41 resultados para Raffael M. Scheck


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Spiny-backed tree frogs of the genus Osteocephalus are conspicuous components of the tropical wet forests of the Amazon and the Guiana Shield. Here, we revise the phylogenetic relationships of Osteocephalus and its sister group Tepuihyla, using up to 6134 bp of DNA sequences of nine mitochondrial and one nuclear gene for 338 specimens from eight countries and 218 localities, representing 89% of the 28 currently recognized nominal species. Our phylogenetic analyses reveal (i) the paraphyly of Osteocephalus with respect to Tepuihyla, (ii) the placement of 'Hyla' warreni as sister to Tepuihyla, (iii) the non-monophyly of several currently recognized species within Osteocephalus and (iv) the presence of low (<1%) and overlapping genetic distances among phenotypically well-characterized nominal species (e.g. O. taurinus and O. oophagus) for the 16S gene fragment used in amphibian DNA barcoding. We propose a new taxonomy, securing the monophyly of Osteocephalus and Tepuihyla by rearranging and redefining the content of both genera and also erect a new genus for the sister group of Osteocephalus. The colouration of newly metamorphosed individuals is proposed as a morphological synapomorphy for Osteocephalus. We recognize and define five monophyletic species groups within Osteocephalus, synonymize three species of Osteocephalus (O. germani, O. phasmatus and O. vilmae) and three species of Tepuihyla (T. celsae, T. galani and T. talbergae) and reallocate three species (Hyla helenae to Osteocephalus, O. exophthalmus to Tepuihyla and O. pearsoni to Dryaderces gen. n.). Furthermore, we flag nine putative new species (an increase to 138% of the current diversity). We conclude that species numbers are largely underestimated, with most hidden diversity centred on widespread and polymorphic nominal species. The evolutionary origin of breeding strategies within Osteocephalus is discussed in the light of this new phylogenetic hypothesis, and a novel type of amplexus (gular amplexus) is described. © 2013 The Norwegian Academy of Science and Letters.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The crop of soursop has been known for presenting great potential for the domestic market and good prospects for export. In this context, an experiment was conducted in the municipality of Remigio in the state of Paraiba, in order to evaluate the effects of irrigation depths applied weekly on the productive behavior and postharvest quality of fruits of soursop 'Morada' in the soil with and without mulching with crop residues. Treatments were arranged in randomized blocks with three replications and three plants per plot, using a factorial arrangement 5×2, referring to the soil with and without mulching with crop residues, and five irrigation depths of 0, 4.3, 8.6, 12.9 and 17.2 mm plant1. Irrigation was performed manually, once a week from September 2008 to March 2009. The presence of mulch on the soil and increasing depths of irrigation elevated the values of mean mass, production per plant and yield of soursop 'Morada', and decreased the levels of soluble solids.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Customer focus , high competitiveness and striving for excellence in quality of service are some of the main features of the current market . Planned and make decisions with greater certainty is no longer an option a few years . The current managers are seeking ways to eliminate waste and increase financial and productive profitability of your company in order to achieve higher performance at a lower cost . The AHP is one of the main concepts of this goal by providing an analysis on multiple criteria , enhancing decision-making and enhancing the gains , with a technique that is designed to take into account all the key criteria for choosing an alternative , according to the perspective of the designer as both suppliers and customers . Emerging as a new way to minimize errors , and make an informed and consistent decision. The use of this method in construction projects is a recent phenomenon , which has much to be explored , an intense analysis of the processes is required to enable it to consider the concepts and present a consistent and grounded proposal

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Schizophrenia has been defined as a neurodevelopmental disease that causes changes in the process of thoughts, perceptions. and emotions, usually leading to a mental deterioration and affective blunting. Studies have shown altered cell respiration and oxidative stress response in schizophrenia; however, most of the knowledge has been acquired from postmortem brain analyses or from nonneural cells. Here we describe that neural cells, derived from induced pluripotent stem cells generated from skin fibroblasts of a schizophrenic patient, presented a twofold increase in extramitochondrial oxygen consumption as well as elevated levels of reactive oxygen species (ROS), when compared to controls. This difference in ROS levels was reverted by the mood stabilizer valproic acid. Our model shows evidence that metabolic changes occurring during neurogenesis are associated with schizophrenia, contributing to a better understanding of the development of the disease and highlighting potential targets for treatment and drug screening.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bei der vorliegenden Arbeit handelt es sich um ein Ãœberblickswerk zum Christusbild, dem Aussehen Christi in der deutschen Bildkunst des 19. Jahrhunderts und dessen Wandlungen. Grundlage der Arbeit bildet eine von der Autorin zusammengetragene Materialsammlung und deren Auswertung, basierend auf der Kenntnis von Originalen sowie der Sichtung von Literatur (insbesondere von Lexika, Museums- und Ausstellungskatalogen, Werkverzeichnissen sowie maßgeblichen deutschen Kunstzeitschriften des 19. Jahrhunderts). Das hieraus resultierende systematische Bildverzeichnis umfasst 1.914 Werke in Form von Staffeleibildern, Druckgraphik, wandgebundenen Ge¤lden (und auch Skulpturen); davon sind 729 mit Abbildungen in der Arbeit dokumentiert. In alphabetischer Reihenfolge abgefasst, enthält das Verzeichnis zu jedem Eintrag Kurzinformationen zu Werk und Künstler, sowie Literatur- und ggf. Abbildungsnachweise. Auf dieser Basis geht die Untersuchung über den bisher relativ kleinen Kreis einschlägig bekannter Christusbilder weit hinaus und gibt erstmals einen umfassenden und für das 19. Jahrhundert repräsentativen Ãœberblick.rnDer auf dieses Material gestützte Hauptteil befasst sich mit der eingehenden Betrachtung der „Grundtypen“ des Christusbildes, womit das Aussehen Christi (Physiognomie, Gesamtgestalt, Gewandung, Habitus und Gestik) gemeint ist. Schwerpunkte der Arbeit bilden zunächst das an der Renaissance (insbesondere an Raffael) orientierte „milde“ Christusbild des Klassizismus und die „inniglich-schöne“ Idealgestalt der Romantik (variiert auch mit altdeutschen Elementen), aus der schließlich das bis in die Gegenwart verwendete, kitschig-süßliche Devotionalienbild resultierte. Eine historisierende, ethnologische Rekonstruktion eines „jüdischen“ Jesus, erschien besonders in der „Orientmalerei“ seit den vierziger Jahren des 19. Jahrhunderts. Die Ablehnung und Abgrenzung der Orientmalerei führte zu einer „historischen Reformationsmalerei“ mit altdeutschen Elementen und auch teilweise zu einer Tendenz der „Germanisierung“ des Bildes Jesu mit genrehaften Zügen. Zum Jahrhundertende hin wurden außerdem vielfältige Versuche beobachtet, den Gottmenschen Jesus in „zeitgenössische€œ Aussehen volksnah in die Gegenwart der Gläubigen einzubinden. Im Symbolismus traten hingegen heroisierende Tendenzen auf bis hin zu einer „Entwirklichung“ der Gestalt Christi. Zusammenfassende Beobachtungen zu den häufig verwendeten und „beliebten“ Themen der Christusdarstellung im 19. Jahrhundert runden die Arbeit ab, in der eine bislang ungekannte Differenzierung und Vielfalt der Darstellungs¶glichkeiten Christi in der religiösen Kunst des 19. Jahrhunderts aufgezeigt werden konnte.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a novel mock circulation for the evaluation of ventricular assist devices (VADs), which is based on a hardware-in-the-loop concept. A numerical model of the human blood circulation runs in real time and computes instantaneous pressure, volume, and flow rate values. The VAD to be tested is connected to a numerical-hydraulic interface, which allows the interaction between the VAD and the numerical model of the circulation. The numerical-hydraulic interface consists of two pressure-controlled reservoirs, which apply the computed pressure values from the model to the VAD, and a flow probe to feed the resulting VAD flow rate back to the model. Experimental results are provided to show the proper interaction between a numerical model of the circulation and a mixed-flow blood pump.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Current pulsatile ventricular assist devices operate asynchronous with the left ventricle in fixed-rate or fill-to-empty modes because electrocardiogram-triggered modes have been abandoned. We hypothesize that varying the ejection delay in the synchronized mode yields more precise control of hemodynamics and left ventricular loading. This allows for a refined management that may be clinically beneficial. METHODS: Eight sheep received a Thoratec paracorporeal ventricular assist device (Thoratec Corp, Pleasanton, Calif) via ventriculo-aortic cannulation. Left ventricular pressure and volume, aortic pressure, pulmonary flow, pump chamber pressure, and pump inflow and outflow were recorded. The pump was driven by a clinical pneumatic drive unit (Medos Medizintechnik AG, Stolberg, Germany) synchronously with the native R-wave. The start of pump ejection was delayed between 0% and 100% of the cardiac period in 10% increments. For each of these delays, hemodynamic variables were compared with baseline data using paired t tests. RESULTS: The location of the minimum of stroke work was observed at a delay of 10% (soon after aortic valve opening), resulting in a median of 43% reduction in stroke work compared with baseline. Maximum stroke work occurred at a median delay of 70% with a median stroke work increase of 11% above baseline. Left ventricular volume unloading expressed by end-diastolic volume was most pronounced for copulsation (delay 0%). CONCLUSIONS: The timing of pump ejection in synchronized mode yields control over left ventricular energetics and can be a method to achieve gradual reloading of a recoverable left ventricle. The traditionally suggested counterpulsation is not optimal in ventriculo-aortic cannulation when maximum unloading is desired.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Multiple organ failure is a common complication of acute circulatory and respiratory failure. We hypothesized that therapeutic interventions used routinely in intensive care can interfere with the perfusion of the gut and the liver, and thereby increase the risk of mismatch between oxygen supply and demand. DESIGN: Prospective, observational study. SETTING: Interdisciplinary intensive care unit (ICU) of a university hospital. PATIENTS: Thirty-six patients on mechanical ventilation with acute respiratory or circulatory failure or severe infection were included. INTERVENTIONS: Insertion of a hepatic venous catheter. MEASUREMENTS AND MAIN RESULTS: Daily nursing procedures were recorded. A decrease of >or=5% in hepatic venous oxygen saturation (Sho2) was considered relevant. Observation time was 64 (29-104) hours (median [interquartile range]). The ICU stay was 11 (8-15) days, and hospital mortality was 35%. The number of periods with procedures/patient was 170 (98-268), the number of procedure-related decreases in Sho2 was 29 (13-41), and the number of decreases in Sho2 unrelated to procedures was 9 (4-19). Accordingly, procedure-related Sho2 decreases occurred 11 (7-17) times per day. Median Sho2 decrease during the procedures was 7 (5-10)%, and median increase in the gradient between mixed and hepatic venous oxygen saturation was 6 (4-9)%. Procedures that caused most Sho2 decreases were airway suctioning, assessment of level of sedation, and changing patients' position. Sho2 decreases were associated with small but significant increases in heart rate and intravascular pressures. Maximal Sequential Organ Failure Assessment scores in the ICU correlated with the number of Sho2 decreases (r: .56; p < 0.001) and with the number of procedure-related Sho2 decreases (r: .60; p < 0.001). CONCLUSIONS: Patients are exposed to repeated episodes of impaired splanchnic perfusion during routine nursing procedures. More research is needed to examine the correlation, if any, between nursing procedures and hepatic venous desaturation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The current article presents a novel physiological control algorithm for ventricular assist devices (VADs), which is inspired by the preload recruitable stroke work. This controller adapts the hydraulic power output of the VAD to the end-diastolic volume of the left ventricle. We tested this controller on a hybrid mock circulation where the left ventricular volume (LVV) is known, i.e., the problem of measuring the LVV is not addressed in the current article. Experiments were conducted to compare the response of the controller with the physiological and with the pathological circulation, with and without VAD support. A sensitivity analysis was performed to analyze the influence of the controller parameters and the influence of the quality of the LVV signal on the performance of the control algorithm. The results show that the controller induces a response similar to the physiological circulation and effectively prevents over- and underpumping, i.e., ventricular suction and backflow from the aorta to the left ventricle, respectively. The same results are obtained in the case of a disturbed LVV signal. The results presented in the current article motivate the development of a robust, long-term stable sensor to measure the LVV.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ventricular assist devices (VADs) are blood pumps that offer an option to support the circulation of patients with severe heart failure. Since a failing heart has a remaining pump function, its interaction with the VAD influences the hemodynamics. Ideally, the heart's action is taken into account for actuating the device such that the device is synchronized to the natural cardiac cycle. To realize this in practice, a reliable real-time algorithm for the automatic synchronization of the VAD to the heart rate is required. This paper defines the tasks such an algorithm needs to fulfill: the automatic detection of irregular heart beats and the feedback control of the phase shift between the systolic phases of the heart and the assist device. We demonstrate a possible solution to these problems and analyze its performance in two steps. First, the algorithm is tested using the MIT-BIH arrhythmia database. Second, the algorithm is implemented in a controller for a pulsatile and a continuous-flow VAD. These devices are connected to a hybrid mock circulation where three test scenarios are evaluated. The proposed algorithm ensures a reliable synchronization of the VAD to the heart cycle, while being insensitive to irregularities in the heart rate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The clinical importance of pulsatility is a recurring topic of debate in mechanical circulatory support. Lack of pulsatility has been identified as a possible factor responsible for adverse events and has also demonstrated a role in myocardial perfusion and cardiac recovery. A commonly used method for restoring pulsatility with rotodynamic blood pumps (RBPs) is to modulate the speed profile, synchronized to the cardiac cycle. This introduces additional parameters that influence the (un)loading of the heart, including the timing (phase shift) between the native cardiac cycle and the pump pulses, and the amplitude of speed modulation. In this study, the impact of these parameters upon the heart-RBP interaction was examined in terms of the pressure head-flow (HQ) diagram. The measurements were conducted using a rotodynamic Deltastream DP2 pump in a validated hybrid mock circulation with baroreflex function. The pump was operated with a sinusoidal speed profile, synchronized to the native cardiac cycle. The simulated ventriculo-aortic cannulation showed that the level of (un)loading and the shape of the HQ loops strongly depend on the phase shift. The HQ loops displayed characteristic shapes depending on the phase shift. Increased contribution of native contraction (increased ventricular stroke work [WS ]) resulted in a broadening of the loops. It was found that the previously described linear relationship between WS and the area of the HQ loop for constant pump speeds becomes a family of linear relationships, whose slope depends on the phase shift.