969 resultados para Radiology technician procedures


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A wide variation in patient exposure has been observed in interventional radiology and cardiology. The purpose of this study was to investigate the patient dose from fluoroscopy-guided procedures performed in non-academic centres when compared with academic centres. Four procedures (coronary angiography, percutaneous coronary intervention, angiography of the lower limbs and percutaneous transluminal angioplasty of the lower limbs) were evaluated. Data on the dose-area product, fluoroscopy time and number of images for 1000 procedures were obtained from 23 non-academic centres and compared with data from 5 academic centres. No differences were found for cardiology procedures performed in non-academic centres versus academic ones. However, significantly lower doses were delivered to patients for procedures of the lower limbs when they were performed in non-academic centres. This may be due to more complex procedures performed in the academic centres. Comparison between the centres showed a great variation in the patient dose for these lower limb procedures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To quantify the prevalence of accidental blood exposure (ABE) among interventional radiologists and contrast that with the prevalence of patients with hepatitis C virus (HCV) undergoing interventional radiology procedures. MATERIALS AND METHODS: A multicenter epidemiologic study was conducted in radiology wards in France. The risk of ABE to radiologists was assessed based on personal interviews that determined the frequency and type of ABE and the use of standard protective barriers. Patients who underwent invasive procedures underwent prospective sampling for HCV serologic analysis. HCV viremia was measured in patients who tested positive for HCV. RESULTS: Of the 77 radiologists who participated in 11 interventional radiology wards, 44% reported at least one incident of mucous membrane blood exposure and 52% reported at least one percutaneous injury since the beginning of their occupational activity. Compliance with standard precautions was poor, especially for the use of protective clothes and safety material. Overall, 91 of 944 treated patients (9.7%) tested positive for HCV during the study period, of whom 90.1% had positive viremia results, demonstrating a high potential for contamination through blood contacts. CONCLUSIONS: The probability of HCV transmission from contact with contaminated blood after percutaneous injury ranged from 0.013 to 0.030; the high frequency of accidental blood exposure and high percentage of patients with HCV could generate a risk of exposure to HCV for radiologists who perform invasive procedures with frequent blood contact. The need to reinforce compliance with standard hygiene precautions is becoming crucial for medical and technical personnel working in these wards.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to investigate the radiation exposure of the Swiss population to interventional procedures. A nationwide survey was conducted in Switzerland. The annual effective dose per capita due to interventional procedures was found to be 0.14 mSv, corresponding to 12% of the total dose. Coronary angiography and percutaneous coronary interventions were found to be the most frequent and the most irradiating interventional procedures, accounting for 52% of the total examination frequency and 64% of the dose delivered to the population. Switzerland stands at the same level as other countries in terms of effective dose per capita due to interventional radiology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Active personal dosemeters (APD) have been found to be very efficient tools to reduce occupational doses in many applications of ionizing radiation. In order to be used in interventional radiology and cardiology (IR/IC), APDs should be able to measure low energy photons and pulsed radiation with relatively high instantaneous personal dose equivalent rates. A study concerning the optimization of the use of APDs in IR/IC was performed in the framework of the ORAMED project, a Collaborative Project (2008-2011) supported by the European Commission within its 7th Framework Program. In particular, eight commercial APDs were tested in continuous and pulsed X-ray fields delivered by calibration laboratories in order to evaluate their performances. Most of APDs provide a response in pulsed mode more or less affected by the personal dose equivalent rate, which means they could be used in routine monitoring provided that correction factors are introduced. These results emphasize the importance of adding tests in pulsed mode in type-test procedures for APDs. Some general recommendations are proposed in the end of this paper for the selection and use of APDs at IR/IC workplaces.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The availability of intra-arterial hepatic therapies (radio and/or chemo-embolisation, intra-arterial hepatic chemotherapy) has convinced radiologists to perfect their knowledge of the anatomy of the liver arteries. These sometimes, complex procedures most often require selective arterial catheterization. Knowledge of the different arteries in the liver and the peripheral organs is therefore essential to optimize the procedure and avoid eventual complications. This paper aims to describe the anatomy of the liver arteries and the variants, applying it to angiography images, and to understand the implications of such variations in interventional radiological procedures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A thorough literature review about the current situation on the implementation of eye lens monitoring has been performed in order to provide recommendations regarding dosemeter types, calibration procedures and practical aspects of eye lens monitoring for interventional radiology personnel. Most relevant data and recommendations from about 100 papers have been analysed and classified in the following topics: challenges of today in eye lens monitoring; conversion coefficients, phantoms and calibration procedures for eye lens dose evaluation; correction factors and dosemeters for eye lens dose measurements; dosemeter position and influence of protective devices. The major findings of the review can be summarised as follows: the recommended operational quantity for the eye lens monitoring is H p (3). At present, several dosemeters are available for eye lens monitoring and calibration procedures are being developed. However, in practice, very often, alternative methods are used to assess the dose to the eye lens. A summary of correction factors found in the literature for the assessment of the eye lens dose is provided. These factors can give an estimation of the eye lens dose when alternative methods, such as the use of a whole body dosemeter, are used. A wide range of values is found, thus indicating the large uncertainty associated with these simplified methods. Reduction factors from most common protective devices obtained experimentally and using Monte Carlo calculations are presented. The paper concludes that the use of a dosemeter placed at collar level outside the lead apron can provide a useful first estimate of the eye lens exposure. However, for workplaces with estimated annual equivalent dose to the eye lens close to the dose limit, specific eye lens monitoring should be performed. Finally, training of the involved medical staff on the risks of ionising radiation for the eye lens and on the correct use of protective systems is strongly recommended.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective The present study was aimed at estimating the doses received by physicians and patients during cerebral angiography procedures in a public hospital of Recife, PE, Brazil. Materials and Methods The study sample included 158 adult patients, and during the procedures the following parameters were evaluated: exposure parameters (kV, mAs), number of acquired images, reference air kerma value (Ka,r) and air kerma-area product (PKA). Additionally, the physicians involved in the procedures were evaluated as for absorbed dose in the eyes, thyroid, chest, hands and feet. Results The results demonstrated that the doses to the patients' eyes region were relatively close to the threshold for cataract occurrence. As regards the physicians, the average effective dose was 2.6 µSv, and the highest effective dose recorded was 16 µSv. Conclusion Depending on the number of procedures, the doses received by the physicians may exceed the annual dose limit for the crystalline lenses (20 mSv) established by national and international standards. It is important to note that the high doses received by the physicians are due to the lack of radiation protection equipment and accessories, such as leaded curtains, screens and protective goggles.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AbstractObjective:The present study was aimed at reviewing the literature to identify solutions for problems observed in radiology services.Materials and Methods:Basic, qualitative, exploratory literature review at Scopus and SciELO databases, utilizing the Mendeley and Illustrator CC Adobe softwares.Results:In the databases, 565 papers – 120 out of them, pdf free – were identified. Problems observed in the radiology sector are related to procedures scheduling, humanization, lack of training, poor knowledge and use of management techniques, and interaction with users. The design management provides the services with interesting solutions such as Benchmarking, CRM, Lean Approach, ServiceBlueprinting, continued education, among others.Conclusion:Literature review is an important tool to identify problems and respective solutions. However, considering the small number of studies approaching management of radiology services, this is a great field of research for the development of deeper studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aims to determine the entrance surface skin doses in dogs (with suspected pulmonary metastasis) submitted to chest X-rays using the technique of thermoluminescence (TL) dosimetry. Twenty seven radiologic exams of dogs of different breed and sizes were performed. The radiation doses were assessed using thermoluminescent dosimeters of calcium sulphate doped with dysprosium (CaSO(4):Dy) produced at Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN). The entrance surface skin dose range evaluated in this type of procedure was between 0.43 mGy to small size dogs and 4.22 mGy to big size dogs with repeated exams. The obtained results indicate that is extremely important the assessment of radiation doses involved in veterinary diagnostic radiology procedures, to evaluate the delivered doses to the animals, to be used as a parameter in the individual monitoring of pet's owners, who assist the animal positioning, and to protect occupationally exposed workers at the Veterinary Radiology Clinics. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aims the evaluation of the radiation dose levels involved in veterinary radiology and to contribute to review the procedures for performing radiographic exams in animals in the Department of Veterinary Radiology of Faculdade de Medicina Veterinária e Zootecnia of Universidade Estadual Paulista (FMVZ-UNESP/Brazil). The obtained results has shown to be extremely important the assessment of doses involved in veterinary diagnostic radiology procedures both to protect the occupationally exposed workers and to optimize the delivered doses to the animals. © 2009 Springer-Verlag.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Protective occlusion of the gastroduodenal artery (GDA) is required to avoid severe adverse effects and complications in radioembolization procedures. Because of the expandable features of HydroCoils, our goal was to occlude the GDA with only one HydroCoil to provide particle reflux protection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To compare objective fellow and expert efficiency indices for an interventional radiology renal artery stenosis skill set with the use of a high-fidelity simulator. MATERIALS AND METHODS: The Mentice VIST simulator was used for three different renal artery stenosis simulations of varying difficulty, which were used to grade performance. Fellows' indices at three intervals throughout 1 year were compared to expert baseline performance. Seventy-four simulated procedures were performed, 63 of which were captured as audiovisual recordings. Three levels of fellow experience were analyzed: 1, 6, and 12 months of dedicated interventional radiology fellowship. The recordings were compiled on a computer workstation and analyzed. Distinct measurable events in the procedures were identified with task analysis, and data regarding efficiency were extracted. Total scores were calculated as the product of procedure time, fluoroscopy time, tools, and contrast agent volume. The lowest scores, which reflected efficient use of tools, radiation, and time, were considered to indicate proficiency. Subjective analysis of participants' procedural errors was not included in this analysis. RESULTS: Fellows' mean scores diminished from 1 month to 12 months (42,960 at 1 month, 18,726 at 6 months, and 9,636 at 12 months). The experts' mean score was 4,660. In addition, the range of variance in score diminished with increasing experience (from a range of 5,940-120,156 at 1 month to 2,436-85,272 at 6 months and 2,160-32,400 at 12 months). Expert scores ranged from 1,450 to 10,800. CONCLUSIONS: Objective efficiency indices for simulated procedures can demonstrate scores directly comparable to the level of clinical experience.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Morphological and biochemical magnetic resonance imaging (MRI) is due to high field MR systems, advanced coil technology, and sophisticated sequence protocols capable of visualizing articular cartilage in vivo with high resolution in clinical applicable scan time. Several conventional two-dimensional (2D) and three-dimensional (3D) approaches show changes in cartilage structure. Furthermore newer isotropic 3D sequences show great promise in improving cartilage imaging and additionally in diagnosing surrounding pathologies within the knee joint. Functional MR approaches are additionally able to provide a specific measure of the composition of cartilage. Cartilage physiology and ultra-structure can be determined, changes in cartilage macromolecules can be detected, and cartilage repair tissue can thus be assessed and potentially differentiated. In cartilage defects and following nonsurgical and surgical cartilage repair, morphological MRI provides the basis for diagnosis and follow-up evaluation, whereas biochemical MRI provides a deeper insight into the composition of cartilage and cartilage repair tissue. A combination of both, together with clinical evaluation, may represent a desirable multimodal approach in the future, also available in routine clinical use.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To prospectively compare cartilage T2 values after microfracture therapy (MFX) and matrix-associated autologous chondrocyte transplantation (MACT) repair procedures. MATERIALS AND METHODS: The study had institutional review board approval by the ethics committee of the Medical University of Vienna; informed consent was obtained. Twenty patients who underwent MFX or MACT (10 in each group) were enrolled. For comparability, patients of each group were matched by mean age (MFX, 40.0 years +/- 15.4 [standard deviation]; MACT, 41.0 years +/- 8.9) and postoperative interval (MFX, 28.6 months +/- 5.2; MACT, 27.4 months +/- 13.1). Magnetic resonance (MR) imaging was performed with a 3-T MR imager, and T2 maps were calculated from a multiecho spin-echo measurement. Global, as well as zonal, quantitative T2 values were calculated within the cartilage repair area and within cartilage sites determined to be morphologically normal articular cartilage. Additionally, with consideration of the zonal organization, global regions of interest were subdivided into deep and superficial areas. Differences between cartilage sites and groups were calculated by using a three-way analysis of variance. RESULTS: Quantitative T2 assessment of normal native hyaline cartilage showed similar results for all patients and a significant trend of increasing T2 values from deep to superficial zones (P < .05). In cartilage repair areas after MFX, global mean T2 was significantly reduced (P < .05), whereas after MACT, mean T2 was not reduced (P > or = .05). For zonal variation, repair tissue after MFX showed no significant trend between different depths (P > or = .05), in contrast to repair tissue after MACT, in which a significant increase from deep to superficial zones (P < .05) could be observed. CONCLUSION: Quantitative T2 mapping seems to reflect differences in repair tissues formed after two surgical cartilage repair procedures. (c) RSNA, 2008.