969 resultados para REFRACTIVE-INDEX MEASUREMENT


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple fiber sensor capable of simultaneous measurement of liquid level and refractive index (RI) is proposed and experimentally demonstrated. The sensing head is an all-fiber modal interferometer manufactured by splicing an uncoated single-mode fiber with two short sections of multimode fiber. The interference pattern experiences blue shift along with an increase of axial strain and surrounding RI. Owing to the participation of multiple cladding modes with different sensitivities, the height and RI of the liquid could be simultaneously measured by monitoring two dips of the transmission spectrum. Experimental results show that the liquid level and RI sensitivities of the two dips are 245.7 pm/mm, -38 nm/RI unit (RIU), and 223.7 pm/mm, -62 nm/RIU, respectively. The approach has distinctive advantages of easy fabrication, low cost, and high sensitivity for liquid level detection with the capability of distinguishing the RI variation simultaneously. © 2013 Copyright Taylor and Francis Group, LLC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We demonstrate tomographic imaging of the refractive index of turbid media using bifocal optical coherence refractometry (BOCR). The technique, which is a variant of optical coherence tomography, is based on the measurement of the optical pathlength difference between two foci simultaneously present in a medium of interest. We describe a new method to axially shift the bifocal optical pathlength that avoids the need to physically relocate the objective lens or the sample during an axial scan, and present an experimental realization based on an adaptive liquid-crystal lens. We present experimental results, including video clips, which demonstrate refractive index tomography of a range of turbid liquid phantoms, as well as of human skin in vivo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report photoinduced photo-darkening in SbPO4-WO3 glass by exposure to 532 nm light with a power density of 143 mW/cm(2). The time of exposure was varied between 0 and 256 min following which visible photo-darkening, peaking at 850 nm was observed. Spectrophotometer measurement of absorption was performed for both treated and untreated regions of the sample. Time exposure to below band-gap light results in a single exponent Gaussian absorption function over an exceptionally wide range of wavelengths (500 nm-1600 nm), with a 1/e width of 647.5 nm. Kramers-Kronig transform of the change in the absorption indicates a negative local change in the refractive index. The dispersed refractive index change at 1550 nm, Delta n, is calculated to be similar to -5 x 10(-8). The peak absorption increases with time of exposure and the photo-darkening remains irreversible at room temperature. Crown Copyright (C) 2010 Published by Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The formation of sulfated zirconia films from a sol-gel derived aqueous suspension is subjected to double-optical monitoring during batch dip coating. Interpretation of interferometric patterns, previously obscured by a variable refractive index, is now made possible by addition of its direct measurement by a polarimetric technique in real time. Significant sensitivity of the resulting physical thickness and refractive index curves (uncertainties of ±7 nm and ±0.005, respectively) to temporal film evolution is shown under different withdrawal speeds. As a first contribution to quantitative understanding of temporal film formation with varying nanostructure during dip coating, detailed analysis is directed to the stage of the process dominated by mass drainage, whose simple modeling with temporal t-1/2 dependence is verified experimentally. © 2006 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A series of surface plasmonic fibre devices were fabricated using multiple coatings deposited on a lapped section of a single mode fibre. Coupling from the guided mode to surface plasmons was promoted following UV laser irradiation of the coated region through a phase mask, which generated a surface relief grating structure. The devices showed high spectral sensitivities and strong coupling for low refractive indices as compared to other grating-type fibre devices. The plasmonic devices were used to detect the variation in the refractive indices of alkane gases with measured wavelength and coupling sensitivity to index of 3400 nm RIU-1 and 8300 dB RIU-1, respectively. As a demonstration of the performance of these gas sensors, a minimum concentration of 2% by volume of butane in ethane was achieved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We propose and experimentally demonstrate a refractive index (RI) sensor based on cascaded microfiber knot resonators (CMKRs) with Vernier effect. Deriving from high proportional evanescent field of microfiber and spectrum magnification function of Vernier effect, the RI sensor shows high sensitivity as well as high detection resolution. By using the method named "Drawing-Knotting-Assembling (DKA)", a compact CMKRs is fabricated for experimental demonstration. With the assistance of Lorentz fitting algorithm on the transmission spectrum, sensitivity of 6523nm/RIU and detection resolution up to 1.533 x 10-7 RIU are obtained in the experiment which show good agreement with the numerical simulation. The proposed all-fiber RI sensor with high sensitivity, compact size and low cost can be widely used for chemical and biological detection, as well as the electronic/magnetic field measurement

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thick smears of human feces can be made adequate for identification of helminth eggs by means of refractive index matching. Although this effect can be obtained by simply spreading a fleck of feces on a microscope slide, a glycerol solution has been routinely used to this end. Aiming at practicability, a new quantitative technique has been developed. To enhance both sharpness and contrast of the images, a sucrose solution (refractive index = 1.49) is used, which reduces the effect of light-scattering particulates. To each slide a template-measured (38.5 mm³) fecal sample is transferred. Thus, egg counts and sensitivity evaluations are easily made.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Diffuse flow velocimetry (DFV) is introduced as a new, noninvasive, optical technique for measuring the velocity of diffuse hydrothermal flow. The technique uses images of a motionless, random medium (e.g.,rocks) obtained through the lens of a moving refraction index anomaly (e.g., a hot upwelling). The method works in two stages. First, the changes in apparent background deformation are calculated using particle image velocimetry (PIV). The deformation vectors are determined by a cross correlation of pixel intensities across consecutive images. Second, the 2-D velocity field is calculated by cross correlating the deformation vectors between consecutive PIV calculations. The accuracy of the method is tested with laboratory and numerical experiments of a laminar, axisymmetric plume in fluids with both constant and temperaturedependent viscosity. Results show that average RMS errors are ∼5%–7% and are most accurate in regions of pervasive apparent background deformation which is commonly encountered in regions of diffuse hydrothermal flow. The method is applied to a 25 s video sequence of diffuse flow from a small fracture captured during the Bathyluck’09 cruise to the Lucky Strike hydrothermal field (September 2009). The velocities of the ∼10°C–15°C effluent reach ∼5.5 cm/s, in strong agreement with previous measurements of diffuse flow. DFV is found to be most accurate for approximately 2‐D flows where background objects have a small spatial scale, such as sand or gravel

Relevância:

100.00% 100.00%

Publicador:

Resumo:

he complex refractive index of SiO2 layers containing Si nanoclusters (Si-nc) has been measured by spectroscopic ellipsometry in the range from 1.5 to 5.0 eV. It has been correlated with the amount of Si excess accurately measured by x-ray photoelectron spectroscopy and the nanocluster size determined by energy-filtered transmission electron microscopy. The Si-nc embedded in SiO2 have been produced by a fourfold Si+ ion implantation, providing uniform Si excess aimed at a reliable ellipsometric modeling. The complex refractive index of the Si-nc phase has been calculated by the application of the Bruggeman effective-medium approximation to the composite media. The characteristic resonances of the refractive index and extinction coefficient of bulk Si vanish out in Si-nc. In agreement with theoretical simulations, a significant reduction of the refractive index of Si-nc is observed, in comparison with bulk and amorphous silicon. The knowledge of the optical properties of these composite layers is crucial for the realization of Si-based waveguides and light-emitting devices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Negative refractive index materials and propagation of electromagnetic waves in them started to draw attention of scientists not so long ago. This review highlights historically important and recent papers on practical and theoretical aspects related to these issues. Namely, basic properties and peculiarities of such materials related to both their design and wave propagation in them, experimental verification of predictions theoretically made for them, possible practical applications and prospects in this area are considered.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

International School of Photonics, Cohin University of Science and Technology

Relevância:

100.00% 100.00%

Publicador:

Resumo:

En les últimes dècades, l'increment dels nivells de radiació solar ultraviolada (UVR) que arriba a la Terra (principalment degut a la disminució d'ozó estratosfèric) juntament amb l'augment detectat en malalties relacionades amb l'exposició a la UVR, ha portat a un gran volum d'investigacions sobre la radiació solar en aquesta banda i els seus efectes en els humans. L'índex ultraviolat (UVI), que ha estat adoptat internacionalment, va ser definit amb el propòsit d'informar al públic general sobre els riscos d'exposar el cos nu a la UVR i per tal d'enviar missatges preventius. L'UVI es va definir inicialment com el valor màxim diari. No obstant, el seu ús actual s'ha ampliat i té sentit referir-se a un valor instantani o a una evolució diària del valor d'UVI mesurat, modelitzat o predit. El valor concret d'UVI està afectat per la geometria Sol-Terra, els núvols, l'ozó, els aerosols, l'altitud i l'albedo superficial. Les mesures d'UVI d'alta qualitat són essencials com a referència i per estudiar tendències a llarg termini; es necessiten també tècniques acurades de modelització per tal d'entendre els factors que afecten la UVR, per predir l'UVI i com a control de qualitat de les mesures. És d'esperar que les mesures més acurades d'UVI s'obtinguin amb espectroradiòmetres. No obstant, com que els costs d'aquests dispositius són elevats, és més habitual trobar dades d'UVI de radiòmetres eritemàtics (de fet, la majoria de les xarxes d'UVI estan equipades amb aquest tipus de sensors). Els millors resultats en modelització s'obtenen amb models de transferència radiativa de dispersió múltiple quan es coneix bé la informació d'entrada. No obstant, habitualment no es coneix informació d'entrada, com per exemple les propietats òptiques dels aerosols, la qual cosa pot portar a importants incerteses en la modelització. Sovint, s'utilitzen models més simples per aplicacions com ara la predicció d'UVI o l'elaboració de mapes d'UVI, ja que aquests són més ràpids i requereixen menys paràmetres d'entrada. Tenint en compte aquest marc de treball, l'objectiu general d'aquest estudi és analitzar l'acord al qual es pot arribar entre la mesura i la modelització d'UVI per condicions de cel sense núvols. D'aquesta manera, en aquest estudi es presenten comparacions model-mesura per diferents tècniques de modelització, diferents opcions d'entrada i per mesures d'UVI tant de radiòmetres eritemàtics com d'espectroradiòmeters. Com a conclusió general, es pot afirmar que la comparació model-mesura és molt útil per detectar limitacions i estimar incerteses tant en les modelitzacions com en les mesures. Pel que fa a la modelització, les principals limitacions que s'han trobat és la falta de coneixement de la informació d'aerosols considerada com a entrada dels models. També, s'han trobat importants diferències entre l'ozó mesurat des de satèl·lit i des de la superfície terrestre, la qual cosa pot portar a diferències importants en l'UVI modelitzat. PTUV, una nova i simple parametrització pel càlcul ràpid d'UVI per condicions de cel serens, ha estat desenvolupada en base a càlculs de transferència radiativa. La parametrització mostra una bona execució tant respecte el model base com en comparació amb diverses mesures d'UVI. PTUV ha demostrat la seva utilitat per aplicacions particulars com ara l'estudi de l'evolució anual de l'UVI per un cert lloc (Girona) i la composició de mapes d'alta resolució de valors d'UVI típics per un territori concret (Catalunya). En relació a les mesures, es constata que és molt important saber la resposta espectral dels radiòmetres eritemàtics per tal d'evitar grans incerteses a la mesura d'UVI. Aquest instruments, si estan ben caracteritzats, mostren una bona comparació amb els espectroradiòmetres d'alta qualitat en la mesura d'UVI. Les qüestions més importants respecte les mesures són la calibració i estabilitat a llarg termini. També, s'ha observat un efecte de temperatura en el PTFE, un material utilitzat en els difusors en alguns instruments, cosa que potencialment podria tenir implicacions importants en el camp experimental. Finalment, i pel que fa a les comparacions model-mesura, el millor acord s'ha trobat quan es consideren mesures d'UVI d'espectroradiòmetres d'alta qualitat i s'usen models de transferència radiativa que consideren les millors dades disponibles pel que fa als paràmetres òptics d'ozó i aerosols i els seus canvis en el temps. D'aquesta manera, l'acord pot ser tan alt dins un 0.1º% en UVI, i típicament entre menys d'un 3%. Aquest acord es veu altament deteriorat si s'ignora la informació d'aerosols i depèn de manera important del valor d'albedo de dispersió simple dels aerosols. Altres dades d'entrada del model, com ara l'albedo superficial i els perfils d'ozó i temperatura introdueixen una incertesa menor en els resultats de modelització.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Much uncertainty in the value of the imaginary part of the refractive index of mineral dust contributes to uncertainty in the radiative effect of mineral dust in the atmosphere. A synthesis of optical, chemical and physical in-situ aircraft measurements from the DODO experiments during February and August 2006 are used to calculate the refractive index mineral dust encountered over West Africa. Radiative transfer modeling and measurements of broadband shortwave irradiance at a range of altitudes are used to test and validate these calculations for a specific dust event on 23 August 2006 over Mauritania. Two techniques are used to determine the refractive index: firstly a method combining measurements of scattering, absorption, size distributions and Mie code simulations, and secondly a method using composition measured on filter samples to apportion the content of internally mixed quartz, calcite and iron oxide-clay aggregates, where the iron oxide is represented by either hematite or goethite and clay by either illite or kaolinite. The imaginary part of the refractive index at 550 nm (ni550) is found to range between 0.0001 i to 0.0046 i, and where filter samples are available, agreement between methods is found depending on mineral combination assumed. The refractive indices are also found to agree well with AERONET data where comparisons are possible. ni550 is found to vary with dust source, which is investigated with the NAME model for each case. The relationship between both size distribution and ni550 on the accumulation mode single scattering albedo at 550 nm (ω0550) are examined and size distribution is found to have no correlation to ω0550, while ni550 shows a strong linear relationship with ω0550. Radiative transfer modeling was performed with different models (Mie-derived refractive indices, but also filter sampling composition assuming both internal and external mixing). Our calculations indicate that Mie-derived values of ni550 and the externally mixed dust where the iron oxide-clay aggregate corresponds to the goethite-kaolinite combination result in the best agreement with irradiance measurements. The radiative effect of the dust is found to be very sensitive to the mineral combination (and hence refractive index) assumed, and to whether the dust is assumed to be internally or externally mixed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The mechanisms of refractive index change in poly(methyl methacrylate) by frequency doubled femtosecond laser pulses are investigated. It is demonstrated that positive refractive index modificaton can be caused by a combination of depolymerization and crosslinking.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Z-scan technique is employed to obtain the nonlinear refractive index (n (2)) of the Ca(4)REO(BO(3))(3) (RECOB, where RE = Gd and La) single crystals using 30 fs laser pulses centered at 780 nm for the two orthogonal orientations determined by the optical axes (X and Z) relative to the direction of propagation of the laser beam (k//Y// crystallographic b-axis). The large values of n (2) indicate that both GdCOB and LaCOB are potential hosts for Yb:RECOB lasers operating in the Kerr-lens mode locking (KLM) regime.