988 resultados para Rear Lighting Systems.


Relevância:

90.00% 90.00%

Publicador:

Resumo:

An extended research project, funded by the Thomas Pocklington Trust, and carried out by the Research Group for Inclusive Environments (RGIE) at The University of Reading, has examined the lighting found in the homes of people who are visually impaired (VIP). This paper will summarise the results of this substantive study. All the surveyed homes have been occupied by people with sight loss, some of the dwellings were shared with sighted partners. There are several safety issues concerning domestic lighting where inadequate provision may contribute to the incidence of personal injuries occurring in the home. Qualitative and quantitative data from questionnaires, photometric surveys and faceto- face interviews have been obtained from 57 homes. The nature and extent of the visual impairment of each study participant has been identified. This paper will identify important findings from the study, including: a range of areas and tasks within the home that visually impaired people find inadequately lit; the variability of illuminance provided for task lighting and general lighting; and how effective visually impaired people find a selection different lighting systems to those that they commonly use. The research team are able to offer preliminary design guidance for lighting the homes of people who are visually impaired. These will be summarised in the paper.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This study describes a novel spectral LED-based tunable light source used for customized lighting solutions, especially for the reconstruction of CIE (Commission Internationale de l’Éclairage) standard illuminants. The light source comprises 31 spectral bands ranging from 400 to 700 nm, an integrating cube and a control board with a 16-bit resolution. A minimization algorithm to calculate the weighting values for each channel was applied to reproduce illuminants with precision. The differences in spectral fitting and colorimetric parameters showed that the reconstructed spectra were comparable to the standard, especially for the D65, D50, A and E illuminants. Accurate results were also obtained for illuminants with narrow peaks such as fluorescents (F2 and F11) and a high-pressure sodium lamp (HP1). In conclusion, the developed spectral LED-based light source and the minimization algorithm are able to reproduce any CIE standard illuminants with a high spectral and colorimetric accuracy able to advance available custom lighting systems useful in the industry and other fields such as museum lighting.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

National Highway Traffic Safety Administration, Washington, D.C.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

National Highway Traffic Safety Administration, Washington, D.C.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Federal Highway Administration, Office of Research, Washington, D.C.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Public Lightning is an important part of municipality’s nighttime landscape. Lighting can be used to enhance public safety and security while improving the aesthetic appeal of the surrounding properties but with the current global financial crisis, such lighting systems must also be sustainable. Most climate policy efforts focus on the state and international level, however national governments won’t be able to meet their international commitments without local action. In Portugal, the Public Lighting is responsible for 3% of energy consumption. The problem is that the trend is to increase (about 4-5% per year) which represents very high costs for the municipal authorities. In terms of numbers are analyzed in this thesis 45 of 278 existent in Continental Portugal what represents only 16,2 % of the counties. This where the local authorities in Portugal that had a Sustainable Energy Action Plan (SEAP) that had been accepted and made available in the Covenant of Mayors website until the end of year 2013. It is important that the Covenant of Mayors will increase the local authorities awareness for energy efficiency and especially to public lighting because there is still a long way to go in terms of energy consumption reduction. In future works it would be interesting to see the payback of the EolGreen post in a real scenario due to lack of energy consumption from the grid it would allow to have a pretty high initial investment even with the maintenance that those technologies need.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The increasing interest in coral culture for biotechnological applications, to supply the marine aquarium trade, or for reef restoration programs, has prompted researchers to optimize coral culture protocols, with emphasis to ex situ production. When cultured ex situ, the growth performance of corals can be influenced by several physical, chemical and biological parameters. For corals harbouring zooxanthellae, light is one of such key factors, as it can influence the photosynthetic performance of these endosymbionts, as well as coral physiology, survival and growth. The economic feasibility of ex situ coral aquaculture is strongly dependent on production costs, namely those associated with the energetic needs directly resulting from the use of artificial lighting systems. In the present study we developed a versatile modular culture system for experimental coral production ex situ, assembled solely using materials and equipment readily available from suppliers all over the world; this approach allows researchers from different institutions to perform truly replicated experimental set-ups, with the possibility to directly compare experimental results. Afterwards, we aimed to evaluate the effect of contrasting Photosynthetically Active Radiation (PAR) levels, and light spectra emission on zooxanthellae photochemical performance, through the evaluation of the maximum quantum yield of PSII (Fv/Fm) (monitored non-invasively and non-destructively through Pulse Amplitude Modulation fluorometry, PAM), chlorophyll a content (also determined non-destructively by using the spectral reflectance index Normalized Difference Vegetation Index, NDVI), photosynthetic and accessory pigments, number of zooxanthellae, coral survival and growth. We studied two soft coral species, Sarcophyton cf. glaucum and Sinularia flexibilis, as they are good representatives of two of the most specious genera in family Alcyoniidae, which include several species with interest for biotechnological applications, as well as for the marine aquarium trade; we also studied two commercially important scleractinian corals: Acropora formosa and Stylophora pistillata. We used different light sources: hydrargyrum quartz iodide (HQI) lamps with different light color temperatures, T5 fluorescent lamps, Light Emitting Plasma (LEP) and Light Emitting Diode (LED). The results achieved revealed that keeping S. flexibilis fragments under the same light conditions as their mother colonies seems to be photobiologically acceptable for a short-term husbandry, notwithstanding the fact that they can be successfully stocked at lower PAR intensities. We also proved that low PAR intensities are suitable to support the ex situ culture S. cf. glaucum in captivity at lower production costs, since the survival recorded during the experiment was 100%, the physiological wellness of coral fragments was evidenced, and we did not detect significant differences in coral growth. Finally, we concluded that blue light sources, such as LED lighting, allow a higher growth for A. formosa and S. pistillata, and promote significant differences on microstructure organization and macrostructure morphometry in coral skeletons; these findings may have potential applications as bone graft substitutes for veterinary and/or other medical uses. Thus, LED technology seems to be a promising option for scleractinian corals aquaculture ex situ.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Tese de mestrado integrado em Engenharia da Energia e do Ambiente, apresentada à Universidade de Lisboa, através da Faculdade de Ciências, 2016

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dissertação para a obtenção do grau de Mestre em Engenharia Electrotécnica Ramo de Automação e Electrónica Industrial

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Nesta dissertação pretende-se caracterizar o desempenho energético de um grande edifício de serviços existente, da tipologia ensino, avaliar e identificar potenciais medidas que melhorem aquele desempenho, permitindo, em complemento, determinar a sua classificação energética no âmbito da legislação vigente. A pertinência do estudo prende-se com a avaliação do desempenho energético dos edifícios e com o estudo de medidas de melhoria que permitam incrementar a eficiência energética, por recurso a um programa de simulação energética dinâmica certificado – DesignBuilder e tendo em conta a regulamentação portuguesa em vigor. Inicialmente procedeu-se à modelação do edifício com recurso ao programa DesignBuilder, e, simultaneamente, realizou-se um levantamento de todas as suas características ao nível de geometria, pormenores construtivos, sistemas AVAC e de iluminação e fontes de energia utilizadas. Com vista à caracterização do modo de operação do edifício, foi realizado um levantamento dos perfis reais de utilização em termos de ocupação, iluminação e equipamentos para os vários espaços. Foram realizadas medições de caudais de ar novo e da temperatura do ar, em alguns equipamentos e alguns espaços específicos. Foram realizadas medições em tempo real e leituras de contagens da energia eléctrica utilizada, quer em período de aulas quer em período de férias, que permitiram a desagregação das facturas da energia eléctrica que se apresentam globais para o campus do ISEP. Foram realizadas leituras de contagens de gás natural. Em sequência, foi realizada a simulação energética dinâmica com o intuito de ajustar o modelo criado aos consumos reais e de analisar medidas de melhoria que lhe conferissem um melhor desempenho energético. Essas medidas são agrupadas em quatro tipos: - Medidas de natureza comportamental; - Medidas de melhoria da eficiência energética nos sistemas de iluminação; - Medidas de melhoria de eficiência energética nos sistemas AVAC;- Medidas que visam a introdução de energias de fonte renovável; Em sequência, foi elaborada a simulação nominal e calculados os indicadores de eficiência energética com vista à respectiva classificação energética do edifício, tendo o edifício apresentado uma Classe Energética D de acordo com a escala do SCE. Finalmente, foi avaliado o impacto das diferentes medidas de melhoria identificadas e com potencial de aplicação, isto é, que apresentaram um retorno simples do investimento inferior a oito anos, tanto ao nível do desempenho energético real do edifício, como ao nível da sua classificação energética. De onde se concluiu que existe um potencial de 7% de redução nos consumos energéticos actuais do edifício e de 18% se o funcionamento do edifício for em pleno, ou seja, se todos os seus sistemas estiverem efectivamente em funcionamento, e que terá impacto na classificação energética alcançado uma Classe Energética C.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dissertação para obtenção do grau de Mestre em Engenharia Electrotécnica Ramo de Energia