducer, plate and attached electrical circuit characteristics on the voltage output behaviour of the system is examined through numerical calculations, both in frequency and the time domain. The results show that the input-output behaviour of the system is not properly predicted by the transducers' properties alone. Coupling effects between the transducers and the tested structure have to be taken into account, and adding backing materials to the piezoelectric elements can significantly improve the sensitivity of the system. It is shown that in order to achieve maximum sensitivity, particular piezoelectric transmitters and sensors need to be designed according to the structure to be monitored and the specific frequency regime of interest.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: Although manufacturers of bicycle power monitoring devices SRM and Power Tap (PT) claim accuracy to within 2.5%, there are limited scientific data available in support. The purpose of this investigation was to assess the accuracy of SRM and PT under different conditions. Methods: First, 19 SRM were calibrated, raced for 11 months, and retested using a dynamic CALRIG (50-1000 W at 100 rpm). Second, using the same procedure, five PT were repeat tested on alternate days. Third, the most accurate SRM and PT were tested for the influence of cadence (60, 80, 100, 120 rpm), temperature (8 and 21degreesC) and time (1 h at similar to300 W) on accuracy. Finally, the same SRM and PT were downloaded and compared after random cadence and gear surges using the CALRIG and on a training ride. Results: The mean error scores for SRM and PT factory calibration over a range of 50-1000 W were 2.3 +/- 4.9% and -2.5 +/- 0.5%, respectively. A second set of trials provided stable results for 15 calibrated SRM after 11 months (-0.8 +/- 1.7%), and follow-up testing of all PT units confirmed these findings (-2.7 +/- 0.1%). Accuracy for SRM and PT was not largely influenced by time and cadence; however. power output readings were noticeably influenced by temperature (5.2% for SRM and 8.4% for PT). During field trials, SRM average and max power were 4.8% and 7.3% lower, respectively, compared with PT. Conclusions: When operated according to manufacturers instructions, both SRM and PT offer the coach, athlete, and sport scientist the ability to accurately monitor power output in the lab and the field. Calibration procedures matching performance tests (duration, power, cadence, and temperature) are, however, advised as the error associated with each unit may vary.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper highlights the challenges of satellite monitoring systems integration, in particular based on Grid platform, and reviews possible solutions for these problems. We describe integration issues on different levels: data integration level and task management level (job submission in terms of Grid). We show example of described technologies for integration of monitoring systems of Ukraine (National Space Agency of Ukraine, NASU) and Russia (Space Research Institute RAS, IKI RAN). Another example refers to the development of InterGrid infrastructure that integrates several regional and national Grid systems: Ukrainian Academician Grid (with Satellite data processing Grid segment) and RSGS Grid (Chinese Academy of Sciences).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In view of the increasingly complexity of services logic and functional requirements, a new system architecture based on SOA was proposed for the equipment remote monitoring and diagnosis system. According to the design principles of SOA, different levels and different granularities of services logic and functional requirements for remote monitoring and diagnosis system were divided, and a loosely coupled web services system was built. The design and implementation schedule of core function modules for the proposed architecture were presented. A demo system was used to validate the feasibility of the proposed architecture.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS: Device-based remote monitoring (RM) has been linked to improved clinical outcomes at short to medium-term follow-up. Whether this benefit extends to long-term follow-up is unknown. We sought to assess the effect of device-based RM on long-term clinical outcomes in recipients of implantable cardioverter-defibrillators (ICD). METHODS: We performed a retrospective cohort study of consecutive patients who underwent ICD implantation for primary prevention. RM was initiated with patient consent according to availability of RM hardware at implantation. Patients with concomitant cardiac resynchronization therapy were excluded. Data on hospitalizations, mortality and cause of death were systematically assessed using a nationwide healthcare platform. A Cox proportional hazards model was employed to estimate the effect of RM on mortality and a composite endpoint of cardiovascular mortality and hospital admission due to heart failure (HF). RESULTS: 312 patients were included with a median follow-up of 37.7months (range 1 to 146). 121 patients (38.2%) were under RM since the first outpatient visit post-ICD and 191 were in conventional follow-up. No differences were found regarding age, left ventricular ejection fraction, heart failure etiology or NYHA class at implantation. Patients under RM had higher long-term survival (hazard ratio [HR] 0.50, CI 0.27-0.93, p=0.029) and lower incidence of the composite outcome (HR 0.47, CI 0.27-0.82, p=0.008). After multivariate survival analysis, overall survival was independently associated with younger age, higher LVEF, NYHA class lower than 3 and RM. CONCLUSION: RM was independently associated with increased long-term survival and a lower incidence of a composite endpoint of hospitalization for HF or cardiovascular mortality.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The thesis has been carried out within the “SHAPE Project - Predicting Strength Changes in Bridges from Frequency Data Safety, Hazard, and Poly-harmonic Evaluation” (ERA-NET Plus Infravation Call 2014) which dealt with the structural assessment of existing bridges and laboratory structural reproductions through the use of vibration-based monitoring systems, for detecting changes in their natural frequencies and correlating them with the occurrence of damage. The main purpose of this PhD dissertation has been the detection of the variation of the main natural frequencies as a consequence of a previous-established damage configuration provided on a structure. Firstly, the effect of local damage on the modal feature has been discussed mainly concerning a steel frame and a composite steel-concrete bridge. Concerning the variation of the fundamental frequency of the small bridge, the increasing severity of two local damages has been investigated. Moreover, the comparison with a 3D FE model is even presented establishing a link between the dynamic properties and the damage features. Then, moving towards a diffused damage pattern, four concrete beams and a small concrete deck were loaded achieving the yielding of the steel reinforcement. The stiffness deterioration in terms of frequency shifts has been reconsidered by collecting a large set of dynamic experiments on simply supported R.C. beams discussed in the literature. The comparison of the load-frequency curves suggested a significant agreement among all the experiments. Thus, in the framework of damage mechanics, the “breathing cracks” phenomenon has been discussed leading to an analytical formula able to explain the frequency decay observed experimentally. Lastly, some dynamic investigations of two existing bridges and the corresponding FE Models are presented in Chapter 4. Moreover, concerning the bridge in Bologna, two prototypes of a network of accelerometers were installed and the data of a few months of monitoring have been discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Com a generalização das tecnologias de informação e comunicação na área da saúde, a monitorização remota de pacientes, a partir de dispositivos móveis, é uma realidade que contribui para uma melhor qualidade de vida dos pacientes. Mas, não são só os pacientes que ganham com a introdução destas tecnologias, também os profissionais de saúde e os hospitais retiram as suas vantagens. Os profissionais de saúde são munidos de uma ferramenta móvel de monitorização permanente de sinais vitais, aumentando desta forma a ligação médico-paciente. Relativamente aos hospitais, estes vêem os custos de manutenção reduzirem, em virtude da possibilidade dos pacientes puderem ser monitorizados a partir dos seus lares. Neste projecto pretende-se identificar mecanismos que possibilitem responder de forma eficaz à necessidade de partilha de informação, nomeadamente protocolos de comunicação, segurança e sistemas de integração. Foi projectado um protótipo, constituído por um middleware e uma aplicação cliente móvel, onde o middleware tem como missão garantir a interoperabilidade entre um servidor HL7 e a aplicação cliente, utilizada pelo profissional de saúde. A normalização da informação médica trocada entre o servidor HL7 e o middleware obedece à norma internacional HL7.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In 1903, more than 30 million m3 of rock fell from the east slopes of Turtle Mountain in Alberta, Canada, causing a rock avalanche that killed about 70 people in the town of Frank. The Alberta Government, in response to continuing instabilities at the crest of the mountain, established a sophisticated field laboratory where state-of-the-art monitoring techniques have been installed and tested as part of an early-warning system. In this chapter, we provide an overview of the causes, trigger, and extreme mobility of the landslide. We then present new data relevant to the characterization and detection of the present-day instabilities on Turtle Mountain. Fourteen potential instabilities have been identified through field mapping and remote sensing. Lastly, we provide a detailed review of the different in-situ and remote monitoring systems that have been installed on the mountain. The implications of the new data for the future stability of Turtle Mountain and related landslide runout, and for monitoring strategies and risk management, are discussed.