995 resultados para Radiation fields
Resumo:
OBJECTIVES: Radiotherapy is planned to achieve the optimal physical dose distribution to the target tumour volume whilst minimising dose to the surrounding normal tissue. Recent in vitro experimental evidence has demonstrated an important role for intercellular communication in radiobiological responses following non-uniform exposures. This study aimed to model the impact of these effects in the context of techniques involving highly modulated radiation fields or spatially fractionated treatments such as GRID therapy.
METHODS: Using the small animal radiotherapy research platform (SARRP) as a key enabling technology to deliver precision imaged-guided radiotherapy, it is possible to achieve spatially modulated dose distributions that model typical clinical scenarios. In this work, we planned uniform and spatially fractionated dose distributions using multiple isocentres with beam sizes of 0.5 - 5 mm to obtain 50% volume coverage in a subcutaneous murine tumour model, and applied a model of cellular response that incorporates intercellular communication to assess the potential impact of signalling effects with different ranges.
RESULTS: Models of GRID treatment plans which incorporate intercellular signalling showed increased cell killing within the low dose region. This results in an increase in the Equivalent Uniform Dose (EUD) for GRID exposures compared to standard models, with some GRID exposures being predicted to be more effective than uniform delivery of the same physical dose.
CONCLUSIONS: This study demonstrates the potential impact of radiation induced signalling on tumour cell response for spatially fractionated therapies and identifies key experiments to validate this model and quantify these effects in vivo.
ADVANCES IN KNOWLEDGE: This study highlights the unique opportunities now possible using advanced preclinical techniques to develop a foundation for biophysical optimisation in radiotherapy treatment planning.
Resumo:
Techniques for the accurate measurement of ionising radiation have been evolving since Roentgen first discovered x-rays in 1895; until now experimental measurements of radiation fields in the three spatial dimensions plus time have not been successfully demonstrated. In this work, we embed an organic plastic scintillator in a polymer gel dosimeter to obtain the first quasi-4D experimental measurement of a radiation field.
Resumo:
The effects of electron temperature on the radiation fields and the resistance of a short dipole antenna embedded in a uniaxial plasma have been studied. It is found that for ω < ω_p the antenna excites two waves, a slow wave and a fast wave. These waves propagate only within a cone whose axis is parallel to the biasing magnetostatic field B_o and whose semicone angle is slightly less than sin ^(-1) (ω/ω_p). In the case of ω > ω_p the antenna excites two separate modes of radiation. One of the modes is the electromagnetic mode, while the other mode is of hot plasma origin. A characteristic interference structure is noted in the angular distribution of the field. The far fields are evaluated by asymptotic methods, while the near fields are calculated numerically. The effects of antenna length ℓ, electron thermal speed, collisional and Landau damping on the near field patterns have been studied.
The input and the radiation resistances are calculated and are shown to remain finite for nonzero electron thermal velocities. The effect of Landau damping and the antenna length on the input and radiation resistances has been considered.
The radiation condition for solving Maxwell's equations is discussed and the phase and group velocities for propagation given. It is found that for ω < ω_p in the radial direction (cylindrical coordinates) the power flow is in the opposite direction to that of the phase propagation. For ω > ω_p the hot plasma mode has similar characteristics.
Resumo:
Les collisions proton-proton produites par le LHC imposent un environnement radiatif hostile au détecteur ATLAS. Afin de quantifier les effets de cet environnement sur la performance du détecteur et la sécurité du personnel, plusieurs simulations Monte Carlo ont été réalisées. Toutefois, la mesure directe est indispensable pour suivre les taux de radiation dans ATLAS et aussi pour vérifier les prédictions des simulations. À cette fin, seize détecteurs ATLAS-MPX ont été installés à différents endroits dans les zones expérimentale et technique d'ATLAS. Ils sont composés d'un détecteur au silicium à pixels appelé MPX dont la surface active est partiellement recouverte de convertisseurs de neutrons thermiques, lents et rapides. Les détecteurs ATLAS-MPX mesurent en temps réel les champs de radiation en enregistrant les traces des particules détectées sous forme d'images matricielles. L'analyse des images acquises permet d'identifier les types des particules détectées à partir des formes de leurs traces. Dans ce but, un logiciel de reconnaissance de formes appelé MAFalda a été conçu. Étant donné que les traces des particules fortement ionisantes sont influencées par le partage de charge entre pixels adjacents, un modèle semi-empirique décrivant cet effet a été développé. Grâce à ce modèle, l'énergie des particules fortement ionisantes peut être estimée à partir de la taille de leurs traces. Les convertisseurs de neutrons qui couvrent chaque détecteur ATLAS-MPX forment six régions différentes. L'efficacité de chaque région à détecter les neutrons thermiques, lents et rapides a été déterminée par des mesures d'étalonnage avec des sources connues. L'étude de la réponse des détecteurs ATLAS-MPX à la radiation produite par les collisions frontales de protons à 7TeV dans le centre de masse a montré que le nombre de traces enregistrées est proportionnel à la luminosité du LHC. Ce résultat permet d'utiliser les détecteurs ATLAS-MPX comme moniteurs de luminosité. La méthode proposée pour mesurer et étalonner la luminosité absolue avec ces détecteurs est celle de van der Meer qui est basée sur les paramètres des faisceaux du LHC. Vu la corrélation entre la réponse des détecteurs ATLAS-MPX et la luminosité, les taux de radiation mesurés sont exprimés en termes de fluences de différents types de particules par unité de luminosité intégrée. Un écart significatif a été obtenu en comparant ces fluences avec celles prédites par GCALOR qui est l'une des simulations Monte Carlo du détecteur ATLAS. Par ailleurs, les mesures effectuées après l'arrêt des collisions proton-proton ont montré que les détecteurs ATLAS-MPX permettent d'observer la désintégration des isotopes radioactifs générés au cours des collisions. L'activation résiduelle des matériaux d'ATLAS peut être mesurée avec ces détecteurs grâce à un étalonnage en équivalent de dose ambiant.
Resumo:
We introduce a technique for assessing the diurnal development of convective storm systems based on outgoing longwave radiation fields. Using the size distribution of the storms measured from a series of images, we generate an array in the lengthscale-time domain based on the standard score statistic. It demonstrates succinctly the size evolution of storms as well as the dissipation kinematics. It also provides evidence related to the temperature evolution of the cloud tops. We apply this approach to a test case comparing observations made by the Geostationary Earth Radiation Budget instrument to output from the Met Office Unified Model run at two resolutions. The 12km resolution model produces peak convective activity on all lengthscales significantly earlier in the day than shown by the observations and no evidence for storms growing in size. The 4km resolution model shows realistic timing and growth evolution although the dissipation mechanism still differs from the observed data.
Resumo:
To obtain accurate Monte Carlo simulations of small radiation fields, it is important model the initial source parameters (electron energy and spot size) accurately. However recent studies have shown that small field dosimetry correction factors are insensitive to these parameters. The aim of this work is to extend this concept to test if these parameters affect dose perturbations in general, which is important for detector design and calculating perturbation correction factors. The EGSnrc C++ user code cavity was used for all simulations. Varying amounts of air between 0 and 2 mm were deliberately introduced upstream to a diode and the dose perturbation caused by the air was quantified. These simulations were then repeated using a range of initial electron energies (5.5 to 7.0 MeV) and electron spot sizes (0.7 to 2.2 FWHM). The resultant dose perturbations were large. For example 2 mm of air caused a dose reduction of up to 31% when simulated with a 6 mm field size. However these values did not vary by more than 2 % when simulated across the full range of source parameters tested. If a detector is modified by the introduction of air, one can be confident that the response of the detector will be the same across all similar linear accelerators and the Monte Carlo modelling of each machine is not required.
Resumo:
Introduction Given the known challenges of obtaining accurate measurements of small radiation fields, and the increasing use of small field segments in IMRT beams, this study examined the possible effects of referencing inaccurate field output factors in the planning of IMRT treatments. Methods This study used the Brainlab iPlan treatment planning system to devise IMRT treatment plans for delivery using the Brainlab m3 microMLC (Brainlab, Feldkirchen, Germany). Four pairs of sample IMRT treatments were planned using volumes, beams and prescriptions that were based on a set of test plans described in AAPM TG 119’s recommendations for the commissioning of IMRT treatment planning systems [1]: • C1, a set of three 4 cm volumes with different prescription doses, was modified to reduce the size of the PTV to 2 cm across and to include an OAR dose constraint for one of the other volumes. • C2, a prostate treatment, was planned as described by the TG 119 report [1]. • C3, a head-and-neck treatment with a PTV larger than 10 cm across, was excluded from the study. • C4, an 8 cm long C-shaped PTV surrounding a cylindrical OAR, was planned as described in the TG 119 report [1] and then replanned with the length of the PTV reduced to 4 cm. Both plans in each pair used the same beam angles, collimator angles, dose reference points, prescriptions and constraints. However, one of each pair of plans had its beam modulation optimisation and dose calculation completed with reference to existing iPlan beam data and the other had its beam modulation optimisation and dose calculation completed with reference to revised beam data. The beam data revisions consisted of increasing the field output factor for a 0.6 9 0.6 cm2 field by 17 % and increasing the field output factor for a 1.2 9 1.2 cm2 field by 3 %. Results The use of different beam data resulted in different optimisation results with different microMLC apertures and segment weightings between the two plans for each treatment, which led to large differences (up to 30 % with an average of 5 %) between reference point doses in each pair of plans. These point dose differences are more indicative of the modulation of the plans than of any clinically relevant changes to the overall PTV or OAR doses. By contrast, the maximum, minimum and mean doses to the PTVs and OARs were smaller (less than 1 %, for all beams in three out of four pairs of treatment plans) but are more clinically important. Of the four test cases, only the shortened (4 cm) version of TG 119’s C4 plan showed substantial differences between the overall doses calculated in the volumes of interest using the different sets of beam data and thereby suggested that treatment doses could be affected by changes to small field output factors. An analysis of the complexity of this pair of plans, using Crowe et al.’s TADA code [2], indicated that iPlan’s optimiser had produced IMRT segments comprised of larger numbers of small microMLC leaf separations than in the other three test cases. Conclusion: The use of altered small field output factors can result in substantially altered doses when large numbers of small leaf apertures are used to modulate the beams, even when treating relatively large volumes.
Resumo:
Cancers of the brain and central nervous system account for 1.6% of new cancers and 1.8% of cancer deaths globally. The highest rates of all developed nations are observed in Australia and New Zealand. There are known complexities associated with dose measurement of very small radiation fields. Here, 3D dosimetric verification of treatments for small intracranial tumours using gel dosimetry was investigated.
Resumo:
为适应在n、γ昆合脉冲辐射场中对低强度快脉冲y辐射测量的需要,近年国内新研制出实用型YAlO3:Ce(YAP:Ce)快响应无机闪烁晶体。我们使用脉冲线性电流大于1.5A的光电倍增管,分别配置这种晶体以及CeF3、NaI等晶体构成闪烁探测器,在放射性标准源场中,对晶体的相对探测能力进行测量。测量结果表明:国产新型YAP:Ce无机晶体对这1.25MeV射线的探测能力比同体积的CeF3平均高一个量级,是同体积NaI的40%左右;当晶体厚度小于2mm时,YAP:Ce与CeF2、NaI的输出比值分别大于16和44%,说明厚度越薄晶体的相对探测能力越强。
Resumo:
The relative biological effectiveness (RBE) of passive scattered (PS) and pencil beam scanned (PBS) proton beam delivery techniques for uniform beam configurations was determined by clonogenic survival. The radiobiological impact of modulated beam configurations on cell survival occurring in- or out-of-field for both delivery techniques was determined with intercellular communication intact or physically inhibited. Cell survival responses were compared to those observed using a 6 MV photon beam produced with a linear accelerator. DU-145 cells showed no significant difference in survival response to proton beams delivered by PS and PBS or 6 MV photons taking into account a RBE of 1.1 for protons at the centre of the spread out Bragg peak. Significant out-of-field effects similar to those observed for 6 MV photons were observed for both PS and PBS proton deliveries with cell survival decreasing to 50-60% survival for scattered doses of 0.05 and 0.03 Gy for passive scattered and pencil beam scanned beams respectively. The observed out-of-field responses were shown to be dependent on intercellular communication between the in-and out-of-field cell populations. These data demonstrate, for the first time, a similar RBE between passive and actively scanned proton beams and confirm that out-of-field effects may be important determinants of cell survival following exposure to modulated photon and proton fields
Resumo:
RESUMO - Na radiologia de intervenção, e concretamente em ortopedia, os raios X são intensamente utilizados permitindo a visualização de diversas técnicas de intervenção cirúrgica. Do ponto de vista médico as vantagens dessa prática são enormes, contudo, os profissionais de saúde envolvidos são susceptíveis de estarem expostos a valores de dose de radiação que significam a sua classificação como trabalhadores expostos. O presente estudo realizou-se num hospital e teve como objectivo obter uma estimativa das doses envolvidas em ortopedia de intervenção, utilizando várias metodologias experimentais para caracterização do campo de radiação primário e secundário. Observaram-se distintos níveis de dose de acordo com a zona anatómica exposta à radiação X: (i) gónadas — 0,02 a 3 mGy/h; (ii) cristalino — 0,06 a 1 mGy/h e (iii) mãos — 0,6 mGy/h. Tais resultados evidenciam uma clara necessidade de utilização de equipamentos de protecção e de vigilância dosimétrica pelos profissionais de saúde envolvidos no acto cirúrgico.--------------------------ABSTRACT - In intervention radiology, and more specifically in orthopaedics, X-rays are intensely used allowing the visualization of many acts of clinical intervention. From a clinical perspective, the advantages of that practice are significant; however, involved health care professionals are susceptible of being exposed to radiation dose values that mean their classification as exposed workers. The present study, performed in a hospital, aimed to obtain an estimation of the doses involved in intervention orthopaedics through several experimental methodologies in order to characterise the primary and the secondary radiation fields. Different levels of dose were observed according to the anatomic area exposed to X radiation: (i) gonads — 0.02 a 3 mGy/h; (ii) crystalline lens — 0.06 a 1 mGy/h e (iii) hands – 0.6 mGy/h. Such results denote a clear need of protection equipment use and of dosimetric surveillance by the health
Resumo:
Les seize détecteurs MPX constituant le réseau ATLAS-MPX ont été placés à différentes positions dans le détecteur ATLAS et sa averne au CERN dans le but de mesurer en emps réel les champs de radiation produits ar des particules primaires (protons des faisceaux) et des particules secondaires (kaons, pions, g, protons) issues des collisions proton-proton. Des films de polyéthylène (PE) et de fluorure de lithium (6LiF) recouvrent les détecteurs afin d’augmenter leur sensibilité aux neutrons produits par les particules primaires et secondaires interagissant avec les matériaux présents dans l’environnement d’ATLAS. La reconnaissance des traces laissées par les particules dans un détecteur ATLAS-MPX se fait à partir des algorithmes du logiciel MAFalda (“Medipix Analysis Framework”) basé sur les librairies et le logiciel d’analyse de données ROOT. Une étude sur le taux d’identifications erronées et le chevauchement d’amas a été faite en reconstruisant les activités des sources 106Ru et 137Cs. L’efficacité de détection des neutrons rapides a été mesurée à l’aide des sources 252Cf et 241AmBe (neutrons d’énergie moyenne de 2.13 et 4.08 MeV respectivement). La moyenne des efficacités de détection mesurées pour les neutrons produits par les sources 252C f et 241AmBe a été calculée pour les convertisseurs 6LiF et PE et donnent (0.8580 ± 0.1490)% et (0.0254 ± 0.0031)% pour LiF et (0.0510 ± 0.0061)% et (0.0591 ± 0.0063)% pour PE à bas et à haut seuil d’énergie respectivement. Une simulation du calcul de l’efficacité de détection des neutrons dans le détecteur MPX a été réalisée avec le logiciel GEANT4. Des données MPX correspondant aux collisions proton-proton à 2.4 TeV et à 7 TeV dans le centre de masse ont été analysées. Les flux détectés d’électrons et de photons sont particulièrement élevés dans les détecteurs MPX01 et MPX14 car ils sont plus près du point de collision. Des flux de neutrons ont été estimés en utilisant les efficacités de détection mesurées. Une corrélation avec la luminosité du LHC a été établie et on prédit que pour les collisions à 14 TeV dans le centre de masse et avec une luminosité de 10^34 cm-1*s-1 il y aura environ 5.1x10^8 ± 1.5x10^7 et 1.6x10^9 ± 6.3x10^7 particules détectées par les détecteurs MPX01 et MPX14 respectivement.
Resumo:
Department of Elecctronics, Cochin University of Science and Technology
Resumo:
Nonlinear optics has been a rapidly growing field in recent decades since the invention of lasers. The systematic progress in the laser technology increases our efficiency in the generation and control of coherent optical radiations. Nonlinear optics is based on the study ofeffects and phenomena related to the interaction of intense coherent light radiation with matter. Compared to other light sources laser radiation can provide high directionality, high monochromaticiry, high brightness and high photon degeneracy. At such a very intense incident beam, the matter responds in a nonlinear manner to the incident radiation fields, which endows the media :1 characteristic to change the refractive index or absorption coe fflcient of the media or the wavelength, or the frequency of the incident electromagnetic waves. This thesis encompasses the fabrication of nonlinear optical devices based on semiconductor and metal nanostructures. The presented work focus on the experimental and theoretical discussions on nonlinear optical effects especially nonlinear absorption and refraction exhibitted by metal and semiconductor nanostructures
Resumo:
A novel computer-assisted injection device for the delivery of highly viscous bone cements in vertebroplasty is presented. It addresses the shortcomings of manual injection systems ranging from low-pressure and poor level of control to device failure. The presented instrument is capable of generating a maximum pressure of 5000 kPa in traditional 6-ml syringes and provides an advanced control interface for precise cement delivery from outside radiation fields emitted by intraoperative imaging systems. The integrated real-time monitoring of injection parameters, such as flow-rate, volume, pressure, and viscosity, simplifies consistent documentation of interventions and establishes a basis for the identification of safe injection protocols on the longer term. Control algorithms prevent device failure due to overloading and provide means to immediately stop cement flow to avoid leakage into adjacent tissues.