998 resultados para Radiology technicians


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Plain radiography still accounts for the vast majority of imaging studies that are performed at multiple clinical instances. Digital detectors are now prominent in many imaging facilities and they are the main driving force towards filmless environments. There has been a working paradigm shift due to the functional separation of acquisition, visualization, and storage with deep impact in the imaging workflows. Moreover with direct digital detectors images are made available almost immediately. Digital radiology is now completely integrated in Picture Archiving and Communication System (PACS) environments governed by the Digital Imaging and Communications in Medicine (DICOM) standard. In this chapter a brief overview of PACS architectures and components is presented together with a necessarily brief account of the DICOM standard. Special focus is given to the DICOM digital radiology objects and how specific attributes may now be used to improve and increase the metadata repository associated with image data. Regular scrutiny of the metadata repository may serve as a valuable tool for improved, cost-effective, and multidimensional quality control procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several antineoplasic drugs have been demonstrated to be carcinogenic or to have mutagenic and teratogenic effects. The greatest protection is achieved with the implementation of administrative and engineering controls and safety procedures. Objective: to evaluate the improvements on pharmacy technicians' work practices, after the implementation of operational procedures related to individual protection, biologic safety cabinet disinfection and cytotoxic drug preparation. Method: case-study in a hospital pharmacy undergoing a certification process. Six pharmacy technicians were observed during their daily activities. Characterization of the work practices was made using a checklist based on ISOPP and PIC guidelines. The variables studied concerning cleaning/disinfection procedures, personal protective equipment and procedures for preparing cytotoxic drugs. The same work practices were evaluated after four months of operational procedures implementation. Concordance between work practices and guidelines was considered to be a quality indicator (guidelines concordance practices number/total number of practices x 100). Results: improvements were observed after operational procedures implementation. An improvement of 6,25% in personal protective equipment practice was achieved by changing second pair of gloves every thirty minutes. The major progress, 10%, was obtained in disinfection procedure, where 80% of tasks are now realized according to guidelines.By now, we hot an improvement of only 1% at drug preparation procedure by placing one cytotoxic drug at a time inside the biological safety cabinet. Then, 85% of practices are according to guidelines. Conclusion: before operational procedures implementation 80,3% of practices were according to the guidelines, while now is 84,4%. This indicates that is necessary to review the procedures frequently in the benefit to reduce the risks associated with handling cytotoxic drugs and maintenance of drug specifications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Designing electric installation projects, demands not only academic knowledge, but also other types of knowledge not easily acquired through traditional instructional methodologies. A lot of additional empirical knowledge is missing and so the academic instruction must be completed with different kinds of knowledge, such as real-life practical examples and simulations. On the other hand, the practical knowledge detained by the most experienced designers is not formalized in such a way that is easily transmitted. In order to overcome these difficulties present in the engineers formation, we are developing an Intelligent Tutoring System (ITS), for training and support concerning the development of electrical installation projects to be used by electrical engineers, technicians and students.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Segurança e Higiene do Trabalho.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Medical imaging is a powerful diagnostic tool. Consequently, the number of medical images taken has increased vastly over the past few decades. The most common medical imaging techniques use X-radiation as the primary investigative tool. The main limitation of using X-radiation is associated with the risk of developing cancers. Alongside this, technology has advanced and more centres now use CT scanners; these can incur significant radiation burdens compared with traditional X-ray imaging systems. The net effect is that the population radiation burden is rising steadily. Risk arising from X-radiation for diagnostic medical purposes needs minimising and one way to achieve this is through reducing radiation dose whilst optimising image quality. All ages are affected by risk from X-radiation however the increasing population age highlights the elderly as a new group that may require consideration. Of greatest concern are paediatric patients: firstly they are more sensitive to radiation; secondly their younger age means that the potential detriment to this group is greater. Containment of radiation exposure falls to a number of professionals within medical fields, from those who request imaging to those who produce the image. These staff are supported in their radiation protection role by engineers, physicists and technicians. It is important to realise that radiation protection is currently a major European focus of interest and minimum competence levels in radiation protection for radiographers have been defined through the integrated activities of the EU consortium called MEDRAPET. The outcomes of this project have been used by the European Federation of Radiographer Societies to describe the European Qualifications Framework levels for radiographers in radiation protection. Though variations exist between European countries radiographers and nuclear medicine technologists are normally the professional groups who are responsible for exposing screening populations and patients to X-radiation. As part of their training they learn fundamental principles of radiation protection and theoretical and practical approaches to dose minimisation. However dose minimisation is complex – it is not simply about reducing X-radiation without taking into account major contextual factors. These factors relate to the real world of clinical imaging and include the need to measure clinical image quality and lesion visibility when applying X-radiation dose reduction strategies. This requires the use of validated psychological and physics techniques to measure clinical image quality and lesion perceptibility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Based on the report for “Project IV” unit of the PhD programme on Technology Assessment (Doctoral Conference) at Universidade Nova de Lisboa (December 2011). This thesis research has the supervision of António Moniz (FCT-UNL and ITAS-KIT) and Michael Decker (Karlsruhe Institute of Technology-ITAS). Other members of the thesis committee are Carlos Alberto da Silva (University of Évora), José Maria de Albuquerque (Institute of Welding and Quality), Lotte Steuten (University of Twente), Mário Forjaz Secca (FCT-UNL) and Nelson Chibeles Martins (FCT-UNL).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Based on the report for the unit “Project III” of the PhD programme on Technology Assessment in 2011. The unit was supervised by Prof. António B. Moniz (FCT-UNL).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: The purpose of this study was to compare respiratory signs and symptoms between patients with and without chest X-ray abnormalities in order to establish the meaning of radiographic findings in pulmonary PCM diagnosis. METHODS: The epidemiological, clinical and radiological lung findings of 44 patients with paracoccidiodomycosis (PCM) were evaluated. Patients were divided into two groups of 23 and 21 individuals according to the presence (group 1) or absence (group 2) of chest X-ray abnormalities, respectively, and their clinical data was analyzed with the aid of statistical tools. RESULTS: As a general rule, patients were rural workers, young adult males and smokers - group 1 and 2, respectively: males (91.3% and 66.7%); mean age (44.4 and 27.9 year-old); smoking (34.7% and 71.4 %); acute/subacute presentation (38.1% and 21.7%); chronic presentation (61.9% and 78.3%). The most frequent respiratory manifestations were - group 1 and 2, respectively: cough (25% and 11.4%) and dyspnea (22.7% and 6.8%). No statistical difference was observed in pulmonary signs and symptoms between patients with or without radiographic abnormalities. The most frequent radiological finding was nodular (23.8%) or nodular-fibrous (19%), bilateral (90.5%) and diffuse infiltrates (85.7%). CONCLUSIONS: Absence of statistical difference in pulmonary signs and symptoms between these two groups of patients with PCM indicates clinical-radiological dissociation. A simplified classification of radiological lung PCM findings is suggested, based on correlation of these data and current literature review.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A wide variation in patient exposure has been observed in interventional radiology and cardiology. The purpose of this study was to investigate the patient dose from fluoroscopy-guided procedures performed in non-academic centres when compared with academic centres. Four procedures (coronary angiography, percutaneous coronary intervention, angiography of the lower limbs and percutaneous transluminal angioplasty of the lower limbs) were evaluated. Data on the dose-area product, fluoroscopy time and number of images for 1000 procedures were obtained from 23 non-academic centres and compared with data from 5 academic centres. No differences were found for cardiology procedures performed in non-academic centres versus academic ones. However, significantly lower doses were delivered to patients for procedures of the lower limbs when they were performed in non-academic centres. This may be due to more complex procedures performed in the academic centres. Comparison between the centres showed a great variation in the patient dose for these lower limb procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main objective of WP1 of the ORAMED (Optimization of RAdiation protection for MEDical staff) project is to obtain a set of standardised data on extremity and eye lens doses for staff in interventional radiology (IR) and cardiology (IC) and to optimise staff protection. A coordinated measurement program in different hospitals in Europe will help towards this direction. This study aims at analysing the first results of the measurement campaign performed in IR and IC procedures in 34 European hospitals. The highest doses were found for pacemakers, renal angioplasties and embolisations. Left finger and wrist seem to receive the highest extremity doses, while the highest eye lens doses are measured during embolisations. Finally, it was concluded that it is difficult to find a general correlation between kerma area product and extremity or eye lens doses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To quantify the prevalence of accidental blood exposure (ABE) among interventional radiologists and contrast that with the prevalence of patients with hepatitis C virus (HCV) undergoing interventional radiology procedures. MATERIALS AND METHODS: A multicenter epidemiologic study was conducted in radiology wards in France. The risk of ABE to radiologists was assessed based on personal interviews that determined the frequency and type of ABE and the use of standard protective barriers. Patients who underwent invasive procedures underwent prospective sampling for HCV serologic analysis. HCV viremia was measured in patients who tested positive for HCV. RESULTS: Of the 77 radiologists who participated in 11 interventional radiology wards, 44% reported at least one incident of mucous membrane blood exposure and 52% reported at least one percutaneous injury since the beginning of their occupational activity. Compliance with standard precautions was poor, especially for the use of protective clothes and safety material. Overall, 91 of 944 treated patients (9.7%) tested positive for HCV during the study period, of whom 90.1% had positive viremia results, demonstrating a high potential for contamination through blood contacts. CONCLUSIONS: The probability of HCV transmission from contact with contaminated blood after percutaneous injury ranged from 0.013 to 0.030; the high frequency of accidental blood exposure and high percentage of patients with HCV could generate a risk of exposure to HCV for radiologists who perform invasive procedures with frequent blood contact. The need to reinforce compliance with standard hygiene precautions is becoming crucial for medical and technical personnel working in these wards.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Report Published July 1999

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Report Published June 2001 - Contains key recommendations and the way forward

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Physicians who frequently perform fluoroscopic examinations are exposed to high intensity radiation fields. The exposure monitoring is performed with a regular personal dosimeter under the apron in order to estimate the effective dose. However, large parts of the body are not protected by the apron (e.g. arms, head). Therefore, it is recommended to wear a supplemental dosimeter over the apron to obtain a better representative estimate of the effective dose. The over-apron dosimeter can also be used to estimate the eye lens dose. The goal of this study was to investigate the relevance of double dosimetry in interventional radiology. First the calibration procedure of the dosimeters placed over the apron was tested. Then, results of double dosimetry during the last five years were analyzed. We found that the personal dose equivalent measured over a lead apron was underestimated by ∼20% to ∼40% for X-ray beam qualities used in radiology. Measurements made over five-year period confirm that the use of a single under-apron dosimeter is inadequate for personnel monitoring. Relatively high skin dose (>10 mSv/month) would have remained undetected without a second dosimeter placed on the apron.