992 resultados para Reference measurements
Resumo:
The study of the atmospheric chemical composition is crucial to understand the climate changes that we are experiencing in the last decades and to monitor the air quality over industrialized areas. The Multi-AXis Differential Optical Absorption Spectroscopy (MAX-DOAS) ground-based instruments are particularly suitable to derive the concentration of some trace gases that absorb the Visible (VIS) and Ultra-Violet (UV) solar radiation. The zenith-sky spectra acquired by the Gas Analyzer Spectrometer Correlating Optical Differences / New Generation 4 (GASCOD/NG4) instrument are exploited to retrieve the NO2 and O3 total Vertical Column Densities (VCDs) over Lecce. The results show that the NO2 total VCDs are significantly affected by the tropospheric content, consequence of the anthropogenic activity. Indeed, they present systematically lower values during Sunday, when less traffic is generally present around the measurement site, and during windy days, especially when the wind direction measured at 2 m height is not from the city of Lecce. Another MAX-DOAS instrument (SkySpec-2D) is exploited to create the first Italian MAX-DOAS site compliant to the Fiducial Reference Measurements for DOAS (FRM4DOAS) standards, in San Pietro Capofiume (SPC), located in the middle of the Po Valley. After the assessment of the SkySpec-2D’s performances through two measurement campaigns taken place in Bologna and in Rome, SkySpec-2D is installed in SPC on the 1st October 2021. Its MAX-DOAS spectra are used to retrieve the NO2 and O3 total VCDs, and aerosol extinction and NO2 tropospheric vertical profiles over the Po Valley exploiting the Bremen Optimal estimation REtrieval for Aerosol and trace gaseS (BOREAS) algorithm. Promising results are found, with high correlations against both in-situ and satellite data. In the future, these data will play an important role for air quality studies over the Po Valley and for satellite validation purposes.
Resumo:
No literature data above atmospheric pressure could be found for the viscosity of TOTIVI. As a consequence, the present viscosity results could only be compared upon extrapolation of the vibrating wire data to 0.1 MPa. Independent viscosity measurements were performed, at atmospheric pressure, using an Ubbelohde capillary in order to compare with the vibrating wire results, extrapolated by means of the above mentioned correlation. The two data sets agree within +/- 1%, which is commensurate with the mutual uncertainty of the experimental methods. Comparisons of the literature data obtained at atmospheric pressure with the present extrapolated vibrating-wire viscosity measurements have shown an agreement within +/- 2% for temperatures up to 339 K and within +/- 3.3% for temperatures up to 368 K. (C) 2014 Elsevier B.V. All rights reserved.
Resumo:
In Part I of the present work we describe the viscosity measurements performed on tris(2-ethylhexyl) trimellitate or 1,2,4-benzenetricarboxylic acid, tris(2-ethylhexyl) ester (TOTM) up to 65 MPa and at six temperatures from (303 to 373)K, using a new vibrating-wire instrument. The main aim is to contribute to the proposal of that liquid as a potential reference fluid for high viscosity, high pressure and high temperature. The present Part II is dedicated to report the density measurements of TOTM necessary, not only to compute the viscosity data presented in Part I, but also as complementary data for the mentioned proposal. The present density measurements were obtained using a vibrating U-tube densimeter, model DMA HP, using model DMA5000 as a reading unit, both instruments from Anton Paar GmbH. The measurements were performed along five isotherms from (293 to 373)K and at eleven different pressures up to 68 MPa. As far as the authors are aware, the viscosity and density results are the first, above atmospheric pressure, to be published for TOTM. Due to TOTM's high viscosity, its density data were corrected for the viscosity effect on the U-tube density measurements. This effect was estimated using two Newtonian viscosity standard liquids, 20 AW and 200 GW. The density data were correlated with temperature and pressure using a modified Tait equation. The expanded uncertainty of the present density results is estimated as +/- 0.2% at a 95% confidence level. Those results were correlated with temperature and pressure by a modified Tait equation, with deviations within +/- 0.25%. Furthermore, the isothermal compressibility, K-T, and the isobaric thermal expansivity, alpha(p), were obtained by derivation of the modified Tait equation used for correlating the density data. The corresponding uncertainties, at a 95% confidence level, are estimated to be less than +/- 1.5% and +/- 1.2%, respectively. No isobaric thermal expansivity and isothermal compressibility for TOTM were found in the literature. (C) 2014 Elsevier B.V. All rights reserved.
Resumo:
Department of Physics, Cochin University of Science and Technology
Resumo:
A collection of 24 seawaters from various worldwide locations and differing depth was culled to measure their chlorine isotopic composition (delta(37)Cl). These samples cover all the oceans and large seas: Atlantic, Pacific, Indian and Antarctic oceans, Mediterranean and Red seas. This collection includes nine seawaters from three depth profiles down to 4560 mbsl. The standard deviation (2sigma) of the delta(37)Cl of this collection is +/-0.08 parts per thousand, which is in fact as large as our precision of measurement ( +/- 0.10 parts per thousand). Thus, within error, oceanic waters seem to be an homogeneous reservoir. According to our results, any seawater could be representative of Standard Mean Ocean Chloride (SMOC) and could be used as a reference standard. An extended international cross-calibration over a large range of delta(37)Cl has been completed. For this purpose, geological fluid samples of various chemical compositions and a manufactured CH3Cl gas sample, with delta(37)Cl from about -6 parts per thousand to +6 parts per thousand have been compared. Data were collected by gas source isotope ratio mass spectrometry (IRMS) at the Paris, Reading and Utrecht laboratories and by thermal ionization mass spectrometry (TIMS) at the Leeds laboratory. Comparison of IRMS values over the range -5.3 parts per thousand to +1.4 parts per thousand plots on the Y=X line, showing a very good agreement between the three laboratories. On 11 samples, the trend line between Paris and Reading Universities is: delta(37)Cl(Reading)= (1.007 +/- 0.009)delta(37)Cl(Paris) - (0.040 +/- 0.025), with a correlation coefficient: R-2 = 0.999. TIMS values from Leeds University have been compared to IRMS values from Paris University over the range -3.0 parts per thousand to +6.0 parts per thousand. On six samples, the agreement between these two laboratories, using different techniques is good: delta(37)Cl(Leeds)=(1.052 +/- 0.038)delta(37)Cl(Paris) + (0.058 +/- 0.099), with a correlation coefficient: R-2 = 0.995. The present study completes a previous cross-calibration between the Leeds and Reading laboratories to compare TIMS and IRMS results (Anal. Chem. 72 (2000) 2261). Both studies allow a comparison of IRMS and TIMS techniques between delta(37)Cl values from -4.4 parts per thousand to +6.0 parts per thousand and show a good agreement: delta(37)Cl(TIMS)=(1.039 +/- 0.023)delta(37)Cl(IRMS)+(0.059 +/- 0.056), with a correlation coefficient: R-2 = 0.996. Our study shows that, for fluid samples, if chlorine isotopic compositions are near 0 parts per thousand, their measurements either by IRMS or TIMS will give comparable results within less than +/- 0.10 parts per thousand, while for delta(37)Cl values as far as 10 parts per thousand (either positive or negative) from SMOC, both techniques will agree within less than +/- 0.30 parts per thousand. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
OBJECTIVE: To verify if the reference values of Sleep Apnea cephalometric analysis of North American individuals are similar to the ones of Brazilian individuals presenting no craniofacial anomalies. The study also aimed to identify craniofacial alterations in Obstructive Sleep Apnea-Hypopnea Syndrome (OSAHS) patients in relation to individuals without clinical characteristics of the disease through this cephalometric analysis. METHOD: It were used 55 lateral cephalograms consisting of 29 for the control group of adult individuals without clinical characteristics of OSAHS and 26 apneic adults. All radiographs were submitted to Sleep Apnea cephalometric analysis through Radiocef Studio 2.0. The standard values of this analysis were compared, by means of z test, to the ones obtained from the control group and these were compared to values from apneic group through Student's t test. RESULTS: There were no significant differences between values obtained from control group and standard values. On the group of OSAHS patients it was observed a decrease on the dimensions of upper airways and an increase on the soft palate length. CONCLUSIONS: The standard values of Sleep Apnea analysis can be used as reference in Brazilian individuals. Besides, through lateral cephalograms it was possible to identify craniofacial alterations in OSAHS patients.
Resumo:
It has been highlighted that RNA quality and appropriate reference gene selection is crucial for the interpretation of RT-qPCR results in human placental samples. In this context we investigated the effect of RNA degradation on the mRNA abundance of seven frequently used reference genes in 119 human placental samples. Combining RNA integrity measurements, RT-qPCR analysis and mathematical modeling we found major differences regarding the effect of RNA degradation on the measured expression levels between the different reference genes. Furthermore, we demonstrated that a modified RNA extraction method significantly improved RNA quality and consequently increased transcript levels of all reference genes.
Resumo:
Introduction The purpose of this paper is to present the technical specifications of the Forensic Reference Phantom (FRP), to test its behavior relative to organic test materials, and discuss potential applications of the phantom in forensic radiology. Materials and method The FRP prototype is made of synthetic materials designed to simulate the computed tomography (CT) attenuation of water. It has six bore holes that accommodate multiuse containers. These containers were filled with test materials and scanned at 80 kVp, 120 kVp, and 140 kVp. X-ray attenuation was measured by two readers. Intra- and inter-reader reliability was assessed using the intra-class correlation coefficient (ICC). Significance levels between mean CT numbers at 80 kVp, 120 kVp, and 140 kVp were assessed with the Friedman-test. The T-test was used to assess significance levels between the FRP and water. Results Overall mean CT numbers ranged from −3.0–3.7HU for the FRP; −1000.3–−993.5HU for air; −157.7– −108.1HU for oil; 35.5–42.0HU for musle tissue; and 1301.5–2354.8HU for cortical bone. Inter-reader and intra-reader reliability were excellent (ICC>0.994; and ICC=0.999 respectively). CT numbers were significantly different at different energy levels. There was no significant difference between the attenuation of the FRP and water. Conclusions The FRP is a new tool for quality assurance and research in forensic radiology. The mean CT attenuation of the FRP is equivalent to water. The phantom can be scanned during routine post-mortem CT to assess the composition of unidentified objects. In addition, the FRP may be used to investigate new imaging algorithms and scan protocols in forensic radiology.
Resumo:
At Ny-Ålesund (78.9° N), Svalbard, surface radiation measurements of up- and downward short- and longwave radiation are operated since August 1992 in the frame of the Baseline Surface Radiation Network (BSRN), complemented with surface and upper air meteorology since August 1993. The long-term observations are the base for a climatological presentation of the surface radiation data. Over the 21-year observation period, ongoing changes in the Arctic climate system are reflected. Particularly, the observations indicate a strong seasonality of surface warming and related changes in different radiation parameters. The annual mean temperature at Ny-Ålesund has risen by +1.3 ± 0.7 K per decade, with a maximum seasonal increase during the winter months of +3.1 ± 2.6 K per decade. At the same time, winter is also the season with the largest long-term changes in radiation, featuring an increase of +15.6 ± 11.6 W/m**2 per decade in the downward longwave radiation. Furthermore, changes in the reflected solar radiation during the months of snow melt indicate an earlier onset of the warm season by about 1 week compared to the beginning of the observations. The online available dataset of Ny-Ålesund surface radiation measurements provides a valuable data source for the validation of satellite instruments and climate models.
Basic and other measurements of radiation at Neumayer Station in 2013, reference list of 12 datasets