236 resultados para Radiofrequency Neurotomy
Resumo:
OBJECTIVETo determine the current status of the literature regarding the clinical efficacy and complication rates of cryoablation vs radiofrequency ablation in the treatment of small renal tumours.METHODSA review of the literature was conducted. There was no language restriction. Studies were obtained from the following sources: MEDLINE, EMBASE and LILACS.Inclusion criteria were (i) case series design with more than one case reported, (ii) use of cryoablation or radiofrequency ablation, (iii) patients with renal cell carcinoma and, (iv) outcome reported as clinical efficacy.When available, we also quantified the complication rates from each included study.Proportional meta-analysis was performed on both outcomes with a random-effects model. The 95% confidential intervals were also calculated.RESULTSThirty-one case series (20 cryoablation, 11 radiofrequency ablation) met all inclusion criteria.The pooled proportion of clinical efficacy was 89% in cryoablation therapy from a total of 457 cases. There was a statistically significant heterogeneity between these studies showing the inconsistency of clinical and methodological aspects.The pooled proportion of clinical efficacy was 90% in radiofrequency ablation therapy from a total of 426 cases. There was no statistically significant heterogeneity between these studies.There was no statistically significant difference regarding complications rate between cryoablation and radiofrequency ablation.CONCLUSIONSThis review shows that both ablation therapies have similar efficacy and complication rates.There is urgency for performing clinical trials with long-term data to establish which intervention is most suitable for the treatment of small renal masses.
Resumo:
• Aim: Radiofrequency is one of the methods used to treat wrinkles and skin lesions, but its application may result in an abrasive wound. The purpose of this study was to evaluate the effect of collagenase ointment on the epithelial healing of an abrasive wound induced by a radiofrequency system. • Methods: An abrasive wound was produced using radiofrequency at the dorsal midline of 30 guinea pigs, which were randomly divided into 2 groups: one group were treated with saline solution and the other group treated with collagenase ointment; both used twice daily. The animals were sacrificed at 1, 7, 15, 30 and 60 postoperative days. Macroscopic, histological and morphometric evaluations were performed and the results were submitted to statistical analysis. • Results: The animals treated with collagenase ointment presented accelerated healing process and less inflammatory cell infiltration than the saline solution treated animals from one to fifteen postoperative days. Morphometric evaluation showed a thicker epidermis and a thinner dermis layer in the saline solution group at one and seven postoperative days, but significant differences between both groups were not observed at thirty and sixty postoperative days. • Conclusion: According to our results the use of collagenase ointment may accelerate the healing process of a radiofrequency induced abrasive wound.
Resumo:
Sacroiliac joint (SIJ) pain is responsible for up to 40% of all cases of lumbar back pain. Objective Report the long-term efficacy of radiofrequency denervation for sacroiliac joint pain at six, twelve and eighteen months. Method Third-two adults’ patients with sacroiliac join pain diagnosis were included for a prospective study. Primary outcome measure was pain intensity on the Numeric Rating Scale (NRS). Secondary outcome measure was Patient Global Impression of Change Scale (PGIC). Results Short-term pain relief was observed, with the mean NRS pain score decreasing from 7.7 ± 1.8 at baseline to 2.8 ± 1.2 at one month and to 3.1 ± 1.9 at six months post-procedure (p < 0.001). Long-term pain relief was sustained at twelve and eighteen months post-procedure, with NRS pain remaining at 3.4 ± 2.1 and 4.0 ± 2.7, respectively. Conclusion Radiofrequency denervation of the SIJ can significantly reduce pain in selected patients with sacroiliac syndrome.
Resumo:
Object. Over the past few decades, various authors have performed open or stereotactic trigeminal nucleotractotomy for the treatment of neuropathic facial pain resistant to medical treatment. Stereotactic procedures can be performed percutaneously under local anesthesia, allowing intraoperative neurological examination as a method for target refinement. However, blind percutaneous procedures in the region of the atlantooccipital transition carry a considerably high risk of vascular injuries that may bring prohibitive neurological deficit or even death. To avoid such complications, the authors present the first clinical use of microendoscopy to assist percutaneous radiofrequency trigeminal nucleotractotomy. The aim of this article is to demonstrate intradural microendoscopic visualization of the medulla oblongata through an atlantooccipital percutaneous approach. Methods. The authors present a case of severe postherpetic facial neuralgia in a patient who underwent the procedure and had satisfactory results. Stereotactic computational image planning for targeting the spinal trigeminal tract and nucleus in the posterolateral medulla was performed, allowing for an accurate percutaneous approach. immediately before radiofrequency electrode insertion, a tine endoscope was introduced to visualize the structures in the cisterna magna. Results. Microendoscopic visualization offered clear identification of the pial surface of the medulla oblongata and its blood vessels, the arachnoid membrane, cranial nerve rootlets and their entry zone, and larger vessels such as the vertebral arteries and the branches of the posterior inferior cerebellar artery. Conclusions. The initial application of this technique suggests that percutaneous microendoscopy may be useful for particular manipulation of the medulla oblongata, increasing the safety of the procedure and likely improving its effectiveness. (DOI: 10.3171/2011.8.JNS11618)
Resumo:
OBJECTIVE. The objective of our study was to evaluate the effectiveness of MRI in the detection of possible residual lesions after radiofrequency ablation (RFA) in the treatment of breast cancer. SUBJECTS AND METHODS. We prospectively evaluated 14 patients who had undergone ultrasound-guided core biopsies diagnostic of invasive ductal carcinoma (IDC; range of diameters, 1.0-3.0 cm) and then ultrasound-guided percutaneous RFA with sentinel node biopsy as the primary treatment. Breast MRI was performed 1 week before RFA to evaluate tumor extension and again 3 weeks after RFA to verify the presence of possible residual lesions. Conventional surgical resection of the tumors was performed 1 week after RFA. The MRI findings were compared with histopathologic analyses to confirm the presence or absence of residual tumor. RESULTS. There was no residual enhancement in seven lesions on the postablation breast MRI scans. These findings were confirmed by negative histopathologic findings in the surgical specimens. The MRI scans of five patients showed small areas of irregular enhancement that corresponded to residual lesions. In the two remaining patients, we observed enhancement of almost the entire lesion, indicating that RFA had failed. CONCLUSION. Breast MRI is effective in detecting residual lesions after RFA in patients with IDC.
Resumo:
We present a geospatial model to predict the radiofrequency electromagnetic field from fixed site transmitters for use in epidemiological exposure assessment. The proposed model extends an existing model toward the prediction of indoor exposure, that is, at the homes of potential study participants. The model is based on accurate operation parameters of all stationary transmitters of mobile communication base stations, and radio broadcast and television transmitters for an extended urban and suburban region in the Basel area (Switzerland). The model was evaluated by calculating Spearman rank correlations and weighted Cohen's kappa (kappa) statistics between the model predictions and measurements obtained at street level, in the homes of volunteers, and in front of the windows of these homes. The correlation coefficients of the numerical predictions with street level measurements were 0.64, with indoor measurements 0.66, and with window measurements 0.67. The kappa coefficients were 0.48 (95%-confidence interval: 0.35-0.61) for street level measurements, 0.44 (95%-CI: 0.32-0.57) for indoor measurements, and 0.53 (95%-CI: 0.42-0.65) for window measurements. Although the modeling of shielding effects by walls and roofs requires considerable simplifications of a complex environment, we found a comparable accuracy of the model for indoor and outdoor points.
Resumo:
Catheter ablation procedures for atrial fibrillation (AF) often involve circumferential antral isolation of pulmonary veins (PV). Inability to reliably identify conduction gaps on the ablation line necessitates placing additional lesions within the intended lesion set.
Resumo:
Background and aims Radiofrequency denervation (RF) of the lumbar facet joints has been shown to be effective in well-selected patients. However, long-term success varies between studies. We evaluated the influence of selected psychosocial and constitutional factors on the outcome of RF, expressed as the duration of pain relief. Methods This prospective observational study included 44 patients who received RF denervations at the University Hospital of Berne. Success was defined as at least 50% pain reduction 7–21 days, 6 months and 1 year after RF therapy. The Cox-regression analysis was performed to evaluate the influence of the following factors on the duration of success: age, sex, depression, work inability and previous surgery. Results Complete follow-up was available for 41 patients. The success rate 7–21 days after the denervation was 76%. It decreased to 32% at 6 months and to 22% at 1 year. The median success duration was 17 weeks (95% CI 10–26). The Cox-regression analysis showed a significant shorter duration of success for patients with depression (hazard ratio [HR] 2.97, 95% CI 1.32–6.65), previous surgery (HR 2.39, 95% CI 1.10–5.21) and number of treated joints (HR 1.95 for each increase in the number of joints, 95% CI 1.14–3.33). In bivariate analyses, only depression was kept to be significant. Conclusions Depression seems to be related with a short duration of success. Based on these findings, a comprehensive study is warranted to evaluate whether psychosocial factors have to be considered when recruiting patients for radiofrequency denervation.
Resumo:
What's known on the subject? And what does the study add? We have previously shown that percutaneous radiofrequency ablation guided by image-fusion technology allows for precise needle placement with real time ultrasound superimposed with pre-loaded imaging, removing the need for real-time CT or MR guidance. Emerging technology also allows real-time tracking of a treatment needle within an organ in a virtually created 3D format. To our knowledge, this is the first study utilising a sophisticated ultrasound-based navigation system that uses both image-fusion and real-time probe-tracking technologies for in-vivo renal ablative intervention.
Resumo:
AIMS: The experience of using radiofrequency ablation (RFA) for the treatment of arrhythmias in children and adolescents is still limited. This study aimed to review the most recent results of RF ablation in children and adolescents in a highly experienced centre with access to both conventional techniques and non-fluoroscopic electroanatomic mapping (CARTO). METHODS AND RESULTS: A total of 154 consecutive patients younger than 19 years treated with RFA during the period 2000-04 were included. Numbers (%) or median (quartiles) are reported. Age was 15 (12-17) years, 70 (45%) were males. Five patients (3%) had congenital heart disease. RFA was successful in 147/154 patients (95%). Arrhythmia recurrence occurred in 11 patients (7%). Procedure time was 55 (35-90) min and fluoroscopy time was 8.8 (4-19) min. Number of RF applications was 4 (2-10) and number of RF applications >20 s was 2 (1-7). One patient (0.7%) had complicating high-grade atrioventricular block. CARTO was used in 18 RF ablation procedures (11%) performed in 15 patients. CONCLUSION: RF ablation can be undertaken in children and adolescents with a high success rate, few recurrences and complications, very short procedure times, and acceptable fluoroscopy times. Non-fluoroscopic electroanatomic mapping is helpful in selected patients.
Resumo:
This article is a systematic review of whether everyday exposure to radiofrequency electromagnetic field (RF-EMF) causes symptoms, and whether some individuals are able to detect low-level RF-EMF (below the ICNIRP [International Commission on Non-Ionizing Radiation Protection] guidelines). Peer-reviewed articles published before August 2007 were identified by means of a systematic literature search. Meta-analytic techniques were used to pool the results from studies investigating the ability to discriminate active from sham RF-EMF exposure. RF-EMF discrimination was investigated in seven studies including a total of 182 self-declared electromagnetic hypersensitive (EHS) individuals and 332 non-EHS individuals. The pooled correct field detection rate was 4.2% better than expected by chance (95% CI: -2.1 to 10.5). There was no evidence that EHS individuals could detect presence or absence of RF-EMF better than other persons. There was little evidence that short-term exposure to a mobile phone or base station causes symptoms based on the results of eight randomized trials investigating 194 EHS and 346 non-EHS individuals in a laboratory. Some of the trials provided evidence for the occurrence of nocebo effects. In population based studies an association between symptoms and exposure to RF-EMF in the everyday environment was repeatedly observed. This review showed that the large majority of individuals who claims to be able to detect low level RF-EMF are not able to do so under double-blind conditions. If such individuals exist, they represent a small minority and have not been identified yet. The available observational studies do not allow differentiating between biophysical from EMF and nocebo effects.
Resumo:
BACKGROUND: Steam pops are a risk of irrigated radiofrequency catheter ablation (RFA) and may cause cardiac perforation. Data to guide radiofrequency (RF) energy titration to avoid steam pops are limited. OBJECTIVE: This study sought to assess the frequency and consequence of audible pops and to determine the feasibility of using the magnitude of impedance change to predict pops. METHODS: We reviewed consecutive endocardial open-irrigated RFA for ventricular tachycardia (VT) with continuously recorded ablation data in 142 patients with structural heart disease. Steam pops were defined as an audible pop associated with a sudden spike in impedance. Ablation lesions before or after pops served as controls. RESULTS: From a total of 4,107 ablation lesions, 62 (1.5%) steam pops occurred in 42 procedures in 38 patients. Perforation with tamponade occurred with 1 of 62 (2%) pops. Applications with pops had a greater impedance decrease (22 +/- 7 Omega vs. 18 +/- 8 Omega, P = .001) and a higher maximum power (45 +/- 5 W vs. 43 +/- 6 W, P = .011), but did not differ in maximum catheter tip temperature (40 degrees C +/- 4 degrees C vs. 40 degrees C +/- 4 degrees C, P = .180) from applications without pops. Eighty percent of pops occurred after impedance decreased by at least 18 Omega. CONCLUSION: During VT ablation with open irrigation, audible pops are infrequent and do not usually cause perforation. Limiting RF power to achieve an impedance decrease of <18 Omega is a feasible method of reducing the likelihood of a pop when perforation risk is of concern.
Resumo:
The goal of this study was to assess the feasibility, safety and success of a system which uses radiofrequency energy (RFE) rather than a device for percutaneous closure of patent foramen ovale (PFO). METHODS: Sixteen patients (10 men, 6 women, mean age 50 years) were included in the study. All of them had a proven PFO with documented right-to-left shunt (RLS) after Valsalva manoeuvre (VM) during transoesophageal echocardiography (TEE). The patients had an average PFO diameter of 6 +/- 2 mm at TEE and an average of 23 +/- 4 microembolic signals (MES) in power M-mode transcranial Doppler sonography (pm-TCD), measured over the middle cerebral artery. An atrial septal aneurysm (ASA) was present in 7 patients (44%). Balloon measurement, performed in all patients, revealed a stretched PFO diameter of 8 +/- 3 mm. In 2 patients (stretched diameter 11 and 14 mm respectively, both with ASA >10 mm), radiofrequency was not applied (PFO too large) and the PFO was closed with an Amplatzer PFO occluder instead. A 6-month follow-up TEE was performed in all patients. RESULTS: There were no serious adverse events during the procedure or at follow-up (12 months average). TEE 6 months after the first RFE procedure showed complete closure of the PFO in 50% of the patients (7/14). Closure appeared to be influenced by PFO diameter, complete closure being achieved in 89% (7/8) with a balloon-stretched diameter < or =7 mm but in none of the patients >7 mm. Only one of the complete closure patients had an ASA. Of the remainder, 4 (29%) had an ASA. Although the PFO was not completely closed in this group, some reduction in the diameter of the PFO and in MES was documented by TEE and pm-TCD with VM. Five of the 7 residual shunt patients received an Amplatzer PFO occluder. Except for one patient with a minimal residual shunt, all showed complete closure of PFO at 6-month follow-up TEE and pm-TCD with VM. The other two refused a closure device. CONCLUSIONS: The results confirm that radiofrequency closure of the PFO is safe albeit less efficacious and more complex than device closure. The technique in its current state should not be attempted in patients with a balloon-stretched PFO diameter >7 mm and an ASA.
Resumo:
Exposimeters are increasingly applied in bioelectromagnetic research to determine personal radiofrequency electromagnetic field (RF-EMF) exposure. The main advantages of exposimeter measurements are their convenient handling for study participants and the large amount of personal exposure data, which can be obtained for several RF-EMF sources. However, the large proportion of measurements below the detection limit is a challenge for data analysis. With the robust ROS (regression on order statistics) method, summary statistics can be calculated by fitting an assumed distribution to the observed data. We used a preliminary sample of 109 weekly exposimeter measurements from the QUALIFEX study to compare summary statistics computed by robust ROS with a naïve approach, where values below the detection limit were replaced by the value of the detection limit. For the total RF-EMF exposure, differences between the naïve approach and the robust ROS were moderate for the 90th percentile and the arithmetic mean. However, exposure contributions from minor RF-EMF sources were considerably overestimated with the naïve approach. This results in an underestimation of the exposure range in the population, which may bias the evaluation of potential exposure-response associations. We conclude from our analyses that summary statistics of exposimeter data calculated by robust ROS are more reliable and more informative than estimates based on a naïve approach. Nevertheless, estimates of source-specific medians or even lower percentiles depend on the assumed data distribution and should be considered with caution.