181 resultados para Radiologists


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Acute knee injury is a common event throughout life, and it is usually the result of a traffic accident, simple fall, or twisting injury. Over 90% of patients with acute knee injury undergo radiography. An overlooked fracture or delayed diagnosis can lead to poor patient outcome. The major aim of this thesis was retrospectively to study imaging of knee injury with a special focus on tibial plateau fractures in patients referred to a level-one trauma center. Multi-detector computed tomography (MDCT) findings of acute knee trauma were studied and compared to radiography, as well as whether non-contrast MDCT can detect cruciate ligaments with reasonable accuracy. The prevalence, type, and location of meniscal injuries in magnetic resonance imaging (MRI) were evaluated, particularly in order to assess the prevalence of unstable meniscal tears in acute knee trauma with tibial plateau fractures. The possibility to analyze with conventional MRI the signal appearance of menisci repaired with bioabsorbable arrows was also studied. The postoperative use of MDCT was studied in surgically treated tibial plateau fractures: to establish the frequency and indications of MDCT and to assess the common findings and their clinical impact in a level-one trauma hospital. This thesis focused on MDCT and MRI of knee injuries, and radiographs were analyzed when applica-ble. Radiography constitutes the basis for imaging acute knee injury, but MDCT can yield information beyond the capabilities of radiography. Especially in severely injured patients , sufficient radiographs are often difficult to obtain, and in those patients, radiography is unreliable to rule out fractures. MDCT detected intact cruciate ligaments with good specificity, accuracy, and negative predictive value, but the assessment of torn ligaments was unreliable. A total of 36% (14/39) patients with tibial plateau fracture had an unstable meniscal tear in MRI. When a meniscal tear is properly detected preoperatively, treatment can be combined with primary fracture fixation, thus avoiding another operation. The number of meniscal contusions was high. Awareness of the imaging features of this meniscal abnormality can help radiologists increase specificity by avoiding false-positive findings in meniscal tears. Postoperative menisci treated with bioabsorbable arrows showed no difference, among different signal intensities in MRI, among menisci between patients with operated or intact ACL. The highest incidence of menisci with an increased signal intensity extending to the meniscal surface was in patients whose surgery was within the previous 18 months. The results may indicate that a rather long time is necessary for menisci to heal completely after arrow repair. Whether the menisci with an increased signal intensity extending to the meniscal surface represent improper healing or re-tear, or whether this is just the earlier healing feature in the natural process remains unclear, and further prospective studies are needed to clarify this. Postoperative use of MDCT in tibial plateau fractures was rather infrequent even in this large trauma center, but when performed, it revealed clinically significant information, thus benefitting patients in regard to treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

According to a large body of evidence, carotid endarterectomy (CEA) can prevent strokes, provided that appropriate inclusion criteria and high-quality perioperative treatment methods are utilised with low complication rates. From the patient s perspective, it is of paramount importance that the operation is as safe and effective as possible. From the community s point of view, it is important that CEA provision prevents as many strokes as possible. In order to define the stroke preventing potential of CEA in different communities, a comparison between eight European countries and Australia was performed including 53 077 carotid interventions. A more detailed evaluation was performed in Finland, the United Kingdom and Egypt. It could be estimated that many potentially preventable strokes occur due to insufficient diagnostics and CEA provision. The number of CEAs should be at least doubled in the Helsinki region. The theoretical power of CEA provision in stroke prevention varied significantly between the countries. Delay from symptom to surgery has been identified as one of the most important factors influencing the effectiveness of CEA. In 2008 only 11% of CEAs in Helsinki university central hospital (HUCH) were performed within the recommended14 days. Registered data of 673 CEAs in HUCH during 2000-2005 was analyzed. There was no systematic error that would have changed the outcome analysis. However it is important that registers are audited regularly and cross matching of different registries is possible. A previously unpublished method of combining medial mandibulotomy, neck incision and carotid artery interposition was carried out as a collaboration of maxillofacial, ear, nose and throat and vascular surgeons. Five patients were operated on with a technique that was feasible and possible to perform with little morbidity, but due to the significant risks involved, this technique should be reserved for carefully selected cases. In stroke prevention, organisational decisions seem far more important than details in interventional procedures when CEA is performed with low complication rates, as was the case in the present study. A TIA clinic approach with close co-operation between the on-call vascular surgeons, neurologists and radiologists should be available at all centres treating these patients. Patients should have a direct and fast admission to the hospital performing CEA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper we examine the use of electronic patient records (EPR) by clinical specialists in their development of multidisciplinary care for diagnosis and treatment of breast cancer. We develop a practice theory lens to investigate EPR use across multidisciplinary team practice. Our findings suggest that there are oppositional tendencies towards diversity in EPR use and unity which emerges across multidisciplinary work, and this influences the outcomes of EPR use. The value of this perspective is illustrated through the analysis of a year-long, longitudinal case study of a multidisciplinary team of surgeons, oncologists, pathologists, radiologists, and nurse specialists adopting a new EPR. Each group adapted their use of the EPR to their diverse specialist practices, but they nonetheless orientated their use of the EPR to each others' practices sufficiently to support unity in multidisciplinary teamwork. Multidisciplinary practice elements were also reconfigured in an episode of explicit negotiations, resulting in significant changes in EPR use within team meetings. Our study contributes to the growing literature that questions the feasibility and necessity of achieving high levels of standardized, uniform health information technology use in healthcare.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Y. Zhu, S. Williams and R. Zwiggelaar, 'Computer technology in detection and staging of prostate carcinoma: a review', Medical Image Analysis 10 (2), 178-199 (2006)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

One problem in most three-dimensional (3D) scalar data visualization techniques is that they often overlook to depict uncertainty that comes with the 3D scalar data and thus fail to faithfully present the 3D scalar data and have risks which may mislead users’ interpretations, conclusions or even decisions. Therefore this thesis focuses on the study of uncertainty visualization in 3D scalar data and we seek to create better uncertainty visualization techniques, as well as to find out the advantages/disadvantages of those state-of-the-art uncertainty visualization techniques. To do this, we address three specific hypotheses: (1) the proposed Texture uncertainty visualization technique enables users to better identify scalar/error data, and provides reduced visual overload and more appropriate brightness than four state-of-the-art uncertainty visualization techniques, as demonstrated using a perceptual effectiveness user study. (2) The proposed Linked Views and Interactive Specification (LVIS) uncertainty visualization technique enables users to better search max/min scalar and error data than four state-of-the-art uncertainty visualization techniques, as demonstrated using a perceptual effectiveness user study. (3) The proposed Probabilistic Query uncertainty visualization technique, in comparison to traditional Direct Volume Rendering (DVR) methods, enables radiologists/physicians to better identify possible alternative renderings relevant to a diagnosis and the classification probabilities associated to the materials appeared on these renderings; this leads to improved decision support for diagnosis, as demonstrated in the domain of medical imaging. For each hypothesis, we test it by following/implementing a unified framework that consists of three main steps: the first main step is uncertainty data modeling, which clearly defines and generates certainty types of uncertainty associated to given 3D scalar data. The second main step is uncertainty visualization, which transforms the 3D scalar data and their associated uncertainty generated from the first main step into two-dimensional (2D) images for insight, interpretation or communication. The third main step is evaluation, which transforms the 2D images generated from the second main step into quantitative scores according to specific user tasks, and statistically analyzes the scores. As a result, the quality of each uncertainty visualization technique is determined.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Mammography is known to be one of the most difficult radiographic exams to interpret. Mammography has important limitations, including the superposition of normal tissue that can obscure a mass, chance alignment of normal tissue to mimic a true lesion and the inability to derive volumetric information. It has been shown that stereomammography can overcome these deficiencies by showing that layers of normal tissue lay at different depths. If standard stereomammography (i.e., a single stereoscopic pair consisting of two projection images) can significantly improve lesion detection, how will multiview stereoscopy (MVS), where many projection images are used, compare to mammography? The aim of this study was to assess the relative performance of MVS compared to mammography for breast mass detection. METHODS: The MVS image sets consisted of the 25 raw projection images acquired over an arc of approximately 45 degrees using a Siemens prototype breast tomosynthesis system. The mammograms were acquired using a commercial Siemens FFDM system. The raw data were taken from both of these systems for 27 cases and realistic simulated mass lesions were added to duplicates of the 27 images at the same local contrast. The images with lesions (27 mammography and 27 MVS) and the images without lesions (27 mammography and 27 MVS) were then postprocessed to provide comparable and representative image appearance across the two modalities. All 108 image sets were shown to five full-time breast imaging radiologists in random order on a state-of-the-art stereoscopic display. The observers were asked to give a confidence rating for each image (0 for lesion definitely not present, 100 for lesion definitely present). The ratings were then compiled and processed using ROC and variance analysis. RESULTS: The mean AUC for the five observers was 0.614 +/- 0.055 for mammography and 0.778 +/- 0.052 for multiview stereoscopy. The difference of 0.164 +/- 0.065 was statistically significant with a p-value of 0.0148. CONCLUSIONS: The differences in the AUCs and the p-value suggest that multiview stereoscopy has a statistically significant advantage over mammography in the detection of simulated breast masses. This highlights the dominance of anatomical noise compared to quantum noise for breast mass detection. It also shows that significant lesion detection can be achieved with MVS without any of the artifacts associated with tomosynthesis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

CONCLUSION Radiation dose reduction, while saving image quality could be easily implemented with this approach. Furthermore, the availability of a dosimetric data archive provides immediate feedbacks, related to the implemented optimization strategies. Background JCI Standards and European Legislation (EURATOM 59/2013) require the implementation of patient radiation protection programs in diagnostic radiology. Aim of this study is to demonstrate the possibility to reduce patients radiation exposure without decreasing image quality, through a multidisciplinary team (MT), which analyzes dosimetric data of diagnostic examinations. Evaluation Data from CT examinations performed with two different scanners (Siemens DefinitionTM and GE LightSpeed UltraTM) between November and December 2013 are considered. CT scanners are configured to automatically send images to DoseWatch© software, which is able to store output parameters (e.g. kVp, mAs, pitch ) and exposure data (e.g. CTDIvol, DLP, SSDE). Data are analyzed and discussed by a MT composed by Medical Physicists and Radiologists, to identify protocols which show critical dosimetric values, then suggest possible improvement actions to be implemented. Furthermore, the large amount of data available allows to monitor diagnostic protocols currently in use and to identify different statistic populations for each of them. Discussion We identified critical values of average CTDIvol for head and facial bones examinations (respectively 61.8 mGy, 151 scans; 61.6 mGy, 72 scans), performed with the GE LightSpeed CTTM. Statistic analysis allowed us to identify the presence of two different populations for head scan, one of which was only 10% of the total number of scans and corresponded to lower exposure values. The MT adopted this protocol as standard. Moreover, the constant output parameters monitoring allowed us to identify unusual values in facial bones exams, due to changes during maintenance service, which the team promptly suggested to correct. This resulted in a substantial dose saving in CTDIvol average values of approximately 15% and 50% for head and facial bones exams, respectively. Diagnostic image quality was deemed suitable for clinical use by radiologists.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims: High local control rates are achieved in stage I lung cancer using stereotactic ablative radiotherapy. Target delineation is commonly based on four-dimensional computed tomography (CT) scans. Target volumes defined by positron emission tomography/computed tomography (PET/CT) are compared with those defined by four-dimensional CT and conventional ('three-dimensional') F-fluorodeoxyglucose (F-FDG) PET/CT. Materials and methods: For 16 stage I non-small cell lung cancer tumours, six approaches for deriving PET target volumes were evaluated: manual contouring, standardised uptake value (SUV) absolute threshold of 2.5, 35% of maximum SUV (35%SUV), 41% of SUV (41%SUV) and two different source to background ratio techniques (SBR-1 and SBR-2). PET-derived target volumes were compared with the internal target volume (ITV) from the modified maximum intensity projection (MIP ITV). Volumetric and positional correlation was assessed using the Dice similarity coefficient (DSC). Results: PET-based target volumes did not correspond to four-dimensional CT-based target volumes. The mean DSC relative to MIP ITV were: PET manual = 0.64, SUV2.5 = 0.64, 35%SUV = 0.63, 41%SUV = 0.57. SBR-1 = 0.52, SBR-2 = 0.49. PET-based target volumes were smaller than corresponding MIP ITVs. Conclusions: Conventional three-dimensional F-FDG PET-derived target volumes for lung stereotactic ablative radiotherapy did not correspond well with those derived from four-dimensional CT, including those in routine clinical use (MIP ITV). Caution is required in using three-dimensional PET for motion encompassing target volume delineation. © 2012 The Royal College of Radiologists.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Intrafraction tumour motion is an issue that is of increased interest in the era of image-guided radiotherapy. It is particularly relevant for non-small cell lung cancer, for which a number of recent developments are in use to aid with motion management in the delivery of radical radiotherapy. The ability to deliver hypofractionated ablative doses, such as in stereotactic radiotherapy, has been aided by improvements in the ability to analyse tumour motion and amend treatment delivery. In addition, accounting for tumour motion can enable dose escalation to occur by reducing the normal tissue being irradiated by virtue of a reduction in target volumes. Motion management for lung tumours incorporates five key components: imaging, breath-hold techniques, abdominal compression, respiratory tracking and respiratory gating. These will be described, together with the relevant benefits and associated complexities. Many studies have described improved dosimetric coverage and reduced normal tissue complication probability rates when using motion management techniques. Despite the widespread uptake of many of these techniques, there is a paucity of literature reporting improved outcome in overall survival and local control for patients whenever motion management techniques are used. This overview will review the extent of lung tumour motion, ways in which motion is detected and summarise the key methods used in motion management.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS: High local control rates are achieved in stage I lung cancer using
stereotactic ablative radiotherapy. Target delineation is commonly based on
four-dimensional computed tomography (CT) scans. Target volumes defined by
positron emission tomography/computed tomography (PET/CT) are compared with those defined by four-dimensional CT and conventional ('three-dimensional')
(18)F-fluorodeoxyglucose ((18)F-FDG) PET/CT.

MATERIALS AND METHODS: For 16 stage I non-small cell lung cancer tumours, six
approaches for deriving PET target volumes were evaluated: manual contouring,
standardised uptake value (SUV) absolute threshold of 2.5, 35% of maximum SUV
(35%SUV(MAX)), 41% of SUV(MAX) (41%SUV(MAX)) and two different source to
background ratio techniques (SBR-1 and SBR-2). PET-derived target volumes were compared with the internal target volume (ITV) from the modified maximum
intensity projection (MIP(MOD) ITV). Volumetric and positional correlation was
assessed using the Dice similarity coefficient (DSC).

RESULTS: PET-based target volumes did not correspond to four-dimensional CT-based target volumes. The mean DSC relative to MIP(MOD) ITV were: PET manual = 0.64, SUV2.5 = 0.64, 35%SUV(MAX) = 0.63, 41%SUV(MAX) = 0.57. SBR-1 = 0.52, SBR-2 =0.49. PET-based target volumes were smaller than corresponding MIP ITVs.

CONCLUSIONS: Conventional three-dimensional (18)F-FDG PET-derived target volumes for lung stereotactic ablative radiotherapy did not correspond well with those derived from four-dimensional CT, including those in routine clinical use
(MIP(MOD) ITV). Caution is required in using three-dimensional PET for motion
encompassing target volume delineation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The present work was planned to report the incidence of calcification and ossification of an isolated cranial dural fold. The form, degree of severity and range of extension of such changes will be described. Involvement of the neighboring brain tissue and blood vessels, whether meningeal or cerebral, will also be determined. The results of this study might highlight the occasional incidence of intracranial calcification and ossification in images of the head and their interpretation, by radiologists and neurologists, to be of dural or vascular origin.

METHODS: Two human formalin-fixed cadavers, one middle-aged female another older male, were investigated at the Anatomy Laboratory, College of Medicine, King Faisal University, Dammam, Kingdom of Saudi Arabia during the period from 2000 to 2003. In each cadaver, the skullcap was removed and the convexity of the cranial dura mater, as well as the individual dural folds, were carefully examined for any calcification or ossification. The meningeal and cerebral blood vessels together with the underlying brain were grossly inspected for such structural changes. Calcified or ossified tissues, when identified, were subjected to histological examination to confirm their construction.

RESULTS: The female cadaver showed a calcified parietal emissary vein piercing the skullcap and projecting into the scalp. The latter looked paler and deficient in hair on its right side. The base of the stump was surrounded by a granular patch of calcification. The upper convex border of the falx cerebri was hardened and it presented granules, plaques and a cauliflower mass, which all proved to be osseous in structure. The meningeal and right cerebral vessels were mottled with calcium granules. The underlying temporal and parietal lobes of the right cerebral hemisphere were degenerated. The male cadaver also revealed a calcified upper border of the falx cerebri and superior sagittal sinus. Osseous granules and plaques, similar to those of the first specimen, were also identified but without gross changes in the underlying brain.

CONCLUSION: Calcification or ossification of an isolated site of the cranial dura mater and the intracranial blood vessels might occur. These changes should be kept in mind while interpreting images of the skull and brain. Clinical assessment and laboratory investigations are required to determine whether these changes are idiopathic, traumatic, or as a manifestation of a generalized disease such as hyperparathyroidism, vitamin D-intoxication, or chronic renal failure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O desenvolvimento das soluções baseadas em telemedicina tem permitido a criação e o desenvolvimento de novas formas de prestar cuidados de saúde, aproximando prestadores de pacientes e diminuindo os tempos de espera associados, melhorando a qualidade do serviço prestado. No entanto, nem sempre a introdução de tecnologia nos processos de saúde corresponde a uma redução nas assimetrias existentes a nível nacional na prestação de cuidados. O principal objectivo deste trabalho consistiu em desenvolver um sistema que permita a criação de um mercado electrónico de teleradiologia tirando partido das soluções tecnologicamente evoluídas já existentes e da boa distribuição de equipamento a nível nacional. Neste mercado é possível maximizar a satisfação de pacientes e entidades requisitantes de exames radiológicos em relação ao serviço prestado, sem prejudicar a qualidade do serviço prestado, ao mesmo tempo que optimiza a utilização do equipamento disponibilizado. Para tal, foi verificado o actual estado da arte em termos de sistemas de telemedicina e de teleradiologia, tendo igualmente sido confirmada a percepção existente das assimetrias a nível nacional em termos de distribuição de recursos humanos no sector da saúde. Depois de verificar o actual fluxo de trabalho em termos de requisição, execução e interpretação de exames imagiológicos, procedeu-se à sua optimização e adaptação para um mercado de teleradiologia, desenhando um conjunto de requisitos associados com as principais etapas de execução dos exames, identificando os principais entraves ao seu funcionamento e propondo mecanismos originais de resolução com base em sistemas de informação. Ao nível de sistemas de informação, é apresentado um protótipo que possibilita a demonstração da implementação de alguns dos mais importantes requisitos anteriormente apresentados e o seu funcionamento, demonstrando o funcionamento prático do sistema de mercado de imagens baseado em teleradiologia. Finalmente é demonstrada a exequibilidade prática desta solução mediante a apresentação de um modelo de negócio onde se apresentam os benefícios decorrentes da implementação deste sistema e os respectivos custos associados com a implementação de uma infra-estrutura desta natureza.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O cancro da mama feminino pela sua magnitude merece uma especial atenção ao nível das políticas de saúde. Emerge, pois uma visão abrangente que, por um lado, deve atentar para o encargo que esta representa para qualquer sistema de saúde, pelos custos que acarreta, como também, para a qualidade de vida das mulheres portadoras da mesma. Desta forma, a Liga Portuguesa Contra o Cancro (LPCC) tem desenvolvido, em colaboração com as Administrações Regionais de Saúde (ARS), o Programa de Rastreio do Cancro da Mama (PRCM), o qual apresenta, no Concelho de Aveiro, taxas de adesão na ordem dos 50%, ainda distantes dos 70%, objetivo recomendado pelas guidelines da Comissão Europeia. A não adesão tem sido considerada como um dos principais problemas do sistema de saúde, tanto pelas repercussões ao nível de ganhos em saúde, como também na qualidade de vida e na satisfação dos pacientes com os cuidados de saúde, constituindo-se como um fenómeno multifatorial e multidimensional. É neste sentido que o presente trabalho se propõe identificar os fatores, de cariz individual e do meio envolvente, determinantes da adesão ao PRCM, numa amostra de mulheres residentes no Concelho de Aveiro, com idades compreendidas entre os 45 e os 69 anos e, a partir dos resultados emergentes, propor estratégias de educação em saúde. Como procedimentos metodológicos e, numa primeira fase, entre outubro 2009 e maio 2010 foi aplicado um survey, o qual foi complementado com notas de campo dos entrevistadores a uma amostra não aleatória de 805 mulheres, em dois contextos distintos: no centro de saúde às aderentes à mamografia e, no domicílio, às não aderentes. Numa segunda fase, realizamos duas sessões de Focus Group (FG), num total de 12 elementos, um grupo heterogéneo com enfermeiros, médicos e utentes, e um outro grupo homogéneo, apenas com profissionais de saúde. O tratamento dos dados do survey foi efetuado através de procedimentos estatísticos, com utilização do SPSS® versão 17 e realizadas análises bivariadas (qui-quadrado) e multivariadas (discriminação de função e árvore de decisão através do algoritmo Chi-squared Automatic Interaction Detector) com o intuito de determinar as diferenças entre os grupos e predizer as variáveis exógenas. No que diz respeito a indicadores sociodemográficos, os resultados mostram que aderem mais, as mulheres com idades <50 anos e ≥ 56 anos, as que vivem em localidades urbanas, as trabalhadoras não qualificadas e as reformadas. As que aderem menos ao PRCM têm idades compreendidas entre os 50-55 anos, vivem nas zonas periurbanas, são licenciadas, apresentam categoria profissional superior ou estão desempregadas. Em relação às restantes variáveis exógenas, aderem ao PRCM, as mulheres que apresentam um Bom Perfil de Conhecimentos (46.6%), enquanto as não aderentes apresentam um Fraco Perfil de Conhecimentos (50.6%), sendo esta relação estatisticamente significativa (X2= 10.260; p=0.006).Cerca de 59% das mulheres aderentes realiza o seu rastreio de forma concordante com as orientações programáticas presentes no PRCM, comparativamente com 41.1% das mulheres que não o faz, verificando-se uma relação de dependência bastante significativa entre as variáveis Perfil de Comportamentos e adesão(X2= 348.193; p=0.000). Apesar de não existir dependência estatisticamente significativa entre as Motivações e a adesão ao PRCM (X2= 0.199; p=0.656), se analisarmos particularmente, os motivos de adesão, algumas inquiridas demonstram preocupação, tanto na deteção precoce da doença, como na hereditariedade. Por outro lado, os motivos de não adesão, também denotam aspetos de nível pessoal como o desleixo com a saúde, o desconhecimento e o esquecimento da marcação. As mulheres que revelam Boa Acessibilidade aos Cuidados de Saúde Primários e um Bom Atendimento dos Prestadores de Cuidados aderem mais ao PRCM, comparativamente com as inquiridas que relatam Fraca Acessibilidade e Atendimento, não aderindo. A partir dos resultados da análise multivariada podemos inferir que as variáveis exógenas estudadas possuem um poder discriminante significativo, sendo que, o Perfil de Comportamentos é a variável que apresenta maior grau de diferenciação entre os grupos das aderentes e não aderentes. Como variáveis explicativas resultantes da árvore de decisão CHAID, permaneceram, o Perfil de Comportamentos (concordantes e não concordantes com as guidelines), os grupos etários (<50 anos, 50-55anos e ≥56anos) e o Atendimento dos prestadores de cuidados de saúde. As mulheres mais novas (<50 anos) com Perfil de comportamentos «concordantes» com as guidelines são as que aderem mais, comparativamente com os outros grupos etários. Por outro lado, as não aderentes necessitam de um «bom» atendimento dos prestadores de cuidados para se tornarem aderentes ao PRCM. Tanto as notas de campo, como a discussão dos FG foram sujeitas a análise de conteúdo segundo as categorias em estudo obtidas na primeira fase e os relatos mostram a importância de fatores de ordem individual e do meio envolvente. No que se refere a aspetos psicossociais, destaca-se a importância das crenças e como fatores ambientais menos facilitadores para a adesão apontam a falta de transportes, a falta de tempo das pessoas e a oferta de recursos, principalmente se existirem radiologistas privados como alternativa ao PRCM. Tal como na primeira fase do estudo, uma das motivações para a adesão é a recomendação dos profissionais de saúde para o PRCM, bem como a marcação de consultas pela enfermeira, que pode ser uma oportunidade de contacto para a sensibilização. Os hábitos de vigilância de saúde, a perceção positiva acerca dos programas de saúde no geral, o acesso à informação pertinente sobre o PRCM e a operacionalização deste no terreno parecem ser fatores determinantes segundo a opinião dos elementos dos FG. O tipo e a regularidade no atendimento por parte dos profissionais de saúde, a relação entre profissional de saúde/paciente, a personalização das intervenções educativas, a divulgação que estes fazem do PRCM junto das suas pacientes, bem como, a organização do modelos de cuidados de saúde das unidades de saúde e a forma como os profissionais se envolvem e tomam a responsabilização por um programa desta natureza são fatores condicionantes da adesão. Se atendermos aos resultados deste estudo, verificamos um envolvimento de fatores que integram múltiplos níveis de intervenção, sendo um desafio para as equipas de saúde que pretendam intervir no âmbito do programa de rastreio do cancro da mama. Com efeito, os resultados também apontam para a combinação de múltiplas estratégias que são transversais a vários programas de promoção da saúde, assumindo, desta forma, uma perspetiva multidimensional e dinâmica que visa, essencialmente, a construção social da saúde e do bem-estar (i.e. responsabilização do cidadão pela sua própria saúde e o seu empowerment).