998 resultados para Radiographic densitometry


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives:This study evaluated the influence of ovariectomy 8 weeks after implant placement on bone integrated to titanium implants.Materials and methods:Thirty-eight female rats were submitted to a titanium implant at the tibiae proximal methaphysis. After a healing period of 8 weeks the animals were randomly divided into three groups: control (CTL-10 animals), sham-operated (SHAM-14 animals) and ovariectomy (OVX-14 animals). The CTL group was then sacrificed in order to confirm integration of the implant. The SHAM group was submitted to fictitious surgery and the OVX group was submitted to bilateral ovariectomy. After 12 weeks post-implant placement, the SHAM and OVX groups were sacrificed. In order to confirm the systemic osteopenia in rats, a dual-energy X-ray absorptiometry (DXA) was performed. For the evaluation of bone density, digital radiographs were taken. The grey level of the bone adjacent to implant was measured using image software and the bone density was calculated at six points on both sides of the implant.Results:Densitometry measurements of the femur confirmed systemic bone mass loss in the OVX group. Individualized bone analyses of different regions surrounding the implant showed a significantly lower radiographic bone density (P < 0.05) in the cancellous region of the OVX group (77.48 +/- 23.39 grey levels) when compared with the CTL and SHAM groups (91.61 +/- 32.10 and 102.57 +/- 32.50 grey levels, respectively).Conclusions:The present study showed a decrease of the radiographic bone density in the cancellous region of bone around titanium implants placed 8 weeks before ovariectomy in rats.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Calcaneal apophysitis in children is a self-limited condition that may interfere with walking and physical performance in sports, thus causing concern to the patient and parents. There is still controversy about the significance of the radiographic changes in children with heel pain, since the report of Sever in 1912. One of the reasons is that normal children may display a considerable variation in the radiographic aspects of the secondary ossification center of the calcaneus at different ages. Methods: In this investigation, the developmental aspects of primary and secondary ossification centers of the calcaneus were studied in radiographs obtained from healthy boys and from boys with calcaneal apophysitis. The normal population comprised 392 children and adolescents ranging in age from 6 to 15 years. There were 69 individuals with calcaneal apophysitis ranging in age from 8 to 14 years. Lateral standard radiographs were obtained of both heels, and a copper step wedge was used as a calibration to determine bone density. The following parameters were analyzed on the plain films: time of appearance, fusion and number of fragments of the secondary nucleus, area and bone densitometry of the primary and secondary ossification centers of the calcaneus. Results: In the normal population, the ossification of the secondary nucleus began at 7 years of age, and at 15 years of age, the nucleus was fused in all individuals. In the apophysitis group, the secondary ossification center was present and not fused in all individuals. Both secondary nuclei increased in size with age with no difference between the two groups. Regarding bone density, both the primary and secondary nuclei were less dense in the apophysitis group than their counterparts in the normal population. The most significant difference between the two populations referred to the degree of fragmentation, which was greater in the apophysitis group. Conclusion: Our data showed that the sclerotic aspect of the secondary nucleus of the calcaneus is a normal feature and, therefore, should not be used to establish the diagnosis of Sever's disease. The most consistent difference between the normal and apophysitis group was related to the more fragmented aspect of the secondary nucleus in the latter individuals, which may suggest a mechanical etiology for that condition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this experiment was to determine the normal values of Bone Radiographic Density (BRD) by using the optical densitometry in radiographic images and the Bone Breaking Strength (BBS) of broiler femurs at different ages (8, 22 and 42 d of age). A total of 60 Cobb male broilers were distributed in three age groups of 20 birds. The BRD and the BBS (maxim force and rigidity) values increased (p<0.01) over the course of ages, presenting greater values at 42 d of age when comparing to 8 and 22 d of age, evidencing a biomechanical adaptation of femur to growth. This experiment offers results that can be used in other experiments of broilers fed with different nutritional levels and they can also be related to pathological values, allowing the diagnosis of diseases that affect the integrity of the poultry leg. © Asian Network for Scientific Information, 2011.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dual energy X-ray absorptiometry (DXA) is widely accepted as the reference method for diagnosis and monitoring of osteoporosis and for assessment of fracture risk, especially at hip. However, axial-DXA is not suitable for mass screening, because it is usually confined to specialized centers. We propose a two-step diagnostic approach to postmenopausal osteoporosis: the first step, using an inexpensive, widely available screening technique, aims at risk stratification in postmenopausal women; the second step, DXA of spine and hip is applied only to potentially osteoporotic women preselected on the basis of the screening measurement. In a group of 110 healthy postmenopausal woman, the capability of various peripheral bone measurement techniques to predict osteoporosis at spine and/or hip (T-score < -2.5SD using DXA) was tested using receiver operating characteristic (ROC) curves: radiographic absorptiometry of phalanges (RA), ultrasonometry at calcaneus (QUS. CALC), tibia (SOS.TIB), and phalanges (SOS.PHAL). Thirty-three women had osteoporosis at spine and/or hip with DXA. Areas under the ROC curves were 0.84 for RA, 0.83 for QUS.CALC, 0.77 for SOS.PHAL (p < 0.04 vs RA) and 0.74 for SOS.TIB (p < 0.02 vs RA and p = 0.05 vs QUS.CALC). For levels of sensitivity of 90%, the respective specificities were 67% (RA), 64% (QUS.CALC), 48% (SOS.PHAL), and 39% (SOS.TIB). In a cost-effective two-step, the price of the first step should not exceed 54% (RA), 51% (QUS.CALC), 42% (SOS.PHAL), and 25% (SOS.TIB). In conclusion, RA, QUS.CALC, SOS.PHAL, and SOS.TIB may be useful to preselect postmenopausal women in whom axial DXA is indicated to confirm/exclude osteoporosis at spine or hip.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A prospective, consecutive series of 106 patients receiving endoscopic anterior scoliosis correction. The aim was to analyse changes in radiographic parameters and rib hump in the two years following surgery. Endoscopic anterior scoliosis correction is a level sparing approach, therefore it is important to assess the amount of decompensation which occurs after surgery. All patients received a single anterior rod and vertebral body screws using a standard compression technique. Cleared disc spaces were packed with either mulched femoral head allograft or rib head/iliac crest autograft. Radiographic parameters (major, instrumented, minor Cobb, T5-T12 kyphosis) and rib hump were measured at 2,6,12 and 24 months after surgery. Paired t-tests and Wilcoxon signed ranks tests were used to assess the statistical significant of changes between adjacent time intervals.----- Results: Mean loss of major curve correction from 2 to 24 months after surgery was 4 degrees. Mean loss of rib hump correction was 1.4 degrees. Mean sagittal kyphosis increased from 27 degrees at 2 months to 30.6 degrees at 24 months. Rod fractures and screw-related complications resulted in several degrees less correction than patients without complications, but overall there was no clinically significant decompensation following complications. The study concluded that there are small changes in deformity measures after endoscopic anterior scoliosis surgery, which are statistically significant but not clinically significant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The measurement of Cobb angles from radiographs is routine practice in spinal clinics. The technique relies on the use and availability of specialist equipment such as a goniometer, cobbometer or protractor. The aim of this study was to validate the use of i-Phone (Apple Inc) combined with Tilt Meter Pro software as compared to a protractor in the measurement of Cobb angles. Between November 2008 and December 2008 20 patients were selected at random from the Paediatric Spine Research Groups Database. A power calculation was performed which indicated if n=240 measurements the study had a 96% chance of detecting a 5 degree difference between groups. All patients had idiopathic scoliosis with a range of curve types and severities. The study found the i-Phone combined with Tilt Meter Pro software offers a faster alternative to the traditional method of Cobb angle measurement. The use of i-Phone offers a more convenient way of measuring Cobb angles in the outpatient setting. The intra-observer repeatability of the iPhone is equivalent to the protractor in the measurement of Cobb angles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The measurement of Cobb angles on radiographs of patients with spinal deformities is routine practice in spinal clinics. The technique relies on the use and availability of specialist equipment such as a goniometer, cobbometer or protractor. The aim of this study was to validate the use of i-Phone (Apple Inc) combined with Tilt Meter Pro software as compared to a protractor in the measurement of Cobb angles. The i-Phone combined with Tilt Meter Pro software offers a faster alternative to the traditional method of Cobb angle measurement. The use of i-Phone offers a more convenient way of measuring Cobb angles in the outpatient setting. The intra-observer repeatability of the iPhone is equivalent to the protractor in the measurement of Cobb angles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Summary Generalized Procrustes analysis and thin plate splines were employed to create an average 3D shape template of the proximal femur that was warped to the size and shape of a single 2D radiographic image of a subject. Mean absolute depth errors are comparable with previous approaches utilising multiple 2D input projections. Introduction Several approaches have been adopted to derive volumetric density (g cm-3) from a conventional 2D representation of areal bone mineral density (BMD, g cm-2). Such approaches have generally aimed at deriving an average depth across the areal projection rather than creating a formal 3D shape of the bone. Methods Generalized Procrustes analysis and thin plate splines were employed to create an average 3D shape template of the proximal femur that was subsequently warped to suit the size and shape of a single 2D radiographic image of a subject. CT scans of excised human femora, 18 and 24 scanned at pixel resolutions of 1.08 mm and 0.674 mm, respectively, were equally split into training (created 3D shape template) and test cohorts. Results The mean absolute depth errors of 3.4 mm and 1.73 mm, respectively, for the two CT pixel sizes are comparable with previous approaches based upon multiple 2D input projections. Conclusions This technique has the potential to derive volumetric density from BMD and to facilitate 3D finite element analysis for prediction of the mechanical integrity of the proximal femur. It may further be applied to other anatomical bone sites such as the distal radius and lumbar spine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To assess the repeatability and validity of lens densitometry derived from the Pentacam Scheimpflug imaging system. Setting Eye Clinic, Queensland University of Technology, Brisbane, Australia. Methods This prospective cross-sectional study evaluated 1 eye of subjects with or without cataract. Scheimpflug measurements and slitlamp and retroillumination photographs were taken through a dilated pupil. Lenses were graded with the Lens Opacities Classification System III. Intraobserver and interobserver reliability of 3 observers performing 3 repeated Scheimpflug lens densitometry measurements each was assessed. Three lens densitometry metrics were evaluated: linear, for which a line was drawn through the visual axis and a mean lens densitometry value given; peak, which is the point at which lens densitometry is greatest on the densitogram; 3-dimensional (3D), in which a fixed, circular 3.0 mm area of the lens is selected and a mean lens densitometry value given. Bland and Altman analysis of repeatability for multiple measures was applied; results were reported as the repeatability coefficient and relative repeatability (RR). Results Twenty eyes were evaluated. Repeatability was high. Overall, interobserver repeatability was marginally lower than intraobserver repeatability. The peak was the least reliable metric (RR 37.31%) and 3D, the most reliable (RR 5.88%). Intraobserver and interobserver lens densitometry values in the cataract group were slightly less repeatable than in the noncataract group. Conclusion The intraobserver and interobserver repeatability of Scheimpflug lens densitometry was high in eyes with cataract and eyes without cataract, which supports the use of automated lens density scoring using the Scheimpflug system evaluated in the study

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The primary clinical role of the non-invasive physical measurement of a bone, generally referred to as ‘bone densitometry,’ is to identify those subjects at risk of an osteoporotic fracture and their subsequent response to pharmaceutical intervention. The true ‘gold standard’ measurement of the mechanical integrity of a bone, and hence its fracture load, is a destructive test, generally performed by compressing either a regular shaped sample or whole bone.