25 resultados para Radiopacidade


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sealer 26® cement contains bisphenol epoxy resin associated with calcium hydroxide, presenting smaller radiopacity than other endodontic cements. Aiming to improve this property, iodoform has been added in its composition. However, this addition's possible changes in physical and chemical properties still need to be studied. OBJECTIVE: To evaluate the apical sealing ability, solubility, and pH of Sealer 26® alone or with iodoform, at several proportions. MATERIAL AND METHODS: Three experimental mixtures of Sealer 26®, alone or with iodoform, were prepared and subjected to solubility test. Additionally, these combinations were inserted into polyethylene tubes and immersed in distilled water, and, their pH was evaluated after 24-h and 7-day periods. Subsequently, forty roots of extracted lower incisors subdivided into four groups of 10 specimens each, were retrograde filled with one of the previously described mixtures and gutta-percha points. The roots were immersed in Rhodamine B, under vacuum, for 72 hours. After this period, the specimens were longitudinally sectioned, root fragments photographed, these images scanned, and apical infiltration measured by Image tool software. The obtained data were subjected to statistical analysis, at a significance level of 5%. RESULTS: Marginal leakage and solubility tests did not show any difference among the experimental groups (p > 0.05). pH analysis was only statistically different at 24-h period and between Sealer 26® alone and 1.1g iodoform group (p < 0.05). CONCLUSION: The presence of iodoform in Sealer 26®, at the used proportions, did not alter the solubility, apical marginal leakage and pH properties of the original cement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study evaluated the radiopacity and flow of different endodontic sealers: AH Plus, Endo CPM, MTA Fillapex, Sealapex, Epiphany, and Epiphany SE. For the radiopacity test, six specimens measuring 10mm in diameter and 1mm in thickness were fabricated from each material. They were radiographed on an occlusal film alongside an aluminum step wedge. Radiographs were digitized to determine the radiopacity equivalence in millimeters of aluminum. To evaluate the flow, a 120 g load was placed on top of a glass slab containing 0.05 } 0.005ml of sealer. The diameters of each material were measured (mm) with a caliper and samples were photographed. Digitized images were analyzed using the UTHSCSA Image Tool for Windows software, to determine the sealer area (mm2). Data were submitted to ANOVA and Tukey's test at 5% significance. AH Plus and Epiphany SE presented the greatest radiopacity (12.5 mm Al and 12.0 mm Al, respectively) (p>0.05), followed by Epiphany (9.6 mm Al) and Fillapex (8.9 mm Al). Endo CPM (5.46 mm Al) and Sealapex (5.51 mm Al) presented lower radiopacity. MTA Fillapex presented significantly higher values of flow than other sealers (33.11 mm and 844.9 mm2). AH Plus, Epiphany, and Epiphany SE had similar values. Endo CPM (21.05 mm and 342.8 mm2) and Sealapex (19.98 mm and 352.5 mm2) presented the lowest flow values (p>0.05). All sealers presented radiopacity and flow values according to ISO and ANSI/ADA recommendations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the radiopacity of two conventional cements (Zinc Cement and Ketac Cem Easymix), one resin-modified glass ionomer cement (RelyX Luting 2) and six resin cements (Multilink, Bistite II DC, RelyX ARC, Fill Magic Dual Cement, Enforce and Panavia F) by digitization of images. Methods. Five disc-shaped specimens (10×1.0 mm) were made for each material, according to ISO 4049. After setting of the cements, radiographs were made using occlusal films and a graduated aluminum stepwedge varying from 1.0 to 16 mm in thickness. The radiographs were digitized, and the radiopacity of the cements was compared with the aluminum stepwedge using the software VIXWIN-2000. Data (mmAl) were submitted to one-way ANOVA and Tukey's test (=0.05). Results. The Zinc Cement was the most radiopaque material tested (<0.05). The resin cements presented higher radiopacity (<0.05) than the conventional (Ketac Cem Easymix) or resin-modified glass ionomer (RelyX Luting 2) cements, except for the Fill Magic Dual Cement and Enforce. The Multilink presented the highest radiopacity (<0.05) among the resin cements. Conclusion. The glass ionomer-based cements (Ketac Cem Easymix and RelyX Luting 2) and the resin cements (Fill Magic Dual Cement and Enforce) showed lower radiopacity values than the minimum recommended by the ISO standard.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: It has been suggested that bone grafts combined with platelet rich plasma (PRP) present greater density than bone grafts without PRP after healing process. However, this result may depend on proportion PRP/autogenous bone (AB) graft used. Objective: The purpose of this study was to analyze radiographically the influence of the proportion PRP/particulate autogenous bone (AB) graft on bone healing in surgically created criticalsize defects (CSD) in rat calvaria. Material and method: 50 rats were divided into 5 groups: C, AB, AB/PRP-50, AB/PRP-100 and AB/PRP-150. A 5 mm diameter CSD was created in the calvarium of each animal. In Group C the defect was filled by blood clot only. In Group AB the defect was filled with 0.01 mL of AB graft. In groups AB/ RP-50, AB/PRP-100 and AB/PRP-150 the defects were filled with 0.01 mL of AB graft combined with 50, 100 and 150 µL of PRP, respectively. All animals were euthanized at 30 days post-operative. Standardized radiographic images of the rat calvaria were obtained using Digora System (Soredex, Finland). The images were evaluated by three examiners using scores that indicated the percentage of radiopacity of the defect. The obtained data were subjected to statistical analysis (Kruskal-Wallis test, p < 0.05). Result: Group C presented radiopacity significantly lower than groups AB, AB/PRP-50, AB/PRP-100 and AB/PRP-150. Group AB/PRP-50 showed radiopacity significantly greater than groups AB/PRP-100 and AB. Conclusion: It can be concluded that the proportion PRP/AB graft influences bone healing in CSD in rat calvaria.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A displasia cemento-óssea é o tipo mais comum dentre as lesões fibro-ósseas, podendo apresentar-se de 3 maneiras: periapical, focal e florida. Paciente parda, de 53 anos, compareceu com queixa de “secreção na gengiva” e histórico de exodontia na região há 8 meses. À inspeção apresentou uma leve tumefação na região vestibular posterior esquerda da mandíbula e uma pequena fístula drenando pus. Realizou-se uma radiografia panorâmica, que revelou uma lesão de radiopacidade mista na região de molares inferiores direitos, medindo 2 cm de diâmetro; outra lesão radiopaca na região de pré-molares esquerdos, de 6mm de diâmetro - ambas bem delimitadas; e outra área radiolúcida com radiopacidade central, com halo radiopaco na região infectada, medindo 1,5 cm de diâmetro. O diagnóstico presuntivo foi de displasia cemento-óssea infectada, cisto periapical infectado associado à displasia e osteomielite. Após antibioticoterapia, realizou-se biópsia e curetagem da área. Microscopicamente apresentou áreas de tecido cemento-ósseo em forma trabecular e no local onde deveria haver tecido fibroso, presença de biofilme bacteriano, conteúdo hemorrágico e restos necróticos. No tecido de granulação removido observou-se intenso infiltrado inflamatório e áreas de calcificação cementóide. As características microscópicas juntamente com os achados clínicos e radiográficos levaram ao diagnóstico de osteomielite aguda supurativa secundária a lesão fibro-óssea, sugestiva de displasia cemento-óssea florida.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)